Amphenol®
Assembly Instructions-C70
MMCX (continued)
STRAIGHT CONNECTORS FOR FLEXIBLE CABLE
a
b
Ferrule
c
Contact
Hex Crimp Data
Amphenol Connector Cable
Number
Type
RG-/U
Connector Body
Stripping Dimensions, inches (mm)
CTL Series
Tool No.
CTL-13
d
e
f
908-41200
Straight Plug
RG-178, 196
.170 (4.32)
.300 (7.62)
.360 (9.14)
908-41300
Straight Plug
RG-174, 188, 316
.128 (3.25)
CTL-13
.170 (4.32)
.325 (7.62)
.365 (8.64)
908-41500
Straight Plug
RD-316
.151 (3.84)
CTL-13
.170 (4.32)
.325 (7.62)
.365 (8.64)
908-42300
Straight Jack
RG-174, 188, 316
.128 (3.25)
CTL-13
.170 (4.32)
.325 (7.62)
.365 (8.64)
908-42500
Straight Jack
RD-316
.151 (3.84)
CTL-13
.170 (4.32)
.325 (7.62)
.365 (8.64)
f
e
Step 1
Prepare cable according to diagram. Do not damage braid
and inner conductor of cable. Slide crimp ferrule “a” over the
braid.
Step 2
Solder contact “b” to the center conductor of the cable.
Contact must butt on the dielectric of the cable as shown.
Step 3
Flare braid and insert contact into body assembly “c”.
Contact must bottom in insulator resulting in a dimension of
.006 ±.007 from the tip of the contact to the end of the body.
Crimp ferrule using the appropriate hex dies.
d
CONTACT MUST BUTT HERE
Amphenol Corporation Tel: 800-627-7100