Am29LV128MH/L
Data Sheet
RETIRED PRODUCT
This product has been retired and is not recommended for designs. For new and current designs, S29GL256N supersedes Am29LV128MH/L and is the factory-recommended migration path. Please refer to the S29GL256N datasheet for specifications and ordering information. Availability of this document is retained for reference and historical purposes only.
The following document contains information on Spansion memory products.
Continuity of Specifications
There is no change to this data sheet as a result of offering the device as a Spansion product. Any changes that have been made are the result of normal data sheet improvement and are noted in the document revision summary.
For More Information
Please contact your local sales office for additional information about Spansion memory solutions.
Publication Number 25270 Revision C
Amendment 7 Issue Date January 31, 2007
THIS PAGE LEFT INTENTIONALLY BLANK.
DATA SHEET
Am29LV128MH/L
128 Megabit (8 M x 16-Bit/16 M x 8-Bit) MirrorBit™ 3.0 Volt-only Uniform Sector Flash Memory with VersatileI/O™ Control
This product has been retired and is not recommended for designs. For new and current designs, S29GL256N supersedes Am29LV128MH/L and is the factory-recommended migration path. Please refer to the S29GL256N datasheet for specifications and ordering information. Availability of this document is retained for reference and historical purposes only..
DISTINCTIVE CHARACTERISTICS
ARCHITECTURAL ADVANTAGES Single power supply operation — 3 volt read, erase, and program operations VersatileI/O™ control — Device generates data output voltages and tolerates data input voltages on the CE# and DQ inputs/outputs as determined by the voltage on the VIO pin; operates from 1.65 to 3.6 V Manufactured on 0.23 µm MirrorBit process technology Secured Silicon Sector region — 128-word/256-byte sector for permanent, secure identification through an 8-word/16-byte random Electronic Serial Number, accessible through a command sequence — May be programmed and locked at the factory or by the customer Flexible sector architecture — Two hundred fifty-six 32 Kword (64 Kbyte) sectors Compatibility with JEDEC standards — Provides pinout and software compatibility for single-power supply flash, and superior inadvertent write protection Minimum 100,000 erase cycle guarantee per sector 20-year data retention at 125°C PERFORMANCE CHARACTERISTICS High performance — 90 ns access time — 25 ns page read times — 0.5 s typical sector erase time — 15 s typical effective write buffer word programming time: 16-word/32-byte write buffer reduces overall programming time for multiple-word updates — 4-word/8-byte page read buffer — 16-word/32-byte write buffer Low power consumption (typical values at 3.0 V, 5 MHz) — 13 mA typical active read current — 50 mA typical erase/program current — 1 µA typical standby mode current Package options — 56-pin TSOP — 64-ball Fortified BGA SOFTWARE & HARDWARE FEATURES Software features — Program Suspend & Resume: read other sectors before programming operation is completed — Erase Suspend & Resume: read/program other sectors before an erase operation is completed — Data# polling & toggle bits provide status — Unlock Bypass Program command reduces overall multiple-word or byte programming time — CFI (Common Flash Interface) compliant: allows host system to identify and accommodate multiple flash devices Hardware features — Sector Group Protection: hardware-level method of preventing write operations within a sector group — Temporary Sector Group Unprotect: VID-level method of changing code in locked sector groups — WP#/ACC input accelerates programming time (when high voltage is applied) for greater throughput during system production. Protects first or last sector regardless of sector protection settings — Hardware reset input (RESET#) resets device — Ready/Busy# output (RY/BY#) detects program or erase cycle completion
This Data Sheet states AMD’s current specifications regarding the Products described herein. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications.
Publication# 25270 Rev: C Amendment: 7 Issue Date: January 31, 2007
DATA
SHEET
GENERAL DESCRIPTION
The Am29LV128MH/L is a 128 Mbit, 3.0 volt single power supply flash memory devices organized as 8,388,608 words or 16,777,216 bytes. The device has a 16-bit wide data bus that can also function as an 8-bit wide data bus by using the BYTE# input. The device can be programmed either in the host system or in standard EPROM programmers. An access time of 90, 100, 110, or 120 ns is available. Note that each access time has a specific operating voltage range (VCC) and an I/O voltage range (VIO), as specified in “Product Selector Guide” on page 6 and the “Ordering Information” on page 10. The device is offered in a 56-pin TSOP, 64-ball Fortified BGA. Each device has separate chip enable (CE#), write enable (WE#) and output enable (OE#) controls. Each device requires only a single 3.0 volt power supply for both read and write functions. In addition to a V CC i nput, a high-voltage a ccelerated program (WP#/ACC) input provides shorter programming times through increased current. This feature is intended to facilitate factory throughput during system production, but may also be used in the field if desired. The device is entirely command set compatible with the JEDEC single-power-supply Flash standard . Commands are written to the device using standard microprocessor write timing. Write cycles also internally latch addresses and data needed for the programming and erase operations. The sector erase architecture allows memory sectors to be erased and reprogrammed without affecting the data contents of other sectors. The device is fully erased when shipped from the factory. Device programming and erasure are initiated through command sequences. Once a program or erase operation has begun, the host system need only poll the DQ7 (Data# Polling) or DQ6 (toggle) status bits or monitor the Ready/Busy# (RY/BY#) output to determine whether the operation is complete. To facilitate programming, an Unlock Bypass mode reduces command sequence overhead by requiring only two write cycles to program data instead of four. The VersatileI/O™ (VIO) control allows the host system to set the voltage levels that the device generates and tolerates on the CE# control input and DQ I/Os to the same voltage level that is asserted on the VIO pin. Refer to the Ordering Information section for valid VIO options. Hardware data protection measures include a low VCC detector that automatically inhibits write operations during power transitions. The hardware sector group protection feature disables both program and erase operations in any combination of sector groups of memory. This can be achieved in-system or via programming equipment. The Erase Suspend/Erase Resume feature allows the host system to pause an erase operation in a given sector to read or program any other sector and then complete the erase operation. The P rogram Suspend/Program Resume feature enables the host system to pause a program operation in a given sector to read any other sector and then complete the program operation. The hardware RESET# pin terminates any operation in progress and resets the device, after which it is then ready for a new operation. The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the device, enabling the host system to read boot-up firmware from the Flash memory device. The device reduces power consumption in the standby mode when it detects specific voltage levels on CE# and RESET#, or when addresses have been stable for a specified period of time. The Secured Silicon Sector provides a 128-word/256-byte area for code or data that can be permanently protected. Once this sector is protected, no further changes within the sector can occur. The Write Protect (WP#/ACC ) feature protects the first or last sector by asserting a logic low on the WP# pin. AMD MirrorBit flash technology combines years of Flash memory manufacturing experience to produce the highest levels of quality, reliability and cost effectiveness. The device electrically erases all bits within a sector simultaneously via hot-hole assisted erase. The data is programmed using hot electron injection.
RELATED DOCUMENTS
For a comprehensive information on MirrorBit products, including migration information, data sheets, application notes, and software drivers, please see www.amd.com → Flash Memory → Product Information→MirrorBit→Flash Information→Technical Documentation. The following is a partial list of documents closely related to this product: MirrorBit™ Flash Memory Write Buffer Programming and Page Buffer Read Implementing a Common Layout for AMD MirrorBit and Intel StrataFlash Memory Devices Migrating from Single-byte to Three-byte Device IDs Am29LV256M, 256 Mbit MirrorBit Flash device (in 64-ball, 18 x 12 mm Fortified BGA package)
4
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
TABLE OF CONTENTS
Continuity of Specifications ............................................................. i For More Information ....................................................................... i Sector Erase Command Sequence .............................................. 34 Erase Suspend/Erase Resume Commands ................................ 35
Figure 7. Erase Operation.............................................................. 36
Product Selector Guide . . . . . . . . . . . . . . . . . . . . . 6 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . 7 Pin Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Ordering Information . . . . . . . . . . . . . . . . . . . . . . 10 Device Bus Operations . . . . . . . . . . . . . . . . . . . . 11
Table 1. Device Bus Operations ...........................................................11
Command Definitions ............................................................. 37
Table 10. Command Definitions (x16 Mode, BYTE# = VIH) ................. 37 Table 11. Command Definitions (x8 Mode, BYTE# = VIL) ................... 38
Write Operation Status . . . . . . . . . . . . . . . . . . . . . 39 DQ7: Data# Polling ...................................................................... 39
Figure 8. Data# Polling Algorithm .................................................. 39
Word/Byte Configuration ........................................................ 11 VersatileIO™ (VIO) Control ........................................................... 11 Requirements for Reading Array Data ......................................... 12 Page Mode Read .................................................................... 12 Writing Commands/Command Sequences .................................. 12 Write Buffer ............................................................................. 12 Accelerated Program Operation ............................................. 12 Autoselect Functions .............................................................. 12 Standby Mode ........................................................................ 12 Automatic Sleep Mode ................................................................. 13 RESET#: Hardware Reset Pin ..................................................... 13 Output Disable Mode ................................................................... 13
Table 2. Sector Address Table ..............................................................14
RY/BY#: Ready/Busy#............................................................ 40 DQ6: Toggle Bit I .......................................................................... 40
Figure 9. Toggle Bit Algorithm........................................................ 41
DQ2: Toggle Bit II ......................................................................... 41 Reading Toggle Bits DQ6/DQ2 .................................................... 41 DQ5: Exceeded Timing Limits ...................................................... 42 DQ3: Sector Erase Timer ............................................................. 42 DQ1: Write-to-Buffer Abort ........................................................... 42
Table 12. Write Operation Status ......................................................... 43
Absolute Maximum Ratings. . . . . . . . . . . . . . . . . 44
Figure 10. Maximum Negative Overshoot Waveform ................... 44 Figure 11. Maximum Positive Overshoot Waveform..................... 44
Autoselect Mode..................................................................... 20
Table 3. Autoselect Codes, (High Voltage Method) .............................20
Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . . 44 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 45 Test Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 12. Test Setup.................................................................... 46 Table 13. Test Specifications ......................................................... 46
Sector Group Protection and Unprotection .................................. 21
Table 4. Sector Group Protection/Unprotection Address Table .....21
Key to Switching Waveforms. . . . . . . . . . . . . . . . 46
Figure 13. Input Waveforms and Measurement Levels ................. 46
Write Protect (WP#)................................................................ 22 Temporary Sector Group Unprotect ............................................. 22
Figure 1. Temporary Sector Group Unprotect Operation................ 22 Figure 2. In-System Sector Group Protect/Unprotect Algorithms ... 23
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 47 Read-Only Operations ........................................................... 47
Figure 14. Read Operation Timings ............................................... 47 Figure 15. Page Read Timings ...................................................... 48
Secured Silicon Sector Flash Memory Region ............................. 24
Table 5. Secured Silicon Sector Contents ......................................24 Figure 3. Secured Silicon Sector Protect Verify .............................. 25
Hardware Reset (RESET#) .................................................... 49
Figure 16. Reset Timings ............................................................... 49
Hardware Data Protection ............................................................ 25
Erase and Program Operations .............................................. 50
Figure 17. Reset Timings ............................................................... Figure 18. Program Operation Timings.......................................... Figure 19. Accelerated Program Timing Diagram.......................... Figure 20. Chip/Sector Erase Operation Timings .......................... Figure 21. Data# Polling Timings (During Embedded Algorithms). Figure 22. Toggle Bit Timings (During Embedded Algorithms)...... Figure 23. DQ2 vs. DQ6................................................................. 51 52 52 53 54 55 55
Low VCC Write Inhibit ............................................................ 25 Write Pulse “Glitch” Protection ............................................... 25 Logical Inhibit .......................................................................... 25 Power-Up Write Inhibit ............................................................ 25 Common Flash Memory Interface (CFI) . . . . . . . 25 Table 6. CFI Query Identification String .............................. 26
Table 7. System Interface String......................................................26
Temporary Sector Group Unprotect ....................................... 56
Figure 24. Temporary Sector Group Unprotect Timing Diagram ... 56 Figure 25. Sector Group Protect and Unprotect Timing Diagram .. 57
Table 8. Device Geometry Definition................................... 27 Table 9. Primary Vendor-Specific Extended Query............. 28 Command Definitions . . . . . . . . . . . . . . . . . . . . . 29 Reading Array Data ...................................................................... 29 Reset Command .......................................................................... 29 Autoselect Command Sequence .................................................. 29 Enter Secured Silicon Sector/Exit Secured Silicon Sector Command Sequence ................................................................... 30 Word Program Command Sequence ........................................... 30 Unlock Bypass Command Sequence ..................................... 30 Write Buffer Programming ...................................................... 30 Accelerated Program .............................................................. 31
Figure 4. Write Buffer Programming Operation............................... 32 Figure 5. Program Operation .......................................................... 33
Alternate CE# Controlled Erase and Program Operations ..... 58
Figure 26. Alternate CE# Controlled Write (Erase/Program) Operation Timings.......................................................................... 59
Program Suspend/Program Resume Command Sequence ........ 33
Figure 6. Program Suspend/Program Resume............................... 34
Latchup Characteristics . . . . . . . . . . . . . . . . . . . . 59 Erase And Programming Performance. . . . . . . . 60 TSOP Pin and BGA Package Capacitance . . . . . 61 Data Retention. . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . 62 TS056/TSR056—56-Pin Standard/Reverse Thin Small Outline Package (TSOP) ..................................................................... 62 LAA064—64-Ball Fortified Ball Grid Array 13 x 11 mm Package .............................................................. 63 Revision Summary . . . . . . . . . . . . . . . . . . . . . . . . 64
Chip Erase Command Sequence ................................................. 34
January 31, 2007 25270C7
Am29LV128MH/L
5
DATA
SHEET
PRODUCT SELECTOR GUIDE
Part Number Regulated Voltage Range VCC = 3.0–3.6 V Full Voltage Range VCC = 2.7–3.6 V 103R 113R 93R VIO = 3.0–3.6 V VIO = 2.7–3.6 V VIO = 1.65–3.6 V 103 (Note 2) VIO = 2.7–3.6 V 113 (Note 2) VIO = 1.65–3.6 V 110 110 30 30 40 40 30 30 Am29LV128MH/L 123R VIO = 1.65–3.6 V 123 (Note 2) VIO = 1.65–3.6 V 120 120 40 40
Speed/ Voltage Option
Max. Access Time (ns) Max. CE# Access Time (ns) Max. Page access time (tPACC) Max. OE# Access Time (ns) Notes:
90 90 25 25
100 100 30 30
1.
See “AC Characteristics” for full specifications.
2.
Contact factory for availability and ordering information.
BLOCK DIAGRAM
RY/BY# VCC VSS Erase Voltage Generator RESET# WE# WP#/ACC BYTE# VIO Input/Output Buffers Sector Switches DQ0–DQ15 (A-1)
State Control Command Register
PGM Voltage Generator Chip Enable Output Enable Logic STB Data Latch
CE# OE#
STB VCC Detector Timer Address Latch
Y-Decoder
Y-Gating
X-Decoder
Cell Matrix
A22–A0
6
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
CONNECTION DIAGRAMS
NC A22 A15 A14 A13 A12 A11 A10 A9 A8 A19 A20 WE# RESET# A21 WP#/ACC RY/BY# A18 A17 A7 A6 A5 A4 A3 A2 A1 NC NC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 NC NC A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 NC VIO
56-Pin Standard TSOP
NC NC A16 BYTE# VSS DQ15/A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 OE# VSS CE# A0 NC VIO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
56-Pin Reverse TSOP
56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29
NC A22 A15 A14 A13 A12 A11 A10 A9 A8 A19 A20 WE# RESET# A21 WP#/ACC RY/BY# A18 A17 A7 A6 A5 A4 A3 A2 A1 NC NC
January 31, 2007 25270C7
Am29LV128MH/L
7
DATA
SHEET
CONNECTION DIAGRAMS
64- Ball Fortified BGA Top View, Balls Facing Down
A8 NC A7 A13 A6 A9 A5 WE# A4
B8 A22 B7 A12 B6 A8 B5 RESET# B4
C8 NC C7 A14 C6 A10 C5 A21 C4 A18 C3 A6 C2 A2 C1 NC
D8 VIO D7 A15 D6 A11 D5 A19 D4 A20 D3 A5 D2 A1 D1 NC
E8 VSS E7 A16 E6 DQ7 E5 DQ5 E4 DQ2 E3 DQ0 E2 A0 E1 NC
F8 NC F7
G8 NC G7
H8 NC H7 VSS H6 DQ6 H5 DQ4 H4 DQ3 H3 DQ1 H2 VSS H1 NC
BYTE# DQ15/A-1 F6 DQ14 F5 DQ12 F4 DQ10 F3 DQ8 F2 CE# F1 VIO G6 DQ13 G5 VCC G4 DQ11 G3 DQ9 G2 OE# G1 NC
RY/BY# WP#/ACC A3 A7 A2 A3 A1 NC B3 A17 B2 A4 B1 NC
Special Package Handling Instructions
Special handling is required for Flash Memory products in molded packages (TSOP and BGA). The package and/or data integrity may be compromised if the
package body is exposed to temperatures above 150°C for prolonged periods of time.
