Solid State Relay
SMA Series Single Phase AC Output
•
•
•
•
•
•
•
ASR
Optoelectronic Isolation
TRIAC Output
Load Voltage:240VAC
Load Current:1A,2A
Dielectric Strength 2500VACrms
PCB Mounted
RoHS Compliant
—
SM
A
Packing
- : Bulk pack
A-Z
SM Series
Load Type
A:AC Load
240
D
Load Voltage DC Control
240:240VAC
1
R
N
-K
Load
Current
1: 1Amp
2: 2Amp
Switching
Mode
Z:Zero
Crossing
R:Random-on
Control
Voltage
N: 5VDC
P: 12VDC
R: 24VDC
S: 48VDC
T: 60VDC
None:
No Socket
K: with
Socket
Technical Specification
INPUT CIRCUIT(TA=25˚C)
Control Voltage Range
N
4-6VDC
P
9.6-14.4VDC
R
19.2-28.8VDC
S
38.4-57.6VDC
T
48-72VDC
Must Turn-on Voltage (1) N
4VDC
P
9.6VDC
R
19.2VDC
S
38.4VDC
T
48VDC
Must Turn-off Voltage
1VDC
Maximum Input Current
25mA
1
Solid State Relay
SMA Series Single Phase AC Output
OUTPUT CIRCUIT(TA=25˚C)
Load Voltage Range (47Hz-63Hz)
24-280VAC
Maximum Transient Overvoltage
600Vpk
Load Current Range
1A
0.1 - 1A
2A
0.1 - 2A
Maximum Turn-On Time
Random-on
1ms
Zero Crossing
10ms
Maximum Turn-Off Time
300μs
Maximum Surge Current [@10 ms]
1A
30A
2A
40A
Maximum Off-State Leakage
Current [@ Rated Voltage]
1.5mA
Maximum On-State Voltage
Drop [@ Rated Current]
1.5Vrms
Maximum On-State Voltage
Drop [@ Rated Current]
200V/μs
GENERAL INFORMATION (TA=25˚C)
Dielectric Strength, Input/Output(50/60Hz)
2500Vrms
Insulation Resistance(@500VDC)
1000MΩ
Ambient Operating Temperature Range
-30˚C +80˚C
Ambient Storage Temperature Range
-30˚C +100˚C
Weight (Typical)
ASR-SM240...-…Series
4g
ASR-SM240...-…K Series
30g
2
Solid State Relay
Installation
SSR
(1.10)
(1.10)
(0.20)
(0.20)
(0.02)
(0.02)
(0.07)
(0.07)
(0.64)
(0.64)
(0.20)
(0.24)
(0.04)
(0.04)
(0.02)
(0.15)
(3.19)
SMA Series Single Phase AC Output
(0.05)
(1.36)
(0.20)
(3.80)
With Socket
Wiring Diagram
ASR-SMD…D...-NK Series
ASR-SMD...D...-P/R/S/TK Series
3
Solid State Relay
SMA Series Single Phase AC Output
Attentions:
1. Soldering must be finished within 10 seconds at 260˚C,or finished within 5 seconds at 350˚C. Otherwise it may
cause damage to the relay.
2. When connecting wiring to SSR please ensure screws are torqued down properly 4.43 in-lb, 0.5 N·m3.
3. When ambient temperature is above 25˚C or tight installation required, the maximum load current decreases.
See thermal derating curve.
2. Terminal polarity must be observed. Otherwise it may cause damage to the relay.
Product Certification
1741 Industrial Drive, No. 14 • Sterling, IL 61081
Tel: 815-632-3150 • Fax: 815-632-3449
www.altranmagnetics.com • sales@altranmagnetics.com
3