0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EP3C40Q240C8N

EP3C40Q240C8N

  • 厂商:

    ALTERA(阿尔特拉)

  • 封装:

    PQFP

  • 描述:

  • 数据手册
  • 价格&库存
EP3C40Q240C8N 数据手册
1. Cyclone III Device Datasheet July 2012 CIII52001-3.5 CIII52001-3.5 This chapter describes the electric characteristics, switching characteristics, and I/O timing for Cyclone® III devices. A glossary is also included for your reference. Electrical Characteristics The following sections provide information about the absolute maximum ratings, recommended operating conditions, DC characteristics, and other specifications for Cyclone III devices. Operating Conditions When Cyclone III devices are implemented in a system, they are rated according to a set of defined parameters. To maintain the highest possible performance and reliability of Cyclone III devices, system designers must consider the operating requirements in this document. Cyclone III devices are offered in commercial, industrial, and automotive grades. Commercial devices are offered in –6 (fastest), –7, and –8 speed grades. Industrial and automotive devices are offered only in –7 speed grade. 1 In this chapter, a prefix associated with the operating temperature range is attached to the speed grades; commercial with “C” prefix, industrial with “I” prefix, and automotive with “A” prefix. Commercial devices are therefore indicated as C6, C7, and C8 per respective speed grades. Industrial and automotive devices are indicated as I7 and A7, respectively. Absolute Maximum Ratings Absolute maximum ratings define the maximum operating conditions for Cyclone III devices. The values are based on experiments conducted with the device and theoretical modeling of breakdown and damage mechanisms. The functional operation of the device is not implied at these conditions. Table 1–1 lists the absolute maximum ratings for Cyclone III devices. © 2012 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. ISO 9001:2008 Registered Cyclone III Device Handbook Volume 2 July 2012 Subscribe 1–2 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1 Conditions beyond those listed in Table 1–1 cause permanent damage to the device. Additionally, device operation at the absolute maximum ratings for extended periods of time has adverse effects on the device. Table 1–1. Cyclone III Devices Absolute Maximum Ratings Symbol Parameter (1) Min Max Unit VCCINT Supply voltage for internal logic –0.5 1.8 V VCCIO Supply voltage for output buffers –0.5 3.9 V VCCA Supply voltage (analog) for phase-locked loop (PLL) regulator –0.5 3.75 V VCCD_PLL Supply voltage (digital) for PLL –0.5 1.8 V VI DC input voltage –0.5 3.95 V IOUT DC output current, per pin –25 40 mA VESDHBM Electrostatic discharge voltage using the human body model — ±2000 V VESDCDM Electrostatic discharge voltage using the charged device model — ±500 V TSTG Storage temperature –65 150 °C TJ Operating junction temperature –40 125 °C Note to Table 1–1: (1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the power supply. Maximum Allowed Overshoot or Undershoot Voltage During transitions, input signals may overshoot to the voltage listed in Table 1–2 and undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and the duration of the overshoot voltage as a percentage over the lifetime of the device. The maximum allowed overshoot duration is specified as percentage of high-time over the lifetime of the device. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1 1–3 A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to 4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime of 10 years, this amounts to 10.74/10ths of a year. Table 1–2. Cyclone III Devices Maximum Allowed Overshoot During Transitions over a 10-Year Time Frame (1) Symbol Vi Parameter Condition AC Input Voltage Overshoot Duration as % of High Time Unit VI = 3.95 V 100 % VI = 4.0 V 95.67 % VI = 4.05 V 55.24 % VI = 4.10 V 31.97 % VI = 4.15 V 18.52 % VI = 4.20 V 10.74 % VI = 4.25 V 6.23 % VI = 4.30 V 3.62 % VI = 4.35 V 2.1 % VI = 4.40 V 1.22 % VI = 4.45 V 0.71 % VI = 4.50 V 0.41 % VI = 4.60 V 0.14 % VI = 4.70 V 0.047 % Note to Table 1–2: (1) Figure 1–1 shows the methodology to determine the overshoot duration. In the example in Figure 1–1, overshoot voltage is shown in red and is present on the input pin of the Cyclone III device at over 4.1 V but below 4.2 V. From Table 1–1, for an overshoot of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over a 10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period assumes the device is always turned on with 100% I/O toggle rate and 50% duty cycle signal. For lower I/O toggle rates and situations in which the device is in an idle state, lifetimes are increased. Figure 1–1 shows the methodology to determine the overshoot duration. Figure 1–1. Cyclone III Devices Overshoot Duration 4.2 V 4.1 V 3.3 V ΔT T July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–4 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics Recommended Operating Conditions This section lists the functional operation limits for AC and DC parameters for Cyclone III devices. The steady-state voltage and current values expected from Cyclone III devices are provided in Table 1–3. All supplies must be strictly monotonic without plateaus. Table 1–3. Cyclone III Devices Recommended Operating Conditions Symbol Conditions Min Typ Max Unit Supply voltage for internal logic — 1.15 1.2 1.25 V Supply voltage for output buffers, 3.3-V operation — 3.135 3.3 3.465 V Supply voltage for output buffers, 3.0-V operation — 2.85 3 3.15 V Supply voltage for output buffers, 2.5-V operation — 2.375 2.5 2.625 V Supply voltage for output buffers, 1.8-V operation — 1.71 1.8 1.89 V Supply voltage for output buffers, 1.5-V operation — 1.425 1.5 1.575 V Supply voltage for output buffers, 1.2-V operation — 1.14 1.2 1.26 V Supply (analog) voltage for PLL regulator — 2.375 2.5 2.625 V Supply (digital) voltage for PLL — 1.15 1.2 1.25 V VI Input voltage — –0.5 — 3.6 V VO Output voltage — 0 — VCCIO V VCCINT VCCIO VCCA (3) (3), (4) (3) VCCD_PLL TJ tRAMP (3) Parameter (1), (2) Operating junction temperature Power supply ramp time For commercial use 0 — 85 °C For industrial use –40 — 100 °C For extended temperature –40 — 125 °C For automotive use –40 — 125 °C Standard power-on reset (POR) (5) 50 µs — 50 ms — 50 µs — 3 ms — — — 10 mA Fast POR IDiode Magnitude of DC current across PCI-clamp diode when enabled (6) — Notes to Table 1–3: (1) VCCIO for all I/O banks must be powered up during device operation. All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and must be powered up and powered down at the same time. (2) VCCD_PLL must always be connected to VCCINT through a decoupling capacitor and ferrite bead. (3) The VCC must rise monotonically. (4) All input buffers are powered by the VCCIO supply. (5) POR time for Standard POR ranges between 50–200 ms. Each individual power supply should reach the recommended operating range within 50 ms. (6) POR time for Fast POR ranges between 3–9 ms. Each individual power supply should reach the recommended operating range within 3 ms. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1–5 DC Characteristics This section lists the I/O leakage current, pin capacitance, on-chip termination (OCT) tolerance, and bus hold specifications for Cyclone III devices. Supply Current Standby current is the current the device draws after the device is configured with no inputs or outputs toggling and no activity in the device. Use the Excel-based early power estimator (EPE) to get the supply current estimates for your design because these currents vary largely with the resources used. Table 1–4 lists I/O pin leakage current for Cyclone III devices. f For more information about power estimation tools, refer to the PowerPlay Early Power Estimator User Guide and the PowerPlay Power Analysis chapter in the Quartus II Handbook. Table 1–4. Cyclone III Devices I/O Pin Leakage Current (1), Symbol Parameter (2) Conditions Min Typ Max Unit II Input pin leakage current VI = 0 V to VCCIOMAX –10 — 10 A IOZ Tristated I/O pin leakage current VO = 0 V to VCCIOMAX –10 — 10 A Notes to Table 1–4: (1) This value is specified for normal device operation. The value varies during device power-up. This applies for all VCCIO settings (3.3, 3.0, 2.5, 1.8, 1.5, and 1.2 V). (2) 10 A I/O leakage current limit is applicable when the internal clamping diode is off. A higher current can be the observed when the diode is on. Bus Hold Bus hold retains the last valid logic state after the source driving it either enters the high impedance state or is removed. Each I/O pin has an option to enable bus hold in user mode. Bus hold is always disabled in configuration mode. Table 1–5 lists bus hold specifications for Cyclone III devices. Table 1–5. Cyclone III Devices Bus Hold Parameter (Part 1 of 2) (1) VCCIO (V) Parameter Condition 1.2 1.5 1.8 2.5 3.0 3.3 Unit Min Max Min Max Min Max Min Max Min Max Min Max Bus-hold low, sustaining current VIN > VIL (maximum) 8 — 12 — 30 — 50 — 70 — 70 — A Bus-hold high, sustaining current VIN < VIL (minimum) –8 — –12 — –30 — –50 — –70 — –70 — A July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–6 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics Table 1–5. Cyclone III Devices Bus Hold Parameter (1) (Part 2 of 2) VCCIO (V) Parameter Condition 1.2 1.5 1.8 2.5 3.0 3.3 Unit Min Max Min Max Min Max Min Max Min Max Min Max Bus-hold low, overdrive current 0 V < VIN < VCCIO — 125 — 175 — 200 — 300 — 500 — 500 A Bus-hold high, overdrive current 0 V < VIN < VCCIO — –125 — –175 — –200 — –300 — –500 — –500 A — 0.3 0.9 0.68 1.07 0.7 1.7 0.8 2 0.8 2 V Bus-hold trip point 0.375 1.125 Note to Table 1–5: (1) The bus-hold trip points are based on calculated input voltages from the JEDEC standard. OCT Specifications Table 1–6 lists the variation of OCT without calibration across process, temperature, and voltage. Table 1–6. Cyclone III Devices Series OCT without Calibration Specifications Resistance Tolerance Description Series OCT without calibration VCCIO (V) Commercial Max Industrial and Automotive Max Unit 3.0 ±30 ±40 % 2.5 ±30 ±40 % 1.8 +40 ±50 % 1.5 +50 ±50 % 1.2 +50 ±50 % OCT calibration is automatically performed at device power-up for OCT enabled I/Os. Table 1–7 lists the OCT calibration accuracy at device power-up. Table 1–7. Cyclone III Devices Series OCT with Calibration at Device Power-Up Specifications Calibration Accuracy Description Series OCT with calibration at device power-up Cyclone III Device Handbook Volume 2 VCCIO (V) Industrial and Automotive Max Unit Commercial Max 3.0 ±10 ±10 % 2.5 ±10 ±10 % 1.8 ±10 ±10 % 1.5 ±10 ±10 % 1.2 ±10 ±10 % July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1–7 The OCT resistance may vary with the variation of temperature and voltage after calibration at device power-up. Use Table 1–8 and Equation 1–1 to determine the final OCT resistance considering the variations after calibration at device power-up. Table 1–8 lists the change percentage of the OCT resistance with voltage and temperature. Table 1–8. Cyclone III Devices OCT Variation After Calibration at Device Power-Up Nominal Voltage dR/dT (%/°C) dR/dV (%/mV) 3.0 0.262 –0.026 2.5 0.234 –0.039 1.8 0.219 –0.086 1.5 0.199 –0.136 1.2 0.161 –0.288 Equation 1–1. (1), (2), (3), (4), (5), (6) RV = (V2 – V1) × 1000 × dR/dV RT = (T2 – T1) × dR/dT For Rx < 0; MFx = 1/ (|Rx|/100 + 1) For Rx > 0; MFx = Rx/100 + 1 (7) (8) (9) (10) MF = MFV × MFT (11) Rfinal = Rinitial × MF (12) Notes to Equation 1–1: (1) T2 is the final temperature. (2) T1 is the initial temperature. (3) MF is multiplication factor. (4) Rfinal is final resistance. (5) Rinitial is initial resistance. (6) Subscript × refers to both V and T. (7) RV is variation of resistance with voltage. (8) RT is variation of resistance with temperature. (9) dR/dT is the change percentage of resistance with temperature after calibration at device power-up. (10) dR/dV is the change percentage of resistance with voltage after calibration at device power-up. (11) V2 is final voltage. (12) V1 is the initial voltage. July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–8 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics Example 1–1 shows you the example to calculate the change of 50 I/O impedance from 25°C at 3.0 V to 85°C at 3.15 V: Example 1–1. RV = (3.15 – 3) × 1000 × –0.026 = –3.83 RT = (85 – 25) × 0.262 = 15.72 Because RV is negative, MFV = 1 / (3.83/100 + 1) = 0.963 Because RT is positive, MFT = 15.72/100 + 1 = 1.157 MF = 0.963 × 1.157 = 1.114 Rfinal = 50 × 1.114 = 55.71  Pin Capacitance Table 1–9 lists the pin capacitance for Cyclone III devices. Table 1–9. Cyclone III Devices Pin Capacitance Symbol Parameter Typical – QFP Typical – FBGA Unit CIOTB Input capacitance on top/bottom I/O pins 7 6 pF CIOLR Input capacitance on left/right I/O pins 7 5 pF CLVDSLR Input capacitance on left/right I/O pins with dedicated LVDS output 8 7 pF Input capacitance on left/right dual-purpose VREF pin when used as VREF or user I/O pin 21 21 pF CVREFLR (1) CVREFTB (1) Input capacitance on top/bottom dual-purpose VREF pin when used as VREF or user I/O pin CCLKTB Input capacitance on top/bottom dedicated clock input pins 7 6 pF CCLKLR Input capacitance on left/right dedicated clock input pins 6 5 pF 23 (2) 23 (2) pF Notes to Table 1–9: (1) When VREF pin is used as regular input or output, a reduced performance of toggle rate and tCO is expected due to higher pin capacitance. (2) CVREFTB for EP3C25 is 30 pF. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1–9 Internal Weak Pull-Up and Weak Pull-Down Resistor Table 1–10 lists the weak pull-up and pull-down resistor values for Cyclone III devices. (1) Table 1–10. Cyclone III Devices Internal Weak Pull-Up and Weak Pull-Down Resistor Symbol R_PU R_PD Parameter Conditions Value of I/O pin pull-up resistor before and during configuration, as well as user mode if the programmable pull-up resistor option is enabled Value of I/O pin pull-down resistor before and during configuration Min Typ Max Unit VCCIO = 3.3 V ± 5% (2), (3) 7 25 41 k VCCIO = 3.0 V ± 5% (2), (3) 7 28 47 k VCCIO = 2.5 V ± 5% (2), (3) 8 35 61 k VCCIO = 1.8 V ± 5% (2), (3) 10 57 108 k VCCIO = 1.5 V ± 5% (2), (3) 13 82 163 k VCCIO = 1.2 V ± 5% (2), (3) 19 143 351 k VCCIO = 3.3 V ± 5% (4) 6 19 30 k VCCIO = 3.0 V ± 5% (4) 6 22 36 k VCCIO = 2.5 V ± 5% (4) 6 25 43 k VCCIO = 1.8 V ± 5% (4) 7 35 71 k VCCIO = 1.5 V ± 5% (4) 8 50 112 k Notes to Table 1–10: (1) All I/O pins have an option to enable weak pull-up except configuration, test, and JTAG pin. Weak pull-down feature is only available for JTAG TCK. (2) Pin pull-up resistance values may be lower if an external source drives the pin higher than VCCIO. (3) R_PU = (VCCIO – VI)/IR_PU Minimum condition: –40°C; VCCIO = VCC + 5%, VI = VCC + 5% – 50 mV; Typical condition: 25°C; VCCIO = VCC, VI = 0 V; Maximum condition: 125°C; VCCIO = VCC – 5%, VI = 0 V; in which VI refers to the input voltage at the I/O pin. (4) R_PD = VI/IR_PD Minimum condition: –40°C; VCCIO = VCC + 5%, VI = 50 mV; Typical condition: 25°C; VCCIO = VCC, VI = VCC – 5%; Maximum condition: 125°C; VCCIO = VCC – 