0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
C11210A05402010

C11210A05402010

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

    -

  • 描述:

    CABLEASSYMALESNGLEND4POS2M

  • 数据手册
  • 价格&库存
C11210A05402010 数据手册
Amphenol Amphenol-Tuchel Electronics GmbH M12 - Connectors C 112 Series We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our line of high quality, peak performance products are achieved through the implementation of modern manufacturing methods utilizing the latest technologies. Local markets are served through an extensive global network of distributors and manufacturing sites. Amphenol sets the standard of connector technology with an array of patent and innovations. Our vast experience in aerospace, automotive, data transfer, military, and telecommunications enables us to provide solutions to your market challenges. System Description Amphenol’s M12 family of connectors features the C112 series. They are characterized by compact size, functional design, reliable sealing, durable construction and electrically stable. The connector protects the cable and its components from loosening due to harsh vibration while operating in tough industrial environments. Electrically sensitive applications requiring EMI shielding are protected with a design that enables attenuation values in the range of a double shielded cable. This design feature incorporates a 360° shielding system from the cable to the appliance housing. 2 The connectors in the C112 family use a 12 mm thread. These connectors are top choice in automation and sensor technology. Power circuit requirements up to four amps can also be satisfied by this connector design. ntinents Standards EMI Connectors meet these standards: IEC 61076-2-101, interfaces according to (IEC 60947-5-2) and proximity switches (VDE 0660 part 208). German EMI regulations (EMI-guideline: 89/336 EWG) are met when correctly assembled in the appliance. 3 Application and use Assembly Termination 4 Connectors should be used according to their rated performance values. These rated values are etablished under specific conditions to meet product specifications or other electrical qualifications. The C112 connectors are designed for use in a variety of electrical equipment and applications that control various appliances or link communications with sensor technology. The user is responsible to verify that the connector meets the application requirements of the product. All connector rating data in this catalog is based on the overvoltage of category III and pollution degree of 2/3 for electrical devices. All specifications are met when the connectors are completely mated. The housings of the panel receptacle or plug must be reliably integrated into the protective means of the enclosure. Reference: DIN VDE 0100 part 410; 80384-4-41. During assembly, care must be given to ensure that all components are correctly mounted and screw terminations are tightened to the correct torque. Customer assembled cable connectors must follow precise instructions to properly secure the strain relief system. There is an integrated strain relief clamp or a standard Pg cable entry. The standard Pg cable entry requires a strain relief close to the rear of the connector. Cable selection should meet the same specifications as the connector (i.e., solvent resistance or fire protection). Correct polarity must be observed when terminating wires. The wire insulation should be stripped to the proper length and wire diameter. Remarks Safety classification according to DIN VDE 0627 The C112 connectors are designed and produced in conformance with the low voltage guidelines: 72/73 EWG and the law for safety of appliances. The connectors are designed and manufactured according to DIN VDE 57-0627. Design changes to meet quality improvements, product development or production requirements are reserved. All technical data is related to connectors operating under normal use and loads when fully mated. Connectors should not be mated or unmated while under load. Connector safety is dependent Type Feature male cable con. female cable connector with LED, customer ass’y female cable con. upon the correct selection of products, installation, and assembly. The listed technical data and remarks are intended to help the user select the correct products for the appropriate applications. Safety Connector Protective classification1) earth contact A B C free fixed with without Protection Rewireable against 1) D E yes no X X X X X X X X X X X X X X X X X X X X X Cordset X Female panel con. X X X X Male panel con. X X X X Male panel con. customer ass’y X X X X X Distributors 1) X X X X X X X X X X A Connections to and from a device / B Connections within