0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PCD200-24-B-4R420-140

PCD200-24-B-4R420-140

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

  • 描述:

    过程多用表 LED - 红色字符 显示 面板安装

  • 数据手册
  • 价格&库存
PCD200-24-B-4R420-140 数据手册
Dual-input process meters PCD200 series The PCD200 series are 1/8 DIN digital panel meters that accepts two inputs of either a process current (4-20 mA) or process voltage (0-5V, 1-5V, ±10V) signal. It displays these signals on a dual line, 6-digit display that is available with an optional Sunbright® sunlight readable LEDs. The meter can be customized such that these two inputs are displayed in a variety of ways, including both at the same time with tags or the result of math functions performed on one or both of the inputs. The PCD200 features CE marking, a NEMA 4X front, and AC or DC power options, and can be equipped with up to four internal relays, a 4-20 mA analog output, and Modbus® serial communications. PCD200 meters can be programmed via the front panel pushbuttons or included PC-based software. UV resistant SunBright sunlight readable models Rugged NEMA 4X / IP65 front panel Key features User configurable math function result Large 0.6” digits Dual-line 6 character display Programmable function keys User configurable custom tag Alarm status indicators • Dual input process meter with math functions • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ± 10 V inputs • SunBright display models for outdoor applications • NEMA 4X, IP65 front panel Ordering information SunBright display Standard 85-265 VAC models 12-24 VDC models Options installed PCD200-265-B-N-200 PCD200-24-B-N-100 none PCD200-265-B-2R-200 PCD200-24-B-2R-100 2 relays PCD200-265-B-420-240 PCD200-24-B-420-140 4-20 mA output PCD200-265-B-4R-200 PCD200-24-B-4R-100 4 relays PCD200-265-B-2R420-240 PCD200-24-B-2R420-140 2 relays + 4-20 mA output PCD200-265-B-4R420-240 PCD200-24-B-4R420-140 4 relays + 4-20 mA output PCD200-265-SB-N PCD200-24-SB-N-100 none PCD200-265-SB-2R PCD200-24-SB-2R-100 2 relays PCD200-265-SB-420 PCD200-24-SB-420-140 4-20 mA output PCD200-265-SB-4R-200 PCD200-24-SB-4R-100 4 relays PCD200-265-SB-2R420-240 PCD200-24-SB-2R420-140 2 relays + 4-20 mA output PCD200-265-SB-4R420-240 PCD200-24-SB-4R420-140 4 relays + 4-20 mA output • Input power options include 85-265 VAC or 12-24 VDC • 2 or 4 relays + isolated 4-20 mA output options • Includes PC-based programming and monitoring software Certifications Accessories available. NOTE: A 24 V transmitter power supply is standard and may be used to power the inputs. Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies An Amphenol Company 99389 Rev.A 08/20 8435 Progress Drive Frederick, MD 21701 USA Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com 1 Dual-input process meters PCD200 series DISPLAY FEATURES Easy to use, customizable displays The dual-line display makes the PCD200 easy to set up and program, and all configuration can be done via the front panel. PCD200 series meters have an upper and lower display, each a full 6 digits (-999999 to 999999). The displays can be set up to read input channels (A or B), math function channel C, toggle between A & B, B & C, A & C, A & B & C, toggle between channels A, B, or C & units, the max/min of any of the channels (including math channel C), set points, gross, or net & gross values of channel A or B, or the Modbus input. This allows the meter to show the most relevant variables for the application. Math function & tag Input channels A & B Alternation display Certain options alternate the display information. A single display can show input variable information as well as that channel’s unit or tag. Input and math function channels, gross and net values, and select inputs and the math results may also alternate on a single display. Lower display alternating input channels A & B Standard LED and SunBright LED display models PCD200 meters feature ultra-bright LED displays. Both standard and SunBright models perform well in both indoor and outdoor settings where visibility may be impaired by smoke, fog, dust, or distance. The UV-resistant SunBright display option is even readable in sunlight and ideal for use in outdoor applications. DIMENSIONS Optional connectors installed 1.76” [44.5 mm] 2.45” [62.2 mm] 0.59” [15.0 mm] 4.17” [106 mm] 3.61” [91.5 mm] 4.77” [121.2 mm] 5.05” [128.3 mm] 6” [152 mm] clearance 4.68” [118.9 mm] Side view Top view Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies An Amphenol Company 99389 Rev.A 08/20 8435 Progress Drive Frederick, MD 21701 USA Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com 2 Dual-input process meters PCD200 series SPECIFICATIONS GENERAL Display Upper display: 0.60: (15mm) high, lower display: 0.46” (12 mm) high, 6 digits each, red LEDs Front panel NEMA 4X, IP65 Programming methods Four front panel buttons, digit inputs, PC with MeterView software, Modbus registers, or cloning using Copy function Power options 85-265 VAC, 50/60 Hz; 90-265 VDC, 20 W max; optional model with 12-24 VDC ±10%, 15 W max Required fuse UL recognized, 5 A max, slow-blow; up to 6 meters may share one 5 A fuse Isolated transmitter power supply Terminals P+ & P-: 24 VDC ± 10%. Internally selectable jumper for 24, 10, or 5 VDC supply. 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply. Isolation 4 kV input/output-to-power line; 500 V input-to-output or output or output-to-P+ supply Temperature range: Operating Storage -40° to 65°C -40° to 85°C Relative humidity 0 to 90% non-condensing Connections Removable screw terminal blocks accept 12 to 22 AWG, RJ45 for external relays, digital I/O, and serial communmication adapters Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black Mounting 1/8 DIN panel cutout required: 3.622” x 1.772” Tightening torque Screw terminal connectors: 5 lb-in (0.56 Nm) Weight 269 grams (9.5 oz) USB connection Compatibility: USB 2.0 Standard; compliant connector type: Micro-B receptacle; cable: USB A male to Micro-B cable; power: USB port DUAL PROCESS INPUT Inputs Two non-isolated inputs, separately field selectable: 0-20 mA, 4-20 mA, 10 V (0-5, 1-5, 0-10 V), Modbus PV (Slave) Accuracy ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10100% of calibrated span Temperature drift: 0 to 65°C ambient -40 to 0°C ambient 0.005% of calibrated span/°C max 0.01% of calibrated span/°C max Signal input conditioning linear, square root, programmable exponent, or round horizontal tank volume calculation Calibration range 4-20 mA: minimum span input 1 & input 2: 0.15 mA ±10 V: minimum span input 1 & 2: 0.10 V Input impedance: Voltage ranges Current ranges >500 kΩ 50-100 Ω, varies with resettable fuse impedance Input overload current input protected by resettable fuse, 30 VDC max1 Notes: 1 Fuse resets automatically after fault is removed. Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies An Amphenol Company 99389 Rev.A 08/20 8435 Progress Drive Frederick, MD 21701 USA Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com 3 Dual-input process meters PCD200 series SPECIFICATIONS RELAYS Rating 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HT (approx. 50 W) @ 125/250 VAC for inductive loads Relay operation automatic (non-latching); latching (requires manual acknowledge); sampling (based on time); pump alteration control (2 to 8 relays); Off (disable unused relays and enable interlock feature, manual on/off control mode) Time delay 0 to 999.9 seconds, on and off relay time delays; programmable & independent for each relay SERIAL COMMUNICATIONS Protocol Modbus RTU Meter address/Slave ID 1 to 247 Baud rate 300 to 19,200 bps Transmit time delay Programmable between 0 and 199 ms Data 8 bit (1 start bit, 1 or 2 stop bits) Parity Even, odd or none with 1 or 2 stop bits Byte-to-byte timeout 0.01 - 2.54 seconds Turn around delay < 2 ms (fixed) ISOLATED 4-20 mA TRANSMITTER OUTPUT Output source Process channel A, B, or C, max or min for channel A, B, or highest and lowest max or min of A and B, set points 1-8, Modbus input, or manual control mode Scaling range 1.000 to 23.000 mA for any display range Accuracy ±0.1% of span ±0.004 mA Temperature drift2: 0 to 65°C ambient -40 to 0°C ambient 0.4 µA/°C max 0.8 µA/°C max Isolated transmitter power supply Terminals I+ & R: 24 VDC ±10%, isolated from the input at >500 V; may be used to power the 4-20 mA output or other devices; all models rated @ 40 mA max External loop power supply 35 VDC maximum Output loop resistance see Table 1 Notes: Analog output drift is separate from input drift. 2 Table 1: Output loop resistance Power supply Minimum Maximum 24 VDC 10 Ω 700 Ω 35 VDC (external) 100 Ω 1200 Ω Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies An Amphenol Company 99389 Rev.A 08/20 8435 Progress Drive Frederick, MD 21701 USA Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com buy.wilcoxon.com www.wilcoxon.com 4
PCD200-24-B-4R420-140 价格&库存

很抱歉,暂时无法提供与“PCD200-24-B-4R420-140”相匹配的价格&库存,您可以联系我们找货

免费人工找货