AEV150 Series DC
Contactor Specification
150AMPS/900VDC
Application
AEV150 series DC contactors are used for battery power supply, DC power control,
circuit protection and other electric vehicle power switch controls. Can also be used in
uninterruptible power supply and other electronic control systems.
Features
HIGH CURRENT AND HIGH VOLTAGE
Nitrogen sealed contacts to minimize arcing.
COMPACT STRUCTURE, LOW NOISE
Contact design yields reduced unit size, low noise while carrying or switching currents.
COIL ECONOMIZER
Built-in coil economizer – only 1.7W holding power @12VDC, limits back EMF to 0V.
HIGH SAFETY
There is no arc leakage due to tight sealing.
HIGH CONTACT RELIABILITY
Stable contact resistance no matter how harsh the environment with sealed contacts.
NO SPECIAL MOUNTING REQUIREMENT
Light weight actuator is less impacted by gravity with no special mounting orientation requirements.
VARIOUS APPLICATIONS
Application includes battery switch and standby equipment, DC power control, circuit protection, etc.
OPTIONAL AUXILIARY CONTACT
Allows for contact position signal.
EU ROHS DIRECTIVE (2011/65/EU) COMPLIANT
Nomenclauture
Example
AEV150 —
M
AN
Series code:
“AEV150” = AEV150 Series
Coil Voltage Code:
“M” = 12 - 24 VDC
Options (applied in this order):
Blank = Std. Options (Bottom Mount, Without Aux.
Contact & Polarized Load Terminals)
“A” = With Aux. Contact (SPST-NO)
“N” = Non-Polar Load Terminals
1
AEV150 Series DC
Contactor Specification
150AMPS/900VDC
Performance Data
MAIN CONTACT
LIFE
Contact arrangement
1 Form X (SPST-NO DM)
Resistive load life
See chart below
Rated Operating Voltage
12-900VDC
Mechanical life
200,000 cycles
Continuous (Carry) Current
150A -200A (65 ˚C)
AUX. CONTACT
Make/Break current
See chart below
Aux. Contact arrangement
1 Form A
Max short circuit current
2,000A @320VDC, 1 cycle *1
Aux. Contact Current Max
2A@30VDC/
3A@125VAC
Dielectric
Withstanding Voltage
Insulation Resistance*2
Between open
contacts: 2,200Vrms, ≤1mA
Aux. Contact Current Min
100mA@8V
Between contact
and coil: 2,200 Vrms, ≤1mA
Max Contact Resistance
0.417ohms@30VDC/
0.150ohms @125VAC
Terminal to Terminal/
Terminal to coil
New: Min 100 MΩ @500Vdc
End of life: Min 50 MΩ @500Vdc
Voltage Drop (@150A)
≤60mV
ENVIRONMENTAL DATA
OPERATE / RELEASE TIME
Shock, 11ms ½ sine, operating
20G Peak
Close (includes bounce)
25ms, Max.
Vibration, Sine, Peak, 20G
80—2,000Hz
Bounce (after close only)
7ms, Max.
Operating
Ambient Temperature
-40 to +85 ˚C
Release (@2000A includes arc)
12ms, Max.
Altitude
1ms) then a surge current protection device should be connected in parallel to the
inductive load.
8.
Drive power must be greater than coil power or it will reduce performance capability.
9.
Avoid debris or oil contamination of the main terminals to optimize contact and avoid excess heat generation.
10. Unit operates after power applied for 0.1s, do not rapidily switch unit.