MS/Standard
solder contacts
Machined copper alloy contacts in a full range of sizes, with closed
entry socket design in the size 12 and 16 contacts. A heavy silverplated finish is deposited on all MS style solder contacts for maximum
corrosion resistance, maximum current carrying capacity and low millivolt drop.
MS/STANDARD SOLDER CONTACTS*
Part
Number
Pin/
Socket
10-40569
Pin
10-597107-161
Socket
10-40599
Pin
10-597107-171
Socket
Mating
End
Size
Wire
Barrel
Size
16
Short†
16
16 Long
10-33646
Pin
10-597107-131
Socket
10-35531
Pin
10-35532
Socket
10-35529
Pin
Socket
10-35527
Pin
10-35528
Test
Current**
Amps
13
10
7.5
5
16
18
20
22
12
14
23
17
8
8
8
10
46
33
4
4
4
6
80
60
0
0
0
1
2
150
125
100
Socket
Recommended
Operating Voltage*
at Sea Level
DC
AC (RMS)
Effective
Creepage
Distance
Nom.
Inst.
250
200
1/16
A
700
500
1/8
1/16
D
1250
900
3/16
1/8
E
1750
1250
1/4
3/16
B
2450
1750
5/16
1/4
C
4200
3000
1
5/16
MS
Service
Rating
13
10
7.5
5
16
18
20
22
12
12
10-35530
16
Allowable
Wire
Size
TABLE I
CONTACT ARRANGEMENT SERVICE RATING
Mechanical
Spacing
Nom.
* The values listed in Table I represent operating values which include a
generous safety factor. It may be necessary for some applica ions to
exceed the operating voltages listed here. If this is necessary, designers
will find Table II useful for determining the degree to which the recommended values of Table I can be exceeded.
* Solder Wells Filled
** Contact ratings as stated are test ra ings only. The connector could not withstand full rated current through all contacts continuously. Please note that the
electrical data given is not an establishment of electrical safety factors. This is
left entirely in the designer’s hands as he can best determine which peak voltage, switching surges, transients, etc. can be expected in a par icular circuit.
† The 10SL, 12S, 14S and 16S connectors require short contacts.
TABLE II
ALTITUDE VOLTAGE DERATING** CHART
Nominal
Distance
MS
Service
Rating
Airspace
Standard Sea
Level Conditions
Creepage
Pressure Altitude†
50,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Pressure Altitude†
70,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Inst.
1/32
1/16
1400
1000
500
400
325
260
A
1/16
1/8
2800
2000
800
600
450
360
D
1/8
3/16
3600
2800
900
675
500
400
E
3/16
1/4
4500
3500
1000
750
550
440
B
1/4
5/16
5700
4500
1100
825
600
480
C
5/16
1
8500
7000
1300
975
700
560
† Not corrected for changes in density due to variations in temperature.
** No attempt has been made to recommend operating voltages. The designer must determine his own
operating voltage by the application of a safety factor to the above derating chart to compensate for circuit transients, surges, etc.
67
MS/Standard
crimp contacts
Machined from copper alloy and silver-plated for maximum corrosion resistance, with a
minimum millivolt drop and a maximum current carrying capacity, the size 16 and 12
socket contacts are of the closed entry design. Crimp contacts are available for all MS
insert arrangements and are identified with an Amphenol® proprietary number.
MS/STANDARD CRIMP CONTACTS
Part
Number
10-40553
Pin/
Socket
Pin
10-40552 or
10-597109-161 Socket
10-40557
16
Short†
16
Pin
10-40556 or
10-597109-171 Socket
10-40561
Mating Wire
End
Barrel
Size
Size
16
Long
16
Pin
10-40560 or
10-597109-131 Socket
Allowable
Wire
Size
16
18
20
22*
16
18
20
22*
Required
Test
Wire Adapter Current**
Sleeve
Amps
10-74696-6
10-74696-6
12
12
13
10
7.5
5
13
10
7.5
5
23
12
14
Pin
Socket
8
8
8
10*
10-74696-1
46
33
10-40564
10-40565
Pin
Socket
4
4
4
6*
10-74696-2
80
60
10-40562 or
10-581806
10-40563 or
10-581808
Pin
0
0
0
Socket
2*
Recommended
Operating Voltage*
at Sea Level
DC
AC (RMS)
Effective
Creepage
Distance
Nom.
Inst.
250
200
1/16
A
700
500
1/8
1/16
D
1250
900
3/16
1/8
E
1750
1250
1/4
3/16
B
2450
1750
5/16
1/4
C
4200
3000
1
5/16
MS
Service
Rating
Mechanical
Spacing
Nom.
* The values listed in Table I represent operating values which include a
generous safety factor. It may be necessary for some applica ions to
exceed the operating voltages listed here. If this is necessary, designers
will find Table II useful for determining the degree to which the recommended values of Table I can be exceeded.
17
10-40792
10-40793
TABLE I
CONTACT ARRANGEMENT SERVICE RATING
150
10-74696-7
100
* When using wire adapter sleeve shown.
** Contact ratings as stated are test ratings only. The connector could not withstand full
rated current through all contacts continuously. Please note that the electrical data
given is not an establishment of electrical safety factors. This is left entirely in the
designer’s hands as he can best determine which peak voltage, switching surges,
transients, etc. can be expected in a particular circuit.
† The 10SL, 12S, 14S and 16S connectors require short contacts.
TABLE II
ALTITUDE VOLTAGE DERATING** CHART
Nominal
Distance
MS
Service
Rating
Airspace
Standard Sea
Level Conditions
Creepage
Pressure Altitude†
50,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Pressure Altitude†
70,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
Inst.
1/32
1/16
1400
1000
500
400
325
260
A
1/16
1/8
2800
2000
800
600
450
360
D
1/8
3/16
3600
2800
900
675
500
400
E
3/16
1/4
4500
3500
1000
750
550
440
B
1/4
5/16
5700
4500
1100
825
600
480
C
5/16
1
8500
7000
1300
975
700
560
† Not corrected for changes in density due to variations in temperature.
** No attempt has been made to recommend operating voltages. The designer
must determine his own operating voltage by the application of a safety factor to
the above derating chart to compensate for circuit transients, surges, etc.
68
很抱歉,暂时无法提供与“10-040565-000”相匹配的价格&库存,您可以联系我们找货
免费人工找货