8
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
PIN DESCRIPTION
A22–A0 = 23 Address inputs DQ14–DQ0 = 15 Data inputs/outputs DQ15/A-1 CE# OE# WE# WP#/ACC RESET# BYTE# RY/BY# VCC = DQ15 (Data input/output, word mode), A-1 (LSB Address input, byte mode) = Chip Enable input = Output Enable input = Write Enable input = Hardware Write Protect input; Acceleration input = Hardware Reset Pin input = Selects 8-bit or 16-bit mode = Ready/Busy output = 3.0 volt-only single power supply (see Product Selector Guide for speed options and voltage supply tolerances) = Output Buffer power = Device Ground = Pin Not Connected Internally
LOGIC SYMBOL
23 A22–A0 CE# OE# WE# WP#/ACC RESET# VIO BYTE# RY/BY# DQ15–DQ0 (A-1) 16 or 8
VIO VSS NC
January 31, 2007 25270C7
Am29LV128MH/L
9
DATA
SHEET
ORDERING INFORMATION Standard Products
AMD standard products are available in several packages and operating ranges. The order number (Valid Combination) is formed by a combination of the following: Am29LV128MH/L H 123R PC I
TEMPERATURE RANGE F = Industrial (-40C to 85C) with Pb-free Package I = Industrial (–40°C to +85°C) PACKAGE TYPE E = 56-Pin Thin Small Outline Package (TSOP) Standard Pinout (TS 056) F = 56-Pin Thin Small Outline Package (TSOP) Reverse Pinout (TSR056) PC = 64-Ball Fortified Ball Grid Array (FBGA), 1.0 mm pitch, 13 x 11 mm package (LAA064) SPEED OPTION See Product Selector Guide and Valid Combinations SECTOR ARCHITECTURE AND SECTOR WRITE PROTECTION (WP# = VIL) H = Uniform sector device, highest address sector protected L = Uniform sector device, lowest address sector protected DEVICE NUMBER/DESCRIPTION Am29LV128MH/L 128 Megabit (8 M x 16-Bit/16 M x 8-Bit) MirrorBit Uniform Sector Flash Memory with VersatileIO™ Control, 3.0 Volt-only Read, Program, and Erase
Valid Combinations for TSOP Package Am29LV128MH93R Am29LV128ML93R Am29LV128MH103R Am29LV128ML103R Am29LV128MH113R Am29LV128ML113R Am29LV128MH123R Am29LV128ML123R EI, FI EF
Speed (ns) 90 100 110 120
VIO Range 3.0–3.6 V 2.7–3.6 V
VCC Range
Valid Combinations for Fortified BGA Package Order Number Am29LV128MH93R Am29LV128ML93R Package Marking L128MH93N L128ML93N L128MH103N PCI, L128ML103N PCF L128MH113N L128ML113N L128MH123N L128ML123N I, F
Speed VIO VCC (ns) Range Range 90 100 110 120 3.0– 3.6V 2.7– 3.6 V 1.65– 3.6 V 1.65– 3.6 V 3.0– 3.6 V
3.0–3.6 V 1.65–3.6 V 1.65–3.6 V
Am29LV128MH103R Am29LV128ML103R Am29LV128MH113R Am29LV128ML113R Am29LV128MH123R Am29LV128ML123R
Valid Combinations Valid Combinations list configurations planned to be supported in volume for this device. Consult the local AMD sales office to confirm availability of specific valid combinations and to check on newly released combinations.
Notes: 1. For 100, 110, and 120 speed option shown in product selector guide, contact AMD for availability and ordering information. 2. To select product with ESN factory-locked into the Secured Silicon Sector: 1) select order number from the valid combinations given above, 2) add designator “N” at the end of the order number, and 3) modify the speed option indicator as follows [103R = 10R, 113R = 11R, 123R = 12R, 93R, 103, 113, 123 = no change]. Example: Am29LV128MH12RPCIN. For Fortified BGA packages, modify the speed option indicator as follows: [103N = 10N, 113N = 11N, 123N = 12N, 93N = no change]. The designator “N” will also appear at the end of the package marking. Example: L128MH12NIN.
10
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
DEVICE BUS OPERATIONS
This section describes the requirements and use of the device bus operations, which are initiated through the internal command register. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The contents of the Table 1. register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. Table 1 lists the device bus operations, the inputs and control levels they require, and the resulting output. The following subsections describe each of these operations in further detail.
Device Bus Operations
DQ8–DQ15
Operation Read Write (Program/Erase) Accelerated Program Standby Output Disable Reset Sector Group Protect (Note 2) Sector Group Unprotect (Note 2) Temporary Sector Group Unprotect
CE# L L L VCC ± 0.3 V L X L
OE# L H H X H X H
WE# H L L X H X L
RESET# H H H VCC ± 0.3 V H L VID
WP#
ACC
Addresses (Note 2) AIN AIN AIN
DQ0– DQ7 DOUT
BYTE# = VIH DOUT
BYTE# = VIL DQ8–DQ14 = High-Z, DQ15 = A-1 High-Z High-Z High-Z X
X (Note 3) (Note 3) X X X H
L/H L/H VHH H L/H L/H L/H
(Note 4) (Note 4) (Note 4) (Note 4) High-Z High-Z High-Z (Note 4) High-Z High-Z High-Z X
X X X
SA, A6 =L, A3=L, A2=L, A1=H, A0=L SA, A6=H, A3=L, A2=L, A1=H, A0=L AIN
L
H
L
VID
H
L/H
(Note 4)
X
X
X
X
X
VID
H
L/H
(Note 4) (Note 4)
High-Z
Legend: L = Logic Low = VIL, H = Logic High = VIH, VID = 11.5–12.5 V, VHH = 11.5–12.5 V, X = Don’t Care, SA = Sector Address, AIN = Address In, DIN = Data In, DOUT = Data Out Notes: 1. Addresses are A22:A0 in word mode; A22:A-1 in byte mode. Sector addresses are A22:A15 in both modes. 2. The sector group protect and sector group unprotect functions may also be implemented via programming equipment. See the “Sector Group Protection and Unprotection” section. 3. If WP# = VIL, the first or last sector remains protected. If WP# = VIH, the first or last sector will be protected or unprotected as determined by the method described in “Write Protect (WP#)”. All sectors are unprotected when shipped from the factory (The Secured Silicon Sector may be factory protected depending on version ordered.) 4. DIN or DOUT as required by command sequence, data polling, or sector protect algorithm (see Figure 2).
Word/Byte Configuration
The BYTE# pin controls whether the device data I/O pins operate in the byte or word configuration. If the BYTE# pin is set at logic ‘1’, the device is in word configuration, DQ0–DQ15 are active and controlled by CE# and OE#. If the BYTE# pin is set at logic ‘0’, the device is in byte configuration, and only data I/O pins DQ0–DQ7 are active and controlled by CE# and OE#. The data I/O
pins DQ8–DQ14 are tri-stated, and the DQ15 pin is used as an input for the LSB (A-1) address function.
VersatileIO™ (VIO) Control
The VersatileIO™ (VIO) control allows the host system to set the voltage levels that the device generates and tolerates on CE# and DQ I/Os to the same voltage level that is asserted on VIO. See “Ordering Information” for VIO options on this device.
January 31, 2007 25270C7
Am29LV128MH/L
11
DATA
SHEET tails on programming data to the device using both standard and Unlock Bypass command sequences. An erase operation can erase one sector, multiple sectors, or the entire device. Table 2 indicates the address space that each sector occupies. See the table in “DC Characteristics” on page 45 for the active current specification for the write mode. “AC Characteristics” on page 47 contains timing specification tables and timing diagrams for write operations. Write Buffer Write Buffer Programming allows the system write to a maximum of 16 words/32 bytes in one programming operation. This results in faster effective programming time than the standard programming algorithms. See “Write Buffer” for more information. Accelerated Program Operation The device offers accelerated program operations through the ACC function. This is one of two functions provided by the WP#/ACC pin. This function is primarily intended to allow faster manufacturing throughput at the factory. If the system asserts VHH on this pin, the device automatically enters the aforementioned Unlock Bypass mode, temporarily unprotects any protected sector groups, and uses the higher voltage on the pin to reduce the time required for program operations. The system would use a two-cycle program command sequence as required by the Unlock Bypass mode. Removing VHH from the WP#/ACC pin returns the device to normal operation. Note that the WP#/ACC pin must not be at V HH for operations other than accelerated programming, or device damage may result. WP# has an internal pullup; when unconnected, WP# is at VIH. Autoselect Functions If the system writes the autoselect command sequence, the device enters the autoselect mode. The system can then read autoselect codes from the internal register (which is separate from the memory array) on DQ7–DQ0. Standard read cycle timings apply in this mode. See “Autoselect Mode” on page 20 and “Autoselect Command Sequence” on page 29 for more information.
Requirements for Reading Array Data
To read array data from the outputs, the system must drive the CE# and OE# pins to VIL. CE# is the power control and selects the device. OE# is the output control and gates array data to the output pins. WE# should remain at VIH. The internal state machine is set for reading array data upon device power-up, or after a hardware reset. This ensures that no spurious alteration of the memory content occurs during the power transition. No command is necessary in this mode to obtain array data. Standard microprocessor read cycles that assert valid addresses on the device address inputs produce valid data on the device data outputs. The device remains enabled for read access until the command register contents are altered. See “Reading Array Data” for more information. See the table, See “Read-Only Operations” on page 47 for timing specifications and Figure 14 for the timing diagram. See the table in “DC Characteristics” on page 45 for the active current specification on reading array data. Page Mode Read The device is capable of fast page mode read and is compatible with the page mode Mask ROM read operation. This mode provides faster read access speed for random locations within a page. The page size of the device is 4 words/8 bytes. The appropriate page is selected by the higher address bits A(max)–A2. Address bits A1–A0 in word mode (A1–A-1 in byte mode) determine the specific word within a page. This is an asynchronous operation; the microprocessor supplies the specific word location. The random or initial page access is equal to tACC or tCE and subsequent page read accesses (as long as the locations specified by the microprocessor falls within that page) is equivalent to tPACC. When CE# is deasserted and reasserted for a subsequent access, the access time is t ACC o r t CE . Fast page mode accesses are obtained by keeping the “read-page addresses” constant and changing the “intra-read page” addresses.
Writing Commands/Command Sequences
To write a command or command sequence (which includes programming data to the device and erasing sectors of memory), the system must drive WE# and CE# to VIL, and OE# to VIH. The device features an Unlock Bypass mode to facilitate faster programming. Once the device enters the Unlock Bypass mode, only two write cycles are required to program a word or byte, instead of four. The “Word Program Command Sequence” section has de-
Standby Mode
When the system is not reading or writing to the device, it can place the device in the standby mode. In this mode, current consumption is greatly reduced, and the outputs are placed in the high impedance state, independent of the OE# input. The device enters the CMOS standby mode when the CE# and RESET# pins are both held at VIO ± 0.3 V. (Note that this is a more restricted voltage range than
12
Am29LV128MH/L
25270C7 January 31, 2007
DATA VIH.) If CE# and RESET# are held at VIH, but not within VIO ± 0.3 V, the device will be in the standby mode, but the standby current will be greater. The device requires standard access time (t CE ) for read access when the device is in either of these standby modes, before it is ready to read data. If the device is deselected during erasure or programming, the device draws active current until the operation is completed. See the table in “DC Characteristics” on page 45 for the standby current specification.
SHEET SET# pin is driven low for at least a period of tRP, the device immediately terminates any operation in progress, tristates all output pins, and ignores all read/write commands for the duration of the RESET# pulse. The device also resets the internal state machine to reading array data. The operation that was interrupted should be reinitiated once the device is ready to accept another command sequence, to ensure data integrity. Current is reduced for the duration of the RESET# pulse. When RESET# is held at VSS±0.3 V, the device draws CMOS standby current (ICC4). If RESET# is held at VIL but not within VSS±0.3 V, the standby current will be greater. The RESET# pin may be tied to the system reset circuitry. A system reset would thus also reset the Flash memory, enabling the system to read the boot-up firmware from the Flash memory. See the tables in “AC Characteristics” on page 47 for RESET# parameters and to Figure 16 for the timing diagram.
Automatic Sleep Mode
The automatic sleep mode minimizes Flash device energy consumption. The device automatically enables this mode when addresses remain stable for t ACC + 30 ns. The automatic sleep mode is independent of the CE#, WE#, and OE# control signals. Standard address access timings provide new data when addresses are changed. While in sleep mode, output data is latched and always available to the system. See the table in “DC Characteristics” on page 45 for the automatic sleep mode current specification.
Output Disable Mode
When the OE# input is at VIH, output from the device is disabled. The output pins are placed in the high impedance state.
RESET#: Hardware Reset Pin
The RESET# pin provides a hardware method of resetting the device to reading array data. When the RE-
January 31, 2007 25270C7
Am29LV128MH/L
13
DATA Table 2.
SHEET
Sector Address Table (Sheet 1 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) 000000–00FFFF 010000–01FFFF 020000–02FFFF 030000–03FFFF 040000–04FFFF 050000–05FFFF 060000–06FFFF 070000–07FFFF 080000–08FFFF 090000–09FFFF 0A0000–0AFFFF 0B0000–0BFFFF 0C0000–0CFFFF 0D0000–0DFFFF 0E0000–0EFFFF 0F0000–0FFFFF 100000–10FFFF 110000–11FFFF 120000–12FFFF 130000–13FFFF 140000–14FFFF 150000–15FFFF 160000–16FFFF 170000–17FFFF 180000–18FFFF 190000–19FFFF 1A0000–1AFFFF 1B0000–1BFFFF 1C0000–1CFFFF 1D0000–1DFFFF 1E0000–1EFFFF 1F0000–1FFFFF 200000–20FFFF 210000–21FFFF 220000–22FFFF 230000–23FFFF 240000–24FFFF 250000–25FFFF 260000–26FFFF 270000–27FFFF 280000–28FFFF 290000–29FFFF 2A0000–2AFFFF 2B0000–2BFFFF 2C0000–2CFFFF 2D0000–2DFFFF 2E0000–2EFFFF 16-bit Address Range (in hexadecimal) 000000–007FFF 008000–00FFFF 010000–017FFF 018000–01FFFF 020000–027FFF 028000–02FFFF 030000–037FFF 038000–03FFFF 040000–047FFF 048000–04FFFF 050000–057FFF 058000–05FFFF 060000–067FFF 068000–06FFFF 070000–077FFF 078000–07FFFF 080000–087FFF 088000–08FFFF 090000–097FFF 098000–09FFFF 0A0000–0A7FFF 0A8000–0AFFFF 0B0000–0B7FFF 0B8000–0BFFFF 0C0000–0C7FFF 0C8000–0CFFFF 0D0000–0D7FFF 0D8000–0DFFFF 0E0000–0E7FFF 0E8000–0EFFFF 0F0000–0F7FFF 0F8000–0FFFFF 100000–107FFF 108000–10FFFF 110000–117FFF 118000–11FFFF 120000–127FFF 128000–12FFFF 130000–137FFF 138000–13FFFF 140000–147FFF 148000–14FFFF 150000–157FFF 158000–15FFFF 160000–167FFF 168000–16FFFF 170000–177FFF
Sector SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 SA18 SA19 SA20 SA21 SA22 SA23 SA24 SA25 SA26 SA27 SA28 SA29 SA30 SA31 SA32 SA33 SA34 SA35 SA36 SA37 SA38 SA39 SA40 SA41 SA42 SA43 SA44 SA45 SA46 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A22–A15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
14
Am29LV128MH/L
25270C7 January 31, 2007
DATA Table 2.
