RJFTVX, USBFTVX, RJ11FTVX
NEW
RJ45,USB, RJ11/12 explosion proof solutions for Zone 2
Amphenol Atex Field Bus range is
designed for device group II category 3G. According to EN60079-15
it may be operated within zone 2
and class I, Division 2, as low power
non sparking connectors.
RJFTVX • Rugged and sealed RJ45 connector
RJFTVX allows you to use an Ethernet Class D / Cat. 5e connection
for 10 BaseT, 100 BaseTx or 1000 BaseT networks in ATEX zone 2 environments. With the patented RJStop system you can use a standard
RJ45 cordset in a metallic plug which will protect it from shocks, dust
and fluids. RJFTVX features the same main characteristics than RJFTV
series (see page 14)
RJFTVX6 PLUG
CHARACTERISTICS
Ex marking
II3G ExnAIIT6 X
Operating temperature range
-40°C / +60°C
Voltage
60 Veff max
Power
20 W max
Sealing
6mm to 12mm
IP68
Data transmission
10 BaseT, 100 BaseTX & 1000
BaseT networks. Cat. 5e per
TIA/EIA 568B & Class D per
ISO/IEC 11801
Part numbers:
Nickel Plated plug: RJFTVX6MN
Olive drab cadmium plug: RJFTVX6MG
IP68 metallic cap: RJFTVC6N
IP68 metallic cap: RJFTVC6G
RJFTVX2 receptacle
Amphenol
RJF/USBF/RJ11 ATEX
Outside cable diameter
Part numbers:
52
RECEPTACLE
RECEPTACLE CAP
Nickel Plated • RJ45 back termination • coding A-: RJFTVX2SA1N
Olive drab cadmium • RJ45 back termination • coding A: RJFTVX2SA1G
Nickel: RJFTVC2N
Olive drab cadmium: RJFTVC2G
informations & contacts: www.rjfield.com & www.usbfield.com • contact@rjfield.com & contact@usbfield.com
i
m
NEW
RJFTVX7 receptacle
Part numbers:
RECEPTACLE
RECEPTACLE CAP
Nickel Plated • RJ45 back termination • coding A-: RJFTVX7SA1N
Olive drab cadmium • RJ45 back termination • coding A: RJFTVX7SA1G
IP68 metallic cap: RJFTVC7N
IP68 metallic cap: RJFTVC7G
REMARK: As receptacles are compounded (IP68 transversally sealing), coding
position has to be specified in the part number: "A" (standard), "B", "C" or "D".
Receptacles can be provided with RJ45 cordsets.
There are 4 standard lengths as described hereunder (with coding "A"):
Nickel plated / 0,3 meters RJ45 cordsets: RJFTVX2SA2N03100BTX
Nickel plated / 0,5 meters RJ45 cordsets: RJFTVX2SA2N05100BTX
Nickel plated / 1,0 meters RJ45 cordsets: RJFTVX2SA2N10100BTX
Nickel plated / 1,5 meters RJ45 cordsets: RJFTVX2SA2N15100BTX
For Olive Drab Cadmium plating replace the "N" with a "G" in the P/N.
With USBFTVX, you can insert a standard USB 2.0 cordset into
a metallic plug which will protect it from shocks, dust and fluids. This range is fitted to be used in Atex zone 2 environments
This metallic plug is connected into a receptacle, using a
Tri Start Thread coupling mechanism (MIL-DTL-38999 series
III type) with anti-decoupling device for high vibrations.
