Solid State Relay
SH Series Single Phase AC Output
•
•
•
•
•
•
Zero-crossing or Random-on Switching
Rated Load Current: 25A @ 24-660VAC
DC Input
SCR Output
Built-in RC Snubber Circuit and TVS Optional
RoHS Compliant
Product Description
ASR-SH series industrial single phase relay with SCR output is widely used in industry applications, PCB mounted.
The relay can be used for resistive, inductive or capacitive load. The control voltage is 4-32VDC, the load voltage is
240VAC, 480VAC, or 600VAC, output current is rated at 25A.
Product Selection
ASR
—
SH
240
D
25
R
W
Packing:
- : Bulk
Packing
A-Z
SH Series
Load Voltage
240:240VAC
380:380VAC
480:480VAC
600:600VAC
Control
Voltage Type
D:DC Control
A: AC Control
Load Current
10:10Amps
25:25Amps
Switching
Mode
Z:Zero
Crossing
R:Random-on
Control
Voltage
4-32VDC
NOTE: Alternate control voltages: 18-36VAC, 4-15VDC, 15-32VDC are available as well as options for RC circuit and TVS. Consult
with engineering to determine which combinations are available.
INPUT CIRCUIT
Control Voltage Range
W
4-32VDC
Must Turn-on Voltage
4VDC
Must Turn-off Voltage
5/12/24
1.0VDC
Maximum Input Current
Random-on
25mA@32VDC
Zero Crossing
18mA@32VDC
1
Solid State Relay
SH Series Single Phase AC Output
OUTPUT CIRCUIT
Load Voltage Range
240VAC
24~280VAC
380VAC
24~440VAC
480VAC
24~530VAC
600VAC
24~660VAC
Maximum Turn-on Time
Random-On
1ms
Zero Crossing
10ms
Maximum Turn-off Time
10ms
Maximum Surge
250A
Current [@10 ms]
Transient Overvoltage
240VAC
600Vpk
380VAC
800Vpk
480VAC/600VAC
1200Vpk
Maximum Off-state Leakage
Current [@ Rated Voltage]
With RC
5mA
Maximum On-state Voltage
Drop [@ Rated Current]
1.5Vrms
Minimum Off-state dv/dt
[@ Maximum Rated Voltage]
500V/μs
GENERAL INFORMATION
Dielectric Strength, [50/60Hz]
Input/Output
4000Vrms
Input,Output/Base 2500Vrms
Power Factor
>0.5
Ambient Operating
Temperature Range
-30˚C +100˚C
Ambient Stotage
Temperature Range
-30˚C +100˚C
Weight [Typical]
50g
2
Solid State Relay
SH Series Single Phase AC Output
Application Note:
Wiring Diagram
Lighting control, Medical equipment, Elevator, Electric control door.
Thermal Curve
Important Notice
1. Soldering must be finished within 10 seconds at 260˚C,or finished within 5 seconds at 350˚C. Otherwise it may
cause damage to the relay.
2. Terminal polarity must be observed. Otherwise it may cause damage to the relay.
3. When ambient temperature is above 25˚C, the maximum load current decreases. See thermal derating curve.
Product Certification
1741 Industrial Drive, No. 14 • Sterling, IL 61081
Tel: 815-632-3150 • Fax: 815-632-3449