a device / C Free cable connection D Mated / E Unmated 5 Content 6 Male cable connectors / Female cable connectors, overmolded Male cable connector, straight Male cable connector, right angled Female cable connector, straight Female cable connector, right angled Male cable connector, straight, shielded Male cable connector, right angled, shielded Female cable connector, straight, shielded Female cable connector, right angled, shielded Female cable connector, right angled, customer assembly Page Page Page Page Page Page Page Page Page 10 10 11 11 12 12 13 13 14 Male cable connectors / Female cable connectors, customer assembly Male cable connector, straight and right angled Female cable connector, straight and right angled Male cable connector, straight, shielded Female cable connector, straight, shielded Female cable connector, shielded Page Page Page Page Page 16 16 17 17 17 Cordsets, overmolded Male connector, straight / Female connector, straight Male connector, straight / Female connector, right angled Page 22 Page 22 Cordsets, shielded, overmolded Male connector, straight / Female connector, straight Male connector, straight / Female connector, right angled Page 23 Page 23 Male and female panel connectors Male panel connector, front mounting Female panel connector, front mounting Male panel connector, rear mounting Female panel connector, rear mounting Male panel connector, rear mounting, pcb-mount type Female panel connector, rear mounting, pcb-mount type Male panel connector, installation version Page Page Page Page Page Page Page Distributors Y-Distributor Distribution box Page 33 Page 34 27 27 28 28 29 29 29 Male / Female Cable Connectors overmolded C112 series Male cable connector, straight, unshielded anti-vibration coupling nut and overmolded cable ... Page 10 Description Male cable connector, straight, shielded anti-vibration coupling nut and overmolded cable ... Page 12 M12 cables available with male or female connectors, straight or angled housings and cable jacket materials in PVC or PUR. Male cable connector, right angled, unshielded anti-vibration coupling nut and overmolded cable ... Page 10 EMI shielded M12 cables are available with male and female connectors, straight or angled housings and cable jacket materials in PVC or PUR. Male cable connector, right angled, shielded anti-vibration coupling nut and overmolded cable ... Page 12 Female cable connector, straight, unshielded anti-vibration coupling nut and overmolded cable ... Page 11 Female cable connector, straight, shielded anti-vibration coupling nut and overmolded cable ... Page 13 Female cable connector, right angled, unshielded anti-vibration coupling nut and overmolded cable ... Page 11 Female cable connector, right angled, shielded anti-vibration coupling nut and overmolded cable ... Page 13 7 General characteristics Standard Number of contacts Standard Version Shielded Customer Assembly 3/4/5 3/4/5 3 / 3+PE 3) 3) Electrical characteristics Contact resistance IEC 60 512-2, test 2 a ≤ 10 mΩ (without cable) ≤ 10 mΩ Current carrying capacity IEC 60 512-3, test 5 b 4 A at Tu = 40°C without LED 7 A at Tu = 40°C with LED 3,5 A at Tu = 40°C Rated voltage IEC 60 664-12) 3+4 cont. 250 V AC / DC 60 V AC/DC without LED 250 V AC / DC IEC 60 664-12) 5 cont. 60 V AC / DC 60 V AC/DC with LED 36 V DC IEC 60 664-12) 3 + 4 cont. 2,5 kV 0,8 kV without LED 2,5 kV IEC 60 664-12) 5 cont. 1,5 kV 0,8 kV – Insulation resistance IEC 60 512-2, test 3 a > 10 8 Ω > 10 8 Ω Pollution degree IEC 60 664-12) 3 1) 3 Material group IEC 60 664-1 I II Test voltage IEC 60 664-1 3 + 4 cont. 1,4 kV AC 5 cont. 1,0 kV AC Climatic category IEC 60 068-1 25 / 85 / 21 Temperature range IEC 60 512-6, test 11 i + j – 25°C - + 85°C Rated impulse voltage 2) 2) 0,5 kV AC – Climatic characteristics without LED: 30 / 100 / 56 with LED: 30 / 80 / 56 without LED: – 30°C - +100°C – 13°F - +185°F – 22°F - +212°F with LED: – 30°C - + 80°C – 22°F - +176°F Materials Contact insert TPU PA Contact plating Au Ag Overmolding TPU PA Housing – PA Knurled screw / knurled nut CuZn nickel plated PA O-Ring Viton NBR IEC 60 529 IP 65 and IP 67 when properly mated IP 65 when properly mated Mechanical operation IEC 60 512-5, Test 9 a ≥ 100 mating cycles ≥ 50 mating cycles Insertion force IEC 60 512-7, Test 13 b ≤ 25 N ≤ 25 N Withdrawal force IEC 60 512-7, Test 13 b ≤ 30 N ≤ 30 N Type of termination crimp (overmolded) screw clamps Wire size 0,34 mm2 (AWG 22) 0,14 - 0,5 mm2 (AWG 24-20) Flammability UL 94 HB UL 94 V-0 Locking Screw coupling Screw coupling Mechanical characteristics Protection class Other technical characteristics 1) In mated position only 2) IEC 60664-1 corresponds to DIN VDE 0110 3) Contact no. 5 is “first mate – last break“ and can be used for grounding purpose. When grounding the customer must mark the wire. Furthermore the user has to ensure that this connector is not mated with such connectors where contact no 5 is under voltage 8 Cable construction PVC ● ● Partly oil and chemical proof Especially suited for dry areas Color code Conductors Cable jacket Ø mm material Cable 01 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PVC Cable 02 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PVC Cable 03 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PVC Cable 07 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PVC shielded Cable 08 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PVC shielded Cable 09 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PVC shielded Cable construction PUR ● ● Very good oil and chemical resistance Especially suited for applications in the machine and installation area with rough environments, also in the food industry Color code Conductors Cable jacket Ø mm material Cable 04 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PUR Cable 05 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PUR Cable 06 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PUR Cable 10 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PUR shielded Cable 11 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PUR shielded Cable 12 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PUR shielded Ordering example for different cable lengths C 112 10A 2.0 m 5.0 m 10.0 m 013 ___ 10 020 050 100 Standard cable lengths: 2 m and 5 m. Non-standard cable lengths upon request. Minimum order quantities will apply. 9 Male cable connector, straight, unshielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 10A013 10A013 10A013 10A043 10A043 10A043 10A024 10A024 10A024 10A054 10A054 10A054 10A035 10A035 10A035 10A065 10A065 10A065 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts first mate – last break Male cable connector, right angled, unshielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 10B013 10B013 10B013 10B043 10B043 10B043 10B024 10B024 10B024 10B054 10B054 10B054 10B035 10B035 10B035 10B065 10B065 10B065 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts first mate – last break 10 Female cable connector, straight, unshielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 10C013 10C013 10C013 10C043 10C043 10C043 10C024 10C024 10C024 10C054 10C054 10C054 10C035 10C035 10C035 10C065 10C065 10C065 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts Female cable connector, right angled, unshielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 10D013 10D013 10D013 10D043 10D043 10D043 10D024 10D024 10D024 10D054 10D054 10D054 10D035 10D035 10D035 10D065 10D065 10D065 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts 11 Male cable connector, straight, shielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 11A073 11A073 11A073 11A103 11A103 11A103 11A084 11A084 11A084 11A114 11A114 11A114 11A095 11A095 11A095 11A125 11A125 11A125 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts first mate – last break Male cable connector, right angled, shielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 11B073 11B073 11B073 11B103 11B103 11B103 11B084 11B084 11B084 11B114 11B114 11B114 11B095 11B095 11B095 11B125 11B125 11B125 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts first mate – last break 12 Female cable connector, straight, shielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 11C073 11C073 11C073 11C103 11C103 11C103 11C084 11C084 11C084 11C114 11C114 11C114 11C095 11C095 11C095 11C125 11C125 11C125 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 020 050 100 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts Female cable connector, right angled, shielded with anti-vibration coupling nut and overmolded cable A-coded Contacts 3 4 5 Cable jacket length 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m 2m PVC 5m 10 m 2m PUR 5m 10 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 11D073 11D073 11D073 11D103 11D103 11D103 11D084 11D084 11D084 11D114 11D114 11D114 11D095 11D095 11D095 11D125 11D125 11D125 Other cable lengths, cables and codings upon request. 