SHEET
Sector Address Table (Sheet 2 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) 2F0000–2FFFFF 300000–30FFFF 310000–31FFFF 320000–32FFFF 330000–33FFFF 340000–34FFFF 350000–35FFFF 360000–36FFFF 370000–37FFFF 380000–38FFFF 390000–39FFFF 3A0000–3AFFFF 3B0000–3BFFFF 3C0000–3CFFFF 3D0000–3DFFFF 3E0000–3EFFFF 3F0000–3FFFFF 400000–40FFFF 410000–41FFFF 420000–42FFFF 430000–43FFFF 440000–44FFFF 450000–45FFFF 460000–46FFFF 470000–47FFFF 480000–48FFFF 490000–49FFFF 4A0000–4AFFFF 4B0000–4BFFFF 4C0000–4CFFFF 4D0000–4DFFFF 4E0000–4EFFFF 4F0000–4FFFFF 500000–50FFFF 510000–51FFFF 520000–52FFFF 530000–53FFFF 540000–54FFFF 550000–55FFFF 560000–56FFFF 570000–57FFFF 580000–58FFFF 590000–59FFFF 5A0000–5AFFFF 5B0000–5BFFFF 5C0000–5CFFFF 5D0000–5DFFFF 5E0000–5EFFFF 16-bit Address Range (in hexadecimal) 178000–17FFFF 180000–187FFF 188000–18FFFF 190000–197FFF 198000–19FFFF 1A0000–1A7FFF 1A8000–1AFFFF 1B0000–1B7FFF 1B8000–1BFFFF 1C0000–1C7FFF 1C8000–1CFFFF 1D0000–1D7FFF 1D8000–1DFFFF 1E0000–1E7FFF 1E8000–1EFFFF 1F0000–1F7FFF 1F8000–1FFFFF 200000–207FFF 208000–20FFFF 210000–217FFF 218000–21FFFF 220000–227FFF 228000–22FFFF 230000–237FFF 238000–23FFFF 240000–247FFF 248000–24FFFF 250000–257FFF 258000–25FFFF 260000–267FFF 268000–26FFFF 270000–277FFF 278000–27FFFF 280000–287FFF 288000–28FFFF 290000–297FFF 298000–29FFFF 2A0000–2A7FFF 2A8000–2AFFFF 2B0000–2B7FFF 2B8000–2BFFFF 2C0000–2C7FFF 2C8000–2CFFFF 2D0000–2D7FFF 2D8000–2DFFFF 2E0000–2E7FFF 2E8000–2EFFFF 2F0000–2F7FFF
Sector SA47 SA48 SA49 SA50 SA51 SA52 SA53 SA54 SA55 SA56 SA57 SA58 SA59 SA60 SA61 SA62 SA63 SA64 SA65 SA66 SA67 SA68 SA69 SA70 SA71 SA72 SA73 SA74 SA75 SA76 SA77 SA78 SA79 SA80 SA81 SA82 SA83 SA84 SA85 SA86 SA87 SA88 SA89 SA90 SA91 SA92 SA93 SA94 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
A22–A15 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
January 31, 2007 25270C7
Am29LV128MH/L
15
DATA Table 2.
SHEET
Sector Address Table (Sheet 3 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) 5F0000–5FFFFF 600000–60FFFF 610000–61FFFF 620000–62FFFF 630000–63FFFF 640000–64FFFF 650000–65FFFF 660000–66FFFF 670000–67FFFF 680000–68FFFF 690000–69FFFF 6A0000–6AFFFF 6B0000–6BFFFF 6C0000–6CFFFF 6D0000–6DFFFF 6E0000–6EFFFF 6F0000–6FFFFF 700000–70FFFF 710000–71FFFF 720000–72FFFF 730000–73FFFF 740000–74FFFF 750000–75FFFF 760000–76FFFF 770000–77FFFF 780000–78FFFF 790000–79FFFF 7A0000–7AFFFF 7B0000–7BFFFF 7C0000–7CFFFF 7D0000–7DFFFF 7E0000–7EFFFF 7F0000–7FFFFF 800000–80FFFF 810000–81FFFF 820000–82FFFF 830000–83FFFF 840000–84FFFF 850000–85FFFF 860000–86FFFF 870000–87FFFF 880000–88FFFF 890000–89FFFF 8A0000–8AFFFF 8B0000–8BFFFF 8C0000–8CFFFF 8D0000–8DFFFF 8E0000–8EFFFF 16-bit Address Range (in hexadecimal) 2F8000–2FFFFF 300000–307FFF 308000–30FFFF 310000–317FFF 318000–31FFFF 320000–327FFF 328000–32FFFF 330000–337FFF 338000–33FFFF 340000–347FFF 348000–34FFFF 350000–357FFF 358000–35FFFF 360000–367FFF 368000–36FFFF 370000–377FFF 378000–37FFFF 380000–387FFF 388000–38FFFF 390000–397FFF 398000–39FFFF 3A0000–3A7FFF 3A8000–3AFFFF 3B0000–3B7FFF 3B8000–3BFFFF 3C0000–3C7FFF 3C8000–3CFFFF 3D0000–3D7FFF 3D8000–3DFFFF 3E0000–3E7FFF 3E8000–3EFFFF 3F0000–3F7FFF 3F8000–3FFFFF 400000–407FFF 408000–40FFFF 410000–417FFF 418000–41FFFF 420000–427FFF 428000–42FFFF 430000–437FFF 438000–43FFFF 440000–447FFF 448000–44FFFF 450000–457FFF 458000–45FFFF 460000–467FFF 468000–46FFFF 470000–477FFF
Sector SA95 SA96 SA97 SA98 SA99 SA100 SA101 SA102 SA103 SA104 SA105 SA106 SA107 SA108 SA109 SA110 SA111 SA112 SA113 SA114 SA115 SA116 SA117 SA118 SA119 SA120 SA121 SA122 SA123 SA124 SA125 SA126 SA127 SA128 SA129 SA130 SA131 SA132 SA133 SA134 SA135 SA136 SA137 SA138 SA139 SA140 SA141 SA142 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
A22–A15 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
16
Am29LV128MH/L
25270C7 January 31, 2007
DATA Table 2.
SHEET
Sector Address Table (Sheet 4 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) 8F0000–8FFFFF 900000–90FFFF 910000–91FFFF 920000–92FFFF 930000–93FFFF 940000–94FFFF 950000–95FFFF 960000–96FFFF 970000–97FFFF 980000–98FFFF 990000–99FFFF 9A0000–9AFFFF 9B0000–9BFFFF 9C0000–9CFFFF 9D0000–9DFFFF 9E0000–9EFFFF 9F0000–9FFFFF A00000–A0FFFF A10000–A1FFFF A20000–A2FFFF A30000–A3FFFF A40000–A4FFFF A50000–A5FFFF A60000–A6FFFF A70000–A7FFFF A80000–A8FFFF A90000–A9FFFF AA0000–AAFFFF AB0000–ABFFFF AC0000–ACFFFF AD0000–ADFFFF AE0000–AEFFFF AF0000–AFFFFF B00000–B0FFFF B10000–B1FFFF B20000–B2FFFF B30000–B3FFFF B40000–B4FFFF B50000–B5FFFF B60000–B6FFFF B70000–B7FFFF B80000–B8FFFF B90000–B9FFFF BA0000–BAFFFF BB0000–BBFFFF BC0000–BCFFFF BD0000–BDFFFF BE0000–BEFFFF 16-bit Address Range (in hexadecimal) 478000–47FFFF 480000–487FFF 488000–48FFFF 490000–497FFF 498000–49FFFF 4A0000–4A7FFF 4A8000–4AFFFF 4B0000–4B7FFF 4B8000–4BFFFF 4C0000–4C7FFF 4C8000–4CFFFF 4D0000–4D7FFF 4D8000–4DFFFF 4E0000–4E7FFF 4E8000–4EFFFF 4F0000–4F7FFF 4F8000–4FFFFF 500000–507FFF 508000–50FFFF 510000–517FFF 518000–51FFFF 520000–527FFF 528000–52FFFF 530000–537FFF 538000–53FFFF 540000–547FFF 548000–54FFFF 550000–557FFF 558000–55FFFF 560000–567FFF 568000–56FFFF 570000–577FFF 578000–57FFFF 580000–587FFF 588000–58FFFF 590000–597FFF 598000–59FFFF 5A0000–5A7FFF 5A8000–5AFFFF 5B0000–5B7FFF 5B8000–5BFFFF 5C0000–5C7FFF 5C8000–5CFFFF 5D0000–5D7FFF 5D8000–5DFFFF 5E0000–5E7FFF 5E8000–5EFFFF 5F0000–5F7FFF
Sector SA143 SA144 SA145 SA146 SA147 SA148 SA149 SA150 SA151 SA152 SA153 SA154 SA155 SA156 SA157 SA158 SA159 SA160 SA161 SA162 SA163 SA164 SA165 SA166 SA167 SA168 SA169 SA170 SA171 SA172 SA173 SA174 SA175 SA176 SA177 SA178 SA179 SA180 SA181 SA182 SA183 SA184 SA185 SA186 SA187 SA188 SA189 SA190 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A22–A15 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
January 31, 2007 25270C7
Am29LV128MH/L
17
DATA Table 2.
SHEET
Sector Address Table (Sheet 5 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) BF0000–BFFFFF C00000–C0FFFF C10000–C1FFFF C20000–C2FFFF C30000–C3FFFF C40000–C4FFFF C50000–C5FFFF C60000–C6FFFF C70000–C7FFFF C80000–C8FFFF C90000–C9FFFF CA0000–CAFFFF CB0000–CBFFFF CC0000–CCFFFF CD0000–CDFFFF CE0000–CEFFFF CF0000–CFFFFF D00000–D0FFFF D10000–D1FFFF D20000–D2FFFF D30000–D3FFFF D40000–D4FFFF D50000–D5FFFF D60000–D6FFFF D70000–D7FFFF D80000–D8FFFF D90000–D9FFFF DA0000–DAFFFF DB0000–DBFFFF DC0000–DCFFFF DD0000–DDFFFF DE0000–DEFFFF DF0000–DFFFFF E00000–E0FFFF E10000–E1FFFF E20000–E2FFFF E30000–E3FFFF E40000–E4FFFF E50000–E5FFFF E60000–E6FFFF E70000–E7FFFF E80000–E8FFFF E90000–E9FFFF EA0000–EAFFFF EB0000–EBFFFF EC0000–ECFFFF ED0000–EDFFFF EE0000–EEFFFF 16-bit Address Range (in hexadecimal) 5F8000–5FFFFF 600000–607FFF 608000–60FFFF 610000–617FFF 618000–61FFFF 620000–627FFF 628000–62FFFF 630000–637FFF 638000–63FFFF 640000–647FFF 648000–64FFFF 650000–657FFF 658000–65FFFF 660000–667FFF 668000–66FFFF 670000–677FFF 678000–67FFFF 680000–687FFF 688000–68FFFF 690000–697FFF 698000–69FFFF 6A0000–6A7FFF 6A8000–6AFFFF 6B0000–6B7FFF 6B8000–6BFFFF 6C0000–6C7FFF 6C8000–6CFFFF 6D0000–6D7FFF 6D8000–6DFFFF 6E0000–6E7FFF 6E8000–6EFFFF 6F0000–6F7FFF 6F8000–6FFFFF 700000–707FFF 708000–70FFFF 710000–717FFF 718000–71FFFF 720000–727FFF 728000–72FFFF 730000–737FFF 738000–73FFFF 740000–747FFF 748000–74FFFF 750000–757FFF 758000–75FFFF 760000–767FFF 768000–76FFFF 770000–777FFF
Sector SA191 SA192 SA193 SA194 SA195 SA196 SA197 SA198 SA199 SA200 SA201 SA202 SA203 SA204 SA205 SA206 SA207 SA208 SA209 SA210 SA211 SA212 SA213 SA214 SA215 SA216 SA217 SA218 SA219 SA220 SA221 SA222 SA223 SA224 SA225 SA226 SA227 SA228 SA229 SA230 SA231 SA232 SA233 SA234 SA235 SA236 SA237 SA238 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A22–A15 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
18
Am29LV128MH/L
25270C7 January 31, 2007
DATA Table 2.
SHEET
Sector Address Table (Sheet 6 of 6)
Sector Size (Kbytes/Kwords) 8-bit Address Range (in hexadecimal) EF0000–EFFFFF F00000–F0FFFF F10000–F1FFFF F20000–F2FFFF F30000–F3FFFF F40000–F4FFFF F50000–F5FFFF F60000–F6FFFF F70000–F7FFFF F80000–F8FFFF F90000–F9FFFF FA0000–FAFFFF FB0000–FBFFFF FC0000–FCFFFF FD0000–FDFFFF FE0000–FEFFFF FF0000–FFFFFF 16-bit Address Range (in hexadecimal) 778000–77FFFF 780000–787FFF 788000–78FFFF 790000–797FFF 798000–79FFFF 7A0000–7A7FFF 7A8000–7AFFFF 7B0000–7B7FFF 7B8000–7BFFFF 7C0000–7C7FFF 7C8000–7CFFFF 7D0000–7D7FFF 7D8000–7DFFFF 7E0000–7E7FFF 7E8000–7EFFFF 7F0000–7F7FFF 7F8000–7FFFFF
Sector SA239 SA240 SA241 SA242 SA243 SA244 SA245 SA246 SA247 SA248 SA249 SA250 SA251 SA252 SA253 SA254 SA255 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
A22–A15 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32 64/32
January 31, 2007 25270C7
Am29LV128MH/L
19
DATA
SHEET address must appear on the appropriate highest order address bits (see Table 2). Table 3 shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ7–DQ0. To access the autoselect codes in-system, the host system can issue the autoselect command via the command register, as shown in Table 10 and Table 11. This method does not require V ID. See “Autoselect Command Sequence” on page 29 for more information.
Autoselect Mode
The autoselect mode provides manufacturer and device identification, and sector group protection verification, through identifier codes output on DQ7–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires VID on address pin A9. Address pins A6, A3, A2, A1, and A0 must be as shown in Table 3 In addition, when verifying sector protection, the sector
Table 3.
Description CE# OE# WE#
Autoselect Codes, (High Voltage Method)
A9 A8 to A7 X A6 A5 to A4 X A3 to A2 L L
A22 A14 to to A15 A10 X X
DQ8 to DQ15
A1 A0
BYTE# BYTE# = VIH = VIL
00 22 22 22 X X X X X X
DQ7 to DQ0
Manufacturer ID: AMD Device ID Cycle 1 Cycle 2 Cycle 3
L
L
H
VID
L
L L H H H
L H L H L
01h 7Eh 12h 00h 01h (protected), 00h (unprotected) 98h (factory locked), 18h (not factory locked)
L
L
H
X
X
VID
X
L
X
H H
Sector Group Protection Verification Secured Silicon Sector Indicator Bit (DQ7), WP# protects highest address sector Secured Silicon Sector Indicator Bit (DQ7), WP# protects lowest address sector
L
L
H
SA
X
VID
X
L
X
L
L
L
H
X
X
VID
X
L
X
L
H
H
X
X
L
L
H
X
X
VID
X
L
X
L
H
H
X
X
88h (factory locked), 08h (not factory locked)
Legend: L = Logic Low = VIL, H = Logic High = VIH, SA = Sector Address, X = Don’t care.
20
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
Sector Group SA84–SA87 SA88–SA91 SA92–SA95 SA96–SA99 SA100–SA103 SA104–SA107 SA108–SA111 SA112–SA115 SA116–SA119 SA120–SA123 SA124–SA127 SA128–SA131 SA132–SA135 SA136–SA139 A22–A15 010101xx 010110xx 010111xx 011000xx 011001xx 011010xx 011011xx 011100xx 011101xx 011110xx 011111xx 100000xx 100001xx 100010xx 100011xx 100100xx 100101xx 100110xx 100111xx 101000xx 101001xx 101010xx 101011xx 101100xx 101101xx 101110xx 101111xx 110000xx 110001xx 110010xx 110011xx 110100xx 110101xx 110110xx 110111xx 111000xx 111001xx 111010xx 111011xx 111100xx 111101xx 111110xx 11111100 11111101 11111110 11111111
Sector Group Protection and Unprotection
The hardware sector group protection feature disables both program and erase operations in any sector group. The hardware sector group unprotection feature re-enables both program and erase operations in previously protected sector groups. Sector group protection/unprotection can be implemented via two methods. Sector group protection/unprotection requires VID on the RESET# pin only, and can be implemented either in-system or via programming equipment. Figure 2 shows the algorithms and Figure 25 shows the timing diagram. This method uses standard microprocessor bus cycle timing. For sector group unprotect, all unprotected sector group must first be protected prior to the first sector group unprotect write cycle. The device is shipped with all sector groups unprotected. AMD offers the option of programming and protecting sector groups at its factory prior to shipping the device through AMD’s ExpressFlash™ Service. Contact an AMD representative for details. It is possible to determine whether a sector group is protected or unprotected. See “Autoselect Mode” on page 20 for details. Table 4. Sector Group Protection/Unprotection Address Table
A22–A15 00000000 00000001 00000010 00000011 000001xx 000010xx 000011xx 000100xx 000101xx 000110xx 000111xx 001000xx 001001xx 001010xx 001011xx 001100xx 001101xx 001110xx 001111xx 010000xx 010001xx 010010xx 010011xx 010100xx SA0 SA1 SA2 SA3 SA4–SA7 SA8–SA11 SA12–SA15 SA16–SA19 SA20–SA23 SA24–SA27 SA28–SA31 SA32–SA35 SA36–SA39 SA40–SA43 SA44–SA47 SA48–SA51 SA52–SA55 SA56–SA59 SA60–SA63 SA64–SA67 SA68–SA71 SA72–SA75 SA76–SA79 SA80–SA83
SA140–SA143 SA144–SA147 SA148–SA151 SA152–SA155 SA156–SA159 SA160–SA163 SA164–SA167 SA168–SA171 SA172–SA175 SA176–SA179 SA180–SA183 SA184–SA187 SA188–SA191 SA192–SA195 SA196–SA199 SA200–SA203 SA204–SA207 SA208–SA211 SA212–SA215 SA216–SA219 SA220–SA223 SA224–SA227 SA228–SA231 SA232–SA235 SA236–SA239 SA240–SA243 SA244–SA247 SA248–SA251 SA252 SA253 SA254 SA255
Sector Group
January 31, 2007 25270C7
Am29LV128MH/L
21
DATA
SHEET shows the algorithm, and Figure 24 shows the timing diagrams, for this feature.