5%, VI = VCC – 5%; in which VI refers to the input voltage at the I/O pin. Hot Socketing Table 1–11 lists the hot-socketing specifications for Cyclone III devices. Table 1–11. Cyclone III Devices Hot-Socketing Specifications Symbol Parameter Maximum IIOPIN(DC) DC current per I/O pin 300 A IIOPIN(AC) AC current per I/O pin 8 mA (1) Note to Table 1–11: (1) The I/O ramp rate is 10 ns or more. For ramp rates faster than 10 ns, |IIOPIN| = C dv/dt, in which C is I/O pin capacitance and dv/dt is the slew rate. July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–10 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics Schmitt Trigger Input Cyclone III devices support Schmitt trigger input on TDI, TMS, TCK, nSTATUS, nCONFIG, nCE, CONF_DONE, and DCLK pins. A Schmitt trigger feature introduces hysteresis to the input signal for improved noise immunity, especially for signal with slow edge rate. Table 1–12 lists the hysteresis specifications across supported VCCIO range for Schmitt trigger inputs in Cyclone III devices. Table 1–12. Hysteresis Specifications for Schmitt Trigger Input in Cyclone III Devices Symbol Parameter Hysteresis for Schmitt trigger input VSCHMITT Conditions Minimum Typical Maximum Unit VCCIO = 3.3 V 200 — — mV VCCIO = 2.5 V 200 — — mV VCCIO = 1.8 V 140 — — mV VCCIO = 1.5 V 110 — — mV I/O Standard Specifications The following tables list input voltage sensitivities (VIH and VIL), output voltage (VOH and VOL), and current drive characteristics (IOH and IOL) for various I/O standards supported by Cyclone III devices. Table 1–13 through Table 1–18 provide the I/O standard specifications for Cyclone III devices. (1), (2) Table 1–13. Cyclone III Devices Single-Ended I/O Standard Specifications VCCIO (V) VIL (V) VIH (V) VOL (V) VOH (V) IOH (mA) Min Typ Max Min Max Min Max Max Min IOL (mA) 3.135 3.3 3.465 — 0.8 1.7 3.6 0.45 2.4 4 –4 3.135 3.3 3.465 — 0.8 1.7 3.6 0.2 VCCIO – 0.2 2 –2 2.85 3.0 3.15 –0.3 0.8 1.7 VCCIO + 0.3 0.45 2.4 4 –4 2.85 3.0 3.15 –0.3 0.8 1.7 VCCIO + 0.3 0.2 VCCIO – 0.2 0.1 –0.1 2.5-V LVTTL and LVCMOS (3) 2.375 2.5 2.625 –0.3 0.7 1.7 3.6 0.4 2.0 1 –1 1.8-V LVTTL and LVCMOS 1.71 1.8 1.89 –0.3 0.35 * VCCIO 0.65 * VCCIO 2.25 0.45 VCCIO – 0.45 2 –2 1.5-V LVCMOS 1.425 1.5 1.575 –0.3 0.35 * VCCIO 0.65 * VCCIO VCCIO + 0.3 0.25 * VCCIO 0.75 * VCCIO 2 –2 1.2-V LVCMOS 1.14 1.2 1.26 –0.3 0.35 * VCCIO 0.65 * VCCIO VCCIO + 0.3 0.25 * VCCIO 0.75 * VCCIO 2 –2 3.0-V PCI 2.85 3.0 3.15 — 0.3 * VCCIO 0.5 * VCCIO VCCIO + 0.3 0.1 * VCCIO 0.9 * VCCIO 1.5 –0.5 3.0-V PCI-X 2.85 3.0 3.15 — 0.35* VCCIO 0.5 * VCCIO VCCIO + 0.3 0.1 * VCCIO 0.9 * VCCIO 1.5 –0.5 I/O Standard 3.3-V LVTTL (3) 3.3-V LVCMOS 3.0-V LVTTL (3) (3) 3.0-V LVCMOS (3) Notes to Table 1–13: (1) For voltage referenced receiver input waveform and explanation of terms used in Table 1–13, refer to “Single-ended Voltage referenced I/O Standard” in “Glossary” on page 1–27. (2) AC load CL = 10 pF. (3) For more detail about interfacing Cyclone III devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O standards, refer to AN 447: Interfacing Cyclone III Devices with 3.3/3.0/2.5-V LVTTL and LVCMOS I/O Systems. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1–11 Table 1–14. Cyclone III Devices Single-Ended SSTL and HSTL I/O Reference Voltage Specifications I/O Standard VCCIO (V) (1) VREF (V) (2) VTT (V) Min Typ Max Min Typ Max Min Typ Max SSTL-2 Class I, II 2.375 2.5 2.625 1.19 1.25 1.31 VREF – 0.04 VREF VREF + 0.04 SSTL-18 Class I, II 1.7 1.8 1.9 0.833 0.9 0.969 VREF – 0.04 VREF VREF + 0.04 HSTL-18 Class I, II 1.71 1.8 1.89 0.85 0.9 0.95 0.85 0.9 0.95 HSTL-15 Class I, II 1.425 1.5 1.575 0.71 0.75 0.79 0.71 0.75 0.79 HSTL-12 Class I, II 1.14 1.2 1.26 0.48 * VCCIO (3) 0.5 * VCCIO (3) 0.52 * VCCIO (3) 0.47 * VCCIO (4) 0.5 * VCCIO (4) 0.53 * VCCIO (4) 0.5 * VCCIO — — Notes to Table 1–14: (1) For an explanation of terms used in Table 1–14, refer to “Glossary” on page 1–27. (2) VTT of transmitting device must track VREF of the receiving device. (3) Value shown refers to DC input reference voltage, VREF(DC). (4) Value shown refers to AC input reference voltage, VREF(AC). Table 1–15. Cyclone III Devices Single-Ended SSTL and HSTL I/O Standards Signal Specifications I/O Standard VIL(DC) (V) VIH(DC) (V) VIL(AC) (V) VIH(AC) (V) VOL (V) VOH (V) IOL (mA) IOH (mA) Min Max Min Max Min Max Min Max Max Min SSTL-2 Class I — VREF – 0.18 VREF + 0.18 — — VREF – 0.35 VREF + 0.35 — VTT – 0.57 VTT + 0.57 8.1 –8.1 SSTL-2 Class II — VREF – 0.18 VREF + 0.18 — — VREF – 0.35 VREF + 0.35 — VTT – 0.76 VTT + 0.76 16.4 –16.4 SSTL-18 Class I — VREF – 0.125 VREF + 0.125 — — VREF – 0.25 VREF + 0.25 — VTT – 0.475 VTT + 0.475 6.7 –6.7 SSTL-18 Class II — VREF – 0.125 VREF + 0.125 — — VREF – 0.25 VREF + 0.25 — 0.28 VCCIO – 0.28 13.4 –13.4 HSTL-18 Class I — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VCCIO – 0.4 8 –8 HSTL-18 Class II — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VCCIO – 0.4 16 –16 HSTL-15 Class I — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VCCIO – 0.4 8 –8 HSTL-15 Class II — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VCCIO – 0.4 16 –16 HSTL-12 Class I –0.15 VREF – 0.08 VREF + 0.08 VCCIO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VCCIO + 0.24 0.25 × VCCIO 0.75 × VCCIO 8 –8 HSTL-12 Class II –0.15 VREF – 0.08 VREF + 0.08 VCCIO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VCCIO + 0.24 0.25 × VCCIO 0.75 × VCCIO 14 –14 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–12 Chapter 1: Cyclone III Device Datasheet Electrical Characteristics f For more illustrations of receiver input and transmitter output waveforms, and for other differential I/O standards, refer to the High-Speed Differential Interfaces in Cyclone III Devices chapter. Table 1–16. Cyclone III Devices Differential SSTL I/O Standard Specifications (1) VCCIO (V) I/O Standard SSTL-2 Class I, II SSTL-18 Class I, II VSwing(DC) (V) Min Typ Max 2.375 2.5 2.625 0.36 VCCIO VCCIO/2 – 0.2 1.7 1.8 1.90 Min Max 0.25 VCCIO VSwing(AC) (V) VX(AC) (V) Min VCCIO/2 – 0.175 Typ Max — VCCIO/2 + 0.2 — VCCIO/2 + 0.175 VOX(AC) (V) Min Max 0.7 VCCI 0.5 VCCI O O Min Typ Max VCCIO/2 – 0.125 — VCCIO/2 + 0.125 VCCIO/2 – 0.125 — VCCIO/2 + 0.125 Note to Table 1–16: (1) Differential SSTL requires a VREF input. Table 1–17. Cyclone III Devices Differential HSTL I/O Standard Specifications (1) VCCIO (V) VDIF(DC) (V) VX(AC) (V) VCM(DC) (V) VDIF(AC) (V) I/O Standard Min Typ Max Min Max Min Typ Max Min Typ Max Mi n Max HSTL-18 Class I, II 1.71 1.8 1.89 0.2 — 0.85 — 0.95 0.85 — 0.95 0.4 — HSTL-15 Class I, II 1.425 1.5 1.575 0.2 — 0.71 — 0.79 0.71 — 0.79 0.4 — HSTL-12 Class I, II 1.14 1.2 1.26 0.16 VCCIO 0.48 * VCCIO — 0.52 * VCCIO 0.48 * VCCIO — 0.52 * VCCIO 0.3 0.48 * VCCIO Note to Table 1–17: (1) Differential HSTL requires a VREF input. Table 1–18. Cyclone III Devices Differential I/O Standard Specifications I/O Standard LVPECL (Row I/Os) VCCIO (V) Min 2.375 Typ 2.5 VID (mV) Max 2.625 Min 100 Max — VIcM (V) Min LVDS (Row I/Os) 2.375 2.375 2.5 2.5 2.625 2.625 100 100 — — (2) Condition VOD (mV) Max Min Typ 1.80 500 Mbps  DMAX  700 Mbps 1.80 1.05 DMAX > 700 Mbps 1.55 0.05 DMAX 500 Mbps 1.80 500 Mbps  DMAX 700 Mbps 1.80 1.05 DMAX > 700 Mbps 1.55 0.05 DMAX 500 Mbps 1.80 0.55 0.55 0.55 500 Mbps  DMAX  700 Mbps 1.05 DMAX > 700 Mbps Cyclone III Device Handbook Volume 2 (Part 1 of 2) 0.05 DMAX500 Mbps (4) LVPECL (Column I/Os) (4) (1) (3) VOS (V) (3) Max Min Typ Max — — — — — — — — — — — — 1.80 247 — 600 1.125 1.25 1.375 1.55 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Electrical Characteristics 1–13 Table 1–18. Cyclone III