3 contacts 4 contacts 5 contacts 13 14 Male cable connectors / Female cable connectors customer assembly C112 Series Male cable connector, unshielded, straight and right angled, customer assembly... Page 16 Female cable connector, unshielded, straight and right angled, customer assembly... Page 16 Description Male and female cable connectors, straight and right angled for customer assembly. Female cable connectors, right angled, for customer assembly, with electronic circuit. Male cable connector and Female cable connector, shielded customer assembly... Page 17 Female cable connector, right angled customer assembly... Page 17 15 Male cable connectors, unshielded Metal locking nut for customer assembly, A-coded Screw connection 4 Ampere wire size 0,25 - 0,75 mm2 cable diameter 4 - 6 mm Female cable connectors, unshielded Metal locking nut for customer assembly, A-coded Screw connection 4 Ampere wire size 0,25 - 0,75 mm2 cable diameter 4 - 6 mm 16 Contacts Voltage 4 5 straight right angled straight 60 V right angled 250 V Contacts Voltage 4 5 Design Design straight right angled straight 60 V right angled 250 V Order No. C112 C112 C112 C112 13A004 13B004 13A005 13B005 000 000 000 000 24 24 24 24 000 000 000 000 24 24 24 24 Order No. C112 C112 C112 C112 13C004 13D004 13C005 13D005 Male cable connectors, shielded, straight for customer assembly, A-coded Screw connection 4 Ampere wire size 0,25-0,75 mm2 cable diameter 4-6 mm Contacts Vol- Order No. tage 4 250 V C112 14A004 000 24 5 60 V C112 14A005 000 24 Female cable connector, shielded, straight for customer assembly, A-coded Screw connection 4 Ampere wire size 0,25-0,75 mm2 cable diameter 4-6 mm Contacts Vol- Order No. tage 4 250 V C112 14A004 000 24 5 60 V C112 14A005 000 24 Female cable connector, right angled customer assembly Contacts 3 3+PE 3 LED 1 – – LED 2 – – – yel. – – yel. gre. – – Circuit Order No. 1 2 3 4 5 6 7 8 C112 C112 C112 C112 C112 C112 C112 C112 13D004 13D004 13D004 13D004 13D004 13D004 13D004 13D004 000 000 000 000 000 000 000 000 01 02 03 04 05 06 07 08 Wiring scheme Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 Circuit 6 Circuit 7 Circuit 8 17 18 Cordsets overmolded C 112 Series Cordset, unshielded Male connector, straight/Female connector, straight overmolded with anti-vibration coupling nut ... Page 22 Cordset, unshilded Male connector, straight/Female connector, right angled overmolded with anti-vibration coupling nut ... Page 22 Description M12 cordset with male and female connector, straight or right angled and standard cable with PVC or PUR insulation. Other combinations on request. Shielded EMI protected M12 cordsets with male and female connector, straight or right angled, and standard cable with PVC or PUR insulation. Other combinations on request. Cordset, shielded Male connector, straight/Female connector, straight overmolded with anti-vibration coupling nut ... Page 23 Cordset, shielded Male connector, straight/Female connector, right angled overmolded with anti-vibration coupling nut ... Page 23 19 General characteristics Standard Number of contacts Standard Version Shielded 3/4/5 3 / 4 / 5 3) 3) Electrical characteristics Contact resistance IEC 60 512-2, test 2 a ≤ 10 mΩ (without cable) Current carrying capacity IEC 60 512-3, test 5 b 4 A at Tu = 40°C Rated voltage IEC 60 664-12) 3+4 cont. 250 V AC / DC 3 + 4 cont. 60 V AC/DC IEC 60 664-1 5 cont. 60 V AC / DC 5 cont. 60 V AC/DC IEC 60 664-1 3 + 4cont. 2,5 kV 3 + 4 cont. 0,8 kV IEC 60 664-12) 5 cont. 1,5 kV 5 cont. 0,8 kV Insulation resistance IEC 60 512-2, test 3 a > 10 8 Ω Pollution degree IEC 60 664-1 3 1) Material group IEC 60 664-12) I Test voltage IEC 60 644-12) 3 + 4 cont. 1,4 kV AC 5 cont. 1,0 kV AC 2) Rated impulse voltage 2) 2) 0,5 kV AC Climatic characteristics Climatic category IEC 60 668-1 25 / 85 / 21 Temperature range IEC 60 512-6, test 11 i + j – 25°C - + 85°C – 13°F - + 185°F Materials Contact insert TPU Contact plating Au Overmolding TPU Housing – Knurled screw / knurled nut CuZn nickel plated O-Ring Viton Mechanical characteristics Protection class IEC 60 529 IP 65 and IP 67, when properly mated Mechanical operation IEC 60 512-5, test 9 a ≥ 100 mating cycles Insertion force IEC 60 512-7, test 13 b ≤ 25 N Withdrawal force IEC 60 512-7, test 13 b ≤ 30 N Other technical characteristics Type of termination crimp (overmolded) Wire size 0,34 mm 2 (AWG 22) Flammability UL 94 HB Locking Screw coupling 1) In mated position only 2) IEC 60664-1 corresponds to DIN VDE 0110 3) Contact no. 5 is “first mate – last break“ and can be used for grounding purpose. When grounding the customer must mark the wire. Furthermore the user has to ensure that this connector is not mated with such connectors where contact no 5 is under voltage 20 Cable construction PVC ● ● Fair oil and chemical resistance Especially suited for dry areas Color code Conductors Cable jacket Ø mm material Cable 01 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PVC Cable 02 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PVC Cable 03 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PVC Cable 07 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PVC shielded Cable 08 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PVC shielded Cable 09 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PVC shielded Color code Conductors Cable jacket Ø mm material Cable 04 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PUR Cable 05 Brown, white, blue, black 4 x 0,34 mm (AWG 22) 5 PUR Cable 06 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PUR Cable 10 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) 5 PUR shielded Cable 11 Brown, white, blue, black 4 x 0,34 mm 2 (AWG 22) 5 PUR shielded Cable 12 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) 5 PUR shielded Cable construction PUR ● ● Good oil and chemical resistance Especially suited for applications in abrasive environments. 