Write Protect (WP#)
The Write Protect function provides a hardware method of protecting the first or last sector group without using VID. Write Protect is one of two functions provided by the WP#/ACC input. If the system asserts VIL on the WP#/ACC pin, the device disables program and erase functions in the first or last sector group independently of whether those sector groups were protected or unprotected using the method described in “Sector Group Protection and Unprotection”. Note that if WP#/ACC is at VIL when the device is in the standby mode, the maximum input load current is increased. See the table in “DC Characteristics” on page 45 If the system asserts VIH on the WP#/ACC pin, the device reverts to whether the first or last sector was previously set to be protected or unprotected using the method described in “Sector Group Protection and Unprotection”. Note that WP# has an internal pullup; when unconnected, WP# is at VIH.
START
RESET# = VID (Note 1) Perform Erase or Program Operations
RESET# = VIH
Temporary Sector Group Unprotect Completed (Note 2)
Temporary Sector Group Unprotect
This feature allows temporary unprotection of previously protected sector groups to change data in-system. The Sector Group Unprotect mode is activated by setting the RESET# pin to VID. During this mode, formerly protected sector groups can be programmed or erased by selecting the sector group addresses. Once VID is removed from the RESET# pin, all the previously protected sector groups are protected again. Figure 1
Notes: 1. All protected sector groups unprotected (If WP# = VIL, the first or last sector will remain protected). 2. All previously protected sector groups are protected once again.
Figure 1. Temporary Sector Group Unprotect Operation
22
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
START Protect all sectors: The indicated portion of the sector protect algorithm must be performed for all unprotected sectors prior to issuing the first sector unprotect address PLSCNT = 1 RESET# = VID Wait 1 μs
START PLSCNT = 1 RESET# = VID Wait 1 μs
Temporary Sector Unprotect Mode
No
First Write Cycle = 60h? Yes Set up sector address Sector Protect: Write 60h to sector address with A6 = 0, A1 = 1, A0 = 0 Wait 150 µs Verify Sector Protect: Write 40h to sector address with A6 = 0, A1 = 1, A0 = 0 Read from sector address with A6 = 0, A1 = 1, A0 = 0 No
No First Write Cycle = 60h? Yes All sectors protected? Yes Set up first sector address Sector Unprotect: Write 60h to sector address with A6 = 1, A1 = 1, A0 = 0
Temporary Sector Unprotect Mode
Increment PLSCNT
Reset PLSCNT = 1
Wait 15 ms Verify Sector Unprotect: Write 40h to sector address with A6 = 1, A1 = 1, A0 = 0
No No PLSCNT = 25? Yes Data = 01h?
Increment PLSCNT
Yes
No Yes No
Read from sector address with A6 = 1, A1 = 1, A0 = 0 Set up next sector address
Device failed
Protect another sector? No Remove VID from RESET#
PLSCNT = 1000? Yes
Data = 00h? Yes
Device failed Write reset command
Last sector verified? Yes
No
Sector Group Protect Algorithm
Sector Protect complete
Sector Group Unprotect Algorithm
Remove VID from RESET#
Write reset command Sector Unprotect complete
Figure 2.
In-System Sector Group Protect/Unprotect Algorithms
January 31, 2007 25270C7
Am29LV128MH/L
23
DATA
SHEET the device. On power-up, or following a hardware reset, the device reverts to sending commands to sector SA0. Customer Lockable: Secured Silicon Sector NOT Programmed or Protected At the Factory Unless otherwise specified, the device is shipped such that the customer may program and protect the 256-byte Secured Silicon sector. Programming and protecting the Secured Silicon Sector must be used with caution since, once protected, there is no procedure available for unprotecting the Secured Silicon Sector area and none of the bits in the Secured Silicon Sector memory space can be modified in any way. The Secured Silicon Sector area can be protected using one of the following procedures: Write the three-cycle Enter Secured Silicon Sector Region command sequence, and then follow the in-system sector protect algorithm as shown in Figure 2, except that RESET# may be at either VIH or VID. This allows in-system protection of the Secured Silicon Sector without raising any device pin to a high voltage. Note that this method is only applicable to the Secured Silicon Sector. To verify the protect/unprotect status of the Secured Silicon Sector, follow the algorithm shown in Figure 3. Once the Secured Silicon Sector is programmed, locked and verified, the system must write the Exit Secured Silicon Sector Region command sequence to return to reading and writing within the remainder of the array. Factory Locked: Secured Silicon Sector Programmed and Protected At the Factory In devices with an ESN, the Secured Silicon Sector is protected when the device is shipped from the factory. The Secured Silicon Sector cannot be modified in any way. An ESN Factory Locked device has an 16-byte random ESN at addresses 000000h–000007h. Please contact your local AMD sales representative for details on ordering ESN Factory Locked devices. Customers may opt to have their code programmed by AMD through the AMD ExpressFlash service (Express Flash Factory Locked). The devices are then shipped from AMD’s factory with the Secured Silicon Sector permanently locked. Contact an AMD representative for details on using AMD’s ExpressFlash service.
Secured Silicon Sector Flash Memory Region
The Secured Silicon Sector feature provides a Flash memory region that enables permanent part identification through an Electronic Serial Number (ESN). The Secured Silicon Sector is 256 bytes in length, and uses a Secured Silicon Sector Indicator Bit (DQ7) to indicate whether or not the Secured Silicon Sector is locked when shipped from the factory. This bit is permanently set at the factory and cannot be changed, which prevents cloning of a factory locked part. This ensures the security of the ESN once the product is shipped to the field. AMD offers the device with the Secured Silicon Sector either customer lockable (standard shipping option) or factory locked (contact an AMD sales representative for ordering information). The customer-lockable version is shipped with the Secured Silicon Sector unprotected, allowing customers to program the sector after receiving the device. The customer-lockable version also has the Secured Silicon Sector Indicator Bit permanently set to a “0.” The factory-locked version is always protected when shipped from the factory, and has the Secured Silicon Sector Indicator Bit permanently set to a “1.” Thus, the Secured Silicon Sector Indicator Bit prevents customer-lockable devices from being used to replace devices that are factory locked. Note that the ACC function and unlock bypass modes are not available when the Secured Silicon Sector is enabled. The Secured Silicon sector address space in this device is allocated as follows: Table 5. Secured Silicon Sector Contents
Secured Silicon Sector Address Range 000000h–000007h 000008h–00007Fh Customer Lockable ESN Factory Locked ESN Unavailable ExpressFlash Factory Locked ESN or determined by customer Determined by customer
Determined by customer
The system accesses the Secured Silicon Sector through a command sequence (see “Enter Secured Silicon Sector/Exit Secured Silicon Sector Command Sequence” on page 30). After the system has written the Enter Secured Silicon Sector command sequence, it may read the Secured Silicon Sector by using the addresses normally occupied by the first sector (SA0). This mode of operation continues until the system issues the Exit Secured Silicon Sector command sequence, or until power is removed from
24
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET otherwise be caused by spurious system level signals during VCC power-up and power-down transitions, or from system noise.
START RESET# = VIH or VID Wait 1 μs Write 60h to any address If data = 00h, SecSi Sector is unprotected. If data = 01h, SecSi Sector is protected.
Low VCC Write Inhibit When VCC is less than VLKO, the device does not accept any write cycles. This protects data during VCC power-up and power-down. The command register and all internal program/erase circuits are disabled, and the device resets to the read mode. Subsequent writes are ignored until VCC is greater than VLKO. The system must provide the proper signals to the control pins to prevent unintentional writes when V CC i s greater than VLKO. Write Pulse “Glitch” Protection
Remove VIH or VID from RESET#
Write 40h to SecSi Sector address with A6 = 0, A1 = 1, A0 = 0 Read from SecSi Sector address with A6 = 0, A1 = 1, A0 = 0
Write reset command SecSi Sector Protect Verify complete
Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle. Logical Inhibit Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH or WE# = VIH. To initiate a write cycle, CE# and WE# must be a logical zero while OE# is a logical one. Power-Up Write Inhibit If WE# = CE# = VIL and OE# = VIH during power up, the device does not accept commands on the rising edge of WE#. The internal state machine is automatically reset to the read mode on power-up.
Figure 3.
Secured Silicon Sector Protect Verify
Hardware Data Protection
The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadver tent writes (refer to Table 10 and Table 11 for command definitions). In addition, the following hardware data protection measures prevent accidental erasure or programming, which might
COMMON FLASH MEMORY INTERFACE (CFI)
The Common Flash Interface (CFI) specification outlines device and host system software interrogation handshake, which allows specific vendor-specified software algorithms to be used for entire families of devices. Software support can then be device-independent, JEDEC ID-independent, and forward- and backward-compatible for the specified flash device families. Flash vendors can standardize their existing interfaces for long-term compatibility. This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address 55h, any time the device is ready to read array data. The system can read CFI information at the addresses given in Table 6, Table 7, Table 8, and Table 9. To terminate reading CFI data, the system must write the reset command. The system can also write the CFI query command when the device is in the autoselect mode. The device enters the CFI query mode, and the system can read CFI data at the addresses given in Table 6, Table 7, Table 8, and Table 9. The system must write the reset command to return the device to reading array data. For further information, please refer to the CFI Specification and CFI Publication 100, available via the World Wide Web at http://www.amd.com/flash/cfi. Alternatively, contact an AMD representative for copies of these documents.
January 31, 2007 25270C7
Am29LV128MH/L
25
DATA Table 6.
Addresses (x16) 10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 1Ah Data 0051h 0052h 0059h 0002h 0000h 0040h 0000h 0000h 0000h 0000h 0000h
SHEET
CFI Query Identification String
Description
Query Unique ASCII string “QRY”
Primary OEM Command Set Address for Primary Extended Table Alternate OEM Command Set (00h = none exists) Address for Alternate OEM Extended Table (00h = none exists)
Table 7.
Addresses (x16) 1Bh 1Ch 1Dh 1Eh 1Fh 20h 21h 22h 23h 24h 25h 26h Data 0027h 0036h 0000h 0000h 0007h 0007h 000Ah 0000h 0001h 0005h 0004h 0000h
System Interface String
Description
VCC Min. (write/erase) D7–D4: volt, D3–D0: 100 millivolt VCC Max. (write/erase) D7–D4: volt, D3–D0: 100 millivolt VPP Min. voltage (00h = no VPP pin present) VPP Max. voltage (00h = no VPP pin present) Typical timeout per single byte/word write 2N µs Typical timeout for Min. size buffer write 2N µs (00h = not supported) Typical timeout per individual block erase 2N ms Typical timeout for full chip erase 2N ms (00h = not supported) Max. timeout for byte/word write 2N times typical Max. timeout for buffer write 2N times typical Max. timeout per individual block erase 2N times typical Max. timeout for full chip erase 2N times typical (00h = not supported)
26
Am29LV128MH/L
25270C7 January 31, 2007
DATA Table 8.
Addresses (x16) 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch Data 0018h 0002h 0000h 0005h 0000h 0001h 00FFh 0000h 0000h 0001h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h
SHEET
Device Geometry Definition
Description
Device Size = 2 byte Flash Device Interface description (refer to CFI publication 100) Max. number of byte in multi-byte write = 2N (00h = not supported) Number of Erase Block Regions within device (01h = uniform device, 02h = boot device) Erase Block Region 1 Information (refer to the CFI specification or CFI publication 100)
N
Erase Block Region 2 Information (refer to CFI publication 100)
Erase Block Region 3 Information (refer to CFI publication 100)
Erase Block Region 4 Information (refer to CFI publication 100)
January 31, 2007 25270C7
Am29LV128MH/L
27
DATA Table 9.
Addresses (x16) 40h 41h 42h 43h 44h 45h Data 0050h 0052h 0049h 0031h 0033h 0008h
SHEET
Primary Vendor-Specific Extended Query
Description Query-unique ASCII string “PRI” Major version number, ASCII Minor version number, ASCII Address Sensitive Unlock (Bits 1-0) 0 = Required, 1 = Not Required Process Technology (Bits 7-2) 0010b = 0.23 µm MirrorBit
46h 47h 48h 49h 4Ah 4Bh 4Ch 4Dh
0002h 0001h 0001h 0004h 0000h 0000h 0001h 00B5h
Erase Suspend 0 = Not Supported, 1 = To Read Only, 2 = To Read & Write Sector Protect 0 = Not Supported, X = Number of sectors in per group Sector Temporary Unprotect 00 = Not Supported, 01 = Supported Sector Protect/Unprotect scheme 04 = 29LV800 mode Simultaneous Operation 00 = Not Supported, X = Number of Sectors in Bank Burst Mode Type 00 = Not Supported, 01 = Supported Page Mode Type 00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page ACC (Acceleration) Supply Minimum 00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV ACC (Acceleration) Supply Maximum 00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV Top/Bottom Boot Sector Flag
4Eh
00C5h
4Fh
0004h/ 0005h
00h = Uniform Device without WP# protect, 02h = Bottom Boot Device, 03h = Top Boot Device, 04h = Uniform sectors bottom WP# protect, 05h = Uniform sectors top WP# protect Program Suspend 00h = Not Supported, 01h = Supported
50h
0001h
28
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
COMMAND DEFINITIONS
Writing specific address and data commands or sequences into the command register initiates device operations. Table 10 and Table 11 defines the valid register command sequences. Writing incorrect address and data values or writing them in the improper sequence may place the device in an unknown state. A reset command is then required to return the device to reading array data. All addresses are latched on the falling edge of WE# or CE#, whichever happens later. All data is latched on the rising edge of WE# or CE#, whichever happens first. See “AC Characteristics” on page 47 for timing diagrams. written while the device is in the Erase Suspend mode, writing the reset command returns the device to the erase-suspend-read mode. Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to the read mode. If the device entered the autoselect mode while in the Erase Suspend mode, writing the reset command returns the device to the erase-suspend-read mode. If DQ5 goes high during a program or erase operation, writing the reset command returns the device to the read mode (or erase-suspend-read mode if the device was in Erase Suspend). Note that if DQ1 goes high during a Write Buffer Programming operation, the system must write the Write-to-Buffer-Abort Reset command sequence to reset the device for the next operation.
Reading Array Data
The device is “automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is ready to read array data after completing an Embedded Program or Embedded Erase algorithm. After the device accepts an Erase Suspend command, the device enters the erase-suspend-read mode, after which the system can read data from any non-erase-suspended sector. After completing a programming operation in the Erase Suspend mode, the system may once again read array data with the same exception. See “Erase Suspend/Erase Resume Commands” on page 35 for more information. The system must issue the reset command to return the device to the read (or erase-suspend-read) mode if DQ5 goes high during an active program or erase operation, or if the device is in the autoselect mode. See the next section, “Reset Command,” for more information. See “Reading Array Data” on page 29 in the Device Bus Operations section for more information. “See the table, “Read-Only Operations” on page 47 for the read parameters, and Figure 14 shows the timing diagram.
