PCD100-265-B-2R420-200 数据手册
Process and temperature meters
PCD100 series
The PCD100 digital panel meters are one of the most versatile on the market, and
are used in a wide variety of process and temperature applications. The PCD100
can be field programmed to accept common process voltage (1-5V, ± 10V) and
current (0-20 mA, 4-20 mA) inputs, 100 Ω RTDs, and the four most common
thermocouples. One of the PCD100’s most useful features is its ability to provide 24
VDC to power the transmitter’s 4-20 mA signal. There are two power options: 85265 VAC or 12-36 VDC. The meter can be programmed via front panel or remotely.
Front Panel NEMA 4X, IP65 Rated
PCD100 series
The display is four full digits, meaning it can
display numbers up to 9999, an advantage
over most digital panel meters. The PCD100
can display type K thermocouples to 2300°F
and 4-20 mA signals up to 9,999.
The meter is supplied with two alarm points
that include front panel red LEDs to indicate
alarm conditions, making it particularly
useful for alarm applications that require
visual-only indication.
12-36 VDC
Options installed
PCD100-265-B-N-0
PCD100-24-B-N-0
none
PCD100-265-B-N-200
PCD100-265-B-2R-0
24 VDC transmitter supply
PCD100-24-B-2R-0
• 4-20 mA, ±10V, TC & RTD
field-selectable inputs
• Options for 2 relays,
isolated 4-20 mA output,
and 24 VDC transmitter
power supplies
2 relays
• External contacts for
remote button operation
2 relays + 24 VDC transmitter
supply
PCD100-265-B-2R-200
PCD100-265-B-420-0
• NEMA 4X, IP65 front panel
• Includes PC-based
programming and
monitoring software
Ordering information
85-265 VAC
Key features
PCD100-24-B-420-0
4-20 mA output
PCD100-265-B-420-200
4-20 mA output + 24 VDC
transmitter supply
PCD100-265-B-420-240
4-20 mA output + dual 24 VDC
transmitter supplies
PCD100-24-B-2R420-0
PCD100-265-B-2R420-200
Certifications
2 relays + 4-20 mA output
2 relays + 4-20 mA output + 24
VDC transmitter supply
Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release.
Wilcoxon Sensing Technologies
An Amphenol Company
99388 Rev.A 08/20
8435 Progress Drive
Frederick, MD 21701
USA
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
buy.wilcoxon.com
www.wilcoxon.com
1
Process and temperature meters
PCD100 series
DIMENSIONS
1.76” [44.7 mm]
2.50”
[63.5 mm]
2.45”
[62.2 mm]
3.61”
[91.7 mm]
0.59”
[15.0 mm]
3.20” [81.3 mm]
3.60” [91.4 mm]
4.68” [118.9 mm]
Side view
Top view
SPECIFICATIONS
GENERAL
Display
1.2” (30.5 mm) height, 4 digits, red LED
Display intensity
Eight levels, user-selectable
Front panel
NEMA 4X, IP65 (panel gasket provided)
Programming methods
Four front panel buttons, cloning with Copy feature, PC with MeterView software, Modbus registers
Power options
85-265 VAC, 50/60 Hz;
90-265 VDC, 20 W max or 12-36 VDC;
12-24 VAC, 6 W max
Required fuse
UL recognized, 5 A max, slow-blow; up to 6 meters may share one fuse
Isolation
4 kV input/output-to-power line;
500 V input-to-output or output to 24 VDC supplies;
-2R420 models only: 100 V output-to-24 VDC supply
Temperature range
Operating: -40° to 65°C
Storage: -40° to 85°C
Relative humidity
0 to 90% non-condensing
Connections
Power & signal: removable screw terminal blocks accept 12 to 22 AWG
Serial: RJ11 header, standard on all meters
Enclosure
1/8 DIN, high impact plastic, 94V-0, color: gray
Weight
269 grams (9.5 oz) (including options)
Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release.
