ROHS
compliant
N & BZ
RJF TV
Ethernet Connection System for Harsh Environment
RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT,
100 BaseTx or 1000 BaseT networks in harsh environments.
With the patented RJStop system you can use a standard RJ45 cordset in a
metallic plug which will protect it from shocks, dust and fluids.
No hazardous on-field cabling and grounding!
Applications
n
Data Acquisition and Transmission in harsh
environment
n
Railways
n
Radars
n
Shelters
n
Battlefield Communication
n
Systems
n
Navy
Data Transmission
10 BaseT, 100 BaseTX and 1000 BaseT networks
Cat 5e per TIA/EIA 568B and ClassD per ISO/IEC
11801
Part Number Code
MAIN CHARACTERISTICS
n
Sealed against fluids and dusts (IP68)
n
Shock, Vibration and Traction resistant
n
No cabling operation in field and no tools required
n
Mechanical Coding / Polarization (4 positions)
n
Improved EMI protection
n Tri Start Thread coupling mechanism (MIL-DTL-38999 series III type)
with anti-decoupling device
n Robust metallic shells
n RJ45 cordset retention in the plug: 100 N in the axis
n Mating cycles: 500 min
n
Compatible with cable diameter from 5,5 mm [0.216 in] to 13 mm [0.512 in]
Environmental Protection
n
Sealing: IP68
n
Salt Spray:
48 h with Aluminium shell - Nickel plating
> 500 h with Aluminium shell - Olive Dran Cadmium plating
1000h with Marine bronze shell
n
Fire Retardant / Low Smoke: UL94 V0 and NF F 16 101 & 16 102
n
Vibrations: 10 – 500 Hz, 10 g, 3 axes: no discontinuity > 10 nano s.
n
Compounded versions tested per NAS 1599 (5-3000 Hz, 20g, 12h)
n
Shocks: IK06: weight of 250 g drop from 40 cm [15.75 in] onto connectors (mated pair)
n
Humidity: 21 days, 43°C, 98% humidity
n
Thermal Shock: 5 cycles at - 40°C / +100°C
n
Temperature Range: - 40°C / +85°C
RJF TV
Series
RJ Field TV
RJF TV
2
2
G
03 100 BTX
Shell Type
6:
Plug with Plastic gland
6M:
Plug with Metal gland
2: Square Flange Receptacle
2PE: Square Flange Receptacle, IP68 backshell, Plastic gland
2PEM: Square Flange Receptacle, IP68 backshell, Metal gland
7:
Jam Nut Receptacle
7PE:
Jam Nut Receptacle, IP68 backshell, Plastic gland
7PEM:
Jam Nut Receptacle, IP68 backshell, Metal gland
2SA, 7SA: Transversally sealed receptacle (unmated) see page 22
Amphenol
Back Terminations (Receptacles only)
1: Female RJ45
1RA:
Right Angle Female RJ45
2:
RJ45 Cordset
Shells material & Finish
N: Aluminium shell - nickel plating (receptacle inserts are metallized) - ROHS compliant
G: Aluminium shell - olive drab cadmium plating (receptacle inserts are metallized)
BZ:
Marine bronze shell (receptacle inserts are metallized) - ROHS compliant
Cordset Length (type 2 back termination only)
03 100 BTX: 0.3m [11.81 inches]
05 100 BTX: 0.5m 19.68 inches]
10 100 BTX: 1m [39.37 inches]
15 100 BTX: 1.5m [59.05 inches]
00:
8 tinned holes at the rear of the PCB to solder the cable
Remark: Cabling configuration: 100 BTX = 568B (Ethernet specification)
Examples:
14
- Olive Drab Cadmium plug with plastic gland: RJF TV 6G
- Olive Drab Cadmium Jam Nut Receptacle, female RJ45 back termination: RJF TV 71G
- Nickel Jam Nut Receptacle, 1,5 m 100 BTX cordset back termination: RJF TV 72N 15 100BTX
- Olive Drab Cadmium in line Square Flange Recept., 0,3 m 100 BTX cordset back termination: RJF TV 2PE 2 G 03 100BTX
- Nickel Jam Nut Receptacle Solder termination 8 tinned holes: RJF TV 22 N 00
informations & contacts: www.rjfield.com • contact@rjfield.com
Plug:
n
Shell type 6 with Plastic or Metal Gland
RJF TV 6 X
Receptacles:
n Square flange receptacle • 4 mounting holes: Shell type 2
RJFTV 21 X (Straight Female RJ45)
RJFTV 21 RA X (Right Angle Female RJ45)
Panel Drilling
n
Jam nut receptacle • Hexagonal Nut mounting: Shell type 7
RJFTV 71 RA X (Right Angle Female RJ45)
Panel Drilling
n