Autoselect Command Sequence
The autoselect command sequence allows the host system to access the manufacturer and device codes, and determine whether or not a sector is protected. Table 10 and Table 11 show the address and data requirements. This method is an alternative to that shown in Table 3, which is intended for PROM programmers and requires V ID on address pin A9. The autoselect command sequence may be written to an address that is either in the read or erase-suspend-read mode. The autoselect command may not be written while the device is actively programming or erasing. The autoselect command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle that contains the autoselect command. The device then enters the autoselect mode. The system may read at any address any number of times without initiating another autoselect command sequence: A read cycle at address XX00h returns the manufacturer code. Three read cycles at addresses 01h, 0Eh, and 0Fh return the device code. A read cycle to an address containing a sector address (SA), and the address 02h on A7–A0 in word mode returns 01h if the sector is protected, or 00h if it is unprotected. The system must write the reset command to return to the read mode (or erase-suspend-read mode if the device was previously in Erase Suspend).
Reset Command
Writing the reset command resets the device to the read or erase-suspend-read mode. Address bits are don’t cares for this command. The reset command may be written between the sequence cycles in an erase command sequence before erasing begins. This resets the device to the read mode. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to the read mode. If the program command sequence is
January 31, 2007 25270C7
Am29LV128MH/L
29
DATA
SHEET data is still “0.” Only erase operations can convert a “0” to a “1.”
Note: Single byte programming is not supported in x8-mode. Write buffer programming must be used during x8-mode operation.
Enter Secured Silicon Sector/Exit Secured Silicon Sector Command Sequence
The Secured Silicon Sector region provides a secured data area containing an 8-word/16-byte random Electronic Serial Number (ESN). The system can access the Secured Silicon Sector region by issuing the three-cycle Enter Secured Silicon Sector command sequence. The device continues to access the Secured Silicon Sector region until the system issues the four-cycle Exit Secured Silicon Sector command sequence. The Exit Secured Silicon Sector command sequence returns the device to normal operation. Table 10 and Table 11 show the address and data requirements for both command sequences. See also “Secured Silicon Sector Flash Memory Region” on page 24 for further information. Note: The write buffer, ACC function, and unlock bypass modes are not available when the Secured Silicon Sector is enabled.
Unlock Bypass Command Sequence The unlock bypass feature allows the system to program words to the device faster than using the standard program command sequence. The unlock bypass command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle containing the unlock bypass command, 20h. The device then enters the unlock bypass mode. A two-cycle unlock bypass program command sequence is all that is required to program in this mode. The first cycle in this sequence contains the unlock bypass program command, A0h; the second cycle contains the program address and data. Additional data is programmed in the same manner. This mode dispenses with the initial two unlock cycles required in the standard program command sequence, resulting in faster total programming time. Table 10 and Table 11 show the requirements for the command sequence. During the unlock bypass mode, only the Unlock Bypass Program and Unlock Bypass Reset commands are valid. To exit the unlock bypass mode, the system must issue the two-cycle unlock bypass reset command sequence. The first cycle must contain the data 90h. The second cycle must contain the data 00h. The device then returns to the read mode. Write Buffer Programming Write Buffer Programming allows the system write to a maximum of 16 words/32 bytes in one programming operation. This results in faster effective programming time than the standard programming algorithms. The Write Buffer Programming command sequence is initiated by first writing two unlock cycles. This is followed by a third write cycle containing the Write Buffer Load command written at the Sector Address in which programming will occur. The fourth cycle writes the sector address and the number of word locations, minus one, to be programmed. For example, if the system will program 6 unique address locations, then 05h should be written to the device. This tells the device how many write buffer addresses will be loaded with data and therefore when to expect the Program Buffer to Flash command. The number of locations to program cannot exceed the size of the write buffer or the operation will abort. The fifth cycle writes the first address location and data to be programmed. The write-buffer-page is selected by address bits AMAX–A 4. All subsequent add r e s s / d a t a p a i r s m u s t fa l l w i t h i n t h e selected-write-buffer-page. The system then writes the
Word Program Command Sequence
Programming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write cycles, followed by the program set-up command. The program address and data are written next, which in turn initiate the Embedded Program algorithm. The system is not required to provide further controls or timings. The device automatically provides internally generated program pulses and verifies the programmed cell margin. Table 10 and Table 11 show the address and data requirements for the word program command sequence. When the Embedded Program algorithm is complete, the device then returns to the read mode and addresses are no longer latched. The system can determine the status of the program operation by using DQ7 or DQ6. See “Wr ite Operation Status” on page 39 for information on these status bits. Any commands written to the device during the Embedded Program Algorithm are ignored. Note that a hardware reset immediately terminates the program operation. The program command sequence should be reinitiated once the device has returned to the read mode, to ensure data integrity. Note that the Secured Silicon Sector, autoselect, and CFI functions are unavailable when a program operation is in progress. Programming is allowed in any sequence and across sector boundaries. A b it cannot be programmed from “0” back to a “1.” A ttempting to do so may cause the device to set DQ5 = 1, or cause the DQ7 and DQ6 status bits to indicate the operation was successful. However, a succeeding read will show that the
30
Am29LV128MH/L
25270C7 January 31, 2007
DATA remaining address/data pairs into the write buffer. Write buffer locations may be loaded in any order. The write-buffer-page address must be the same for all address/data pairs loaded into the write buffer. (This means Write Buffer Programming cannot be performed across multiple write-buffer pages. This also means that Write Buffer Programming cannot be performed across multiple sectors. If the system attempts to load programming data outside of the selected write-buffer page, the operation will abort. Note that if a Write Buffer address location is loaded multiple times, the address/data pair counter will be decremented for every data load operation. The host s y s t e m mu s t t h e r e fo r e a c c o u n t fo r l o a d i n g a write-buffer location more than once. The counter decrements for each data load operation, not for each unique write-buffer-address location. Note also that if an address location is loaded more than once into the buffer, the final data loaded for that address will be programmed. Once the specified number of write buffer locations have been loaded, the system must then write the Program Buffer to Flash command at the sector address. Any other address and data combination aborts the Write Buffer Programming operation. The device then begins programming. Data polling should be used while monitoring the last address location loaded into the write buffer. DQ7, DQ6, DQ5, and DQ1 should be monitored to determine the device status during Write Buffer Programming. The write-buffer programming operation can be suspended using the standard program suspend/resume commands. Upon successful completion of the Write Buffer Programming operation, the device is ready to execute the next command. The Write Buffer Programming Sequence can be aborted in the following ways:
SHEET Load a value that is greater than the page buffer size during the Number of Locations to Program step. Write to an address in a sector different than the one specified during the Write-Buffer-Load command. Write an Address/Data pair to a different write-buffer-page than the one selected by the Starting Address during the write buffer data loading stage of the operation. Write data other than the Confirm Command after the specified number of data load cycles. The abort condition is indicated by DQ1 = 1, DQ7 = DATA# (for the last address location loaded), DQ6 = toggle, and DQ5=0. A Write-to-Buffer-Abort Reset command sequence must be written to reset the device for the next operation. Note that the full 3-cycle Write-to-Buffer-Abort Reset command sequence is required when using Write-Buffer-Programming features in Unlock Bypass mode. Accelerated Program The device offers accelerated program operations through the WP#/ACC pin. When the system asserts VHH on the WP#/ACC pin, the device automatically enters the Unlock Bypass mode. The system may then write the two-cycle Unlock Bypass program command sequence. The device uses the higher voltage on the WP#/ACC pin to accelerate the operation. Note that the WP#/ACC pin must not be at VHH for operations other than accelerated programming, or device damage may result. WP# has an internal pullup; when unconnected, WP# is at VIH. Figure 5 illustrates the algorithm for the program operation. Refer to the Erase and Program Operations table in the AC Characteristics section for parameters, and Figure 18 for timing diagrams.
January 31, 2007 25270C7
Am29LV128MH/L
31
DATA
SHEET
Write “Write to Buffer” command and Sector Address
Write number of addresses to program minus 1(WC) and Sector Address
Part of “Write to Buffer” Command Sequence
Write first address/data
Yes
WC = 0 ? No Abort Write to Buffer Operation? No Yes Write to buffer ABORTED. Must write “Write-to-buffer Abort Reset” command sequence to return to read mode. Write to a different sector address
(Note 1)
Write next address/data pair
WC = WC - 1
Write program buffer to flash sector address
Notes:
1. When Sector Address is specified, any address in the selected sector is acceptable. However, when loading Write-Buffer address locations with data, all addresses must fall within the selected Write-Buffer Page.
Read DQ7 - DQ0 at Last Loaded Address
2. 3.
DQ7 may change simultaneously with DQ5. Therefore, DQ7 should be verified. If this flowchart location was reached because DQ5= “1”, then the device FAILED. If this flowchart location was reached because DQ1= “1”, then the Write to Buffer operation was ABORTED. In either case, the proper reset command must be written before the device can begin another operation. If DQ1=1, write the Write-Buffer-Programming-Abort-Reset command. if DQ5=1, write the Reset command.
See Table 10 and Table 11 for command sequences required for write buffer programming.
DQ7 = Data? No No DQ1 = 1? Yes DQ5 = 1? Yes Read DQ7 - DQ0 with address = Last Loaded Address No
Yes
4.
(Note 2)
DQ7 = Data? No
Yes
(Note 3)
FAIL or ABORT
PASS
Figure 4.
Write Buffer Programming Operation
32
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
Program Suspend/Program Resume Command Sequence
START
Write Program Command Sequence
Embedded Program algorithm in progress
Data Poll from System
The Program Suspend command allows the system to interrupt a programming operation or a Write to Buffer programming operation so that data can be read from any non-suspended sector. When the Program Suspend command is written during a programming process, the device halts the program operation within 15 μs maximum (5 μs typical) and updates the status bits. Addresses are not required when writing the Program Suspend command. After the programming operation has been suspended, the system can read array data from any non-suspended sector. The Program Suspend command may also be issued during a programming operation while an erase is suspended. In this case, data may be read from any addresses not in Erase Suspend or Program Suspend. If a read is needed from the Secured Silicon Sector area (One-time Program area), then user must use the proper command sequences to enter and exit this region. The system may also write the autoselect command sequence when the device is in the Program Suspend mode. The system can read as many autoselect codes as required. When the device exits the autoselect mode, the device reverts to the Program Suspend mode, and is ready for another valid operation. See Autoselect Command Sequence for more information. After the Program Resume command is written, the device reverts to programming. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation Status” on page 39 for more information. The system must write the Program Resume command to exit the Program Suspend mode and continue the programming operation. Further writes of the Resume command are ignored. Another Program Suspend command can be written after the device has resume programming.
Verify Data?
No
Yes No
Increment Address
Last Address?
Yes Programming Completed
Note: See Table 10 and Table 11 for program command sequence.
Figure 5.
Program Operation
January 31, 2007 25270C7
Am29LV128MH/L
33
DATA
SHEET When the Embedded Erase algorithm is complete, the device returns to the read mode and addresses are no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write Operation Status” on page 39 for information on these status bits. Any commands written during the chip erase operation are ignored.However, note that a hardware reset immediately terminates the erase operation. If that occurs, the chip erase command sequence should be reinitiated once the device has returned to reading array data, to ensure data integrity. Note that the Secured Silicon Sector, autoselect, and CFI functions are unavailable when an program operation is in progress. Figure 6 illustrates the algorithm for the erase operation. Refer to the Erase and Program Operations tables in the AC Characteristics section for parameters, and Figure 20 section for timing diagrams.
Program Operation or Write-to-Buffer Sequence in Progress
Write address/data XXXh/B0h
Write Program Suspend Command Sequence Command is also valid for Erase-suspended-program operations
Wait 15 μs
Read data as required
Autoselect and SecSi Sector read operations are also allowed Data cannot be read from erase- or program-suspended sectors
No
Done reading? Yes Write address/data XXXh/30h Write Program Resume Command Sequence
Sector Erase Command Sequence
Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock cycles are written, and are then followed by the address of the sector to be erased, and the sector erase command. Table 9 and Table 10 show the address and data requirements for the sector erase command sequence. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically programs and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. After the command sequence is written, a sector erase time-out of 50 µs occurs. During the time-out period, additional sector addresses and sector erase commands may be written. Loading the sector erase buffer may be done in any sequence, and the number of sectors may be from one sector to all sectors. The time between these additional cycles must be less than 50 µs, otherwise erasure may begin. Any sector erase address and command following the exceeded time-out may or may not be accepted. It is recommended that processor interrupts be disabled during this time to ensure all commands are accepted. The interrupts can be re-enabled after the last Sector Erase command is written. Any command other than Sector Erase or Erase Suspend during the time-out period resets the device to the read mode. The system must rewrite the command sequence and any additional addresses and commands. Note that the Secured Silicon Sector, autoselect, and CFI functions are unavailable when an erase operation is in progress.
Device reverts to operation prior to Program Suspend
Figure 6. Program Suspend/Program Resume
Chip Erase Command Sequence
Chip erase is a six bus cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. Table 10 and Table 11 show the address and data requirements for the chip erase command sequence.
34
Am29LV128MH/L
25270C7 January 31, 2007
DATA The system can monitor DQ3 to determine if the sector erase timer has timed out (See the section on DQ3: Sector Erase Timer.). The time-out begins from the rising edge of the final WE# pulse in the command sequence. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by reading DQ7, DQ6, or DQ2 in the erasing sector. See “Write Operation Status” on page 39 for information on these status bits. Once the sector erase operation has begun, only the Erase Suspend command is valid. All other commands are ignored. However, note that a hardware reset immediately terminates the erase operation. If that occurs, the sector erase command sequence should be reinitiated once the device has returned to reading array data, to ensure data integrity. Figure 6 illustrates the algorithm for the erase operation. Refer to the Erase and Program Operations tables in the AC Characteristics section for parameters, and Figure 20 section for timing diagrams.
SHEET After the erase operation has been suspended, the device enters the erase-suspend-read mode. The system can read data from or program data to any sector not selected for erasure. (The device “erase suspends” all sectors selected for erasure.) Reading at any address within erase-suspended sectors produces status information on DQ7–DQ0. The system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is erase-suspended. See “Write Operation Status” on page 39 for information on these status bits. After an erase-suspended program operation is complete, the device returns to the erase-suspend-read mode. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard word program operation. See “Write Operation Status” on page 39 for more information. In the erase-suspend-read mode, the system can also issue the autoselect command sequence. Refer to the Autoselect Mode and Autoselect Command Sequence sections for details. To resume the sector erase operation, the system must write the Erase Resume command. Further writes of the Resume command are ignored. Another Erase Suspend command can be written after the chip has resumed erasing. Note: During an erase operation, this flash device performs multiple internal operations which are invisible to the system. When an erase operation is suspended, any of the internal operations that were not fully completed must be restarted. As such, if this flash device is continually issued suspend/resume commands in rapid succession, erase progress will be impeded as a function of the number of suspends. The result will be a longer cumulative erase time than without suspends. Note that the additional suspends do not affect device reliability or future performance. In most systems rapid erase/suspend activity occurs only briefly. In such cases, erase performance will not be significantly impacted.
Erase Suspend/Erase Resume Commands
The Erase Suspend command, B0h, allows the system to interrupt a sector erase operation and then read data from, or program data to, any sector not selected for erasure. This command is valid only during the sector erase operation, including the 50 µs time-out period during the sector erase command sequence. The Erase Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm. When the Erase Suspend command is written during the sector erase operation, the device requires a typical of 5 µs (maximum of 20 µs) to suspend the erase operation. However, when the Erase Suspend command is written during the sector erase time-out, the device immediately terminates the time-out period and suspends the erase operation.
January 31, 2007 25270C7
Am29LV128MH/L
35
DATA
SHEET
START
Write Erase Command Sequence (Notes 1, 2)
Data Poll to Erasing Bank from System
Embedded Erase algorithm in progress
No
Data = FFh?
Yes Erasure Completed
Figure 7.
Erase Operation
Notes: 1. See Table 10 and Table 11 for erase command sequence. 2. See the section on DQ3 for information on the sector erase timer.
36
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
Command Definitions
Table 10.