Wilcoxon Sensing Technologies
An Amphenol Company
99388 Rev.A 08/20
8435 Progress Drive
Frederick, MD 21701
USA
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
buy.wilcoxon.com
www.wilcoxon.com
2
Process and temperature meters
PCD100 series
SPECIFICATIONS
PROCESS INPUTS
Inputs
0-20 mA, 4-20 mA, 1-5 V, ± 10V
Transmitter supply
P1
P1 & P2
Isolated, one or two transmitter supplies
24 VDC ± 10% @ 200 mA max (-200 models)
24 VDC ± 10% @ 200 mA and 40 mA max (-240 models)
Accuracy
±0.05% FS ±1 count; square root: ±0.1% FS ± 2 counts
Function
linear or square root
Calibration range
user programmable over entire range of meter
Input impedance
Voltage range: >1 MΩ
Current range: 50-100 Ω, varies with resettable fuse impedance
Input overload
protected by automatically resettable fuse
Temperature drift
see table 1
TEMPERATURE INPUTS
Inputs
Factory-calibrated, field selectable, type J, K, T, or E (see table 2)
Resolution
1°; type T TC & RTD: 1° or 0.1°
Cold junction reference
automatic
Temperature drift
± 2°C maximum
Offset adjustment
programmable to ±19.9° (allows user to apply an offset value to the temperature being displayed)
Input impedance
>100 kΩ
RELAYS
2 Form C (SPDT); rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load; 1/14 HP (=50 watts) @
125/250 VAC for inductive loads
Rating
Relay operation
Time delay
0 to 199 seconds, on and off delays; programmable
Table 1: Temperature drift
Table 2: Temperature input types
Input
0 to 65°C ambient
-40 to 0°C ambient
Current
±0.20% FS (50 PPM/°C)
±0.80% FS
Voltage
±0.02% FS (1.7 PPM/°C)
±0.06% FS
Type
Range
Acc. (0 to 65°C)
Acc. (-40 to 0°C)
Resolution
J
-58° to 1382°F
-50°C to 750°C
± 2°F
± 1°C
± 5°F
± 3°C
1°
K
-58° to 2300°F
-50°C to 1260°C
± 2°F
± 1°C
± 4°F
± 2°C
1°
T
-292° to 700°F
-180°C to 371°C
± 2°F
± 1°C
± 13°F
± 7°C
1° or 0.1°
E
-58° to 1700°F
-50°C to 927°C
± 2°F
± 1°C
± 11°F
± 6°C
1°
RTD
-328° to 1382°F
-200°C to 750°C
± 1°F
± 1°C
± 5°F
± 3°C
1° or 0.1°
Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release.
Wilcoxon Sensing Technologies
An Amphenol Company
99388 Rev.A 08/20
8435 Progress Drive
Frederick, MD 21701
USA
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
buy.wilcoxon.com
www.wilcoxon.com
3
Process and temperature meters
PCD100 series
SPECIFICATIONS
SERIAL COMMUNICATIONS
Protocol
Modbus RTU
Meter address
PDC protocol: 0 to 99
Modbus protocol: 1 to 247
Baud rate
300 to 19,200 bps
Transmit time delay
Programmable, 0 to 199 ms
Data
8 bit (1 start bit, 1 stop bit)
Parity
None (1 or 2 stop bits), even, or odd
Turn around delay
< 2 ms (fixed)
ISOLATED 4-20 mA TRANSMITTER OUTPUT
Scaling range
1.00 to 23.00 mA; reverse scaling allowed
Accuracy
Temperature drift
±0.1% FS ±0.004 mA
50 PPM/°C
1
Isolation
500 V input-to-output or output-to-24 VDC supplies;
4 kV output-to-power line;
100 V output-to-24 VDC supply (model PCD100-265-B-2R420-200 only)
External power
35 VDC maximum
Output loop resistance
see table 3
EXTERNAL BUTTON CONTACTS
Number
Four
Function
Remote operation of front-panel buttons
Open state
+5 VDC open contact on button input terminals
Closed state
Closed contact button input terminal to common/ground, active low 0 to 0.4 VDC
Notes: 1 Analog output drift is separate from input drift.
Table 3: Output loop resistance
Power supply
Minimum
Maximum
24 VDC
10 Ω
700 Ω
35 VDC (external)
100Ω
1200 Ω
Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release.