Devices Differential I/O Standard Specifications I/O Standard VCCIO (V) Min Typ VID (mV) Max Min Max VIcM (V) Min (1) (Part 2 of 2) (2) Condition 0.05 DMAX  500 Mbps LVDS (Column I/Os) 2.375 2.5 2.625 100 — 0.55 500 Mbps  DMAX  700 Mbps 1.05 DMAX > 700 Mbps BLVDS (Row I/Os) VOD (mV) Max Min Typ (3) Max VOS (V) Min Typ (3) Max 1.80 1.80 247 — 600 1.125 1.25 1.375 1.55 2.375 2.5 2.625 100 — — — — — — — — — — 2.375 2.5 2.625 100 — — — — — — — — — — 2.375 2.5 2.625 — — — — — 300 — 600 1.0 1.2 1.4 mini-LVDS (Column I/Os) (6) 2.375 2.5 2.625 — — — — — 300 — 600 1.0 1.2 1.4 RSDS® (Row I/Os) (6) 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.5 RSDS (Column I/Os) (6) 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.5 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.4 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.4 (5) BLVDS (Column I/Os) (5) mini-LVDS (Row I/Os) (6) PPDS® (Row I/Os) (6) PPDS (Column I/Os) (6) Notes to Table 1–18: (1) For an explanation of terms used in Table 1–18, refer to “Transmitter Output Waveform” in “Glossary” on page 1–27. (2) VIN range: 0 V  VIN  1.85 V. (3) RL range: 90  RL  110  . (4) LVPECL input standard is only supported at clock input. Output standard is not supported. (5) No fixed VIN , VOD , and VOS specifications for BLVDS. They are dependent on the system topology. (6) Mini-LVDS, RSDS, and PPDS standards are only supported at the output pins for Cyclone III devices. July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–14 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Power Consumption You can use the following methods to estimate power for a design: ■ the Excel-based EPE. ■ the Quartus II PowerPlay power analyzer feature. The interactive Excel-based EPE is used prior to designing the device to get a magnitude estimate of the device power. The Quartus II PowerPlay power analyzer provides better quality estimates based on the specifics of the design after place-androute is complete. The PowerPlay power analyzer can apply a combination of userentered, simulation-derived, and estimated signal activities which, combined with detailed circuit models, can yield very accurate power estimates. f For more information about power estimation tools, refer to the Early Power Estimator User Guide and the PowerPlay Power Analysis chapter in volume 3 of the Quartus II Handbook. Switching Characteristics This section provides the performance characteristics of the core and periphery blocks for Cyclone III devices. All data is final and is based on actual silicon characterization and testing. These numbers reflect the actual performance of the device under worst-case silicon process, voltage, and junction temperature conditions. Core Performance Specifications Clock Tree Specifications Table 1–19 lists the clock tree specifications for Cyclone III devices. Table 1–19. Cyclone III Devices Clock Tree Performance Performance Device Unit C6 C7 C8 EP3C5 500 437.5 402 MHz EP3C10 500 437.5 402 MHz EP3C16 500 437.5 402 MHz EP3C25 500 437.5 402 MHz EP3C40 500 437.5 402 MHz EP3C55 500 437.5 402 MHz EP3C80 500 437.5 402 MHz (1) 437.5 402 MHz EP3C120 Note to Table 1–19: (1) EP3C120 offered in C7, C8, and I7 grades only. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–15 PLL Specifications Table 1–20 describes the PLL specifications for Cyclone III devices when operating in the commercial junction temperature range (0°C to 85°C), the industrial junction temperature range (–40°C to 100°C), and the automotive junction temperature range (–40°Cto 125°C). For more information about PLL block, refer to “PLL Block” in “Glossary” on page 1–27. Table 1–20. Cyclone III Devices PLL Specifications (1) Symbol fIN Parameter (2) fINPFD fVCO (3) fINDUTY tINJITTER_CCJ (Part 1 of 2) (4) fOUT_EXT (external clock output) (2) fOUT (to global clock) Min Typ Max Unit Input clock frequency 5 — 472.5 MHz PFD input frequency 5 — 325 MHz PLL internal VCO operating range 600 — 1300 MHz Input clock duty cycle 40 — 60 % Input clock cycle-to-cycle jitter for FINPFD  100 MHz — — 0.15 UI Input clock cycle-to-cycle jitter for FINPFD < 100 MHz — — ±750 ps PLL output frequency — — 472.5 MHz PLL output frequency (–6 speed grade) — — 472.5 MHz PLL output frequency (–7 speed grade) — — 450 MHz PLL output frequency (–8 speed grade) — — 402.5 MHz tOUTDUTY Duty cycle for external clock output (when set to 50%) 45 50 55 % tLOCK Time required to lock from end of device configuration — — 1 ms tDLOCK Time required to lock dynamically (after switchover, reconfiguring any non-post-scale counters/delays or areset is deasserted) — — 1 ms Dedicated clock output period jitter FOUT  100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI Dedicated clock output cycle-to-cycle jitter FOUT  100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI Regular I/O period jitter FOUT  100 MHz — — 650 ps FOUT < 100 MHz — — 75 mUI Regular I/O cycle-to-cycle jitter FOUT  100 MHz — — 650 ps tOUTJITTER_PERIOD_DEDCLK tOUTJITTER_CCJ_DEDCLK tOUTJITTER_PERIOD_IO tOUTJITTER_CCJ_IO (5) (5) (5) (5) FOUT < 100 MHz — — 75 mUI tPLL_PSERR Accuracy of PLL phase shift — — ±50 ps tARESET Minimum pulse width on areset signal. 10 — — ns tCONFIGPLL Time required to reconfigure scan chains for PLLs — — SCANCLK cycles July 2012 Altera Corporation 3.5 (6) Cyclone III Device Handbook Volume 2 1–16 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Table 1–20. Cyclone III Devices PLL Specifications (1) Symbol (Part 2 of 2) Parameter fSCANCLK Min Typ Max Unit — — 100 MHz scanclk frequency Notes to Table 1–20: (1) VCCD_PLL should always be connected to VCCINT through decoupling capacitor and ferrite bead. (2) This parameter is limited in the Quartus II software by the I/O maximum frequency. The maximum I/O frequency is different for each I/O standard. (3) The VCO frequency reported by the Quartus II software in the PLL summary section of the compilation report takes into consideration the VCO post-scale counter K value. Therefore, if the counter K has a value of 2, the frequency reported can be lower than the fVCO specification. (4) A high input jitter directly affects the PLL output jitter. To have low PLL output clock jitter, you must provide a clean clock source, which is less than 200 ps. (5) Peak-to-peak jitter with a probability level of 10–12 (14 sigma, 99.99999999974404% confidence level). The output jitter specification applies to the intrinsic jitter of the PLL, when an input jitter of 30 ps is applied. (6) With 100 MHz scanclk frequency. Embedded Multiplier Specifications Table 1–21 describes the embedded multiplier specifications for Cyclone III devices. Table 1–21. Cyclone III Devices Embedded Multiplier Specifications Resources Used Performance Mode Unit Number of Multipliers C6 C7, I7, A7 C8 9 × 9-bit multiplier 1 340 300 260 MHz 18 × 18-bit multiplier 1 287 250 200 MHz Memory Block Specifications Table 1–22 describes the M9K memory block specifications for Cyclone III devices. Table 1–22. Cyclone III Devices Memory Block Performance Specifications Resources Used Memory M9K Block Mode Performance LEs M9K Memory C6 C7, I7, A7 C8 Unit FIFO 256 × 36 47 1 315 274 238 MHz Single-port 256 × 36 0 1 315 274 238 MHz Simple dual-port 256 × 36 CLK 0 1 315 274 238 MHz True dual port 512 × 18 single CLK 0 1 315 274 238 MHz Configuration and JTAG Specifications Table 1–23 lists the configuration mode specifications for Cyclone III devices. Table 1–23. Cyclone III Devices Configuration Mode Specifications Programming Mode DCLK Fmax Unit 133 MHz 100 MHz Passive Serial (PS) Fast Passive Parallel (FPP) (1) Note to Table 1–23: (1) EP3C40 and smaller density members support 133 MHz. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–17 Table 1–24 lists the active configuration mode specifications for Cyclone III devices. Table 1–24. Cyclone III Devices Active Configuration Mode Specifications Programming Mode DCLK Range Unit Active Parallel (AP) 20 – 40 MHz Active Serial (AS) 20 – 40 MHz Table 1–25 lists the JTAG timing parameters and values for Cyclone III devices. Table 1–25. Cyclone III Devices JTAG Timing Parameters Symbol Parameter (1) Min Max Unit tJCP TCK clock period 40 — ns tJCH TCK clock high time 20 — ns tJCL TCK clock low time 20 — ns tJPSU_TDI JTAG port setup time for TDI 1 — ns tJPSU_TMS JTAG port setup time for TMS 3 — ns tJPH 10 — ns tJPCO tJPZX JTAG port hold time JTAG port clock to output (2) — 15 ns output (2) — 15 ns impedance (2) JTAG port high impedance to valid tJPXZ JTAG port valid output to high — 15 ns tJSSU Capture register setup time 5 — ns tJSH Capture register hold time 10 — ns tJSCO Update register clock to output — 25 ns tJSZX Update register high impedance to valid output — 25 ns tJSXZ Update register valid output to high impedance — 25 ns Notes to Table 1–25: (1) For more information about JTAG waveforms, refer to “JTAG Waveform” in “Glossary” on page 1–27. (2) The specification is shown for 3.3-, 3.0-, and 2.5-V LVTTL/LVCMOS operation of JTAG pins. For 1.8-V LVTTL/LVCMOS and 1.5-V LVCMOS, the JTAG port clock to output time is 16 ns. Periphery Performance This section describes periphery performance, including high-speed I/O, external memory interface, and IOE programmable delay. I/O performance supports several system interfacing, for example, the high-speed I/O interface, external memory interface, and the PCI/PCI-X bus interface. I/O using the SSTL-18 Class I termination standard can achieve up to the stated DDR2 SDRAM interfacing speeds with typical DDR SDRAM memory interface setup. I/O using general-purpose I/O standards such as 3.0-, 2.5-, 1.8-, or 1.5-LVTTL/LVCMOS are capable of a typical 200 MHz interfacing frequency with a 10 pF load. 1 July 2012 Actual achievable frequency depends on design- and system-specific factors. Perform HSPICE/IBIS simulations based on your specific design and system setup to determine the maximum achievable frequency in your system. Altera Corporation Cyclone III Device Handbook Volume 2 1–18 Chapter 1: Cyclone III Device Datasheet Switching Characteristics High-Speed I/O Specifications Table 1–26 through Table 1–31 list the high-speed I/O timing for Cyclone III devices. For definitions of high-speed timing specifications, refer to “Glossary” on page 1–27. Table 1–26. Cyclone III Devices RSDS Transmitter Timing Specifications C6 Symbol (1), (2) C7, I7 C8, A7 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 5 — 180 5 — 155.5 5 — 155.5 MHz ×8 5 — 180 5 — 155.5 5 — 155.5 MHz ×7 5 — 180 5 — 155.5 5 — 155.5 MHz ×4 5 — 180 5 — 155.5 5 — 155.5 MHz ×2 5 — 180 5 — 155.5 5 — 155.5 MHz ×1 5 — 360 5 — 311 5 — 311 MHz ×10 100 — 360 100 — 311 100 — 311 Mbps ×8 80 — 360 80 — 311 80 — 311 Mbps ×7 70 — 360 70 — 311 70 — 311 Mbps ×4 40 — 360 40 — 311 40 — 311 Mbps ×2 20 — 360 20 — 311 20 — 311 Mbps ×1 10 — 360 10 — 311 10 — 311 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps fHSCLK (input clock frequency) Device operation in Mbps tRISE 20 – 80%, CLOAD = 5 pF — 500 — — 500 — — 500 — ps tFALL 20 – 80%, CLOAD = 5 pF — 500 — — 500 — — 500 — ps — — 1 — — 1 — — 1 ms tLOCK (3) — Notes to Table 1–26: (1) Applicable for true RSDS and emulated RSDS_E_3R transmitter. (2) True RSDS transmitter is only supported at output pin of Row I/O (Banks 1, 2, 5, and 6). Emulated RSDS transmitter is supported at the output pin of all I/O banks. (3) tLOCK is the time required for the PLL to lock from the end of device configuration. Table 1–27. Cyclone III Devices Emulated RSDS_E_1R Transmitter Timing Specifications (1) (Part 1 of 2) C6 Symbol fHSCLK (input clock frequency) C7, I7 C8, A7 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 5 — 85 5 — 85 5 — 85 MHz ×8 5 — 85 5 — 85 5 — 85 MHz ×7 5 — 85 5 — 85 5 — 85 MHz ×4 5 — 85 5 — 85 5 — 85 MHz ×2 5 — 85 5 — 85 5 — 85 MHz ×1 5 — 170 5 — 170 5 — 170 MHz Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–19 Table 1–27. Cyclone III Devices Emulated RSDS_E_1R Transmitter Timing Specifications (1) (Part 2 of 2) C6 Symbol C7, I7 C8, A7 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 100 — 170 100 — 170 100 — 170 Mbps ×8 80 — 170 80 — 170 80 — 170 Mbps ×7 70 — 170 70 — 170 70 — 170 Mbps ×4 40 — 170 40 — 170 40 — 170 Mbps ×2 20 — 170 20 — 170 20 — 170 Mbps ×1 10 — 170 10 — 170 10 — 170 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps — 500 — — 500 — — 500 — ps — 500 — — 500 — — 500 — ps — — 1 — — 1 — — 1 ms Device operation in Mbps 20 – 80%, tRISE CLOAD = 5 pF 20 – 80%, tFALL tLOCK CLOAD = 5 pF (2) — Notes to Table 1–27: (1) Emulated RSDS_E_1R transmitter is supported at the output pin of all I/O banks. (2) tLOCK is the time required for the PLL to lock from the end of device configuration. Table 1–28. Cyclone III Devices Mini-LVDS Transmitter Timing Specifications (1), C6 Symbol fHSCLK (input clock frequency) Device operation in Mbps (2) (Part 1 of 2) C7, I7 C8, A7 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 5 — 200 5 — 155.5 5 — 155.5 MHz ×8 5 — 200 5 — 155.5 5 — 155.5 MHz ×7 5 — 200 5 — 155.5 5 — 155.5 MHz ×4 5 — 200 5 — 155.5 5 — 155.5 MHz ×2 5 — 200 5 — 155.5 5 — 155.5 MHz ×1 5 — 400 5 — 311 5 — 311 MHz ×10 100 — 400 100 — 311 100 — 311 Mbps ×8 80 — 400 80 — 311 80 — 311 Mbps ×7 70 — 400 70 — 311 70 — 311 Mbps ×4 40 — 400 40 — 311 40 — 311 Mbps ×2 20 — 400 20 — 311 20 — 311 Mbps ×1 10 — 400 10 — 311 10 — 311 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–20 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Table 1–28. Cyclone III Devices Mini-LVDS Transmitter Timing Specifications (1), C6 Symbol tLOCK — 20 – 80%, CLOAD = 5 pF 20 – 80%, tFALL (Part 2 of 2) C7, I7 C8, A7 Modes Output jitter (peak to peak) tRISE (2) CLOAD = 5 pF (3) — Unit Min Typ Max Min Typ Max Min Typ Max — — 500 — — 500 — — 550 ps — 500 — — 500 — — 500 — ps — 500 — — 500 — — 500 — ps — — 1 — — 1 — — 1 ms Notes to Table 1–28: (1) Applicable for true and emulated mini-LVDS transmitter. (2) True mini-LVDS transmitter is only supported at the output pin of Row I/O (Banks 1, 2, 5, and 6). Emulated mini-LVDS transmitter is supported at the output pin of all I/O banks. (3) tLOCK is the time required for the PLL to lock from the end of device configuration. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–21 Table 1–29. Cyclone III Devices True LVDS Transmitter Timing Specifications (1) C6 Symbol fHSCLK (input clock frequency) C7, I7 C8, A7 Modes Unit Min Max Min Max Min Max ×10 5 420 5 370 5 320 MHz ×8 5 420 5 370 5 320 MHz ×7 5 420 5 370 5 320 MHz ×4 5 420 5 370 5 320 MHz ×2 5 420 5 370 5 320 MHz ×1 5 420 5 402.5 5 402.5 MHz ×10 100 840 100 740 100 640 Mbps ×8 80 840 80 740 80 640 Mbps ×7 70 840 70 740 70 640 Mbps ×4 40 840 40 740 40 640 Mbps ×2 20 840 20 740 20 640 Mbps ×1 10 420 10 402.5 10 402.5 Mbps tDUTY — 45 55 45 55 45 55 % TCCS — — 200 — 200 — 200 ps Output jitter (peak to peak) — — 500 — 500 — 550 ps — — 1 — 1 — 1 ms HSIODR (2) tLOCK Notes to Table 1–29: (1) True LVDS transmitter is only supported at the output pin of Row I/O (Banks 1, 2, 5, and 6). (2) tLOCK is the time required for the PLL to lock from the end of device configuration. Table 1–30. Cyclone III Devices Emulated LVDS Transmitter Timing Specifications (1) (Part 1 of 2) C6 Symbol C8, A7 Unit Min Max Min Max Min Max ×10 5 320 5 320 5 275 MHz ×8 5 320 5 320 5 275 MHz ×7 5 320 5 320 5 275 MHz ×4 5 320 5 320 5 275 MHz ×2 5 320 5 320 5 275 MHz ×1 5 402.5 5 402.5 5 402.5 MHz ×10 100 640 100 640 100 550 Mbps ×8 80 640 80 640 80 550 Mbps ×7 70 640 70 640 70 550 Mbps ×4 40 640 40 640 40 550 Mbps ×2 20 640 20 640 20 550 Mbps ×1 10 402.5 10 402.5 10 402.5 Mbps tDUTY — 45 55 45 55 45 55 % TCCS — — 200 — 200 — 200 ps fHSCLK (input clock frequency) HSIODR July 2012 C7, I7 Modes Altera Corporation Cyclone III Device Handbook Volume 2 1–22 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Table 1–30. Cyclone III Devices Emulated LVDS Transmitter Timing Specifications (1) (Part 2 of 2) C6 Symbol Output jitter (peak to peak) tLOCK (2) C7, I7 C8, A7 Modes Unit Min Max Min Max Min Max — — 500 — 500 — 550 ps — — 1 — 1 — 1 ms Notes to Table 1–30: (1) Emulated LVDS transmitter is supported at the output pin of all I/O banks. (2) tLOCK is the time required for the PLL to lock from the end of device configuration. Table 1–31. Cyclone III Devices LVDS Receiver Timing Specifications C6 Symbol (1) C7, I7 C8, A7 Modes Unit Min Max Min Max Min Max ×10 5 437.5 5 370 5 320 MHz ×8 5 437.5 5 370 5 320 MHz ×7 5 437.5 5 370 5 320 MHz ×4 5 437.5 5 370 5 320 MHz ×2 5 437.5 5 370 5 320 MHz ×1 5 437.5 5 402.5 5 402.5 MHz ×10 100 875 100 740 100 640 Mbps ×8 80 875 80 740 80 640 Mbps ×7 70 875 70 740 70 640 Mbps ×4 40 875 40 740 40 640 Mbps ×2 20 875 20 740 20 640 Mbps ×1 10 437.5 10 402.5 10 402.5 Mbps SW — — 400 — 400 — 400 ps Input jitter tolerance — — 500 — 500 — 550 ps — — 1 — 1 — 1 ms fHSCLK (input clock frequency) HSIODR tLOCK (2) Notes to Table 1–31: (1) LVDS receiver is supported at all banks. (2) tLOCK is the time required for the PLL to lock from the end of device configuration. External Memory Interface Specifications Cyclone III devices support external memory interfaces up to 200 MHz. The external memory interfaces for Cyclone III devices are auto-calibrating and easy to implement. f For more information about external memory system performance specifications, board design guidelines, timing analysis, simulation, and debugging information, refer to Literature: External Memory Interfaces. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–23 Table 1–32 lists the FPGA sampling window specifications for Cyclone III devices. Table 1–32. Cyclone III Devices FPGA Sampling Window (SW) Requirement – Read Side (1) Column I/Os Row I/Os Wraparound Mode Memory Standard Setup Hold Setup Hold Setup Hold 690 640 850 800 C6 DDR2 SDRAM 580 550 DDR SDRAM 585 535 700 650 870 820 QDRII SRAM 785 735 805 755 905 855 C7 DDR2 SDRAM 705 650 770 715 985 930 DDR SDRAM 675 620 795 740 970 915 QDRII SRAM 900 845 910 855 1085 1030 930 870 1115 1055 C8 DDR2 SDRAM 785 720 DDR SDRAM 800 740 915 855 1185 1125 QDRII SRAM 1050 990 1065 1005 1210 1150 I7 DDR2 SDRAM 765 710 855 800 1040 985 DDR SDRAM 745 690 880 825 1000 945 QDRII SRAM 945 890 955 900 1130 1075 1020 960 1145 1085 A7 DDR2 SDRAM 805 745 DDR SDRAM 880 820 955 935 1220 1160 QDRII SRAM 1090 1030 1105 1045 1250 1190 Note to Table 1–32: (1) Column I/Os refer to top and bottom I/Os. Row I/Os refer to right and left I/Os. Wraparound mode refers to the combination of column and row I/Os. Table 1–33 lists the transmitter channel-to-channel skew specifications for Cyclone III devices. Table 1–33. Cyclone III Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (1) Memory Standard Column I/Os (ps) Row I/Os (ps) (Part 1 of 2) Wraparound Mode (ps) I/O Standard Lead Lag Lead Lag Lead Lag C6 DDR2 SDRAM DDR SDRAM QDRII SRAM SSTL-18 Class I 790 380 790 380 890 480 SSTL-18 Class II 870 490 870 490 970 590 SSTL-2 Class I 750 320 750 320 850 420 SSTL-2 Class II 860 350 860 350 960 450 1.8 V HSTL Class I 780 410 780 410 880 510 1.8 V HSTL Class II 830 510 830 510 930 610 C7 July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–24 Chapter 1: Cyclone III Device Datasheet Switching Characteristics Table 1–33. Cyclone III Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (1) Column I/Os (ps) Memory Standard DDR2 SDRAM DDR SDRAM QDRII SRAM Row I/Os (ps) (Part 2 of 2) Wraparound Mode (ps) I/O Standard Lead Lag Lead Lag Lead Lag SSTL-18 Class I 915 410 915 410 1015 510 SSTL-18 Class II 1025 545 1025 545 1125 645 SSTL-2 Class I 880 340 880 340 980 440 SSTL-2 Class II 1010 380 1010 380 1110 480 1.8 V HSTL Class I 910 450 910 450 1010 550 1.8 V HSTL Class II 1010 570 1010 570 1110 670 C8 DDR2 SDRAM DDR SDRAM QDRII SRAM SSTL-18 Class I 1040 440 1040 440 1140 540 SSTL-18 Class II 1180 600 1180 600 1280 700 SSTL-2 Class I 1010 360 1010 360 1110 460 SSTL-2 Class II 1160 410 1160 410 1260 510 1.8 V HSTL Class I 1040 490 1040 490 1140 590 1.8 V HSTL Class II 1190 630 1190 630 1290 730 I7 DDR2 SDRAM DDR SDRAM QDRII SRAM SSTL-18 Class I 961 431 961 431 1061 531 SSTL-18 Class II 1076 572 1076 572 1176 672 SSTL-2 Class I 924 357 924 357 1024 457 SSTL-2 Class II 1061 399 1061 399 1161 499 1.8 V HSTL Class I 956 473 956 473 1056 573 1.8 V HSTL Class II 1061 599 1061 599 1161 699 A7 DDR2 SDRAM SSTL-18 Class I 1092 462 1092 462 1192 562 (2) SSTL-18 Class II 1239 630 1239 630 1339 730 SSTL-2 Class I 1061 378 1061 378 1161 478 SSTL-2 Class II 1218 431 1218 431 1318 531 DDR SDRAM QDRII SRAM 1.8 V HSTL Class I 1092 515 1092 515 1192 615 1.8 V HSTL Class II 1250 662 1250 662 1350 762 Notes to Table 1–33: (1) Column I/O banks refer to top and bottom I/Os. Row I/O banks refer to right and left I/Os. Wraparound mode refers to the combination of column and row I/Os. (2) For DDR2 SDRAM write timing performance on Columns I/O for C8 and A7 devices, 97.5 degree phase offset is required. Table 1–34 lists the memory output clock jitter specifications for Cyclone III devices. Table 1–34. Cyclone III Devices Memory Output Clock Jitter Specifications (1), Parameter (2) (Part 1 of 2) Symbol Min Max Unit Clock period jitter tJIT(per) -125 125 ps Cycle-to-cycle period jitter tJIT(cc) -200 200 ps Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Switching Characteristics 1–25 Table 1–34. Cyclone III Devices Memory Output Clock Jitter Specifications (1), Parameter Duty cycle jitter (2) (Part 2 of 2) Symbol Min Max Unit tJIT(duty) -150 150 ps Notes to Table 1–34: (1) The memory output clock jitter measurements are for 200 consecutive clock cycles, as specified in the JEDEC DDR2 standard. (2) The clock jitter specification applies to memory output clock pins generated using DDIO circuits clocked by a PLL output routed on a global clock network. Duty Cycle Distortion Specifications Table 1–35 lists the worst case duty cycle distortion for Cyclone III devices. (1), (2) Table 1–35. Duty Cycle Distortion on Cyclone III Devices I/O Pins C6 C7, I7 C8, A7 Symbol Unit Output Duty Cycle Min Max Min Max Min Max 45 55 45 55 45 55 % Notes to Table 1–35: (1) Duty cycle distortion specification applies to clock outputs from PLLs, global clock tree, and IOE driving dedicated and general purpose I/O pins. (2) Cyclone III devices meet specified duty cycle distortion at maximum output toggle rate for each combination of I/O standard and current strength. OCT Calibration Timing Specification Table 1–36 lists the duration of calibration for series OCT with calibration at device power-up for Cyclone III devices. Table 1–36. Cyclone III Devices Timing Specification for Series OCT with Calibration at Device Power-Up (1) Symbol Description Maximum Unit 20 µs Duration of series OCT with calibration at device power-up tOCTCAL Notes to Table 1–36: (1) OCT calibration takes place after device