2 Ordering example for different cable lengths C 112 20C 0.6 m 1.0 m 2.0 m 013 ___ 006 010 020 Standard cable length: 0.6 m, 1.0 m and 2.0 m. Other cable lengths or cables upon request. 21 Cordset, unshielded Male connector, straight / Female connector, straight with anti-vibration coupling nut A-coded Contacts 3 4 5 3 contacts 4 contacts 5 contacts Cable jacket length 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 20C013 20C013 20C013 20C043 20C043 20C043 20C024 20C024 20C024 20C054 20C054 20C054 20C035 20C035 20C035 20C065 20C065 20C065 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths upon request. Male cable connector first mate – last break Female cable connector Cordset, umshielded Male connector, straight / Female connector, right angled with anti-vibration coupling nut A-coded Contacts 3 4 5 3 contacts 4 contacts 5 contacts Male cable connector first mate – last break Female cable connector 22 Cable jacket length 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 20D013 20D013 20D013 20D043 20D043 20D043 20D024 20D024 20D024 20D054 20D054 20D054 20D035 20D035 20D035 20D065 20D065 20D065 Other cable lengths upon request. Cordset, shielded Male connector, straight / Female connector, straight with anti-vibration coupling nut A-coded Contacts 3 4 5 3 contacts 4 contacts 5 contacts Cable jacket length 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 21C073 21C073 21C073 21C103 21C103 21C103 21C084 21C084 21C084 21C114 21C114 21C114 21C095 21C095 21C095 21C125 21C125 21C125 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 006 010 020 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Other cable lengths upon request. Male cable connector first mate – last break Female cable connector Cordset, shielded Male connector, straight / Female connector, right angled with anti-vibration coupling nut A-coded Contacts 3 4 5 3 contacts 4 contacts 5 contacts Cable jacket length 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m 0,6 m PVC 1,0 m 2,0 m 0,6 m PUR 1,0 m 2,0 m Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 21D073 21D073 21D073 21D103 21D103 21D103 21D084 21D084 21D084 21D114 21D114 21D114 21D095 21D095 21D095 21D125 21D125 21D125 Other cable lengths upon request. Male cable connector first mate – last break Female cable connector 23 24 Male and female panel connectors C 112 Series Description Male panel connector, front mounting assembled with wires ... Page 27 M12 male and female panel connectors for front or rear mounting, assembled with wires. M12 male and female panel connectors with pcb-mount type. Female panel connector, front mounting assembled with wires ... Page 27 M12 male panel connectors installation version. Male panel connector, rear mounting assembled with wires ... Page 28 Female panel connector, rear mounting assembled with wires ... Page 28 Female panel connector, rear mounting pcb-mount type ... Page 29 Male panel connector installation version ... Page 29 Male panel connector, rear mounting pcb-mount type ... Page 29 25 General characteristics Standard Standard Version Customer Assembly 3/4/5/8 3/4 IEC 60 512-2, test 2 a ≤ 10 mΩ (without cable) ≤ 10 mΩ 4 A at Tu = 40°C Number of contacts Electrical characteristics Contact resistance IEC 60 512-3, test 5 b 3+4+5-cont. 4 A at Tu = 40°C IEC 60 512-3, test 5 b 8-cont. 2 A at Tu = 40°C IEC 60 664-12) 3+4 cont. 250 V AC / DC IEC 60 664-1 5 cont. 60 V AC / DC IEC 60 664-12) 8-cont. 30 V AC/DC Rated impulse voltage IEC 60 664-1 3 + 4 cont. 2,5 kV unmated IEC 60 664-12) 5 cont. 1,5 kV IEC 60 664-12) 8-cont. 0,8 kV Insulation resistance IEC 60 512-2, test 3 a > 10 8 Ω > 10 8 Ω Pollution degree IEC 60 664-1 3 3 Material group IEC 60 664-12) I Test voltage IEC 60 664-1 3 + 4 cont. 1,4 kV AC 5 cont. 1,0 kV AC Climatic category IEC 60 068-1 25 / 85 / 21 30 / 100 / 56 Temperature range IEC 60 512-6, test 1.1 – 25°C - + 85°C – 30°C - +100°C – 13°F - + 185°F – 22°F - +212°F Current carrying capacity Rated voltage 2) 2) 2) 2) 1) 250 V AC / DC 2,5 kV II Climatic characteristics Materials Contact insert TPU PA