USBFTVX features the same main characteristics than USBFTV series
(see page 25)
CHARACTERISTICS
Ex marking
II3G ExnAIIT6 X
Operating temperature range
-40°C / +70°C
Voltage
60 Veff max
Power
20 W max
Outside cable diameter
Sealing
Data transmission
Amphenol
USBFTVX6 PLUG
RJF/USBF/RJ11 ATEX
USBFTVX • Rugged and sealed USB connector
4mm to 6mm
IP68
USB 2.0 up to 480 Mb/s
Part numbers:
PLUG
PLUG CAP
Nickel: USBFTVX6N
Olive drab cadmium: USBFTVX6G
Nickel: USBFTVC6N
Olive drab cadmium: USBFTVC6G
informations & contacts: www.rjfield.com & www.usbfield.com • contact@rjfield.com & contact@usbfield.com
53
NEW
USBTVX2 & USBTVX2 receptacles
Square Flange Receptacle Type USBFTV2
Jam Nut Receptacle Type USBFTV7
Cable end Type "A" (Standard USB "A" Plug)
Cable end Type "A" (Standard USB "A" Plug)
Cable end Type "OPEN" (No connector)
Cable end Type "OPEN" (No connector)
RECEPTACLE CAPS Part numbers:
Nickel plated cap for USBFTVX2: USBFTVC2N Olive drab cadmium cap for USBFTVX2: USBFTVC2G
Nickel plated cap for USBFTVX7: USBFTVC7N Olive drab cadmium cap for USBFTVX7: USBFTVC7G
Series
USB Field TV
USBF TVX
Shell Type
2S : Square flange receptacle 7S:
2S
A
2
N
03
A
Jam nut receptacle
Coding
"A" (Standard) or "B"
Back Terminations
2:
Rugged USB cable
Amphenol
RJF/USBF/RJ11 ATEX
Shells Plating
N: Nickel
54
G: Olive drab cadmium plating
USB cable length
03:
30 cm [11.81 inches]
05:
USB cable end
A: Standard USB-A plug
OPEN: Open cable (no connector)
50 cm [19.68 inches]
10:
1 meter [39.37 inches]
RJ11FTVX • Rugged and sealed RJ11/12 connector
RJ11FTVX allows you to use a standard phone RJ11 / RJ12 connection in Atex zone 2
environments. With the patented RJStop® system you can use a standard RJ11 / RJ12
cordset in a metallic plug which will protect it from shocks, dust and fluids.
CHARACTERISTICS
Ex marking
Operating temperature range
Voltage
Power
Outside cable diameter
Sealing
Coupling mechanism
Mating cycles
Salt spray
Coding
Fire retardant / Low Smoke
R11 cordset retention in the plug
II3G ExnAIIT6 X
-40°C / +60°C
60 Veff max
20 W max
4mm to 5.5mm
IP68
Tri Start thread with anti-decoupling device (MIL-DTL-38999 series III)
500 min
48h with nickel plating / 500 h with oliv drab cadmium plating
4 mechanical user-defined coding / Polarization settings (insert rotation)
UL94 V0 and NF16 101 & 16 102
100 N in the Axis
informations & contacts: www.rjfield.com & www.usbfield.com • contact@rjfield.com & contact@usbfield.com
i
Part numbers:
PLUG
CAP
Nickel plated: RJF11TVX6MN
Olive drab cadmium: RJ11FTVX6MG
Nickel plated: RJ11FTVC6N
Olive drab cadmium: RJ11FTVC6G
RJ11FTVX2
Part numbers:
RECEPTACLE
RECEPTACLE CAP
Nickel Plated - Female RJ45 back termination – coding A-: RJ11FTVX2SA1N
D'ASSEMBLAGE
Olive drab cadmiumINSTRUCTIONS
- Female RJ45 back termination
– coding A: RJ11FTVX2SA1G
Nickel plated: RJ11FTVC2N
Olive drab cadmium: RJ11FTVC2G
RJ11FTVX7
Amphenol
ASSEMBLY INSTRUCTIONS
socapex
www.RJField.com
RJF/USBF/RJ11 ATEX
FIGURE 1
Diamètre de câble acceptable : 4 à 5.5mm
Outside cable diameter : 4 to 5.5mm
RECEPTACLE CAP
Nickel Plated - Female RJ45 back termination - coding A-: RJ11FTVX7SA1N
Olive drab cadmium - Female RJ45 back termination - coding A: RJ11FTVX7SA1G
Nickel: RJ11FTVC7N
Olive drab cadmium: R11JFTVC7G
REMARK:
As receptacles are compounded (IP68 transversally sealing),
coding position has to be specified in the part number:
"A" (standard), "B", "C" or "D".
INUTE.
informations & contacts: www.rjfield.com & www.usbfield.com • contact@rjfield.com & contact@usbfield.com
Amphenol
Part numbers:
RECEPTACLE
XAGONAL
m
NEW
RJ11FTVX6 PLUG
55
NEW
RJ Switch
ROHS
compliant
Industrial Gigabit Ethernet Switch IP30
Industrial Rugged Ethernet Switch
Amphenol offers a full range of Rugged Ethernet switches for
industrial use. These switches are specifically designed for industrial
applications where Real-Time is a key requirement. The wide range,
from unmanaged Plug & Play switches to those managed with fiber
optics ports, will fulfill all your needs. This family of switches, IP30
rated, is suitable for both Din-Rail or flat panel mounting. This is an
easy way to make the Ethernet networks of your manufacturing
site, automation or control units deterministic.
