CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Rev. 7 — 5 February 2018
Product data sheet
1. Product profile
1.1 General description
The CLF1G0060-30 and CLF1G0060S-30 are 30 W general purpose broadband GaN
HEMTs usable from DC to 6.0 GHz.
Table 1.
CW and pulsed RF application information
Typical RF performance at Tcase = 25 C; IDq = 70 mA; VDS = 50 V in a class-AB broadband demo
board.
Test signal
1-Tone CW
1-Tone pulsed
[1]
[1]
f
PL
Gp
D
(MHz)
(W)
(dB)
(%)
500
30
15.6
60.7
1000
30
13.9
50.3
1500
30
13.7
50.8
2000
30
12.6
49
2500
30
14.2
55.6
500
30
16.6
61
1000
30
15.8
50
1500
30
15.5
52.5
2000
30
14.5
50
2500
30
15.9
59
Pulsed RF; tp = 100 s; = 10 %.
Table 2.
2-Tone CW application information
Typical 2-Tone performance at Tcase = 25 C; IDq = 150 mA; VDS = 50 V in a class-AB broadband
demo board.
Test signal
2-Tone CW [1]
[1]
2-Tone CW; f = 1 MHz.
f
PL(PEP)
IMD3
(MHz)
(W)
(dBc)
500
10
38
1000
10
50
1500
10
45
2000
10
50
2500
10
43
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
1.2 Features and benefits
Frequency of operation is from DC to 6.0 GHz
30 W general purpose broadband RF Power GaN HEMT
Excellent ruggedness (VSWR = 10 : 1)
High voltage operation (50 V)
Thermally enhanced package
1.3 Applications
Commercial wireless infrastructure
(cellular, WiMAX)
Radar
Broadband general purpose amplifier
Public mobile radios
Industrial, scientific, medical
Jammers
EMC testing
Defense application
2. Pinning information
Table 3.
Pinning
Pin
Description
Simplified outline
Graphic symbol
CLF1G0060-30 (SOT1227A)
1
drain
2
gate
3
source
1
1
2
[1]
2
3
3
aaa-003693
CLF1G0060S-30 (SOT1227B)
1
drain
2
gate
3
source
1
1
2
[1]
3
2
[1]
aaa-003693
Connected to flange.
3. Ordering information
Table 4.
Ordering information
Type number
CLF1G0060-30_1G0060S-30
Product data sheet
Package
Name
Description
CLF1G0060-30
-
flanged ceramic package; 2 mounting holes; 2 leads SOT1227A
CLF1G0060S-30
-
earless flanged ceramic package; 2 leads
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
Version
SOT1227B
© Ampleon Netherlands B.V. 2018. All rights reserved.
2 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
4. Limiting values
Table 5.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
Conditions
Min
Max
Unit
VDS
VGS
drain-source voltage
-
150
V
gate-source voltage
8
+3
V
IGF
forward gate current
-
11
mA
Tstg
storage temperature
65
+150
C
Tj
junction temperature
-
250
C
external RG = 5
measured via IR scan
5. Thermal characteristics
Table 6.
Thermal characteristics
Symbol
Parameter
Conditions
Rth(j-c)
thermal resistance from junction to case
Tj = 200 C
[1]
[1]
Typ
Unit
3.1
K/W
Tj is measured via IR scan with case temperature of 85 C and power dissipation of 34 W.
6. Characteristics
Table 7.
DC Characteristics
Tcase = 25 C; unless otherwise specified.
Symbol Parameter
Conditions
V(BR)DSS drain-source breakdown voltage VGS = 7 V;
IDS = 7.2 mA
Min
Typ
Max
Unit
150
-
-
V
VGS(th)
gate-source threshold voltage
VDS = 0.1 V;
IDS = 7.2 mA
2.4
2
1.6
V
IDSX
drain cut-off current
VDS = 10 V; VGS = 3 V
-
5.1
-
A
gfs
forward transconductance
VDS = 10 V; VGS = 0 V
-
1.1
-
S
Table 8.
RF Characteristics
Test signal: pulsed RF; f = 3 GHz; tp = 100 s; = 10 %; RF performance at VDS = 50 V;
IDq = 70 mA; Tcase = 25 C; unless otherwise specified in a class-AB production circuit.