Command Sequence (Note 1) Read (Note 6) Reset (Note 7) Autoselect (Note 8) Manufacturer ID Device ID (Note 9) Secured Silicon Sector Factory Protect (Note 10) Sector Group Protect Verify (Note 12) Cycles
Command Definitions (x16 Mode, BYTE# = VIH)
Bus Cycles (Notes 2–5) First Second Addr Data Third Addr Data Fourth Addr Data Fifth Addr Data Sixth Addr Data
Addr RA XXX 555 555 555 555 555 555 555 555 SA 555 555 XXX XXX 555 555 XXX XXX 55
Data RD F0 AA AA AA AA AA AA AA AA 29 AA AA A0 90 AA AA B0 30 98
1 1 4 4 4 4 3 4 4 3 1 3 3 2 2 6 6 1 1 1
2AA 2AA 2AA 2AA 2AA 2AA 2AA 2AA 2AA 2AA PA XXX 2AA 2AA
55 55 55 55 55 55 55 55 55 55 PD 00 55 55
555 555 555 555 555 555 555 SA 555 555
90 90 90 90 88 90 A0 25 F0 20
X00 X01 X03 (SA)X02
0001 227E (Note 10) 00/01 X0E 2212 X0F 2200
Enter Secured Silicon Sector Region Exit Secured Silicon Sector Region Program Write to Buffer (Note 11) Program Buffer to Flash Write to Buffer Abort Reset (Note 13) Unlock Bypass Unlock Bypass Program (Note 14) Unlock Bypass Reset (Note 15) Chip Erase Sector Erase Program/Erase Suspend (Note 16) Program/Erase Resume (Note 17) CFI Query (Note 18)
XXX PA SA
00 PD WC PA PD WBL PD
555 555
80 80
555 555
AA AA
2AA 2AA
55 55
555 SA
10 30
Legend: X = Don’t care RA = Read Address of the memory location to be read. RD = Read Data read from location RA during read operation. PA = Program Address. Addresses latch on the falling edge of the WE# or CE# pulse, whichever happens later. PD = Program Data for location PA. Data latches on the rising edge of WE# or CE# pulse, whichever happens first. Notes: 1. See Table 1 for description of bus operations. 2. All values are in hexadecimal. 3. 4. 5. 6. 7. Except for the read cycle and the fourth cycle of the autoselect command sequence, all bus cycles are write cycles. Data bits DQ15–DQ8 are don’t care in command sequences, except for RD, PD, and WC. Unless otherwise noted, address bits A22–A11 are don’t cares. No unlock or command cycles required when device is in read mode. The Reset command is required to return to the read mode (or to the erase-suspend-read mode if previously in Erase Suspend) when the device is in the autoselect mode, or if DQ5 goes high while the device is providing status information. The fourth cycle of the autoselect command sequence is a read cycle. Data bits DQ15–DQ8 are don’t care. See the Autoselect Command Sequence section for more information. The device ID must be read in three cycles.
SA = Sector Address of sector to be verified (in autoselect mode) or erased. Address bits A22–A15 uniquely select any sector. WBL = Write Buffer Location. Address must be within the same write buffer page as PA. WC = Word Count. Number of write buffer locations to load minus 1.
lowest address sector, the data is 88h for factory locked and 08h for not factor locked. 11. The total number of cycles in the command sequence is determined by the number of words written to the write buffer. The maximum number of cycles in the command sequence is 21. 12. The data is 00h for an unprotected sector and 01h for a protected sector. 13. Command sequence resets device for next command after aborted write-to-buffer operation. 14. The Unlock Bypass command is required prior to the Unlock Bypass Program command. 15. The Unlock Bypass Reset command is required to return to the read mode when the device is in the unlock bypass mode. 16. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode. The Erase Suspend command is valid only during a sector erase operation. 17. The Erase Resume command is valid only during the Erase Suspend mode.
18. Command is valid when device is ready to read array data or when device is in autoselect mode.
8.
9.
10. If WP# protects the highest address sector, the data is 98h for factory locked and 18h for not factory locked. If WP# protects the
January 31, 2007 25270C7
Am29LV128MH/L
37
DATA Table 11.
Command Sequence (Note 1) Read (Note 6) Reset (Note 7) Autoselect (Note 8) Manufacturer ID Device ID (Note 9) Secured Silicon Sector Factory Protect (Note 10) Sector Group Protect Verify (Note 12) Cycles
SHEET
Command Definitions (x8 Mode, BYTE# = VIL)
Bus Cycles (Notes 2–5) First Second Addr Data Third Addr Data Fourth Addr Data Fifth Addr Data Sixth Addr Data
Addr RA XXX AAA AAA AAA AAA AAA AAA 555 AAA SA AAA AAA XXX XXX AAA AAA XXX XXX AA
Data RD F0 AA AA AA AA AA AA AA AA 29 AA AA A0 90 AA AA B0 30 98
1 1 4 4 4 4 3 4 4 3 1 3 3 2 2 6 6 1 1 1
555 555 555 555 555 555 2AA 555 555 555 PA XXX 555 555
55 55 55 55 55 55 55 55 55 55 PD 00 55 55
AAA AAA AAA AAA AAA AAA 555 SA AAA AAA
90 90 90 90 88 90 A0 25 F0 20
X00 X02 X06 (SA)X04
01 7E (Note 10) 00/01 X1C 12 X1E 00
Enter Secured Silicon Sector Region Exit Secured Silicon Sector Region Program Write to Buffer (Note 11) Program Buffer to Flash Write to Buffer Abort Reset (Note 13) Unlock Bypass Unlock Bypass Program (Note 14) Unlock Bypass Reset (Note 15) Chip Erase Sector Erase Program/Erase Suspend (Note 16) Program/Erase Resume (Note 17) CFI Query (Note 18)
XXX PA SA
00 PD BC PA PD WBL PD
AAA AAA
80 80
AAA AAA
AA AA
555 555
55 55
AAA SA
10 30
Legend: X = Don’t care RA = Read Address of the memory location to be read. RD = Read Data read from location RA during read operation. PA = Program Address. Addresses latch on the falling edge of the WE# or CE# pulse, whichever happens later. PD = Program Data for location PA. Data latches on the rising edge of WE# or CE# pulse, whichever happens first. Notes: 1. See Table 1 for description of bus operations. 2. All values are in hexadecimal. 3. 4. 5. 6. 7. Except for the read cycle and the fourth cycle of the autoselect command sequence, all bus cycles are write cycles. Data bits DQ15–DQ8 are don’t care in command sequences, except for RD and PD. Unless otherwise noted, address bits A22–A11 are don’t cares. No unlock or command cycles required when device is in read mode. The Reset command is required to return to the read mode (or to the erase-suspend-read mode if previously in Erase Suspend) when the device is in the autoselect mode, or if DQ5 goes high while the device is providing status information. The fourth cycle of the autoselect command sequence is a read cycle. Data bits DQ15–DQ8 are don’t care. See the Autoselect Command Sequence section for more information. The device ID must be read in three cycles.
SA = Sector Address of sector to be verified (in autoselect mode) or erased. Address bits A22–A15 uniquely select any sector. WBL = Write Buffer Location. Address must be within the same write buffer page as PA. BC = Byte Count. Number of write buffer locations to load minus 1.
lowest address sector, the data is 88h for factory locked and 08h for not factor locked. 11. The total number of cycles in the command sequence is determined by the number of words written to the write buffer. The maximum number of cycles in the command sequence is 37. 12. The data is 00h for an unprotected sector group and 01h for a protected sector group. 13. Command sequence resets device for next command after aborted write-to-buffer operation. 14. The Unlock Bypass command is required prior to the Unlock Bypass Program command. 15. The Unlock Bypass Reset command is required to return to the read mode when the device is in the unlock bypass mode. 16. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode. The Erase Suspend command is valid only during a sector erase operation. 17. The Erase Resume command is valid only during the Erase Suspend mode.
18. Command is valid when device is ready to read array data or when device is in autoselect mode.
8.
9.
10. If WP# protects the highest address sector, the data is 98h for factory locked and 18h for not factory locked. If WP# protects the
38
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
WRITE OPERATION STATUS
The device provides several bits to determine the status of a program or erase operation: DQ2, DQ3, DQ5, DQ6, and DQ7. Table 12 and the following subsections describe the function of these bits. DQ7 and DQ6 each offer a method for determining whether a program or erase operation is complete or in progress. The device also provides a hardware-based output signal, RY/BY#, to determine whether an Embedded Program or Erase operation is in progress or has been completed. valid data, the data outputs on DQ0–DQ6 may be still invalid. Valid data on DQ0–DQ7 will appear on successive read cycles. Table 12 shows the outputs for Data# Polling on DQ7. Figure 8 shows the Data# Polling algorithm. Figure 21 in the AC Characteristics section shows the Data# Polling timing diagram.
DQ7: Data# Polling
The Data# Polling bit, DQ7, indicates to the host system whether an Embedded Program or Erase algorithm is in progress or completed, or whether the device is in Erase Suspend. Data# Polling is valid after the rising edge of the final WE# pulse in the command sequence. During the Embedded Program algorithm, the device outputs on DQ7 the complement of the datum programmed to DQ7. This DQ7 status also applies to programming during Erase Suspend. When the Embedded Program algorithm is complete, the device outputs the datum programmed to DQ7. The system must provide the program address to read valid status information on DQ7. If a program address falls within a protected sector, Data# Polling on DQ7 is active for approximately 1 µs, then the device returns to the read mode. During the Embedded Erase algorithm, Data# Polling produces a “0” on DQ7. When the Embedded Erase algorithm is complete, or if the device enters the Erase Suspend mode, Data# Polling produces a “1” on DQ7. The system must provide an address within any of the sectors selected for erasure to read valid status information on DQ7. After an erase command sequence is written, if all sectors selected for erasing are protected, Data# Polling on DQ7 is active for approximately 100 µs, then the device returns to the read mode. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. However, if the system reads DQ7 at an address within a protected sector, the status may not be valid. Just prior to the completion of an Embedded Program or Erase operation, DQ7 may change asynchronously with DQ0–DQ6 while Output Enable (OE#) is asserted low. That is, the device may change from providing status information to valid data on DQ7. Depending on when the system samples the DQ7 output, it may read the status or valid data. Even if the device has completed the program or erase operation and DQ7 has
START
Read DQ7–DQ0 Addr = VA
DQ7 = Data?
Yes
No No
DQ5 = 1?
Yes Read DQ7–DQ0 Addr = VA
DQ7 = Data?
Yes
No FAIL PASS
Notes: 1. VA = Valid address for programming. During a sector erase operation, a valid address is any sector address within the sector being erased. During chip erase, a valid address is any non-protected sector address. 2. DQ7 should be rechecked even if DQ5 = “1” because DQ7 may change simultaneously with DQ5.
Figure 8.
Data# Polling Algorithm
January 31, 2007 25270C7
Am29LV128MH/L
39
DATA
SHEET After an erase command sequence is written, if all sectors selected for erasing are protected, DQ6 toggles for approximately 100 µs, then returns to reading array data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. The system can use DQ6 and DQ2 together to determine whether a sector is actively erasing or is erase-suspended. When the device is actively erasing (that is, the Embedded Erase algorithm is in progress), DQ6 toggles. When the device enters the Erase Suspend mode, DQ6 stops toggling. However, the system must also use DQ2 to determine which sectors are erasing or erase-suspended. Alternatively, the system can use DQ7. See “DQ7: Data# Polling” on page 39. If a program address falls within a protected sector, DQ6 toggles for approximately 1 μs after the program command sequence is written, then returns to reading array data. DQ6 also toggles during the erase-suspend-program mode, and stops toggling once the Embedded Program algorithm is complete. Table 12 shows the outputs for Toggle Bit I on DQ6. Figure 9 shows the toggle bit algorithm. Figure 22 in the “AC Characteristics” section shows the toggle bit timing diagrams. Figure 23 shows the differences between DQ2 and DQ6 in graphical form. See “DQ2: Toggle Bit II” on page 41.
RY/BY#: Ready/Busy#
The RY/BY# is a dedicated, open-drain output pin which indicates whether an Embedded Algorithm is in progress or complete. The RY/BY# status is valid after the rising edge of the final WE# pulse in the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a pull-up resistor to VCC. If the output is low (Busy), the device is actively erasing or programming. (This includes programming in the Erase Suspend mode.) If the output is high (Ready), the device is in the read mode, the standby mode, or in the erase-suspend-read mode. Table 12 shows the outputs for RY/BY#.
DQ6: Toggle Bit I
Toggle Bit I on DQ6 indicates whether an Embedded Program or Erase algorithm is in progress or complete, or whether the device has entered the Erase Suspend mode. Toggle Bit I may be read at any address, and is valid after the rising edge of the final WE# pulse in the command sequence (prior to the program or erase operation), and during the sector erase time-out. During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause DQ6 to toggle. The system may use either OE# or CE# to control the read cycles. When the operation is complete, DQ6 stops toggling.
40
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
DQ2: Toggle Bit II
START
Read DQ7–DQ0
The “Toggle Bit II” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erase-suspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system reads at addresses within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and mode information. Refer to Table 12 to compare outputs for DQ2 and DQ6. Figure 9 shows the toggle bit algorithm in flowchart form, and “DQ2: Toggle Bit II” explains the algorithm. See also the “RY/BY#: Ready/Busy#” subsection. Figure 22 shows the toggle bit timing diagram. Figure 23 shows the differences between DQ2 and DQ6 in graphical form.
Read DQ7–DQ0
Toggle Bit = Toggle? Yes
No
No
DQ5 = 1?
Yes
Read DQ7–DQ0 Twice
Reading Toggle Bits DQ6/DQ2
Refer to Figure 9 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, the system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, if after the initial two read cycles, the system determines that the toggle bit is still toggling, the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not completed the operation successfully, and the system must write the reset command to return to reading array data. The remaining scenario is that the system initially determines that the toggle bit is toggling and DQ5 has not gone high. The system may continue to monitor the toggle bit and DQ5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform
Toggle Bit = Toggle?
No
Yes Program/Erase Operation Not Complete, Write Reset Command Program/Erase Operation Complete
Note: T he system should recheck the toggle bit even if DQ5 = “1” because the toggle bit may stop toggling as DQ5 changes to “1.” See the subsections on DQ6 and DQ2 for more information.
Figure 9.
Toggle Bit Algorithm
January 31, 2007 25270C7
Am29LV128MH/L
41
DATA other system tasks. In this case, the system must start at the beginning of the algorithm when it returns to determine the status of the operation (top of Figure 9).
SHEET mand. When the time-out period is complete, DQ3 switches from a “0” to a “1.” If the time between additional sector erase commands from the system can be assumed to be less than 50 µs, the system need not monitor DQ3. See “Sector Erase Command Sequence” on page 34. After the sector erase command is written, the system should read the status of DQ7 (Data# Polling) or DQ6 (Toggle Bit I) to ensure that the device has accepted the command sequence, and then read DQ3. If DQ3 is “1,” the Embedded Erase algorithm has begun; all further commands (except Erase Suspend) are ignored until the erase operation is complete. If DQ3 is “0,” the device will accept additional sector erase commands. To ensure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3 is high on the second status check, the last command might not have been accepted. Table 12 shows the status of DQ3 relative to the other status bits.
DQ5: Exceeded Timing Limits
DQ5 indicates whether the program, erase, or write-to-buffer time has exceeded a specified internal pulse count limit. Under these conditions DQ5 produces a “1,” indicating that the program or erase cycle was not successfully completed. The device may output a “1” on DQ5 if the system tries to program a “1” to a location that was previously programmed to “0.” O nly an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the timing limit has been exceeded, DQ5 produces a “1.” In all these cases, the system must write the reset command to return the device to the reading the array (or to erase-suspend-read if the device was previously in the erase-suspend-program mode).
DQ3: Sector Erase Timer
After writing a sector erase command sequence, the system may read DQ3 to determine whether or not erasure has begun. (The sector erase timer does not apply to the chip erase command.) If additional sectors are selected for erasure, the entire time-out also applies after each additional sector erase com-
DQ1: Write-to-Buffer Abort
DQ1 indicates whether a Write-to-Buffer operation was aborted. Under these conditions DQ1 produces a “1”. The system must issue the Write-to-Buffer-Abort-Reset command sequence to return the device to reading array data. See “Write Buffer Programming” on page 30 for more details.
42
Am29LV128MH/L
25270C7 January 31, 2007
DATA Table 12.
SHEET
Write Operation Status
DQ6 Toggle Toggle DQ5 (Note 1) 0 0 DQ3 N/A 1 DQ2 (Note 2) No toggle Toggle DQ1 0 N/A RY/BY# 0 0 1 1 N/A Data Toggle Toggle Toggle 0 0 0 N/A N/A N/A N/A N/A N/A N/A 0 1 Toggle N/A 1 1 0 0 0
Standard Mode Program Suspend Mode
Erase Suspend Mode
Write-toBuffer
DQ7 Status (Note 2) Embedded Program Algorithm DQ7# Embedded Erase Algorithm 0 Program-Suspended Program- Sector Suspend Non-Program Read Suspended Sector Erase-Suspended 1 EraseSector Suspend Non-Erase Suspended Read Sector Erase-Suspend-Program DQ7# (Embedded Program) Busy (Note 3) DQ7# Abort (Note 4) DQ7#
Invalid (not allowed) Data No toggle 0
Notes: 1. DQ5 switches to ‘1’ when an Embedded Program, Embedded Erase, or Write-to-Buffer operation has exceeded the maximum timing limits. Refer to the section on DQ5 for more information. 2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details. 3. The Data# Polling algorithm should be used to monitor the last loaded write-buffer address location. 4. DQ1 switches to ‘1’ when the device has aborted the write-to-buffer operation.
