0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AEV150-MAN

AEV150-MAN

  • 厂商:

    AMI

  • 封装:

  • 描述:

    AEV150 SERIES 150A DC CONTACTOR

  • 数据手册
  • 价格&库存
AEV150-MAN 数据手册
AEV150 Series DC Contactor Specification 150AMPS/900VDC Application AEV150 series DC contactors are used for battery power supply, DC power control, circuit protection and other electric vehicle power switch controls. Can also be used in uninterruptible power supply and other electronic control systems. Features HIGH CURRENT AND HIGH VOLTAGE Nitrogen sealed contacts to minimize arcing. COMPACT STRUCTURE, LOW NOISE Contact design yields reduced unit size, low noise while carrying or switching currents. COIL ECONOMIZER Built-in coil economizer – only 1.7W holding power @12VDC, limits back EMF to 0V. HIGH SAFETY There is no arc leakage due to tight sealing. HIGH CONTACT RELIABILITY Stable contact resistance no matter how harsh the environment with sealed contacts. NO SPECIAL MOUNTING REQUIREMENT Light weight actuator is less impacted by gravity with no special mounting orientation requirements. VARIOUS APPLICATIONS Application includes battery switch and standby equipment, DC power control, circuit protection, etc. OPTIONAL AUXILIARY CONTACT Allows for contact position signal. EU ROHS DIRECTIVE (2011/65/EU) COMPLIANT Nomenclauture Example AEV150 — M AN Series code: “AEV150” = AEV150 Series Coil Voltage Code: “M” = 12 - 24 VDC Options (applied in this order): Blank = Std. Options (Bottom Mount, Without Aux. Contact & Polarized Load Terminals) “A” = With Aux. Contact (SPST-NO) “N” = Non-Polar Load Terminals 1 AEV150 Series DC Contactor Specification 150AMPS/900VDC Performance Data MAIN CONTACT LIFE Contact arrangement 1 Form X (SPST-NO DM) Resistive load life See chart below Rated Operating Voltage 12-900VDC Mechanical life 200,000 cycles Continuous (Carry) Current 150A -200A (65 ˚C) AUX. CONTACT Make/Break current See chart below Aux. Contact arrangement 1 Form A Max short circuit current 2,000A @320VDC, 1 cycle *1 Aux. Contact Current Max 2A@30VDC/ 3A@125VAC Dielectric Withstanding Voltage Insulation Resistance*2 Between open contacts: 2,200Vrms, ≤1mA Aux. Contact Current Min 100mA@8V Between contact and coil: 2,200 Vrms, ≤1mA Max Contact Resistance 0.417ohms@30VDC/ 0.150ohms @125VAC Terminal to Terminal/ Terminal to coil New: Min 100 MΩ @500Vdc End of life: Min 50 MΩ @500Vdc Voltage Drop (@150A) ≤60mV ENVIRONMENTAL DATA OPERATE / RELEASE TIME Shock, 11ms ½ sine, operating 20G Peak Close (includes bounce) 25ms, Max. Vibration, Sine, Peak, 20G 80—2,000Hz Bounce (after close only) 7ms, Max. Operating Ambient Temperature -40 to +85 ˚C Release (@2000A includes arc) 12ms, Max. Altitude 1ms) then a surge current protection device should be connected in parallel to the inductive load. 8. Drive power must be greater than coil power or it will reduce performance capability. 9. Avoid debris or oil contamination of the main terminals to optimize contact and avoid excess heat generation. 10. Unit operates after power applied for 0.1s, do not rapidily switch unit. 1741 Industrial Drive, No. 14 • Sterling, IL 61081 Tel: 815-632-3150 • Fax: 815-632-3449 www.altranmagnetics.com • sales@altranmagnetics.com 5
AEV150-MAN 价格&库存

很抱歉,暂时无法提供与“AEV150-MAN”相匹配的价格&库存,您可以联系我们找货

免费人工找货