Carbon Monoxide
sensors
SGX-SureCO
Datasheet
Quality, Safety, Responsibility
SGX Europe Sp. z o.o.
T: +48 (0) 32 438 4778
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
Technical Specifications
Performance
Product dimensions
Sensitivity
45 ± 15 nA/ppm
Measurement Range
All dimensions in mm
All tolerances ±0.15 mm
0 – 1000 ppm
Response Time
T90 < 30s
Maximum Overload
2000 ppm
Repeatability
< ±5% CO equivalent
Long-term output drift
< 5% per Annum
Linearity
Within ± 5%
Recommended Load Resistor
10 Ω
60 months
Warranty
from date of dispatch
Operating Conditions
Temperature Range
-30°C to +50°C
Pressure Range
800 to 1200 hPA
Operating Humidity Range
Storage Temperature
15-95% RH
0 to 20℃
Expected Lifetime
> 60 months
Intrinsic safety data
Maximum at 2000 ppm
0.3 mA
Maximum o/c Voltage
1.3 V
Maximum s/c Current
< 1.0 A
Key applications
• Domestic CO detectors
Cross-sensitivity data
Gas
Hydrogen Sulfide
Sulfur Dioxide
Hydrogen
Nitric Oxide
Ethanol
Iso-Propanol
Chlorine
Acetone
Acetylene
CONC.
25 ppm
20 ppm
100 ppm
50 ppm
2000 ppm
200 ppm
2 ppm
1000 ppm
40 ppm