PRODUCT SPECIFICATIONS
SGX – TRDU5
Battery Thermal Runaway Detection
TRDU-5
TRDU5 is a Battery Failure Detection sensor that measures H2, CO, NH3, Pressure,
Temperature and Humidity level when different battery leakage occur.
The module has to be placed in the battery enclosure allowing to detect a failure
mode.
TRDU5 is a solution to allow Battery Management System (BMS) monitor the safe
operation of the battery and send an earlier signal during a thermal runaway
warning to give time to passengers to leave the vehicle safely.
Features :
Automotive product
Fast response time (< 1 s)
MEMS sensor technology for H2, CO and NH3
Absolute pressure sensor inside
High sensitivities to gases H2, CO, NH3 and Hydrocarbons
Measurement redundancy (gases, pressure, temperature, humidity)
LIN 2.1 output
Thermal Runaway Trigger Signal can be setup
Standard 3 pins connector
Watertight housing IP6K7
Specifications TRDU5
Page 1 of 9
Rev. 3.1
1 Functional specifications
1.1 Principle
There are different failure mode during the battery life time that could occur.
To prevent any injury to the passengers, one solution is to send an alarm as soon as
possible to the passenger to leave the car when there is any leakage detection.
Our sensors are able to detect different gases, pressure change and environmental
changes during a thermal runway.
All the failure mode are cover and earlier than any other single sensor element.
The TRDU5 product is giving to the customer different strategy and robustness to
catch up all the cases for a quick reaction.
See below one failure mode example:
Specifications TRDU5
Page 2 of 9
Rev. 3.1
1.2 Main characteristics
Main technical characteristics
0~95% RH
Temperature and humidity
range
-40°C to +85°C
Temperature storage
-40°C to 120°C
IP level
IP6K7
Bayonet
Delphi clip (optional)
Fixing
Connector
3pins connector ref :
AMP 967642-1 Coding B
External dimensions
39mm x 35mm x 27 mm
Weight
< 15 g
Power supply operating range
9 to 15V
Power consumption
4%)
± 0.4 vol.% in air H2 ≤4%
± 10% in air H2 ≥4%
At 23 °C
CO detection
Pollution level 0 to 10
(venting phase reach the level 10)
NH3 detection
Pollution level from 0 to 10
(venting phase reach the level 10)
Pressure
Internal Temperature
Internal Humidity
Specifications TRDU5
Range: 20 to 250kPa
Resolution: 0.0329kPa
Accuracy:
± 5.5kPa between 20 and 250kPa
max allowed 300kPa
burst 750kPa
Range: -40/+85°C
Resolution: 1°C
Accuracy: ±3%
Range: 0 to 100%
Resolution: 0.0019%
Accuracy:± 3% RH (max), 0–80% RH
Page 3 of 9
Rev. 3.1
Response time (T80)
很抱歉,暂时无法提供与“TRDU5”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+402.766011+50.12000
- 5+371.016015+46.16905
- 10+359.1859310+44.69692
- 25+345.0288325+42.93521
- 50+335.3402050+41.72957
- 100+326.44884100+40.62313