Receptacles with IP68 backshell: • Shell type 2PE and 7PE with Plastic or Metal Gland
92 [3.622]
[3.622]
92
RJF TV
RJFTV 71 X (Straight Female RJ45)
Amphenol
RJF TV 2PE/2PEM/7PE/7PEM
Back Terminations
Type 1: Female RJ45
Type 1: Female RJ45
Notes
Type 1RA: Right Angle Female RJ45
Type 1: Female RJ45
Type 1: Female RJ45
Type 2: RJ45 Cordset
Type 2: RJ45 Cordset
Type 2: RJ45 Cordset
Type 2 - 00: Solder - 8 tinned holes
Type 2 - 00: Solder – 8 tinned holes
Type 2: RJ45 Cordset
Type 2 - 00: Solder – 8 tinned
Type 2holes
- 00: Solder – 8 tinned holes
Type 2 without RJ45 plug at the end of the cable is also available: consult factory
informations & contacts: www.rjfield.com • contact@rjfield.com
15
Assembly instructions
Insert Codings
CONNECTION SIDE VIEW
MAIN KEY
Accessories
n Metallic Caps
RJF TV
RJFTVC
Amphenol
G
Connector Type
6: Plug
2: Square Flange Receptacle
7: Jam Nut Receptacle
Shell Material & finish
N: Aluminium shell - nickel plating - ROHS compliant
G: Aluminium shell - olive drab cadmium plating
BZ: Marine bronze shell - ROHS compliant
16
2
n Panel Gasket for square flange
receptacle
(Thickness: 0,8 mm [.031]): JE19
Plug Cap
Receptacle Cap
n Insert removal tool: RJF ODE
informations & contacts: www.rjfield.com • contact@rjfield.com
RJF TV
Self Closing Cap (SCC Series)
This Self Closing cap automatically protects the RJF TV square flange receptacle (MIL-DTL-38999 type), protecting your system
from dust and water projection. A spring automatically closes the upper part of the cap when the RJF TV plug is removed
from the receptacle.
n Panel Gasket for square flange receptacle
(Thickness: 0,8 mm [.031]):
Part number:
Self closing cap only: RJFTVSCC
PART NUMBER: JE19
Remark: Compatible only with RJFTV
square flange receptacle type: RJFTV2XXX
(see page 14)
informations & contacts: www.rjfield.com • contact@rjfield.com
Amphenol
RJFTV SCC Series
IMPORTANT NOTE
Metal Self Closing cap are
sold separately (without
receptacle)
17
RJFTV
Receptacles - Plugs with 360° EMI backshells
RJFTV series receptacles and plugs with EMI backshells provide a solution with
360° shielding: same protection than the one proposed by standard MIL-DTL-38999
series III connectors. With those solutions we recommend using our reinforced and
double shielded cat5E cable, see page 24.
Square Flange Receptacle Straight Backshell
Square Flange Receptacle Right Angle Backshell
Part numbers:
Olive Drab Cadmium Plating: Kit38082
Nickel Plating: Kit38082NI
Part numbers:
Olive Drab Cadmium Plating: Kit40791
Nickel Plating: Kit40791NI
Panel Drilling
Amphenol
RJFTV - 360° shielded
Kit38082, Kit38082NI, Kit 40791 & Kit 40791NI include:
18
Jam Nut Receptacle Straight Backshell
Jam Nut Receptacle Right Angle Backshell
Part numbers:
Olive Drab Cadmium Plating: Kit40771
Nickel Plating: Kit40771NI
Part numbers:
Olive Drab Cadmium Plating: Kit38204
Nickel Plating: Kit38204NI
Panel Drilling
Kit38204, Kit38204NI, Kit 40771 & Kit 40771NI include:
informations & contacts: www.rjfield.com • contact@rjfield.com
IMPORTANT NOTE
With these receptacles, customer will have to solder his own
cable on the PCB. So the wire positions have to be defined by
the customer according to his network.
Plug Straight Backshell
WIRE POSITION
TO BE DEFINED
BY CUSTOMER
ACCORDING TO NETWORK
Plug Right Angle Backshell
Grounding Ring
Part numbers:
Olive Drab Cadmium Plating: Kit38081
Nickel Plating: Kit38081NI
Part numbers:
Olive Drab Cadmium Plating: Kit40792
Nickel Plating: Kit40792NI
Kit38081, Kit38081NI, Kit40792 & Kit40792NI include:
We advise using our double Shielded, reinforced Cat5E cable
(see page 24) with these RJFTV series EMI connectors.If customer
wants to use his own cable, please check with us regarding
compatibility with our backshells: contact@rjfield.com.