Symbol
Parameter
Conditions
D
drain efficiency
PL = 30 W
46
54
-
%
Gp
power gain
PL = 30 W
11.8
13.5
-
dB
RLin
input return loss
PL = 30 W
-
7
-
dB
PL = 30 W
-
0.04
-
dB
Pdroop(pulse) pulse droop power
CLF1G0060-30_1G0060S-30
Product data sheet
Min
Typ
Max
Unit
tr
rise time
PL = 30 W
-
5
-
ns
tf
fall time
PL = 30 W
-
5
-
ns
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
3 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
7. Application information
7.1 Demo circuit
CLF1G0060-30 500-2500
INPUT REV 0 30RF35
CLF1G0060-30 500-2500
INPUT REV 0 30RF35
C8
C2
C7
C9
C1
R1
C10
L3
L1
R2
C3
C11
C6
C12
C15
C4 C5
C14
L2
C16
Q2
Q3
GAN BIAS
MODULE
R3
C17
aaa-003736
Printed-Circuit Board (PCB) material: Taconic RF35, r = 3.5, thickness 30 mils, 1 oz copper on
each side.
See Table 9 for list of components.
Fig 1.
The broadband amplifier (500 MHz to 2500 MHz) demo circuit outline
Table 9.
List of components
See Figure 1.
CLF1G0060-30_1G0060S-30
Product data sheet
Component
Description
Value
Remarks
A1
GaN bias module v2
-
Ampleon
C1, C10
multilayer ceramic chip capacitor
8.2 pF
ATC 600F
C2, C7
multilayer ceramic chip capacitor
0.8 pF
ATC 600F
C3
electrolytic capacitor
100 nF, 50 V
SMD 0805
C4
electrolytic capacitor
10 nF, 50 V
SMD 0805
C5
electrolytic capacitor
22 pF, 100 V
SMD 0805
C6
electrolytic capacitor
1 nF, 100 V
SMD 1206
C8
multilayer ceramic chip capacitor
1.2 pF
ATC 600F
C9
multilayer ceramic chip capacitor
0.5 pF
ATC 600F
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
4 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Table 9.
List of components …continued
See Figure 1.
CLF1G0060-30_1G0060S-30
Product data sheet
Component
Description
Value
Remarks
C11
multilayer ceramic chip capacitor
100 pF
ATC 100B
C12
multilayer ceramic chip capacitor
1 nF
ATC 700B
C14
electrolytic capacitor
1 F, 100V
SMD 1206
C15
electrolytic capacitor
10 F, 100 V
SMD 2220
C16
electrolytic capacitor
10 nF, 200 V
SMD 1210
PCE3667CT-ND
C17
electrolytic capacitor
470 F, 63 V
E1, E2
drain voltage connection
-
J1
RF in connector
-
J2
RF out connector
-
L1
inductor
330 nH
1008CS-331XJB
L2
ferrite bead
-
2743019447
L3
inductor
-
1 turn, 18 AWG,
inner diameter = 4.06 mm
Q1
transistor
-
CLF1G0060-30
Q2
transistor
-
NXP BC857B
Q3
transistor
-
NXP PSMN8R2-80YS
R1
resistor
10 k
Vishay Dale
R2
resistor
10
Vishay Dale
R3
resistor
0.005
RL7520WT-R005-F
Z1, Z2, Z3,
Z4, Z5, Z6,
Z7, Z8, Z9,
Z10, Z11,
Z12, Z13
microstrip lines
-
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
5 of 19
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx xxxxx
xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx
CLF1G0060-30_1G0060S-30
Product data sheet
+50 V
E1
C15
470 μF
A1
IN
3
4
D
5 Q3
4
G
VG
GAN BIAS 7
MODULE 5 FB
C
GND
10
6
B
GND
11
9
E
12
PSMN8R2-80YS
2
S
1
R2
C6
10 Ω
1 nF
1
C14
3
10 F
C13
C5
Q2
BC857B
R1
10 kΩ
10 nF
C12
22 pF
C4
1 nF
C11
10 nF
L1
330 nH
J1
N-F
Z6
C1
Z5
605 x 67.5 mil 5.6 pF 376 x 67.5 mil
Z4
Z3
210 x 67.5 mil 136 x 67.5 mil
C2
0.3 pF
Z2
40 x 562 mil
Z1
168 x 562 mil
C3
Z7
Z8
Z9
Z10
Z11
60 x 201 mil
59 x 201 mil
273 x 201 mil
58 x 138 mil
572 x 138 mil
Q1
CLF1G0060-30
C9
0.5 pF
6 of 19
© Ampleon Netherlands B.V. 2018. All rights reserved.
See Table 9 for a list of components.
