M12 D Code Crimp Assembly Instruction
5 Easy Steps Make Your Field Installation Secured And Reliable !!!
1
1
2
5
Prepare components 1 Connector、 2 Terminals、
3 Clamp Ring、 4 Seal、 5 Sealing Nut.
3
2
4
Assemble all components in the order( A B C D ). Make
sure 1 Connector & 2 Terminals、 4 Seal、 5 Sealing Nut been
assembled properly (See figure A 、 C 、 D ).
1
3
4
5
2
5
Follow the order from 5 to 3 and put components through
cable accordingly, no need to assemble here.
A
handling feedback
while assembling,
and pull cable to
make sure.
Installation
Side
3
4
X
C
A Audio and
4
Seal
D
4
X
D
Too Loose
5
V
3
C
B
V 4~6 kgf
Seal
5
4
Follow suggested stripping length of outer jacket (L3) and
insulation (L1). And fold the braid backward (L2).
Dimension
L1
4mm ± 1
L2
4mm ± 1
L3
19mm ± 1
Tips
A
5
For Reworking, press the latches on the housing of 1 Connector
(pointed by red arrows), and pull cable to disassemble (See
figure A ). Disassemble 2 Terminals from the housing and put
housing back into 1 Connector (See figure B ).
B
Use crimping tool to crimp all the 2 Terminals with wires.
2
Housing
2
Housing
1
1