We also provide assembled cordsets, (see examples below).
For this type of solution please provide the configuration needed:
length, description of second end…
Amphenol
IMPORTANT NOTE
With these plugs, the standard RJ45 plug is not provided.
Customer will have to crimp a standard RJ45 on the cable by
himself.
RJFTV - 360° shielded
BAND-IT
Grounding
FINGERS
(BAND-IT)
informations & contacts: www.rjfield.com • contact@rjfield.com
19
ROHS
compliant
N
RJFTV
Through Bulkhead – Stand-off receptacles
Through Bulkhead Receptacles
Our RJFTV through bulkhead receptacles can be connected on each side with rugged RJFTV plugs. This system allows mechanical protection and a sealing (IP68)
inside and outside the equipement, and keeps the flexibility offered by panel mount
and plug connectors.
Olive Drab Cadmium plating – Non metallized inserts: RJFTVB2G ISO BRUT
Olive Drab Cadmium plating – Metallized inserts: RJFTVB2G ISO NI
Stand-off receptacles
These receptacles can be soldered directly to your PCB. A compound insures a transversal sealing and good performance in high-vibration environments. The shell of
those receptacles are in the « Stand Off » style. They can be connected with RJFTV
series plugs.
Square Flange Receptacle
Amphenol
RJFTV - Special receptacles
Part numbers:
Nickel plating – Non metallized inserts: RJFTVB2N ISO BRUT
Nickel plating – Metallized inserts: RJFTVB2N ISO NI
Part numbers:
Olive Drab Cadmium Plating: RJFTV25GF459
Nickel Plating: RJFTV25NF459
20
informations & contacts: www.rjfield.com • contact@rjfield.com
PCB Layout
3.
24
Solder face view
Panel Drilling
PCB Layout
Solder face view
Panel Drilling
informations & contacts: www.rjfield.com • contact@rjfield.com
Amphenol
Part numbers:
Olive Drab Cadmium Plating: RJFTV75GF459 - Nickel Plating: RJFTV75NF459
RJFTV - Special receptacles
Jam Nut Receptacle
21
ROHS
compliant
N, B & BZ
RJF/RJF TV
Environmentaly Sealed Receptacles, Transversally sealed receptacles
Sealed Receptacle In some applications, a transversal sealing for the receptacle is a
« must ». This will prevent fluids and dust from going through the receptacle when plug or
cap are not mated to the receptacle. The sealed solution (version "S") has a compound at the
rear of the receptacle as shown on the examples below. This feature is available both in RJF
and RJF TV shells (please consult the relevant data sheet for product details and accessories).
In addition, the Sealed RJF TV has been successfully tested in very high vibration corresponding to airplane applications.
Applications
n Outdoor Equipment
n Airplanes Equipment
n Tactical Radios
n Shelters
n Rugged computers
n Data Acquisition and Transmission in
Harsh Environments
MAIN CHARACTERISTICS
n
Same as the RJF and RJF TV series … a complete IP68 sealing of the receptacle
(even with no plug or no protective cap mated) is added.
n
Outside dimensions are the same as the standard RJF and RJF TV series.
n
Vibrations: The compounded versions of the RJF TV have been tested in vibration
following the NAS 1599 Aeronautic specification (Ambient temperature):
5 - 3000 Hz, 20g, 2,5 mm [.1 inch] double amplitude, 3 axes, 12 hours
Note: This specification exceeds MIL-C-26500 requirements.
Data Transmission
10 BaseT, 100 BaseTX and 1000 BaseT networks
Cat 5e per TIA/EIA 568B and ClassD per ISO/IEC
11801
IMPORTANT NOTE
Due to the compound, the coding of the
connector must be done in the factory: use
the codes A, B, C or D in the Part Number.