Contact plating Au Ag Housing / Mounting screw CuZn nickel plated PA O-Ring Viton NBR Mechanical characteristics Protection class IEC 60 529 IP 65 and IP 67 when properly mated IP 65 when properly mated Mechanical operation IEC 60 512-5, test 9 a ≥ 100 mating cycles ≥ 50 mating cycles Insertion force IEC 60 512-7, test 13 b ≤ 25 N ≤ 25 N Withdrawal force IEC 60 512-7, test 13 b ≤ 30 N ≤ 30 N Other technical characteristics Type of termination crimp solder Wire size 0,34 mm (AWG 22) 0,14 - 0,5 mm 2 Flammability UL 94 HB UL 94 V-0 Locking Screw coupling Screw coupling Insulation 2 1) In mated position only 2) IEC 60664-1 corresponds to DIN VDE 0110 Wire construction Color code Conductors Wire 01 Brown, blue, black 3 x 0,34 mm 2 (AWG 22) PVC Wire 02 Brown, white, blue, black 4 x 0,34 mm (AWG 22) PVC Wire 03 Brown, white, blue, black, grey 5 x 0,34 mm 2 (AWG 22) PVC Wire 04 Brown, white, blue, grey, green, yellow, red, pink 8 x 0,25 mm2 (AWG 24) PVC 26 2 Male panel connector, front mounting with PVC-isulated wire spanner width SW 17 A-coded Con- Colors of tacts wire insulation 3 4 5 8 Brown-blueblack Brown-whiteblue-black Brown-whiteblue-blackgrey Brown-whiteblue-greygreen-yellowred-pink Mounting thread PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 Lead length 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 30A013 30A013 30A013 30A013 30A024 30A024 30A024 30A024 30A035 30A035 30A035 30A035 30A048 30A048 30A048 30A048 002 005 002 005 002 005 002 005 002 005 002 005 002 005 002 005 10 10 30 30 10 10 30 30 10 10 30 30 10 10 30 30 002 005 002 005 002 005 002 005 002 005 002 005 002 005 002 005 10 10 30 30 10 10 30 30 10 10 30 30 10 10 30 30 Other lead lengths and codings upon request. 3 contacts 4 contacts 5 contacts Female panel connector, front mounting with PVC-isulated wire spanner width SW 17 A-coded 8 contacts Con- Colors of tacts wire insulation 3 4 5 8 Brown-blueblack Brown-whiteblue-black Brown-whiteblue-blackgrey Brown-whiteblue-greygreen-yellowred-pink Mounting thread PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 Lead length 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 30C013 30C013 30C013 30C013 30C024 30C024 30C024 30C024 30C035 30C035 30C035 30C035 30C048 30C048 30C048 30C048 Other lead lengths and codings upon request. 3 contacts 4 contacts 5 contacts 8 contacts 27 Male panel connector, rear mounting with PVC-isulated wire spanner width SW 17 A-coded Con- Colors of tacts wire insulation 3 4 5 8 Brown-blueblack Brown-whiteblue-black Brown-whiteblue-blackgrey Brown-whiteblue-greygreen-yellowred-pink Mounting thread PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 Lead length 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 30B013 30B013 30B013 30B013 30B024 30B024 30B024 30B024 30B035 30B035 30B035 30B035 30B048 30B048 30B048 30B048 002 005 002 005 002 005 002 005 002 005 002 005 002 005 002 005 10 10 30 30 10 10 30 30 10 10 30 30 10 10 30 30 002 005 002 005 002 005 002 005 002 005 002 005 002 005 002 005 10 10 30 30 10 10 30 30 10 10 30 30 10 10 30 30 Other lead lengths and codings upon request. 3 contacts 4 contacts 5 contacts Female panel connector, rear mounting with PVC-isulated wire spanner width SW 17 A-coded 8 contacts Con- Colors of tacts wire insulation 3 4 5 8 Brown-blueblack Brown-whiteblue-black Brown-whiteblue-blackgrey Brown-whiteblue-greygreen-yellowred-pink Mounting thread PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 PG9 M 16 x 1,5 Lead length 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm 200 mm 500 mm Other lead lengths and codings upon request. 3 contacts 28 4 contacts 5 contacts 8 contacts Order No. C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 C112 30D013 30D013 30D013 30D013 30D024 30D024 30D024 30D024 30D035 30D035 30D035 30D035 30D048 30D048 30D048 30D048 Male panel connector, rear mounting pcb-mount type Contacts Order No. 4 C112 30X004 000 XX 5 C112 30X005 000 XX Please indicate contact length coding, PG- or metric mounting thread to allow us to determine your connector type. L1 Female panel connector, rear mounting pcb-mount type L2 Coding PG 9 A M 16 B Contacts Order No. 4 C112 30X004 000 XX 5 C112 30X005 000 XX Please indicate contact length coding, PG- or metric mounting thread to allow us to determine your connector type. L1 Male panel connector, installation version L2 Coding PG 9 A M 16 B Contacts Order No. 3+PE C112 31A003 000 10 4 C112 31A004 000 10 29 30 Distributors C 112 Series Y-Distributor ... Page 33 Description M12-Y-Distributor for twofold distribution. Ready to use M12-Distribution boxes with 4-, 6- and 8-way distribution. Distribution boxes ... Page 34 4-, 6- and 8-way 31 General characteristics Standard Contacts Y-Distributor Distribution