configuration, before entering user mode. IOE Programmable Delay Table 1–37 and Table 1–38 list IOE programmable delay for Cyclone III devices. Table 1–37. Cyclone III Devices IOE Programmable Delay on Column Pins (1), (2) (Part 1 of 2) Max Offset Parameter Paths Affected Number of Settings Min Offset Fast Corner Slow Corner Unit A7, I7 C6 C6 C7 C8 I7 A7 Input delay from pin to internal cells Pad to I/O dataout to core 7 0 1.211 1.314 2.175 2.32 2.386 2.366 2.49 ns Input delay from pin to input register Pad to I/O input register 8 0 1.203 1.307 2.19 2.387 2.54 2.43 2.545 ns July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–26 Chapter 1: Cyclone III Device Datasheet I/O Timing Table 1–37. Cyclone III Devices IOE Programmable Delay on Column Pins (1), (2) (Part 2 of 2) Max Offset Paths Affected Parameter Number of Settings Min Offset Fast Corner Slow Corner Unit A7, I7 C6 C6 C7 C8 I7 A7 Delay from output register to output pin I/O output register to pad 2 0 0.479 0.504 0.915 1.011 1.107 1.018 1.048 ns Input delay from dual-purpose clock pin to fan-out destinations Pad to global clock network 12 0 0.664 0.694 1.199 1.378 1.532 1.392 1.441 ns Notes to Table 1–37: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of the Quartus II software. (2) The minimum and maximum offset timing numbers are in reference to setting ‘0’ as available in the Quartus II software. Table 1–38. Cyclone III Devices IOE Programmable Delay on Row Pins (1), (2) Max Offset Paths Affected Parameter Number of Settings Min Offset Fast Corner Slow Corner Unit A7, I7 C6 C6 C7 C8 I7 A7 Input delay from pin to internal cells Pad to I/O dataout to core 7 0 1.209 1.314 2.174 2.335 2.406 2.381 2.505 ns Input delay from pin to input register Pad to I/O input register 8 0 1.207 1.312 2.202 2.402 2.558 2.447 2.557 ns Delay from output register to output pin I/O output register to pad 2 0 0.51 0.537 0.962 1.072 1.167 1.074 1.101 ns 12 0 0.669 0.698 1.207 1.388 1.542 1.403 1.45 ns Input delay from Pad to global dual-purpose clock pin clock network to fan-out destinations Notes to Table 1–38: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of Quartus II software. (2) The minimum and maximum offset timing numbers are in reference to setting ‘0’ as available in the Quartus II software I/O Timing You can use the following methods to determine the I/O timing: ■ the Excel-based I/O Timing. ■ the Quartus II timing analyzer. The Excel-based I/O Timing provides pin timing performance for each device density and speed grade. The data is typically used prior to designing the FPGA to get a timing budget estimation as part of the link timing analysis. The Quartus II timing analyzer provides a more accurate and precise I/O timing data based on the specifics of the design after place-and-route is complete. Cyclone III Device Handbook Volume 2 July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Glossary 1–27 f The Excel-based I/O Timing spreadsheet is downloadable from Cyclone III Devices Literature website. Glossary Table 1–39 lists the glossary for this chapter. Table 1–39. Glossary (Part 1 of 5) Letter Term Definitions A — — B — — C — — D — — E — — F fHSCLK HIGH-SPEED I/O Block: High-speed receiver/transmitter input and output clock frequency. GCLK Input pin directly to Global Clock network. GCLK PLL Input pin to Global Clock network through PLL. H HSIODR HIGH-SPEED I/O Block: Maximum/minimum LVDS data transfer rate (HSIODR = 1/TUI). I Input Waveforms for the SSTL Differential I/O Standard G VIH VSWING VREF VIL TMS TDI t JCP t JCH t JPSU_TDI t JPSU_TMS t JCL t JPH TCK J JTAG Waveform tJPZX t JPXZ t JPCO TDO tJSSU Signal to be Captured tJSZX t JSH t JSCO t JSXZ Signal to be Driven K — — L — — M — — July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–28 Chapter 1: Cyclone III Device Datasheet Glossary Table 1–39. Glossary (Part 2 of 5) Letter Term Definitions N — — O — — The following block diagram highlights the PLL Specification parameters. CLKOUT Pins Switchover fOUT _EXT CLK fIN N fINPFD PFD P PLL Block CP VCO fVCO LF Core Clock Counters C0..C4 fOUT GCLK Phase tap M Key Reconfigurable in User Mode Q — RL — Receiver differential input discrete resistor (external to Cyclone III devices). Receiver Input Waveform for LVDS and LVPECL Differential Standards. Single-Ended Waveform Positive Channel (p) = VIH VID Negative Channel (n) = VIL VCM R Ground Receiver Input Waveform Differential Waveform (Mathematical Function of Positive & Negative Channel) VID 0V VID p -n RSKM (Receiver input skew margin) Cyclone III Device Handbook Volume 2 HIGH-SPEED I/O Block: The total margin left after accounting for the sampling window and TCCS. RSKM = (TUI – SW – TCCS) / 2. July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Glossary 1–29 Table 1–39. Glossary (Part 3 of 5) Letter Term Definitions VCCIO VOH VIH (AC ) VIH(DC) VREF S Single-ended Voltage referenced I/O Standard VIL(DC) VIL(AC ) VOL VSS The JEDEC standard for SSTl and HSTL I/O standards defines both the AC and DC input signal values. The AC values indicate the voltage levels at which the receiver must meet its timing specifications. The DC values indicate the voltage levels at which the final logic state of the receiver is unambiguously defined. After the receiver input crosses the AC value, the receiver changes to the new logic state. The new logic state is then maintained as long as the input stays beyond the DC threshold. This approach is intended to provide predictable receiver timing in the presence of input waveform ringing. T July 2012 SW (Sampling Window) HIGH-SPEED I/O Block: The period of time during which the data must be valid to capture it correctly. The setup and hold times determine the ideal strobe position in the sampling window. tC High-speed receiver/transmitter input and output clock period. TCCS (Channelto-channel-skew) HIGH-SPEED I/O Block: The timing difference between the fastest and slowest output edges, including tCO variation and clock skew. The clock is included in the TCCS measurement. tcin Delay from clock pad to I/O input register. tCO Delay from clock pad to I/O output. tcout Delay from clock pad to I/O output register. tDUTY HIGH-SPEED I/O Block: Duty cycle on high-speed transmitter output clock. tFALL Signal High-to-low transition time (80–20%). tH Input register hold time. Timing Unit Interval (TUI) HIGH-SPEED I/O block: The timing budget allowed for skew, propagation delays, and data sampling window. (TUI = 1/(Receiver Input Clock Frequency Multiplication Factor) = tC/w). tINJITTER Period jitter on PLL clock input. tOUTJITTER_DEDCLK Period jitter on dedicated clock output driven by a PLL. tOUTJITTER_IO Period jitter on general purpose I/O driven by a PLL. tpllcin Delay from PLL inclk pad to I/O input register. tpllcout Delay from PLL inclk pad to I/O output register. Altera Corporation Cyclone III Device Handbook Volume 2 1–30 Chapter 1: Cyclone III Device Datasheet Glossary Table 1–39. Glossary (Part 4 of 5) Letter Term Definitions Transmitter Output Waveforms for the LVDS, mini-LVDS, PPDS and RSDS Differential I/O Standards Single-Ended Waveform Positive Channel (p) = VOH VOD Negative Channel (n) = VOL Vos Transmitter Output Waveform Ground Differential Waveform (Mathematical Function of Positive & Negative Channel) VOD 0V VOD p -n U tRISE Signal Low-to-high transition time (20–80%). tSU Input register setup time. — Cyclone III Device Handbook Volume 2 — July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Glossary 1–31 Table 1–39. Glossary (Part 5 of 5) Letter V Term Definitions VCM(DC) DC Common