The broadband amplifier (500 MHz to 2500 MHz) demo circuit schematic
C7
0.8 pF
Z12
C10
Z13
400 x 98 mil 5.6 pF 118 x 67.5 mil
J2
N-F
C8
1.2 pF
aaa-003790
Broadband RF power GaN HEMT
R4
200 Ω
Fig 2.
100 pF
L3
5 nH
100 nF
CLF1G0060-30; CLF1G0060S-30
Rev. 7 — 5 February 2018
All information provided in this document is subject to legal disclaimers.
2
5
GND
GND
E2
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
7.2 Application test results
Table 10. CW and pulsed RF application information
Typical RF performance at Tcase = 25 C; IDq = 70 mA; VDS = 50 V in a class-AB broadband demo
board.
Test signal
1-Tone CW
1-Tone pulsed
[1]
[1]
f
PL
Gp
D
(MHz)
(W)
(dB)
(%)
500
30
15.6
60.7
1000
30
13.9
50.3
1500
30
13.7
50.8
2000
30
12.6
49
2500
30
14.2
55.6
500
30
16.6
61
1000
30
15.8
50
1500
30
15.5
52.5
2000
30
14.5
50
2500
30
15.9
59
Pulsed RF; tp = 100 s; = 10 %.
Table 11. 2-Tone CW application information
Typical 2-Tone performance at Tcase = 25 C; IDq = 150 mA; VDS = 50 V in a class-AB broadband
demo board.
Test signal
f
2-Tone CW [1]
[1]
CLF1G0060-30_1G0060S-30
Product data sheet
PL(PEP)
IMD3
(MHz)
(W)
(dBc)
500
10
38
1000
10
50
1500
10
45
2000
10
50
2500
10
43
2-Tone CW; f = 1 MHz.
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
7 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
7.3 Graphical data
The following figures are measured in a broadband amplifier demo board from 500 MHz
to 2500 MHz.
7.3.1 1-Tone CW RF performance
aaa-003960
16
Gp
(dB)
70
Gp
12
80
Gp
(dB)
55
ηD
aaa-003961
24
ηD
(%)
ηD
(%)
(4)
(6)
(5)
18
60
(1)
(3)
(2)
8
40
12
40
4
25
6
20
10
3000
0
0
0
500
1000
1500
2000
2500
f (MHz)
0
34
VDS = 50 V; IDq = 70 mA; PL = 30 W.
36
38
40
42
44
46
PL (dBm)
48
VDS = 50 V; IDq = 70 mA.
(1) Gp at f = 500 MHz
(2) Gp at f = 1500 MHz
(3) Gp at f = 2500 MHz
(4) D at f = 500 MHz
(5) D at f = 1500 MHz
(6) D at f = 2500 MHz
Fig 3.
Power gain and drain efficiency as function of
frequency; typical values
CLF1G0060-30_1G0060S-30
Product data sheet
Fig 4.
Power gain and drain efficiency as function of
output power; typical values
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
8 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
7.3.2 1-Tone pulsed RF performance
aaa-003962
18
Gp
(dB)
70
Gp
15
aaa-003963
24
ηD
(%)
Gp
(dB)
(6)
18
50
9
40
6
30
3
ηD
(%)
(4)
60
ηD
12
80
(1)
60
(5)
(3)
(2)
12
40
6
20
20
0
0
500
1000
1500
2000
2500
f (MHz)
10
3000
VDS = 50 V; IDq = 70 mA; PL = 30 W; tp = 100 s;
= 10 %.
0
0
34
36
38
40
42
44
46
PL (dBm)
48
VDS = 50 V; IDq = 70 mA; tp = 100 s; = 10 %.
(1) Gp at f = 500 MHz
(2) Gp at f = 1500 MHz
(3) Gp at f = 2500 MHz
(4) D at f = 500 MHz
(5) D at f = 1500 MHz
(6) D at f = 2500 MHz
Fig 5.
Power gain and drain efficiency as function of
frequency; typical values
CLF1G0060-30_1G0060S-30
Product data sheet
Fig 6.
Power gain and drain efficiency gain as
function of output power; typical values
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
9 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
7.3.3 2-Tone CW performance
aaa-003964
0
IMD3
(dBc)
-10
aaa-004003
-20
IMD3
(dBc)
(1)
(3)
(2)
(4)
(5)
(6)
-30
(1)
(3)
-20
(2)
-30
-40
-40
-50
-50
-60
1
-60
500
102
10
900
PL(PEP) (W)
VDS = 50 V; IDq = 150 mA; f = 1 MHz.
