0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
10-040565-000

10-040565-000

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

    -

  • 描述:

    CONTACTSOCKET4-6AWGCRIMPSLVR

  • 数据手册
  • 价格&库存
10-040565-000 数据手册
MS/Standard solder contacts Machined copper alloy contacts in a full range of sizes, with closed entry socket design in the size 12 and 16 contacts. A heavy silverplated finish is deposited on all MS style solder contacts for maximum corrosion resistance, maximum current carrying capacity and low millivolt drop. MS/STANDARD SOLDER CONTACTS* Part Number Pin/ Socket 10-40569 Pin 10-597107-161 Socket 10-40599 Pin 10-597107-171 Socket Mating End Size Wire Barrel Size 16 Short† 16 16 Long 10-33646 Pin 10-597107-131 Socket 10-35531 Pin 10-35532 Socket 10-35529 Pin Socket 10-35527 Pin 10-35528 Test Current** Amps 13 10 7.5 5 16 18 20 22 12 14 23 17 8 8 8 10 46 33 4 4 4 6 80 60 0 0 0 1 2 150 125 100 Socket Recommended Operating Voltage* at Sea Level DC AC (RMS) Effective Creepage Distance Nom. Inst. 250 200 1/16 A 700 500 1/8 1/16 D 1250 900 3/16 1/8 E 1750 1250 1/4 3/16 B 2450 1750 5/16 1/4 C 4200 3000 1 5/16 MS Service Rating 13 10 7.5 5 16 18 20 22 12 12 10-35530 16 Allowable Wire Size TABLE I CONTACT ARRANGEMENT SERVICE RATING Mechanical Spacing Nom. * The values listed in Table I represent operating values which include a generous safety factor. It may be necessary for some applica ions to exceed the operating voltages listed here. If this is necessary, designers will find Table II useful for determining the degree to which the recommended values of Table I can be exceeded. * Solder Wells Filled ** Contact ratings as stated are test ra ings only. The connector could not withstand full rated current through all contacts continuously. Please note that the electrical data given is not an establishment of electrical safety factors. This is left entirely in the designer’s hands as he can best determine which peak voltage, switching surges, transients, etc. can be expected in a par icular circuit. † The 10SL, 12S, 14S and 16S connectors require short contacts. TABLE II ALTITUDE VOLTAGE DERATING** CHART Nominal Distance MS Service Rating Airspace Standard Sea Level Conditions Creepage Pressure Altitude† 50,000 Feet Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Pressure Altitude† 70,000 Feet Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Inst. 1/32 1/16 1400 1000 500 400 325 260 A 1/16 1/8 2800 2000 800 600 450 360 D 1/8 3/16 3600 2800 900 675 500 400 E 3/16 1/4 4500 3500 1000 750 550 440 B 1/4 5/16 5700 4500 1100 825 600 480 C 5/16 1 8500 7000 1300 975 700 560 † Not corrected for changes in density due to variations in temperature. ** No attempt has been made to recommend operating voltages. The designer must determine his own operating voltage by the application of a safety factor to the above derating chart to compensate for circuit transients, surges, etc. 67 MS/Standard crimp contacts Machined from copper alloy and silver-plated for maximum corrosion resistance, with a minimum millivolt drop and a maximum current carrying capacity, the size 16 and 12 socket contacts are of the closed entry design. Crimp contacts are available for all MS insert arrangements and are identified with an Amphenol® proprietary number. MS/STANDARD CRIMP CONTACTS Part Number 10-40553 Pin/ Socket Pin 10-40552 or 10-597109-161 Socket 10-40557 16 Short† 16 Pin 10-40556 or 10-597109-171 Socket 10-40561 Mating Wire End Barrel Size Size 16 Long 16 Pin 10-40560 or 10-597109-131 Socket Allowable Wire Size 16 18 20 22* 16 18 20 22* Required Test Wire Adapter Current** Sleeve Amps 10-74696-6 10-74696-6 12 12 13 10 7.5 5 13 10 7.5 5 23 12 14 Pin Socket 8 8 8 10* 10-74696-1 46 33 10-40564 10-40565 Pin Socket 4 4 4 6* 10-74696-2 80 60 10-40562 or 10-581806 10-40563 or 10-581808 Pin 0 0 0 Socket 2* Recommended Operating Voltage* at Sea Level DC AC (RMS) Effective Creepage Distance Nom. Inst. 250 200 1/16 A 700 500 1/8 1/16 D 1250 900 3/16 1/8 E 1750 1250 1/4 3/16 B 2450 1750 5/16 1/4 C 4200 3000 1 5/16 MS Service Rating Mechanical Spacing Nom. * The values listed in Table I represent operating values which include a generous safety factor. It may be necessary for some applica ions to exceed the operating voltages listed here. If this is necessary, designers will find Table II useful for determining the degree to which the recommended values of Table I can be exceeded. 17 10-40792 10-40793 TABLE I CONTACT ARRANGEMENT SERVICE RATING 150 10-74696-7 100 * When using wire adapter sleeve shown. ** Contact ratings as stated are test ratings only. The connector could not withstand full rated current through all contacts continuously. Please note that the electrical data given is not an establishment of electrical safety factors. This is left entirely in the designer’s hands as he can best determine which peak voltage, switching surges, transients, etc. can be expected in a particular circuit. † The 10SL, 12S, 14S and 16S connectors require short contacts. TABLE II ALTITUDE VOLTAGE DERATING** CHART Nominal Distance MS Service Rating Airspace Standard Sea Level Conditions Creepage Pressure Altitude† 50,000 Feet Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Pressure Altitude† 70,000 Feet Minimum Flashover Voltage AC (RMS) Test Voltage AC (RMS) Inst. 1/32 1/16 1400 1000 500 400 325 260 A 1/16 1/8 2800 2000 800 600 450 360 D 1/8 3/16 3600 2800 900 675 500 400 E 3/16 1/4 4500 3500 1000 750 550 440 B 1/4 5/16 5700 4500 1100 825 600 480 C 5/16 1 8500 7000 1300 975 700 560 † Not corrected for changes in density due to variations in temperature. ** No attempt has been made to recommend operating voltages. The designer must determine his own operating voltage by the application of a safety factor to the above derating chart to compensate for circuit transients, surges, etc. 68
10-040565-000 价格&库存

很抱歉,暂时无法提供与“10-040565-000”相匹配的价格&库存,您可以联系我们找货

免费人工找货