MAIN KEY
RJFTV 7S A 2G 15 100BTX
RJF/RJF TV
Part Number Code
Series
RJF:
RJFTV:
MIL-DTL-26482 H bayonet
MIL-DTL-38999 Series III
RJF TV
Shell Type
2S:
7S:
Sealed Square Flange Receptacle
Sealed Jam Nut Receptacle
7S
A
2
G
03 100BTX
Coding
A,B,C,D
Amphenol
Back Terminations (For Receptacles only)
1:
Female RJ45
1RA:
Right Angle Female RJ45
2:
RJ45 Cordset
Shell material & Finish
B:
Aluminium shell - black coating (Only available for RJF Series) - ROHS compliant
N:
Aluminium shell - nickel plating - ROHS compliant (note: receptacle inserts are metallized)
G:
Aluminium shell - olive drab cadmium plating (note: receptacle inserts are metallized)
BZ:
Marine bronze shell (only available for RJFTV) (receptacle inserts are metallized) - ROHS compliant
Cordset Length (For Receptacles with “2” Back Termination only)
03 100 BTX: 0.3m [11.81 inches]
05 100 BTX: 0.5m [19.68 inches]
10 100 BTX: 1m [39.37 inches]
15 100 BTX: 1.5m [59.05 inches]
Remark: Cabling configuration: 100 BTX = 568B (Ethernet specification)
Examples:
22
- Bayonet, A coding, Olive Drab Cadmium Jam Nut sealed receptacle with female RJ45 Back termination: RJF 7SA 1 G
- Bayonet, A coding, Black square flange sealed receptacle, Female RJ45 Back termination: RJF 2SA 1 B
- Series III, A coding, Olive Drab Cadmium Jam Nut sealed receptacle, 1.5m [59.05”] 100 BTX cordset: RJF TV 7SA 2 G15 100BTX
informations & contacts: www.rjfield.com • contact@rjfield.com
NEW
RJF/RJF TV
ROHS
compliant
N, B & BZ
Hermetic receptacles
HERMETIC Receptacle In some applications, a transversal hermiticity for the receptacle is a
« must ». This will prevent gas from going through the receptacle when plug or cap are not
mated to the receptacle. The hermetic solution (version "H") has a compound at the rear of
the receptacle as shown on the examples below. This feature is available both in RJF and RJF
TV shells (please consult the relevant data sheet for product details and accessories).
Helium leakage is less than 1.10-6 cm3 per second [0.1 micron cubic ft per hour] at one bar
[15 psi] pressure differential.
Applications
n Outdoor Equipment
n Airplanes Equipment
n Tactical Radios
n Shelters
n Rugged computers
n Data Acquisition and Transmission in
Harsh Environments
MAIN CHARACTERISTICS
n
Same as the RJF and RJF TV series … a complete IP68 sealing of the receptacle
(even with no plug or no protective cap mated) is added.
n
Outside dimensions are the same as the standard RJF and RJF TV series.
n
Vibrations: The compounded versions of the RJF TV have been tested in vibration
following the NAS 1599 Aeronautic specification (Ambient temperature):
5 - 3000 Hz, 20g, 2,5 mm [.1 inch] double amplitude, 3 axes, 12 hours
Note: This specification exceeds MIL-C-26500 requirements.
Data Transmission
10 BaseT, 100 BaseTX and 1000 BaseT networks
Cat 5e per TIA/EIA 568B and ClassD per ISO/IEC
11801
IMPORTANT NOTE
Due to the compound, the coding of the
connector must be done in the factory: use
the codes A, B, C or D in the Part Number.
MAIN KEY
RJFTV 7 H 2G 15 100BTX
Series
RJF:
RJFTV:
MIL-DTL-26482 H bayonet
MIL-C-38999 series III
RJF TV
Shell Type
2H:
7H:
Transversally Sealed and Hermetic Square Flange Receptacle
Transversally Sealed and Hermetic Jam Nut Receptacle
7H
A
2
G
03 100BTX
RJF/RJF TV
Part Number Code
Coding
A,B,C,D
Shell material & Finish
B:
Aluminium shell - black coating (Only available for RJF Series) - ROHS compliant
N:
Aluminium shell - nickel plating - ROHS compliant (note: receptacle inserts are metallized)
G:
Aluminium shell - olive drab cadmium plating (note: receptacle inserts are metallized)
BZ:
Marine bronze shell (only available for RJFTV) (receptacle inserts are metallized) - ROHS compliant
Cordset Length (For Receptacles with “2” Back Termination only)
03: 100 BTX: 0.3m [11.81 inches]
05: 100 BTX: 0.5m [19.68 inches]
10: 100 BTX: 1m [39.37 inches]
15: 100 BTX: 1.5m [59.05 inches]
Amphenol
Back Terminations (For Receptacles only)
1:
Female RJ45
1RA:
Right Angle Female RJ45
2:
RJ45 Cordset
Remark: Cabling configuration: 100 BTX = 568B (Ethernet specification)
Examples:
- Bayonet, A coding, Olive Drab Cadmium Jam Nut sealed receptacle with female RJ45 Back termination: RJF 7HA 1 G
- Bayonet, A coding, Black square flange sealed receptacle, Female RJ45 Back termination: RJF 2HA 1 B
- Series III, A coding, Olive Drab Cadmium Jam Nut sealed receptacle, 1.5m [59.05”] 100 BTX cordset: RJF TV 7HA 2 G15 100BTX
informations & contacts: www.rjfield.com • contact@rjfield.com
23