GFL2D30100SN

GFL2D30100SN

  • 厂商:

    ALTECH

  • 封装:

  • 描述:

    MCCB+EGFP 30A120240V AC 100MA D

  • 数据手册
  • 价格&库存
GFL2D30100SN 数据手册
GFL Series - 2 Pole + N, D Trip, 100 mA 10kA UL489 Listed Branch Circuit Breaker with Equipment Ground Fault Protection (RCBO) The GFL Series range is a combined Branch Circuit Breaker and Equipment Ground Fault Protector, featuring dual pole switching (live and neutral disconnect) and designed to provide protection against short circuits, overloads, AC ground faults (residual current faults) as well as pulsating DC ground faults. N 3 1 LINE C.B. W/EQ.GFP E483494 Ordering Information Type/ Cat. No. GFL2D05100SN GFL2D06100SN GFL2D08100SN GFL2D10100SN GFL2D12100SN GFL2D13100SN GFL2D15100SN GFL2D16100SN GFL2D20100SN GFL2D25100SN GFL2D30100SN GFL2D32100SN GFL2D35100SN GFL2D40100SN Rated Voltage 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC 120/240V AC N 4 2 GFL Series RCBO Overload Trip Curves Characteristics B, C, D 7200 3600 2400 1200 600 480 360 240 120 60 40 t(s) UL 489 Branch Circuit Breaker with Ground Fault Relay Rated Current 5.0A 6.0A 8.0A 10A 12A 13A 15A 16A 20A 25A 30A 32A 35A 40A 20 Number of Poles Voltage Rating (maximum) Ground Fault Sensitivity Level Rated Short Circuit Interrupt Capacity Rated Frequency Trip Characteristic Cable Size & Tightening Torque Electrical Life Mechanical Life time 10 2+N 120/240V AC 100 mA 10 kA 50/60Hz D Stranded Wire: 16 - 3 AWG (1.5 mm2 - 25 mm2) @ 17.5 lb-in (2.0 Nm) 16 - 10 AWG (1.5 mm2 - 5.5 mm2) @ 17.5 lb-in (2.0 Nm) Solid Wire: 18 - 16 AWG (1 mm2 - 1.5 mm2) @ 25 lb-in (2.8 Nm) 6000 Switching Operations 10000 Switching Operations 5 Switch Technical Specification 1 0.5 B 0.1 D C 0.05 0.01 2 1 1.05 1.35 3 4 5 6 Rated current multiple Dimensions 7 8 9 10 12 14 16 18 20 xIn (to convert to inches multply by 0.03937) GFL Series RCBO Ground Fault Trip Curve 105mm 45mm t(s) 53mm 0.5 0.4 0.2 0.3 0.15 71mm 60mm 44mm 0.1 0.05 0.04 0.03 0.02 0.015 0.01 0.005 Weight 0.5 1 0.85 1.15 5 I∆ I∆n 353 g 1 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com GFL Series - 2 Pole + N, D Trip, 100 mA Applicable voltage systems and wiring examples. GFL...SN UL 489 Branch Circuit Breaker with Ground Fault Relay L2 N 4 2 LINE 1 3 N LOAD 240 V N 120 V 120 V L1 L1 120 V N 4 2 LINE 3 1 N LOAD JUMPER from terminal 2 to N 240 V N 120 V No N Connection on Load L2 2 35 Royal Road • Flemington, NJ 08822-6000 • t 908-806-9400 • f 908-806-9490 • www.altechcorp.com
GFL2D30100SN 价格&库存

很抱歉,暂时无法提供与“GFL2D30100SN”相匹配的价格&库存,您可以联系我们找货

免费人工找货