Mode Input Voltage. VDIF(AC) AC differential Input Voltage: The minimum AC input differential voltage required for switching. VDIF(DC) DC differential Input Voltage: The minimum DC input differential voltage required for switching. VICM Input Common Mode Voltage: The common mode of the differential signal at the receiver. VID Input differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the receiver. VIH Voltage Input High: The minimum positive voltage applied to the input which is accepted by the device as a logic high. VIH(AC) High-level AC input voltage. VIH(DC) High-level DC input voltage. VIL Voltage Input Low: The maximum positive voltage applied to the input which is accepted by the device as a logic low. VIL (AC) Low-level AC input voltage. VIL (DC) Low-level DC input voltage. VIN DC input voltage. VOCM Output Common Mode Voltage: The common mode of the differential signal at the transmitter. VOD Output differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the transmitter. VOD = VOH – VOL. VOH Voltage Output High: The maximum positive voltage from an output which the device considers is accepted as the minimum positive high level. VOL Voltage Output Low: The maximum positive voltage from an output which the device considers is accepted as the maximum positive low level. VOS Output offset voltage: VOS = (VOH + VOL) / 2. VOX (AC) AC differential Output cross point voltage: The voltage at which the differential output signals must cross. VREF Reference voltage for SSTL, HSTL I/O Standards. VREF (AC) AC input reference voltage for SSTL, HSTL I/O Standards. VREF(AC) = VREF(DC) + noise. The peak-to-peak AC noise on VREF should not exceed 2% of VREF(DC). VREF (DC) DC input reference voltage for SSTL, HSTL I/O Standards. VSWING (AC) AC differential Input Voltage: AC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VSWING (DC) DC differential Input Voltage: DC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VTT Termination voltage for SSTL, HSTL I/O Standards. VX (AC) AC differential Input cross point Voltage: The voltage at which the differential input signals must cross. W — — X — — Y — — Z — — July 2012 Altera Corporation Cyclone III Device Handbook Volume 2 1–32 Chapter 1: Cyclone III Device Datasheet Document Revision History Document Revision History Table 1–40 lists the revision history for this document. Table 1–40. Document Revision History (Part 1 of 3) Date Version Changes Updated minimum fHSCLK value to 5 MHz. July 2012 3.5 December 2011 3.4 January 2010 3.3 December 2009 3.2 Minor changes to the text. July 2009 3.1 Minor edit to the hyperlinks. June 2009 October 2008 July 2008 Cyclone III Device Handbook Volume 2 3.0 2.2 2.1 ■ Updated “Supply Current” on page 1–5 and “Periphery Performance” on page 1–17. ■ Updated Table 1–3, Table 1–4, Table 1–13, Table 1–16, Table 1–17, Table 1–20, and Table 1–25. ■ Removed Table 1-32 and Table 1-33. ■ Added Literature: External Memory Interfaces reference. ■ Changed chapter title from DC and Switching Characteristics to “Cyclone III Device Data Sheet” on page 1–1. ■ Updated (Note 1) to Table 1–23 on page 1–17. ■ Updated “External Memory Interface Specifications” on page 1–23. ■ Replaced Table 1–32 on page 1–23. ■ Replaced Table 1–33 on page 1–23. ■ Added Table 1–36 on page 1–26. ■ Updated “I/O Timing” on page 1–28. ■ Removed “Typical Design Performance” section. ■ Removed “I/O Timing” subsections. ■ Updated chapter to new template. ■ Updated Table 1–1, Table 1–3, and Table 1–18. ■ Added (Note 7) to Table 1–3. ■ Added the “OCT Calibration Timing Specification” section. ■ Updated “Glossary” section. ■ Updated Table 1–38. ■ Added BLVDS information (I/O standard) into Table 1–39, Table 1–40, Table 1–41, Table 1–42. ■ Updated Table 1–43, Table 1–46, Table 1–47, Table 1–48, Table 1–49, Table 1–50, Table 1–51, Table 1–52, Table 1–53, Table 1–54, Table 1–55, Table 1–56, Table 1–57, Table 1–58, Table 1–59, Table 1–60, Table 1–61, Table 1–62, Table 1–63, Table 1–68, Table 1–69, Table 1–74, Table 1–75, Table 1–80, Table 1–81, Table 1–86, Table 1–87, Table 1–92, Table 1–93, Table 1–94, Table 1–95, Table 1–96, Table 1–97, Table 1–98, and Table 1–99. July 2012 Altera Corporation Chapter 1: Cyclone III Device Datasheet Document Revision History 1–33 Table 1–40. Document Revision History (Part 2 of 3) Date May 2008 December 2007 October 2007 July 2007 June 2007 July 2012 Version 2.0 1.5 1.4 1.3 1.2 Altera Corporation Changes ■ Updated “Operating Conditions” section and included information on automotive device. ■ Updated Table 1–3, Table 1–6, and Table 1–7, and added automotive information. ■ Under “Pin Capacitance” section, updated Table 1–9 and Table 1–10. ■ Added new “Schmitt Trigger Input” section with Table 1–12. ■ Under “I/O Standard Specifications” section, updated Table 1–13, 1–12 and 1–12. ■ Under “Switching Characteristics” section, updated Table 1–19, 1–15, 1–16, 1–16, 1–17, 1–18, 1–19, 1–20, 1–21, 1–21, 1–23, 1–23, 1–23, 1–24, and 1–25. ■ Updated Figure 1–5 and 1–29. ■ Deleted previous Table 1-35 “DDIO Outputs Half-Period Jitter”. ■ Under “I/O Timing” section, updated Table 1–38, 1–29, 1–32, 1–33, 1–26, and 1–26. ■ Under “Typical Design Performance” section updated Table 1–46 through 1–145. ■ Under “Core Performance Specifications”, updated Tables 1-18 and 1-19. ■ Under “Preliminary, Correlated, and Final Timing”, updated Table 1-37. ■ Under “Typical Design Performance”, updated Tables 1-45, 1-46, 1-51, 1-52, 1-57, 1-58, Tables 1-63 through 1-68. 1-69, 1-70, 1-75, 1-76, 1-81, 1-82, Tables 1-87 through 1-92, Tables 1-99, 1-100, 1-107, and 1-108. ■ Updated the CVREFTB value in Table 1-9. ■ Updated Table 1-21. ■ Under “High-Speed I/O Specification” section, updated Tables 1-25 through 1-30. ■ Updated Tables 1-31 through 1-38. ■ Added new Table 1-32. ■ Under “Maximum Input and Output Clock Toggle Rate” section, updated Tables 1-40 through 1-42. ■ Under “IOE Programmable Delay” section, updated Tables 1-43 through 1-44. ■ Under “User I/O Pin Timing Parameters” section, updated Tables 1-45 through 1-92. ■ Under “Dedicated Clock Pin Timing Parameters” section, updated Tables 1-93 through 1108. ■ Updated Table 1-1 with VESDHBM and VESDCDM information. ■ Updated RCONF_PD information in Tables 1-10. ■ Added Note (3) to Table 1-12. ■ Updated tDLOCK information in Table 1-19. ■ Updated Table 1-43 and Table 1-44. ■ Added “Document Revision History” section. Updated Cyclone III graphic in cover page. Cyclone III Device Handbook Volume 2 1–34 Chapter 1: Cyclone III Device Datasheet Document Revision History Table 1–40. Document Revision History (Part 3 of 3) Date Version May 2007 March 2007 Cyclone III Device Handbook Volume 2 1.1 1.0 Changes ■ Corrected current unit in Tables 1-1, 1-12, and 1-14. ■ Added Note (3) to Table 1-3. ■ Updated Table 1-4 with ICCINT0, ICCA0, ICCD_PLL0, and ICCIO0 information. ■ Updated Table 1-9 and added Note (2). ■ Updated Table 1-19. ■ Updated Table 1-22 and added Note (1). ■ Changed I/O standard from 1.5-V LVTTL/LVCMOS and 1.2-V LVTTL/LVCMOS to 1.5-V LVCMOS and 1.2-V LVCMOS in Tables 1-41, 1-42, 1-43, 1-44, and 1-45. ■ Updated Table 1-43 with changes to LVPEC and LVDS and added Note (5). ■ Updated Tables 1-46, 1-47, Tables 1-54 through 1-95, and Tables 1-98 through 1-111. ■ Removed speed grade –6 from Tables 1-90 through 1-95, and from Tables 1-110 through 1-111. ■ Added a waveform (Receiver Input Waveform) in glossary under letter “R” (Table 1-112). Initial release. July 2012 Altera Corporation
EP3C40Q240C8N 价格&库存

很抱歉,暂时无法提供与“EP3C40Q240C8N”相匹配的价格&库存,您可以联系我们找货

免费人工找货