1300
1700
2100
f (MHz)
2500
VDS = 50 V; IDq = 150 mA; PL(PEP) =10 W.
(1) f = 500 MHz
(1) f = 10 kHz
(2) f = 1500 MHz
(2) f = 30 kHz
(3) f = 2500 MHz
(3) f = 100 kHz
(4) f = 300 kHz
(5) f = 1 MHz
(6) f = 3 MHz
Fig 7.
Third order intermodulation distortion as a
function of peak envelope power; typical
values
Fig 8.
Third-order intermodulation distortion as
function of frequency and tone spacing;
typical values
7.4 Bias module
The bias module information for the GaN HEMT amplifier is described in application note
AN11130.
8. Test information
8.1 Ruggedness in class-AB operation
The CLF1G0060-30 and CLF1G0060S-30 are capable of withstanding a load mismatch
corresponding to VSWR = 10 : 1 through all phases under the following conditions:
VDS = 50 V; PL = 30 W (pulsed RF), f = 3000 MHz.
8.2 Load pull impedance information
The measured load pull impedances are shown below. Impedance reference plane
defined at device leads. Measurements performed with Ampleon test fixtures. Test
temperature set at 25 C with a pulsed CW signal; tp = 100 s; = 10 %; RF performance
at VDS = 50 V; IDq = 50 mA.
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
10 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Table 12. Typical impedance
Typical values unless otherwise specified.
f
ZS
ZL (maximum PL(M))
ZL (maximum D)
(MHz)
()
()
()
2140
1.4 4j
14 + 5.4j
12.5 + 9.7j
2500
2.8 6j
10.5 + 2.5j
7.6 + 5.6j
2700
2.8 7.5j
10.7 + 1.3j
7.6 + 4.3j
3000
3.0 10j
9.1 + 3.5j
7.7 + 4.2j
3300
3.0 11.5j
9.4 + 1.2j
7.6 + 2.5j
3500
3.0 13j
9.5
7.2 + 1.35j
3700
3.5 14.4j
9.4 1.1j
7.3 0.05j
4000
3.7 20.3j
9.3 2.4j
7.7 1.2j
drain
gate
source
ZS
ZL
aaa-003694
Fig 9.
Definition of transistor impedance
ZS is the measured source pull impedance presented to the device. ZL is the measured
load pull impedance presented to the device.
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
11 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
8.3 Packaged S-parameter data
Table 13. S-parameter
Small signal; VDS = 50 V; IDq = 50 mA; ZS = ZL = 50 .
f
(MHz)
S11
S21
S12
S22
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
100
0.9302
76.396
44.515
135.22
0.016195
46.871
0.7376
43.407
200
0.87436
115.47
29.415
111.96
0.021253
25.279
0.55438
65.523
300
0.8537
134.97
21.02
98.876
0.022516
13.903
0.47582
77.762
400
0.8464
146.22
16.096
89.855
0.02261
6.6529
0.44954
86.181
500
0.8446
153.57
12.919
82.761
0.022198
1.4192
0.44849
92.826
600
0.84548
158.81
10.71
76.739
0.021498
2.6237
0.46041
98.482
700
0.84785
162.82
9.0883
71.392
0.020604
5.8352
0.47921
103.5
800
0.85112
166.05
7.8465
66.516
0.019567
8.375
0.50159
108.06
900
0.85494
168.77
6.8655
61.995
0.018424
10.302
0.5256
112.27
1000
0.85908
171.15
6.0713
57.758
0.017205
11.612
0.5501
116.19
1100
0.86338
173.27
5.4157
53.759
0.015936
12.256
0.57433
119.86
1200
0.86774
175.22
4.866
49.966
0.014644
12.138
0.59785
123.33
1300
0.87206
177.04
4.3993
46.356
0.01336
11.113
0.62038
126.6
1400
0.8763
178.75
3.9988
42.911
0.012117
8.9845
0.64176
129.7
1500
0.88039
179.61
3.6521
39.616
0.010958
5.505
0.66191
132.65
1600
0.88432
178.03
3.3496
36.459
0.0099386
0.40868
0.68081
135.46
1700
0.88806
176.49
3.0841
33.428
0.0091267
6.4893
0.69846
138.14
1800
0.8916
175
2.8497
30.514
0.0085991
15.099
0.7149
140.7
1900
0.89493
173.53
2.6416
27.709
0.008424
24.853
0.73019
143.15
2000
0.89806
172.09
2.4562
25.005
0.0086339
