Amphenol®
Assembly Instructions-C26b
BNC
ORIGINAL CRIMP PLUGS
BOOT
boot
ferrule
G O
ferrule clamp
nut assembly
SS
plug body assembly
Hex Crimp Data
Amphenol
Number
Connector
Type
31-351
BNC Plug
58, 141
31-359
BNC Plug
59, 62, 140
31-371
BNC Plug
174, 179, 187, 188, 316
Step 1
FERRULE/
CLAMP NUT ASSY
OUTER FERRULE
Cable
RG-/U
Cavity for
Contact
Stripping Dimensions, inches (mm)
Cavity for
Outer Ferrule
Die Set for
Tool 227-944*
a
b
c
—
.213(5.4)
227-1221-11
.922(23.4)
.516(13.1)
.250(6.3)
—
.255(6.5)
227-1221-13
.922(23.4)
.516(13.1)
.250(6.3)
—
.128(3.2)
227-1221-3
.797(20.2)
.516(13.1)
.250(6.3)
boot
Step 1 Install boot and slide outer ferrule onto cable as shown prior
to stripping cable.
outer ferrule
STEP 1
a
Step 2
b
STEP 2
c
Step 2 Strip cable jacket, braid and dielectric to dimensions shown.
See attached table for dimensions. All cuts are to be sharp
and square. Important: DO NOT nick braid, dielectric, and
center conductor when cutting. Tin center conductor using
soft solder per QQ-S-571 comp Sn 60. Avoid excessive heat
while tinning to prevent swelling of cable dielectric.
Step 3
Step 3 Slightly flare out end of cable braid as so as to facilitate
insertion onto ferrule clamp nut assembly. Important:
DO NOT comb out braid.
P3
Step 4
STEP 4
Step 5
outer ferrule must
clamp nut assy
as shown
cable dielectric must
butt insulator as shown
note: center conductor must
be visible thru contact solder
hole prior to soldering
Step 4 Install ferrule clamp nut assembly onto cable so that ferrule
portion slides under braid and insulator butts flush against
cable dielectric. Slide outer ferrule over braid and up
against nut. Make sure no slack exists in braid. Crimp outer
ferrule with tool specified in table above, keeping cable
dielectric bottomed against insulator.
STEP 5
Step 5 Soft solder center conductor to contact using rosin core per
QQ-S-571 comp Sn 60. DO NOT get any solder on outside
surfaces of contact.
Step 6
STEP 6
Step 7
lip of boot must be firmly positioned in body groove
Step 6 Screw connector body onto prepared cable termination .
Wrench tighten by holding the cable nut assembly
STATIONARY while ROTATING the connector body.
STEP 7
Step 7 Push body forward and into position as shown to complete
assembly.
* for pneumatic crimp tool 227-60, use die sets indicated in this column
Amphenol Corporation Tel: 800-627-7100