Box 3/4/5 5 ≤ 5 mΩ (single contact) Electrical characteristics Contact resistance IEC 60 512-2, test 2 a ≤ 5 mΩ (single contact) Current carrying capacity IEC 60 512-3, test 5 b 4 A / 40°C 2 A / 40°C Rated voltage IEC 60 664-1 60 V AC / DC 30 V Rated impulse voltage IEC 60 664-1 0,8 kV 0,8 kV Insulation resistance IEC 60 512-2, test 3 a > 10 8 Ω > 10 8 Ω Pollution degree IEC 60 664-12) 31) 2 Material group IEC 60 664-1 I – Test voltage IEC 60 664-12) 0,5 kV AC 0,5 kV AC Climatic category IEC 60 068-1 25 / 85 / 21 – Temperature range IEC 60 512-6, test 11 i + j ≤ 25 mΩ (complete circuit) 2) 2) 2) Climatic characteristics – 25°C - + 85°C – 20°C - + 90°C – 13°F - + 185°F – 4°F - + 194°F TPU PBT Materials Contact insert Contact plating Au Au Body TPU – Housing – PBT Knurled screw / knurled nut CuZn nickel plated – O-Ring Viton – Mechanical characteristics Protection class IEC 60 529 IP 67 when properly mated IP 67 when properly mated Mechanical operation IEC 60 512-5, test 9 a ≥ 100 mating cycles ≥ 100 mating cycles Insertion force IEC 60 512-7, test 13 b ≤ 25 N ≤ 25 N Withdrawal force IEC 60 512-7, test 13 b ≤ 30 N ≤ 30 N Other technical characteristics Type of termination crimp (overmolded) solder Wire size 0,34 mm (AWG 22) – Flammability UL 94 HB UL 94 V-0 Locking Screw coupling Screw coupling 1) In mated position only 2) IEC 60664-1 corresponds to DIN VDE 0110 32 2 Y-Distributor A-coded One entrence, two parallel exits. Other Connections upon request. Contacts Design unshielded 4 5 Order No. Contacts Design m / fm - fm C112 40A004 000 10 fm / m - m C112 40B004 000 10 fm / m - fm C112 40E004 000 10 m / fm - m m / fm - fm fm / m - m C112 40B005 000 10 fm / m - fm C112 40E005 000 10 m / fm - m C112 40F005 000 10 shielded Order No. m / fm - fm C112 41A004 000 10 fm / m - m C112 41B004 000 10 fm / m - fm C112 41E004 000 10 C112 40F004 000 10 m / fm - m C112 41F004 000 10 C112 40A005 000 10 m / fm - fm C112 41A005 000 10 fm / m - m C112 41B005 000 10 fm / m - fm C112 41E005 000 10 m / fm - m C112 41F005 000 10 m = male; fm = female Version A: m / fm - fm Version B: fm / m - m Version E: fm / m - fm Version F: m / fm - m 4 5 m = male; fm = female 33 Distribution boxes 4-, 6- and 8-way 34 Contacts Distribution Order No. 5 4-way C112 50U004 000 10 6-way C112 50U006 000 10 8-way C112 50U008 000 10 Order number register Order No. Page Order No. Page Order No. Page C112 10A013...10 10 C112 13B004 000 24 16 C112 30B013...10 28 C112 10A024...10 10 C112 13B005 000 24 16 C112 30B024...10 28 C112 10A035...10 10 C112 13C004 000 24 16 C112 30B035...10 28 C112 10A043...10 10 C112 13C005 000 24 16 C112 30B048...10 28 C112 10A054...10 10 C112 13D004 000 24 16 C112 30B013... 30 28 C112 10A065...10 10 C112 13D005 000 24 16 C112 30B024... 30 28 C112 10B013...10 10 C112 13D004 000 01 17 C112 30B035... 30 28 C112 10B024...10 10 C112 13D004 000 02 17 C112 30B048... 30 28 C112 10B035...10 10 C112 13D004 000 03 17 C112 30C013...10 27 C112 10B043...10 10 C112 13D004 000 04 17 C112 30C024...10 27 C112 10B054...10 10 C112 13D004 000 05 17 C112 30C035...10 27 C112 10B065...10 10 C112 13D004 000 06 17 C112 30C048...10 27 C112 10C013...10 11 C112 13D004 000 07 17 C112 30C 013... 30 27 C112 10C024...10 11 C112 13D004 000 08 17 C112 30C 024... 30 27 C112 10C035...10 11 C112 14A004 000 24 17 C112 30C 035... 30 27 C112 10C043...10 11 C112 14A005 000 24 17 C112 30C 048... 30 27 C112 10C054...10 11 C112 14C004 000 24 17 C112 30D013...10 28 C112 10C065...10 11 C112 14C005 000 24 17 C112 30D024...10 28 C112 10D013...10 11 C112 20C013...10 22 C112 30D035...10 28 C112 10D024...10 11 C112 20C024...10 22 C112 30D048...10 28 C112 10D035...10 11 C112 20C035...10 22 C112 30D013... 30 28 C112 10D043...10 11 C112 20C043...10 22 C112 30D024... 30 28 C112 10D054...10 11 C112 20C054...10 22 C112 30D035... 30 28 C112 10D065...10 11 C112 20C065...10 22 C112 30D048... 30 28 C112 11A073...10 12 C112 20D013...10 22 C112 30X004 000 XX 29 C112 11A084...10 12 C112 20D024...10 22 C112 30X005 000 XX 29 C112 11A095...10 12 C112 20D035...10 22 C112 31A003 000 10 29 C112 11A103...10 12 C112 20D043...10 22 C112 31A004 000 10 29 C112 11A114...10 12 C112 20D054...10 22 C112 40A004 000 10 33 C112 11A125...10 12 C112 20D065...10 22 C112 40A005 000 10 33 C112 11B073...10 12 C112 21C073...10 23 C112 40B004 000 10 33 C112 11B084...10 12 C112 21C084...10 23 C112 40B005 000 10 33 C112 11B095...10 12 C112 21C095...10 23 C112 40E004 000 10 33 C112 11B103...10 12 C112 21C103...10 23 C112 40E005 000 10 33 C112 11B114...10 12 C112 21C114...10 23 C112 40F004 000 10 33 C112 11B125...10 12 C112 21C125...10 23 C112 40F005 000 10 33 C112 11C073...10 13 C112 21D073...10 23 C112 41A004 000 10 33 C112 11C084...10 13 C112 21D084...10 23 C112 41A005 000 10 33 C112 11C095...10 13 C112 21D095...10 23 C112 41B004 000 10 33 C112 11C103...10 13 C112 21D103...10 23 C112 41B005 000 10 33 C112 11C114...10 13 C112 21D114...10 23 C112 41E004 000 10 33 C112 11C125...10 13 C112 21D125...10 23 C112 41E005 000 10 33 C112 11D073...10 13 C112 30A013...10 27 C112 41F004 000 10 33 C112 11D084...10 13 C112 30A024...10 27 C112 41F005 000 10 33 C112 11D095...10 13 C112 30A035...10 27 C112 50U004 000 10 34 C112 11D103...10 13 C112 30A048...10 27 C112 50U006 000 10 34 C112 11D114...10 13 C112 30A 013... 