34.74
0.74438
145.5
2100
0.90098
170.67
2.2902
22.395
0.0092114
43.73
0.75755
147.76
2200
0.9037
169.26
2.1411
19.872
0.0101
51.208
0.76975
149.93
2300
0.90622
167.87
2.0067
17.429
0.011233
57.053
0.78106
152.02
2400
0.90856
166.48
1.8852
15.062
0.012549
61.439
0.79154
154.04
2500
0.91072
165.11
1.775
12.766
0.014001
64.635
0.80125
155.99
2600
0.91272
163.74
1.6748
10.534
0.015556
66.902
0.81025
157.88
2700
0.91455
162.37
1.5835
8.3639
0.017191
68.455
0.8186
159.71
2800
0.91623
161
1.5001
6.2502
0.01889
69.459
0.82634
161.49
2900
0.91777
159.63
1.4237
4.1894
0.020642
70.039
0.83353
163.22
3000
0.91917
158.27
1.3535
2.1779
0.022441
70.288
0.8402
164.91
3100
0.92044
156.89
1.289
0.21252
0.024281
70.278
0.84641
166.55
3200
0.9216
155.52
1.2296
1.71
0.02616
70.06
0.85218
168.16
3300
0.92264
154.14
1.1748
3.5925
0.028076
69.675
0.85755
169.73
3400
0.92357
152.75
1.1241
5.4376
0.030027
69.154
0.86255
171.27
3500
0.92441
151.35
1.0771
7.2479
0.032015
68.521
0.8672
172.78
3600
0.92515
149.94
1.0336
9.0257
0.034039
67.795
0.87155
174.26
3700
0.92579
148.53
0.99314
10.773
0.036099
66.989
0.87559
175.72
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
12 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Table 13. S-parameter …continued
Small signal; VDS = 50 V; IDq = 50 mA; ZS = ZL = 50 .
f
(MHz)
S11
S21
S12
S22
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
Magnitude
(ratio)
Angle
(degree)
3800
0.92635
147.1
0.95551
12.493
0.038198
66.115
0.87937
177.15
3900
0.92683
145.65
0.92046
14.186
0.040336
65.183
0.8829
178.57
4000
0.92723
144.2
0.88777
15.855
0.042516
64.2
0.88619
179.97
4100
0.92756
142.73
0.85724
17.501
0.044737
63.171
0.88927
178.65
4200
0.92781
141.24
0.82871
19.126
0.047003
62.101
0.89215
177.28
4300
0.928
139.73
0.802
20.732
0.049315
60.994
0.89484
175.93
4400
0.92812
138.2
0.77698
22.32
0.051676
59.853
0.89735
174.58
4500
0.92818
136.66
0.75351
23.891
0.054087
58.68
0.8997
173.25
4600
0.92818
135.09
0.73149
25.447
0.05655
57.477
0.9019
171.92
4700
0.92812
133.5
0.71079
26.99
0.059068
56.245
0.90396
170.6
4800
0.928
131.89
0.69133
28.519
0.061644
54.986
0.90588
169.28
4900
0.92783
130.25
0.67301
30.038
0.064279
53.699
0.90767
167.97
5000
0.92761
128.59
0.65576
31.546
0.066975
52.387
0.90935
166.66
5100
0.92734
126.9
0.63949
33.046
0.069736
51.047
0.91092
165.35
5200
0.92701
125.17
0.62415
34.537
0.072563
49.682
0.91238
164.04
5300
0.92664
123.42
0.60968
36.022
0.075459
48.291
0.91375
162.73
5400
0.92622
121.64
0.596
37.501
0.078426
46.874
0.91502
161.42
5500
0.92576
119.83
0.58307
38.975
0.081467
45.43
0.9162
160.1
5600
0.92525
117.98
0.57085
40.446
0.084583
43.959
0.9173
158.78
5700
0.9247
116.1
0.55929
41.914
0.087778
42.461
0.91832
157.45
5800
0.92411
114.18
0.54834
43.38
0.091053
40.935
0.91927
156.12
5900
0.92348
112.22
0.53797
44.846
0.094411
39.381
0.92014
154.77
6000
0.92282
110.23
0.52814
46.311
0.097853
37.797
0.92095
153.42
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
13 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
9. Package outline
Flanged ceramic package; 2 mounting holes; 2 leads
SOT1227A
D
A
F
D1
w1
A
B
U1
B
q
c
C
w1
A
B
1
H
E1
p
U2
E
3
2
A
w1
b
w1
A
B
C
Q
w2
0
scale
A
b
c
D
D1
max 3.68
nom
min 2.84
1.40
0.15
5.18
5.21
1.14
0.08
4.98
max 0.145
inches nom
min 0.112
0.055
0.006
0.204 0.205 0.164 0.165 0.045 0.340 0.105 0.067
mm
B
5 mm
Dimensions
Unit(1)