January 31, 2007 25270C7
Am29LV128MH/L
43
DATA
SHEET
ABSOLUTE MAXIMUM RATINGS
Storage Temperature Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C Ambient Temperature with Power Applied. . . . . . . . . . . . . . –65°C to +125°C Voltage with Respect to Ground VCC (Note 1) . . . . . . . . . . . . . . . . . –0.5 V to +4.0 V VIO . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to +4.0 V A9, OE#, ACC, and RESET# (Note 2) . . . . . . . . . . . . . . . . . . . . –0.5 V to +12.5 V All other pins (Note 1) . . . . . . –0.5 V to VCC +0.5 V Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes: 1. Minimum DC voltage on input or I/O pins is –0.5 V. Dur ing voltage transitions, input or I/O pins may overshoot V SS t o –2.0 V for periods of up to 20 ns. Maximum DC voltage on input or I/O pins is VCC +0.5 V. See Figure 10. During voltage transitions, input or I/O pins may overshoot to VCC +2.0 V for periods up to 20 ns. See Figure 11. 2. Minimum DC input voltage on pins A9, OE#, ACC, and RESET# is –0.5 V. During voltage transitions, A9, OE#, ACC, and RESET# may overshoot V SS t o –2.0 V for periods of up to 20 ns. See Figure 10. Maximum DC input voltage on pin A9, OE#, ACC, and RESET# is +12.5 V which may overshoot to +14.0 V for periods up to 20 ns. 3. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second. Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational sections of this data sheet is not implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect device reliability. +0.8 V –0.5 V –2.0 V 20 ns 20 ns 20 ns
Figure 10. Maximum Negative Overshoot Waveform
20 ns VCC +2.0 V VCC +0.5 V 2.0 V 20 ns 20 ns
Figure 11. Maximum Positive Overshoot Waveform
OPERATING RANGES
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . . . . . . –40°C to +85°C
Supply Voltages
VCC (regulated voltage range) . . . . . . . . . . . . . . . . 3.0–3.6 V VCC (full voltage range) . . . . . . . . . . . . . . . . . . . . . 2.7–3.6 V VIO (Note 2) . . . . . . . . . . . . . . . . . . . . . . 1.65–3.6 V (Note 3) Notes:
1. Operating ranges define those limits between which the functionality of the device is guaranteed.
2. See “Ordering Information” on page 10 for valid VCC/VIO range combinations. The I/Os will not operate at 3V when VIO = 1.8V. 3. 100R parts have a VIO range from 2.7–3.6 V.
44
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
DC CHARACTERISTICS CMOS Compatible
Parameter Symbol ILI ILIT ILO ILR ICC1 Parameter Description (Notes) Input Load Current (1) A9, ACC Input Load Current Output Leakage Current Reset Leakage Current VCC Active Read Current (2, 3) Test Conditions VIN = VSS to VCC, VCC = VCC max VCC = VCC max; A9 = 12.5 V VOUT = VSS to VCC, VCC = VCC max VCC = VCC max; RESET# = 12.5 V CE# = VIL, OE# = VIH, 5 MHz 1 MHz 1 MHz 10 MHz 10 MHz 33 MHz 3 13 4 40 3 6 50 1 1 1 –0.5 1.9 –0.5 1.9 VCC = 2.7–3.6 V VCC = 2.7–3.6 V IOL = 4.0 mA, VCC = VCC min = VIO IOH = –2.0 mA, VCC = VCC min = VIO IOH = –100 µA, VCC = VCC min = VIO 0.85 VIO VIO–0.4 2.3 2.5 11.5 11.5 Min Typ Max ±1.0 35 ±1.0 35 34 43 50 80 20 40 60 5 5 5 0.8 VCC + 0.5 0.3 x VIO VIO + 0.5 12.5 12.5 0.15 x VIO mA mA µA µA µA V V V V V V V V V V mA Unit µA µA µA µA mA
ICC2
VCC Initial Page Read Current (2, 3) CE# = VIL, OE# = VIH
ICC3 ICC4 ICC5 ICC6 ICC7 VIL1 VIH1 VIL2 VIH2 VHH VID VOL VOH1 VOH2 VLKO
VCC Intra-Page Read Current (2, 3) VCC Active Write Current (3, 4) VCC Standby Current (3) VCC Reset Current (3) Automatic Sleep Mode (3, 5) Input Low Voltage 1(6, 7) Input High Voltage 1 (6, 7) Input Low Voltage 2 (6, 8) Input High Voltage 2 (6, 8) Voltage for ACC Program Acceleration Voltage for Autoselect and Temporary Sector Unprotect Output Low Voltage (10) Output High Voltage Low VCC Lock-Out Voltage (9)
CE# = VIL, OE# = VIH CE# = VIL, OE# = VIH
CE#, RESET# = VCC ± 0.3 V, WP# = VIH RESET# = VSS ± 0.3 V, WP# = VIH VIH = VCC ± 0.3 V; VIL = VSS ± 0.3 V, WP# = VIH
Notes: 1. On the WP#/ACC pin only, the maximum input load current when WP# = VIL is ± 5.0 µA. 2. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH. 3. 4. Maximum ICC specifications are tested with VCC = VCCmax. ICC active while Embedded Erase or Embedded Program is in progress.
5. 6. 7. 8. 9.
Automatic sleep mode enables the low power mode when addresses remain stable for tACC + 30 ns. If VIO < VCC, maximum VIL for CE# and DQ I/Os is 0.3 VIO. Maximum VIH for these connections is VIO + 0.3 V VCC voltage requirements. VIO voltage requirements. Not 100% tested.
10. Includes RY/BY#
January 31, 2007 25270C7
Am29LV128MH/L
45
DATA
SHEET
TEST CONDITIONS
Table 13.
3.3 V 2.7 kΩ Test Condition Output Load Output Load Capacitance, CL (including jig capacitance) CL 6.2 kΩ Input Rise and Fall Times Input Pulse Levels Input timing measurement reference levels (See Note) Note: Diodes are IN3064 or equivalent Output timing measurement reference levels
Test Specifications
All Speeds 1 TTL gate 30 5 0.0–3.0 1.5 0.5 VIO pF ns V V V Unit
Device Under Test
Figure 12.
Test Setup
Note: If VIO < VCC, the reference level is 0.5 VIO.
KEY TO SWITCHING WAVEFORMS
WAVEFORM INPUTS Steady Changing from H to L Changing from L to H Don’t Care, Any Change Permitted Does Not Apply Changing, State Unknown Center Line is High Impedance State (High Z) OUTPUTS
3.0 V 0.0 V
Input
1.5 V
Measurement Level
0.5 VIO V
Output
Note: If VIO < VCC, the input measurement reference level is 0.5 VIO.
Figure 13.
Input Waveforms and Measurement Levels
46
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS Read-Only Operations
Parameter 103, 103R 100 100 100 30 30 30 30 Speed Options
JEDEC tAVAV tAVQV tELQV
Std. Description tRC tACC tCE Read Cycle Time (Note 1) Address to Output Delay Chip Enable to Output Delay
Test Setup Min CE#, OE# = VIL OE# = VIL Max Max Max Max Max Max Min Min Min
93R 90 90 90 25 25
113 110 110 110
113R
123 120 120 120
123R
Unit ns ns ns
tPACC Page Access Time tGLQV tEHQZ tGHQZ tAXQX tOE tDF tDF tOH Output Enable to Output Delay Chip Enable to Output High Z (Note 1) Output Enable to Output High Z (Note 1) Output Hold Time From Addresses, CE# or OE#, Whichever Occurs First Read Output Enable Hold Time (Note 1) Toggle and Data# Polling
40 40 16 16 0 0 10
30 30
40 40
ns ns ns ns ns ns ns
tOEH
Notes: 1. Not 100% tested. 2. See Figure 12 and Table 13 for test specifications. 3. AC Specifications listed are tested with VIO = VCC. Contact AMD for information on AC operation with VIO ≠ VCC.
tRC Addresses CE# tRH tRH OE# tOEH WE# HIGH Z Outputs RESET# RY/BY# Output Valid tCE tOH HIGH Z tOE tDF Addresses Stable tACC
0V
Figure 14.
Read Operation Timings
January 31, 2007 25270C7
Am29LV128MH/L
47
DATA
SHEET
AC CHARACTERISTICS
A22-A2 Same Page
A1-A0*
Aa
tACC
Ab
tPACC
Ac
tPACC tPACC
Ad
Data Bus CE# OE#
Qa
Qb
Qc
Qd
* Figure shows word mode. Addresses are A1–A-1 for byte mode.
Figure 15.
Page Read Timings
48
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS Hardware Reset (RESET#)
Parameter JEDEC Std. tReady tReady tRP tRH tRPD tRB Note:
1. 2. Not 100% tested. AC Specifications listed are tested with VIO = VCC. Contact AMD for information on AC operation with VIO
Description RESET# Pin Low (During Embedded Algorithms) to Read Mode (See Note) RESET# Pin Low (NOT During Embedded Algorithms) to Read Mode (See Note) RESET# Pulse Width Reset High Time Before Read (See Note) RESET# Low to Standby Mode RY/BY# Recovery Time Max Max Min Min Min Min
All Speed Options 20 500 500 50 20 0
Unit μs ns ns ns μs ns
≠ VCC.
RY/BY#
CE#, OE# tRH RESET# tRP tReady
Reset Timings NOT during Embedded Algorithms Reset Timings during Embedded Algorithms
tReady RY/BY# tRB CE#, OE#
RESET# tRP
Figure 16.
Reset Timings
January 31, 2007 25270C7
Am29LV128MH/L
49
DATA
SHEET
AC CHARACTERISTICS Erase and Program Operations
Parameter JEDEC tAVAV tAVWL Std. tWC tAS tASO tWLAX tAH tAHT tDVWH tWHDX tDS tDH tOEPH tGHWL tELWL tWHEH tWLWH tWHDL tGHWL tCS tCH tWP tWPH Description Write Cycle Time (Note 1) Address Setup Time Address Setup Time to OE# low during toggle bit polling Address Hold Time Address Hold Time From CE# or OE# high during toggle bit polling Data Setup Time Data Hold Time Output Enable High during toggle bit polling Read Recovery Time Before Write (OE# High to WE# Low) CE# Setup Time CE# Hold Time Write Pulse Width Write Pulse Width High Write Buffer Program Operation (Notes 2, 3) Effective Write Buffer Program Operation (Notes 2, 4) Accelerated Effective Write Buffer Program Operation (Notes 2, 4) Single Byte/Word Program Operation (Note 2, 5) Accelerated Single Byte/Word Programming Operation (Note 2, 5) tWHWH2 tWHWH2 tVHH tVCS tBUSY Sector Erase Operation (Note 2) VHH Rise and Fall Time (Note 1) VCC Setup Time (Note 1) Erase/Program Valid to RY/BY# Delay Program Valid Before Status Polling (Note 7) Per Byte Per Word Per Byte Per Word Byte Word Byte Word Min Min Min Min Min Min Min Min Min Min Min Min Min Typ Typ Typ Typ Typ Typ Typ Typ Typ Typ Min Min Max Max 93R 90 Speed Options 103, 103R 100 0 15 45 0 45 0 20 0 0 0 35 30 240 7.5 µs 15 6.25 12.5 60 µs 60 54 54 0.5 250 50 90 4 µs µs sec ns µs ns µs µs µs 113, 113R 123, 123R Unit 110 120 ns ns ns ns ns ns ns ns ns ns ns ns ns µs
tWHWH1
tWHWH1
tPOLL
Notes: 1. Not 100% tested. 2. See the “Erase And Programming Performance” on page 60 for more information. 3. For 1–16 words/1–32 bytes programmed. 4. Effective write buffer specification is based upon a 16-word/32-byte write buffer operation 5. Byte/Word programming specification is based upon a single word/byte programming operation not utilizing the write buffer. 6. AC Specifications listed are tested with VIO = VCC. Contact AMD for information on AC operation with VIO ≠ VCC. 7. When using the program suspend/resume feature, if the suspend command is issued within tPOLL, tPOLL must be fully re-applied upon resuming the programming operation. If the suspend command is issued after tPOLL, tPOLL is not required again prior to reading the status bits upon resuming.
50
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
RY/BY#
CE#, OE# tRH RESET# tRP tReady
Reset Timings NOT during Embedded Algorithms Reset Timings during Embedded Algorithms
tReady RY/BY# tRB CE#, OE#
RESET# tRP
Figure 17.
Reset Timings
January 31, 2007 25270C7
Am29LV128MH/L
51
DATA
SHEET
AC CHARACTERISTICS
Program Command Sequence (last two cycles) tWC Addresses 555h tAS PA tAH CE# OE# tPOLL tWP WE# tCS tDS Data tDH PD tBUSY RY/BY# Status DOUT tRB tWPH tWHWH1 PA PA Read Status Data (last two cycles)
tCH
A0h
VCC tVCS
Notes: 1. PA = program address, PD = program data, DOUT is the true data at the program address. 2. Illustration shows device in word mode.
Figure 18.
Program Operation Timings
VHH
ACC
VIL or VIH tVHH tVHH
VIL or VIH
Figure 19.
Accelerated Program Timing Diagram
52
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS
Erase Command Sequence (last two cycles) tWC Addresses 2AAh tAS SA
555h for chip erase
Read Status Data
VA tAH
VA
CE#
OE# tWP WE# tCS tDS
tCH
tWPH
tWHWH2
tDH Data 55h 30h
10 for Chip Erase In Progress Complete
tBUSY RY/BY# tVCS VCC
tRB
Notes: 1. SA = sector address (for Sector Erase), VA = Valid Address for reading status data. See “Write Operation Status” on page 39. 2. These waveforms are for the word mode.
Figure 20.
Chip/Sector Erase Operation Timings
January 31, 2007 25270C7
Am29LV128MH/L
53
DATA
SHEET
AC CHARACTERISTICS
tRC Addresses tPOLL CE# tCH OE# tOEH WE# tOH DQ15 and DQ7
Complement Complement True Valid Data
High Z
VA tACC tCE
VA
VA
tOE tDF
DQ14–DQ8, DQ6–DQ0 tBUSY RY/BY#
Status Data
Status Data
True
Valid Data
High Z
Note: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data read cycle.
Figure 21. Data# Polling Timings (During Embedded Algorithms)
54
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS
tAHT Addresses
tAS
tAHT tASO CE# tOEH WE# tOEPH OE# tDH DQ6/DQ2 Valid Data
Valid Status
tCEPH
tOE
Valid Status Valid Status
Valid Data
(first read) RY/BY#
(second read)
(stops toggling)
Note: VA = Valid address; not required for DQ6. Illustration shows first two status cycle after command sequence, last status read cycle, and array data read cycle.
Figure 22.
Toggle Bit Timings (During Embedded Algorithms)
Enter Embedded Erasing WE#
Erase Suspend Erase
Enter Erase Suspend Program Erase Suspend Program
Erase Resume Erase Suspend Read Erase Erase Complete
Erase Suspend Read
DQ6
DQ2 Note: DQ2 toggles only when read at an address within an erase-suspended sector. The system may use OE# or CE# to toggle DQ2 and DQ6.
Figure 23. DQ2 vs. DQ6
January 31, 2007 25270C7
Am29LV128MH/L
55
DATA
SHEET
AC CHARACTERISTICS Temporary Sector Group Unprotect
Parameter JEDEC Std tVIDR tRSP Note: 1. Not 100% tested. 2. AC Specifications listed are tested with VIO = VCC. Contact AMD for information on AC operation with VIO ≠ VCC. Description VID Rise and Fall Time (See Note) RESET# Setup Time for Temporary Sector Unprotect Min Min All Speed Options 500 4 Unit ns µs
VID RESET# VSS, VIL, or VIH tVIDR Program or Erase Command Sequence CE# tVIDR
VID VSS, VIL, or VIH
WE# tRSP RY/BY# tRRB
Figure 24.
Temporary Sector Group Unprotect Timing Diagram
56
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS
VID VIH
RESET#
SA, A6, A1, A0
Valid* Sector Group Protect or Unprotect
Valid* Verify 40h
Sector Group Protect: 150 µs, Sector Group Unprotect: 15 ms
Valid*
Data
60h
60h
Status
1 µs CE#
WE#
OE#
* For sector group protect, A6 = 0, A1 = 1, A0 = 0. For sector group unprotect, A6 = 1, A1 = 1, A0 = 0.