30 27 C112 50U008 000 10 34 C112 11D125...10 13 C112 30A 024... 30 27 C112 13A004 000 24 16 C112 30A 035... 30 27 C112 13A005 000 24 16 C112 30A 048... 30 27 35 International Argentina Amphenol Argentina Av. Callao 930 2nd Floor Office B “Plaza“ C 1023 AAP Buenos Aires Phone +54 / 11 / 48 15 68 86 Fax +54 / 11 / 48 14 57 79 Hong Kong Amphenol East Asia Limited Units 2201-02, Railway Plaza 39 Chatham Road South Tsimshatsui, Kowloon Phone +8 52 / 26 99 / 26 63 Fax +8 52 / 26 88 / 09 74 Australia Amphenol Australia Ltd. 2 Fiveways Blvd Keysborough Victoria 31 73 Phone +61 / 3 / 87 96 / 88 88 Fax +61 / 3 / 87 96 / 88 01 India Amphetronix Limited Plot No. 105 Bhosari Industrial Area Pune - 411 026 Phone +91 / 20 / 27121418 Fax +91 / 20 / 2712 05 81 Belgium Amphenol-Tuchel Belgium Brusselbaan 524b B 1600 Sint-Pieters-Leeuw Phone +32 / 23 77 / 25 49 Fax +32 / 23 77 / 53 03 Brasilia Amphenol do Brasil Ltda. Rua Diogo Moreira 132, 20th Floor CEP 05423-010 Sao Paulo SP Phone +55 / 11 / 38 15.10 03 Fax +55 / 11 / 38 15.16 29 China Amphenol-Tuchel Electronics GmbH China Branch 210-1 Taishan Road Changzhou 213 022 Phone +86 / 05 19 / 5 11 03 01 Fax +86 / 05 19 / 5 11 02 99 ATE 3110 C 0605 3.000 (13267) Printed on chlorin-free bleached paper, specifications may be changed without notice. Copyright 03/05 by Amphenol-Tuchel Electronics GmbH, Germany France Amphenol-Tuchel France Bât. Le Newton C 7 Mail B. Thimonnier 77185 Lognes Phone +33 / 164 62 76 76 Fax +33 / 164 62 76 77 Germany Amphenol-Tuchel Electronics GmbH August-Haeusser-Str. 10 74980 Heilbronn Phone +49 / 71 31 / 9 29-0 Fax +49 / 71 31 / 9 29-486 Great Britain Amphenol-Tuchel Great Britain 39 Rowlands Castle Road Horndean Waterlooville, Hants P08 0DF Phone +44 / 23 92 / 57 17 91 Fax +44 / 23 92 / 57 17 91 Your engineering sales reprensentives: Italy Amphenol-Tuchel Italy Via Barbaiana n. 5 l-20020 Lainate (MI) Phone +39 / 2 / 93 25 41 Fax +39 / 2 / 93 25 44 44 Japan Amphenol Japan, K.K. 2-3-27, Kudan Minami Chiyoda-Ku Tokyo 102 Phone +81 / 3 / 32 63 / 56 11 Fax +81 / 3 / 52 76 / 70 59 Korea Amphenol DaeShin Limited #802 Joong-Dong 1131-5 Wonmi-Ku Bucheon-City Kyunggi-Do Korea 420-020 Phone +82 / 2 / 785 / 15 88 Fax +82 / 2 / 589 / 15 14 Mexico Amphenol Mexico Prolongacion Reforma 61 - 6 B2 Col. Paseo de las Lomas C.P. 01330 Mexico D.F. Phone +52 / 55 / 52 58.99 84 Fax +52 / 55 / 50 81.68 90 Singapur Amphenol East Asia Limited Asia Pacific Sales Operation Singapore Branch 300 Beach Road #25-07 The Concourse Singapore 199555 Phone +27 / 11 / 305-95 74 Fax +27 / 11 / 305-95 76 South Africa Amphenol International Ltd Chislehurston 30 Impala Road Chislehurston Sandton, 2146 Phone +27 / 11 / 7 83 95 17 Fax +27 / 11 / 7 83 95 19 Spain Amphenol-Tuchel Spain Ctra Sabadell a Mollet, km 4,5 Nave 5 08130 Santa Perpetue de Mogoda (Barcelona) Phone +34 / 93 / 5 74 41 34 Fax +34 / 93 / 5 74 10 09 Sweden Amphenol-Tuchel Scandinavia P.O. Box 20 SE 195 42 Märsta Phone +46 / 85 91 / 1 75 76 Fax +46 / 85 91 / 1 75 76 Taiwan Amphenol East Asia Ltd. Taiwan Branch (H.K.) 116 Zhong Shan Road Lane 956 Taoyuan City Taiwan R.O.C. 330 Phone +886 / 3 / 370 / 78 55 Fax +886 / 3 / 360 / 72 59 Turkey Amphenol Turkiye Ayazaga Mah. Meydan Sk. No. 28 Beybi Giz Plaza, Kat. 26 34396 Maslak / Istanbul Phone +90 / 0212 / 3 35 25 01 Fax +90 / 0212 / 3 35 25 00 USA Amphenol-Tuchel Electronics Representative Office 6900 Haggerty Road Suite 200 Canton, Michigan 48187 Phone +1 / 800 / 380 80 52 Phone +1 / 734 / 451 64 00 Fax +1 / 734 / 451 71 97 Amphenol Corporation Corporate Headquarters 358 Hall Avenue Wallingford, CT 06492 Phone +1 / 2 03 / 2 65 / 89 00 Fax +1 / 2 03 / 2 65 / 86 28 General information We reserve the right to chance the design due to imporvement in quality, development or production requirments. This catalogue must not be used in any form or manner without our prior approval in writing (Copyright Law, Fair Trading Law, Civil Code). Amphenol Amphenol-Tuchel Electronics GmbH August-Haeusser- Str. 10 . D-74080 Heilbronn · Deutschland . Phone +49 (0 )71 31/ 9 29-0 . Fax +49 (0 )71 31/ 9 29- 486 · www.amphenol.info
C11210A05402010 价格&库存

很抱歉,暂时无法提供与“C11210A05402010”相匹配的价格&库存,您可以联系我们找货

免费人工找货