A
E
E1
F
4.17 4.19 1.14
H
p
Q
8.64
2.67
1.70
q
U1
U2
w1
14.10 4.19
9.53
4.95
3.96 3.94 0.89
7.62
2.41
1.45
0.25 0.380
13.84 3.94
0.555 0.165
0.375
0.045
0.003
0.196 0.195 0.156 0.155 0.035 0.300 0.095 0.057
0.01 0.015
0.545 0.155
Note
1. Millimeter dimensions are derived from the original inch dimensions.
Outline
version
References
IEC
JEDEC
w2
JEITA
sot1227a_po
European
projection
Issue date
12-06-08
13-10-14
SOT1227A
Fig 10. Package outline SOT1227A
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
14 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Earless Flanged ceramic package; 2 leads
SOT1227B
D
A
F
3
U1
w1
A
B
D1
D
c
w1
A
B
1
H
E1
U2
E
2
A
b
w2
B
Q
w2
0
scale
A
b
c
D
D1
max 3.68
nom
min 2.84
1.40
0.15
5.18
5.21
1.14
0.08
4.98
4.95
max 0.145
inches nom
min 0.112
0.055
0.006
0.204 0.205 0.164 0.165 0.042 0.340 0.067 0.205 0.165
0.045
0.003
0.196 0.195 0.156 0.155 0.038 0.300 0.057 0.195 0.155
mm
B
5 mm
Dimensions
Unit(1)
A
F
H
Q
U1
U2
4.17 4.19 1.07
8.64
1.70
5.21
4.19
3.96 3.94 0.97
7.62
1.45
4.95
3.94
E
E1
w1
w2
0.25 0.380
0.01 0.015
Note
1. Millimeter dimensions are derived from the original inch dimensions.
Outline
version
References
IEC
JEDEC
JEITA
sot1227b_po
European
projection
Issue date
12-06-08
13-10-15
SOT1227B
Fig 11. Package outline SOT1227B
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
15 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
10. Handling information
10.1 ESD Sensitivity
Table 14.
ESD sensitivity
ESD model
Class
Human Body Model (HBM); According JEDEC standard JESD22-A114F
1B [1]
[1]
Classification 1B is granted to any part that passes after exposure to an ESD pulse of 500 V, but fails after
exposure to an ESD pulse of 1000 V.
11. Abbreviations
Table 15.
Abbreviations
Acronym
Description
AWG
American Wire Gauge
CW
Continuous Wave
EMC
ElectroMagnetic Compatibility
ESD
ElectroStatic Discharge
GaN
Gallium Nitride
HEMT
High Electron Mobility Transistor
SMD
Surface Mounted Device
VSWR
Voltage Standing-Wave Ratio
WiMAX
Worldwide Interoperability for Microwave Access
12. Revision history
Table 16.
Revision history
Document ID
Release date Data sheet status
CLF1G0060-30_1G0060S-30 v.7 20180205
Modifications:
•
•
Product data sheet
Change notice Supersedes
-
CLF1G0060-30_1G0060S-30 v.6
Table 9 on page 4: L1 remark updated
Figure 2 on page 6: L1 value updated
CLF1G0060-30_1G0060S-30 v.6 20160218
Product data sheet
CLF1G0060-30_1G0060S-30#5
-
CLF1G0060-30_1G0060S-30#5
20150901
Objective data sheet -
CLF1G0060-30_1G0060S-30 v.4
CLF1G0060-30_1G0060S-30 v.4 20130620
Objective data sheet -
CLF1G0060-30_1G0060S-30 v.3
CLF1G0060-30_1G0060S-30 v.3 20130327
Objective data sheet -
CLF1G0060-30_1G0060S-30 v.2
CLF1G0060-30_1G0060S-30 v.2 20130129
Objective data sheet -
CLF1G0060-30_1G0060S-30 v.1
CLF1G0060-30_1G0060S-30 v.1 20121008
Objective data sheet -
-
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
16 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
13. Legal information
13.1 Data sheet status
Document status[1][2]
Product status[3]
Objective [short] data sheet
Development
This document contains data from the objective specification for product development.
Preliminary [short] data sheet
Qualification
This document contains data from the preliminary specification.
Product [short] data sheet
Production
This document contains the product specification.
