Bromine sensor
SGX-BR2-5
Datasheet
SGX Liquid Electrochemical Gas Sensors
These SGX Sensors use a revolutionary innovation in electrochemical sensing, which detects the output
signals from the electrochemical reactions of different gases. Furthermore, it accurately measures gas
concentration through the magnitude of the signal. These specialised sensors consist of three catalytic
electrodes, liquid electrolyte and gas diffusion holes. Through the diffusion holes, the gas reaches the
sensor's working electrode, where an electrochemical reaction takes place at the so-called 3-phase
boundary. A current signal is generated at the output, which is linearly proportional to the gas concentration.
Quality, Safety, Responsibility
SGX Europe Sp. z o.o.
T: +48 (0) 32 438 4778
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
Technical Specifications
Performance
Sensitivity
-650 ± 200 nA/ppm
Measurement Range
0 – 5 ppm
Zero Current
± 20 nA
Maximum Overload
10 ppm
Response Time
Repeatability
Lower Detectable Limit (LDL)
Linear Range
Resolution (16Bit ADC)
T50 < 20s,
T90 < 60s
2%
< 0.05 ppm
5 ppm
150qcm/min,
using SGX recommended circuitry.
Bias Voltage
0 mV
Recommended Load Resistor
220 Ω
Warm Up Time
< 60 s
• Sensor performance is temperature dependant;
please contact SGX for temperature
performance other than 20°C.
PPO
• Do not solder to the connector pins as this may
damage the sensor and thereby invalidate the
warranty.
Housing
Housing Material
Weight
© SGX Sensortech 2012-2022
< 8g
• Details on recommended connector pins can be
found in the Frequently Asked Questions within
the Gas Sensor section of the SGX website.
DS-0373-SGX-BR2-5, Issue 1, 10-Feb-2022, Page 1/3
SGX Europe Sp. z o.o.
T: +48 (0) 32 438 4778
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
Dimensions
W
R
C
Cross Sensitivity
Gas
Formula
Test Concentration
Sensor Reading
Ammonia
NH3
100ppm
0ppm
Carbon Monoxide
CO
100ppm
0ppm
Diborane
B2H 6
0.6ppm
0.3ppm
Hydrogen
H2
1000ppm
0ppm
Hydrogen Chloride
HCL
20ppm
0ppm
Hydrogen Fluoride
HF
3ppm
0ppm
Hydrogen Sulphide
H 2S
10ppm
0ppm
0.25ppm
0.05ppm
5ppm
1ppm
Ozone
Sulphur Dioxide
O3
SO2
Note:
1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results.
2) This table is not complete for all cross gases, other gas please contact with us.
© SGX Sensortech 2012-2022
DS-0373-SGX-BR2-5, Issue 1, 10-Feb-2022, Page 2/3
SGX Europe Sp. z o.o.
T: +48 (0) 32 438 4778
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
Temperature Curve
0
-100
-200
-300
-400
average
-500
std. dev.
-600
-700
-800
-900
-40
-30
-20
-10
0
10
20
30
40
50
60
Temperature(℃)
DISCLAIMER:
SGX Europe Sp. z o.o. reserves the right to change design features and specifica�ons without prior no�fica�on. We do not accept any legal responsibility for customer
applica�ons of our sensors. SGX Europe Sp. z o.o. accepts no liability for any consequen�al losses, injury or damage resul�ng from the use of this document, the
informa�on contained within or from any omissions or errors herein. This document does not cons�tute an offer for sale and the data contained is for guidance only
and may not be taken as warranty. Any use of the given data must be assessed and determined by the user thereof to be in accordance with federal, state and local laws
and regula�ons. All specifica�ons outlined are subject to change without no�ce.
SGX Europe Sp. z o.o. sensors are designed to operate in a wide range of harsh environments and condi�ons. However, it is important that exposure to high
concentra�ons of solvent vapours is to be avoided, both during storage, fi�ng into instruments and opera�on. When using sensors on printed circuit boards (PCBs),
degreasing agents should be used prior to the sensor being fi�ed. SGX Europe Sp. z o.o. makes every effort to ensure the reliability of its products. Where life safety is
a performance requirement of the product, we recommend that all sensors and instruments using these sensors are checked for response to gas before use.
Copyright© 2012-2022 SGX Sensortech All rights reserved.
Trademarks and registered trademarks are the property of their respective owners.
No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods,
without the prior written permission of the publisher, except in the case of brief quotations embodied in critical reviews and certain other non-commercial uses permitted by copyright law.
For permission requests or technical support please contact or write to the publisher, addressed “Attention: Permissions Coordinator,”.
© SGX Sensortech 2012-2022
DS-0373-SGX-CL2-5, Issue 1, 10-Feb-2022, Page 3/3
很抱歉,暂时无法提供与“SGX-BR2-5”相匹配的价格&库存,您可以联系我们找货
免费人工找货