Figure 25.
Sector Group Protect and Unprotect Timing Diagram
January 31, 2007 25270C7
Am29LV128MH/L
57
DATA
SHEET
AC CHARACTERISTICS Alternate CE# Controlled Erase and Program Operations
Parameter JEDEC tAVAV tAVWL tELAX tDVEH tEHDX tGHEL tWLEL tEHWH tELEH tEHEL Std. tWC tAS tAH tDS tDH tGHEL tWS tWH tCP tCPH Description Write Cycle Time (Note 1) Address Setup Time Address Hold Time Data Setup Time Data Hold Time Read Recovery Time Before Write (OE# High to WE# Low) WE# Setup Time WE# Hold Time CE# Pulse Width CE# Pulse Width High Write Buffer Program Operation (Notes 2, 3) Effective Write Buffer Program Operation (Notes 2, 4) tWHWH1 tWHWH1 Accelerated Effective Write Buffer Program Operation (Notes 2, 4) Single Word Program Operation (Note 2, 5) Accelerated Single Word Programming Operation (Note 2, 5) tWHWH2 tWHWH2 tPOLL Sector Erase Operation (Note 2) Program Valid before Status Polling (Note 7) Per Byte Per Word Per Byte Per Word Min Min Min Min Min Min Min Min Min Min Typ Typ Typ Typ Typ Typ Typ Typ Max 93R 90 Speed Options 103, 103R 113, 113R 123, 123R 100 0 45 45 0 0 0 0 45 30 240 7.5 15 6.25 12.5 60 54 0.5 4 110 120 Unit ns ns ns ns ns ns ns ns ns ns µs µs µs µs µs µs µs sec µs
Notes: 1. Not 100% tested. 2. See “Erase And Programming Performance” on page 60 for more information. 3. For 1–16 words/1–32 bytes programmed. 4. Effective write buffer specification is based upon a 16-word/32-byte write buffer operation. 5. Word programming specification is based upon a single word programming operation not utilizing the write buffer. 6. AC Specifications listed are tested with VIO = VCC. Contact AMD for information on AC operation with VIO ≠ VCC. 7. When using the program suspend/resume feature, if the suspend command is issued within tPOLL, tPOLL must be fully re-applied upon resuming the programming operation. If the suspend command is issued after tPOLL, tPOLL is not required again prior to reading the status bits upon resuming.
58
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
AC CHARACTERISTICS
555 for program 2AA for erase PA for program SA for sector erase 555 for chip erase
Data# Polling PA
Addresses tWC tWH WE# tGHEL OE# tCP CE# tWS tCPH tDS tDH Data tRH
A0A0 for program PD for program 5555 for erase 3030 for sector erase 1010 for chip erase
tAS tAH
tPOLL
tWHWH1 or 2
tBUSY
DQ7#, DQ15
DOUT
RESET#
RY/BY#
Notes: 1. Figure indicates last two bus cycles of a program or erase operation. 2. PA = program address, SA = sector address, PD = program data. 3. DQ7# is the complement of the data written to the device. DOUT is the data written to the device. 4. Waveforms are for the word mode.
Figure 26.
Alternate CE# Controlled Write (Erase/Program) Operation Timings
LATCHUP CHARACTERISTICS
Description Input voltage with respect to VSS on all pins except I/O pins (including A9, OE#, and RESET#) Input voltage with respect to VSS on all I/O pins VCC Current Min –1.0 V –1.0 V –100 mA Max 12.5 V VCC + 1.0 V +100 mA
Note: Includes all pins except VCC. Test conditions: VCC = 3.0 V, one pin at a time.
January 31, 2007 25270C7
Am29LV128MH/L
59
DATA
SHEET
ERASE AND PROGRAMMING PERFORMANCE
Parameter Sector Erase Time Chip Erase Time Single Word Program Time (Note 3) Accelerated Single Word Program Time (Note 3) Total Write Buffer Program Time (Note 4) Effective Write Buffer Program Time (Note 5) Per Byte Per Word Typ (Note 1) 0.5 128 60 54 240 7.5 15 200 6.25 12.5 126 Max (Note 2) 3.5 256 600 540 1200 38 75 1040 33 65 292 Unit sec sec µs µs µs µs µs µs µs µs sec Excludes system level overhead (Note 8) Comments Excludes 00h programming prior to erasure (Note 6)
Total Accelerated Write Buffer Program Time (Note 4) Effective Accelerated Write Buffer Program Time (Note 5) Chip Program Time Per Byte Per Word
Notes: 1. Typical program and erase times assume the following conditions: 25°C, 3.0 V VCC. Programming specifications assume that all bits are programmed to 00h. 2. Maximum values are measured at VCC = 3.0, worst case temperature. Maximum values are valid up to and including 100,000 program/erase cycles. 3. Word programming specification is based upon a single word programming operation not utilizing the write buffer. 4. For 1-16 words or 1-32 bytes programmed in a single write buffer programming operation. 5. Effective write buffer specification is based upon a 16-word/32-byte write buffer operation. 6. The typical chip programming time is considerably less than the maximum chip programming time listed, since most words program faster than the maximum program times listed. 7. In the pre-programming step of the Embedded Erase algorithm, all bits are programmed to 00h before erasure. 8. System-level overhead is the time required to execute the two- or four-bus-cycle sequence for the program command. See Table 11 for further information on command definitions. 9. The device has a minimum erase and program cycle endurance of 100,000 cycles.
60
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
TSOP PIN AND BGA PACKAGE CAPACITANCE
Parameter Symbol CIN Parameter Description Input Capacitance Test Setup TSOP VIN = 0 BGA TSOP COUT Output Capacitance VOUT = 0 BGA TSOP CIN2 Control Pin Capacitance VIN = 0 BGA Typ 6 4.2 8.5 5.4 7.5 3.9 Max 7.5 5 12 6.5 9 4.7 Unit pF pF pF pF pF pF
Notes: 1. Sampled, not 100% tested. 2. Test conditions TA = 25°C, f = 1.0 MHz.
DATA RETENTION
Parameter Description Minimum Pattern Data Retention Time Test Conditions 150°C 125°C Min 10 20 Unit Years Years
January 31, 2007 25270C7
Am29LV128MH/L
61
DATA
SHEET
PHYSICAL DIMENSIONS TS056/TSR056—56-Pin Standard/Reverse Thin Small Outline Package (TSOP)
PACKAGE JEDEC SYMBOL A A1 A2 b1 b c1 c D D1 E e L
O
TS/TSR 56 MO-142 (B) EC MIN. --0.05 0.95 0.17 0.17 0.10 0.10 19.90 18.30 13.90 0.50 0˚ 0.08 NOM. ----1.00 0.20 0.22 ----20.00 18.40 14.00 0.50 BASIC 0.60 3˚ --56 0.70 5˚ 0.20 MAX. 1.20 0.15 1.05 0.23 0.27 0.16 0.21 20.20 18.50 14.10
NOTES: 1 2 3 4 CONTROLLING DIMENSIONS ARE IN MILLIMETERS (mm). (DIMENSIONING AND TOLERANCING CONFORMS TO ANSI Y14.5M-1982.) PIN 1 IDENTIFIER FOR STANDARD PIN OUT (DIE UP). PIN 1 IDENTIFIER FOR REVERSE PIN OUT (DIE DOWN), INK OR LASER MARK. TO BE DETERMINED AT THE SEATING PLANE -C- . THE SEATING PLANE IS DEFINED AS THE PLANE OF CONTACT THAT IS MADE WHEN THE PACKAGE LEADS ARE ALLOWED TO REST FREELY ON A FLAT HORIZONTAL SURFACE. DIMENSIONS D1 AND E DO NOT INCLUDE MOLD PROTRUSION. ALLOWABLE MOLD PROTUSION IS 0.15 mm PER SIDE. DIMENSION b DOES NOT INCLUDE DAMBAR PROTUSION. ALLOWABLE DAMBAR PROTUSION SHALL BE 0.08 mm TOTAL IN EXCESS OF b DIMENSION AT MAX MATERIAL CONDITION. MINIMUM SPACE BETWEEN PROTRUSION AND AN ADJACENT LEAD TO BE 0.07 mm. THESE DIMESIONS APPLY TO THE FLAT SECTION OF THE LEAD BETWEEN 0.10 mm AND 0.25 mm FROM THE LEAD TIP. LEAD COPLANARITY SHALL BE WITHIN 0.10 mm AS MEASURED FROM THE SEATING PLANE. DIMENSION "e" IS MEASURED AT THE CENTERLINE OF THE LEADS.
3160\38.10A
5 6
7 8. 9
R N
62
Am29LV128MH/L
25270C7 January 31, 2007
DATA
SHEET
PHYSICAL DIMENSIONS LAA064—64-Ball Fortified Ball Grid Array 13 x 11 mm Package
January 31, 2007 25270C7
Am29LV128MH/L
63
DATA
SHEET
REVISION SUMMARY Revision A (October 3, 2001)
Initial release as abbreviated Advance Information data sheet.
Product Selector Guide Removed the 98R, 108, 108R, 118, 118R, 128, and 128R Speed Options. Replaced Note #2. Product Selector Guide and Read Only Operations
Revision A+1 (March 20, 2002)
Distinctive Characteristics Clarified description of Enhanced VersatileIO control. Ordering Information Corrected device density in device number/description. Physical Dimensions Added drawing that shows both TS056 and TSR056 specifications.
Added a 30 ns Page Access time and Output Enable Access time to the 113R and 123R Speed Options. Ordering Information Modified Order numbers and package markings to reflect the removal of speed options. Modified the VIO ranges. Added Notes #1 and #2. Table 4. Secured Silicon Sector Contents Added x8 and x16 Operating Ranges Changed the VIO supply range to 1.65–3.6 V. Added VIO (regulated voltage range) and VIO (full voltage range). DC Characteristics Removed VIL, VIH, VOL, and VOH from table and added V IL1 , V IH1 , V IL2 , V IH2 , VOL , VOH1 , and VOH2 f rom the CMOS table in the Am29LV640MH/L datasheet. Erase and Programming Performance Changed the typicals and/or maximums of Chip Erase Time, Sector Erase Time, Effective Write Buffer Program Time, Program Time, and Accelerated Program Time to TBD. Customer Lockable: Secured Silicon Sector NOT Programmed or Protected at the factory. Added second bullet, Secured Silicon sector-protect verify text and figure 3. Secured Silicon Sector Flash Memory Region, and Enter Secured Silicon Sector/Exit Secured Silicon Sector Command Sequence Noted that the ACC function and unlock bypass modes are not available when the Secured Silicon sector is enabled. Byte/Word Program Command Sequence, Sector Erase Command Sequence, and Chip Erase Command Sequence Noted that the Secured Silicon Sector, autoselect, and CFI functions are unavailable when a program or erase operation is in progress.
Revision B (July 1, 2002)
Expanded data sheet to full specification version.
Revision B+1 (September 16, 2002)
Distinctive Characteristics, Physical Dimensions Added 80-Ball Fine-Pitch BGA. Product Selector Guide Added 80-Ball Fine-Pitch BGA. Added Note #1. Added 103, 108, 113, 118, 123, 128 regulated OPNs. Changed all OPNs that end with 4 or 9 to 3 or 8. Program Suspend/Program Resume Command Sequence Changed 1ms to 15μs maximum, with a typical of 5 μs. Erase Suspend/Erase Resume Commands Added that the device requires a typical of 5 μs. Read-Only Operations, Erase Program Operations, and Alternate CE# Controlled Erase and Program Operations Added regulated OPNs. Changed all OPNs that end with 4 or 9 to 3 or 8.
Revision B+2 (November 11, 2002)
Global Removed the Enhanced VI/O option and changed it to VI/O only. Distinctive Characteristics Changed the typical sector erase time to TBD. Changed the typical write buffer word programming time to TBD.
64
Am29LV128MH/L
25270C7 January 31, 2007
DATA Common Flash Memory Interface (CFI) Changed wording in last sentence of third paragraph from, “...the autoselect mode.” to “...reading array data.” Changed CFI website address
SHEET Input values in the tWHWH1 and tWHWH2 parameters in the Alternate CE# Controlled Erase and Program Options table that were previously TBD. Also added Note 5. Erase and Programming Performance Input values into table that were previously TBD. Added note 4.
Revision B+3 (December 2, 2002)
Global Added sector group protection throughout datasheet and added Table 4. Product Selector Guide Added VIOs to table and removed Note #2 Ordering Information Corrected typos in VIO ranges. Removed Notes #1 and 2. Figure 6. Program Suspend/Program Resume Change wait time to 15 μs. Operating Ranges Corrected typos in VIO ranges. Removed full voltage range. DC Characteristics Changed V IH1 a nd V IH2 m inimum to 1.9. Removed typos in notes. Read-Only Characteristics Added a 30 ns option to tPACC and tOE standard in table. Added note #3. Hardware Reset, Erase and Program Operations, Temporary Sector Unprotect, and Alternate CE# Controlled Erase and Program Operations Added Note.
Revision C (May 16, 2003)
Global Converted to full data sheet version. Modified Secured Silicon Sector Flash Memory Region section to include ESN references. Changed data sheet title to Am29LV128MH/L. Erase and Programming Performance Input values into table that were previously TBD. Modified notes.
Revision C+1 (June 11, 2003)
Product Selector Guide Added Note 2 to 113 and 123 speed grades Ordering Information Modified speed grade options available, changed speed grades mentioned in Note. AC Characteristics, Erase and Program Operations and Alternate CE# Controlled Erase and Program Operations Changed tWHWH1 A ccelerated Effective Write Buffer Program Operations value
Revision C+2 (September 9, 2003)
Global Added 90 ns speed options and Ordering Part Numbers Ordering Information Added Note regarding Ordering Part Numbers. Program Suspend/Program Resume Command Sequence Modified last paragraph. Command Definitions, Table 10 Modified First Addr for Program/Erase Suspend and Resume. AC Characteristics Added TRB, TBUSY specs.
Revision B+4 (February 14, 2003)
Distinctive Characteristics Corrected performance characteristics. Product Selector Guide Removed 93R speed option. Added Note 2. Ordering Information Corrected Valid Combination to reflect speed option changes. Added Note. AC Characteristics Removed 93, 93R speed option. Added Note. Input values in the tWHWH1 and tWHWH2 parameters in the Erase and Program Options table that were previously TBD. Also added notes 5 and 6.
January 31, 2007 25270C7
Am29LV128MH/L
65
DATA
SHEET Added notation referencing superceding documentation.
Revision C+3 (February 27, 2004)
Global Changed Datasheet to Advanced Information. Table 1, Device Bus Operations Modified ACC column to replace instances of X to L/H. Customer Lockable: Secured Silicon Sector NOT Programmed or Protected at the Factory Removed second paragraph. Enter Secured Silicon Sector/Exit Secured Silicon Sector Command Sequence Added (write buffer) to last sentence of first paragraph. Write Buffer Programming Removed last paragraph. Table 10 & Table 11, Command Definitions Replaced the Addr information for both Program/Erase Suspend and Program/Erase Resume from BA to XXX. Erase Suspend/Erase Resume Commands Added note on flash device performance during suspend/erase mode. AC Characteristics - Erase and Program Operations Added tPOLL information.
Revision C+4 (October 26, 2004)
Added Pb free options to the ordering information and valid combinations table.
Revision C+5 (January 11, 2005)
Changed notation referencing superceding documentation.
Revision C+6 (October 28, 2005)
This product has been retired and is not recommended for designs. For new and current designs, S29GL256N supersedes Am29LV128MH/L and is the factory-recommended migration path. Please refer to the S29GL256N datasheet for specifications and ordering information. Availability of this document is retained for reference and historical purposes only.
Revision C7 (January 31, 2007)
Global Removed Preliminary designation from document. Changed SecSi Sector to Secured Silicon Sector. Erase and Program Operations table Changed tBUSY to a maximum specification.
Colophon The products described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion LLC will not be liable to you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country, the prior authorization by the respective government entity will be required for export of those products. Trademarks Copyright © 2001–2005 Advanced Micro Devices, Inc. All rights reserved. AMD, the AMD logo, and combinations thereof are registered trademarks of Advanced Micro Devices, Inc. ExpressFlash is a trademark of Advanced Micro Devices, Inc. Product names used in this publication are for identification purposes only and may be trademarks of their respective companies. Copyright © 2005–2007 Spansion Inc. All Rights Reserved. Spansion, the Spansion logo, MirrorBit, ORNAND, HD-SIM, and combinations thereof are trademarks of Spansion Inc. Other names are for informational purposes only and may be trademarks of their respective owners.
66
Am29LV128MH/L
25270C7 January 31, 2007