Definition
[1]
Please consult the most recently issued document before initiating or completing a design.
[2]
The term ‘short data sheet’ is explained in section “Definitions”.
[3]
The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status
information is available on the Internet at URL http://www.ampleon.com.
13.2 Definitions
Draft — The document is a draft version only. The content is still under
internal review and subject to formal approval, which may result in
modifications or additions. Ampleon does not give any representations or
warranties as to the accuracy or completeness of information included herein
and shall have no liability for the consequences of use of such information.
Short data sheet — A short data sheet is an extract from a full data sheet
with the same product type number(s) and title. A short data sheet is intended
for quick reference only and should not be relied upon to contain detailed and
full information. For detailed and full information see the relevant full data
sheet, which is available on request via the local Ampleon sales office. In
case of any inconsistency or conflict with the short data sheet, the full data
sheet shall prevail.
Product specification — The information and data provided in a Product
data sheet shall define the specification of the product as agreed between
Ampleon and its customer, unless Ampleon and customer have explicitly
agreed otherwise in writing. In no event however, shall an agreement be valid
in which the Ampleon product is deemed to offer functions and qualities
beyond those described in the Product data sheet.
13.3 Disclaimers
Limited warranty and liability — Information in this document is believed to
be accurate and reliable. However, Ampleon does not give any
representations or warranties, expressed or implied, as to the accuracy or
completeness of such information and shall have no liability for the
consequences of use of such information. Ampleon takes no responsibility for
the content in this document if provided by an information source outside of
Ampleon.
In no event shall Ampleon be liable for any indirect, incidental, punitive,
special or consequential damages (including - without limitation - lost profits,
lost savings, business interruption, costs related to the removal or
replacement of any products or rework charges) whether or not such
damages are based on tort (including negligence), warranty, breach of
contract or any other legal theory.
Notwithstanding any damages that customer might incur for any reason
whatsoever, Ampleon’s aggregate and cumulative liability towards customer
for the products described herein shall be limited in accordance with the
Terms and conditions of commercial sale of Ampleon.
Right to make changes — Ampleon reserves the right to make changes to
information published in this document, including without limitation
specifications and product descriptions, at any time and without notice. This
document supersedes and replaces all information supplied prior to the
publication hereof.
Suitability for use — Ampleon products are not designed, authorized or
warranted to be suitable for use in life support, life-critical or safety-critical
systems or equipment, nor in applications where failure or malfunction of an
CLF1G0060-30_1G0060S-30
Product data sheet
Ampleon product can reasonably be expected to result in personal injury,
death or severe property or environmental damage. Ampleon and its
suppliers accept no liability for inclusion and/or use of Ampleon products in
such equipment or applications and therefore such inclusion and/or use is at
the customer’s own risk.
Applications — Applications that are described herein for any of these
products are for illustrative purposes only. Ampleon makes no representation
or warranty that such applications will be suitable for the specified use without
further testing or modification.
Customers are responsible for the design and operation of their applications
and products using Ampleon products, and Ampleon accepts no liability for
any assistance with applications or customer product design. It is customer’s
sole responsibility to determine whether the Ampleon product is suitable and
fit for the customer’s applications and products planned, as well as for the
planned application and use of customer’s third party customer(s). Customers
should provide appropriate design and operating safeguards to minimize the
risks associated with their applications and products.
Ampleon does not accept any liability related to any default, damage, costs or
problem which is based on any weakness or default in the customer’s
applications or products, or the application or use by customer’s third party
customer(s). Customer is responsible for doing all necessary testing for the
customer’s applications and products using Ampleon products in order to
avoid a default of the applications and the products or of the application or
use by customer’s third party customer(s). Ampleon does not accept any
liability in this respect.
Limiting values — Stress above one or more limiting values (as defined in
the Absolute Maximum Ratings System of IEC 60134) will cause permanent
damage to the device. Limiting values are stress ratings only and (proper)
operation of the device at these or any other conditions above those given in
the Recommended operating conditions section (if present) or the
Characteristics sections of this document is not warranted. Constant or
repeated exposure to limiting values will permanently and irreversibly affect
the quality and reliability of the device.
Terms and conditions of commercial sale — Ampleon products are sold
subject to the general terms and conditions of commercial sale, as published
at http://www.ampleon.com/terms, unless otherwise agreed in a valid written
individual agreement. In case an individual agreement is concluded only the
terms and conditions of the respective agreement shall apply. Ampleon
hereby expressly objects to applying the customer’s general terms and
conditions with regard to the purchase of Ampleon products by customer.
No offer to sell or license — Nothing in this document may be interpreted or
construed as an offer to sell products that is open for acceptance or the grant,
conveyance or implication of any license under any copyrights, patents or
other industrial or intellectual property rights.
Export control — This document as well as the item(s) described herein
may be subject to export control regulations. Export might require a prior
authorization from competent authorities.
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
17 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
Non-automotive qualified products — Unless this data sheet expressly
states that this specific Ampleon product is automotive qualified, the product
is not suitable for automotive use. It is neither qualified nor tested in
accordance with automotive testing or application requirements. Ampleon
accepts no liability for inclusion and/or use of non-automotive qualified
products in automotive equipment or applications.
In the event that customer uses the product for design-in and use in
automotive applications to automotive specifications and standards, customer
(a) shall use the product without Ampleon’s warranty of the product for such
automotive applications, use and specifications, and (b) whenever customer
uses the product for automotive applications beyond Ampleon’s specifications
such use shall be solely at customer’s own risk, and (c) customer fully
indemnifies Ampleon for any liability, damages or failed product claims
resulting from customer design and use of the product for automotive
applications beyond Ampleon’s standard warranty and Ampleon’s product
specifications.
Translations — A non-English (translated) version of a document is for
reference only. The English version shall prevail in case of any discrepancy
between the translated and English versions.
13.4 Trademarks
Notice: All referenced brands, product names, service names and trademarks
are the property of their respective owners.
Any reference or use of any ‘NXP’ trademark in this document or in or on the
surface of Ampleon products does not result in any claim, liability or
entitlement vis-à-vis the owner of this trademark. Ampleon is no longer part of
the NXP group of companies and any reference to or use of the ‘NXP’
trademarks will be replaced by reference to or use of Ampleon’s own
trademarks.
14. Contact information
For more information, please visit: http://www.ampleon.com
For sales office addresses, please visit: http://www.ampleon.com/sales
CLF1G0060-30_1G0060S-30
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 5 February 2018
© Ampleon Netherlands B.V. 2018. All rights reserved.
18 of 19
CLF1G0060-30; CLF1G0060S-30
Broadband RF power GaN HEMT
15. Contents
1
1.1
1.2
1.3
2
3
4
5
6
7
7.1
7.2
7.3
7.3.1
7.3.2
7.3.3
7.4
8
8.1
8.2
8.3
9
10
10.1
11
12
13
13.1
13.2
13.3
13.4
14
15
Product profile . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General description . . . . . . . . . . . . . . . . . . . . . 1
Features and benefits . . . . . . . . . . . . . . . . . . . . 2
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Pinning information . . . . . . . . . . . . . . . . . . . . . . 2
Ordering information . . . . . . . . . . . . . . . . . . . . . 2
Limiting values. . . . . . . . . . . . . . . . . . . . . . . . . . 3
Thermal characteristics . . . . . . . . . . . . . . . . . . 3
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Application information. . . . . . . . . . . . . . . . . . . 4
Demo circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Application test results . . . . . . . . . . . . . . . . . . . 7
Graphical data . . . . . . . . . . . . . . . . . . . . . . . . . 8
1-Tone CW RF performance. . . . . . . . . . . . . . . 8
1-Tone pulsed RF performance . . . . . . . . . . . . 9
2-Tone CW performance . . . . . . . . . . . . . . . . 10
Bias module . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Test information . . . . . . . . . . . . . . . . . . . . . . . . 10
Ruggedness in class-AB operation . . . . . . . . 10
Load pull impedance information . . . . . . . . . . 10
Packaged S-parameter data. . . . . . . . . . . . . . 12
Package outline . . . . . . . . . . . . . . . . . . . . . . . . 14
Handling information. . . . . . . . . . . . . . . . . . . . 16
ESD Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . 16
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Revision history . . . . . . . . . . . . . . . . . . . . . . . . 16
Legal information. . . . . . . . . . . . . . . . . . . . . . . 17
Data sheet status . . . . . . . . . . . . . . . . . . . . . . 17
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Contact information. . . . . . . . . . . . . . . . . . . . . 18
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Please be aware that important notices concerning this document and the product(s)
described herein, have been included in section ‘Legal information’.
© Ampleon Netherlands B.V. 2018.
All rights reserved.
For more information, please visit: http://www.ampleon.com
For sales office addresses, please visit: http://www.ampleon.com/sales
Date of release: 5 February 2018
Document identifier: CLF1G0060-30_1G0060S-30