This wide range of Ethernet switches is available with following
features:
• Unmanaged, Real-Time Ring and Managed models
• RJ45 ports and up to two fiber optics ports (mutlimode or singlemode)
• 5 or 9 port models
Applications
n Factory Automation
n Robotics
n Process Control
n Transportation Systems
n Data Acquisition & Transmission
• Up to 3 Gigabit ports are offered
RJ Switch
Dimensions (example for 5 Port Ring Models)
n
M
anaged Switch Networking Features
• Rapid Spanning Tree (RSTP) for fast redundant rings
• Priority queuing for real-time performance (QoS and CoS)
• SNMP v1 and v2 for network management
• SNMPv3 for authentication and encryption
• IGMP for multicast filtering
• VLAN for traffic segregation
• User friendly configuration (web, Telnet, RS232)
• Encryption using HTTPS, SSL, SSH, SNMPv3
• Message filtering to stop broadcast storms
• RMON and port mirroring for diagnostics
• The Power of Linux Inside
• 3 ports 10/100/1000 - BaseT(X) (*)
Amphenol
Power and alarm wiring
Description
(*) depend on models
56
key features
n
R
edundant power inputs with surge/spike protection
n
U
ltra reliable 1,000,000 hours MTBF
n
H
azardous location: operation in Zone 2
n
W
ide operating temperature range of –40°C to 70/85°C
n
R
ugged metal packaging with DIN rail or direct panel mounting
n
A
uto-detecting, auto-crossover and auto-polarity
n
F
ull-Duplex operation with flow control (no collisions!)
n
R
ing Switch Networking Features
• Real-Time Ring for ultra-fast fault-tolerant loops
• Recovery time of 30 ms + 5 ms per hop!
• Ideal for deterministic systems and PLCs
• Real-time traffic prioritization
• Port mirroring for traffic diagnostic
• 3 ports 10/100/1000 - BaseT(X) (*)
SC or ST fiber connector (1, 2 or none)
DIN-Rail or Panel Mounting Fixture
5 or 9 connectors (RJ45, SC or ST fiber)
Unmanaged, Ring or Managed Capability
Indicators for Power, Alarm Output Status
Indicators for Link Status and Datarate
10 Mbps
100 Mbps
1000 Mbps
Terminal block for Redundant Power Inputs + Alarm Output
IP30 Iridized Aluminum Enclosure
•
•
•
informations & contacts: www.rjswitch.com • contact@rjswitch.com
i
m
NEW
Managed, Ring & Unmanaged Switch Features
IEEE Ethernet Standards
802.3/u
802.3x
802.3z
P
P
P
P
P
P
P
P
P
P
P
10 Mbps Ethernet & 100 Mbps Fast Ethernet
Full-Duplex with Flow Control
1000 Mbps Gigabit Ethernet
Regulatory Approvals
EMI emissions
EMC immunity
Shocks
Vibrations
Free Fall
Hazardous Location
802.1p
802.1D
802.1w
802.1Q
P
P
P
P
P
P
P
P
P
P
P
IEEE 802.1p
IEEE 802.1D/w
IEEE 802.1Q
Priority queuing – QoS, CoS, ToS/DS
Rapid Spanning Tree for redundant rings
VLAN for traffic segregation
EN55022, FCC part 15, ICES-003
IEC61326-1, IEEE C37.90
IEC60068-2-27
IEC60068-2-6
IEC60068-2-32
UL1604, CSA C22.2/213 (Class 1, Div. 2), EN50021/Zone 2
EN 60079-15 (Zone 2 locations - EEx nA II T4 x)
Ethernet features
RJ45 ports
5 or 9 Shielded RJ45 ports 10/100 or 1000 BaseT(x)
Fiber optic ports
LC or SC or ST connectors
Datarate 100BaseFX (100Mbps) or 1000 Mbps for 9RG & 9MG models
Wavelength 1300 nm center
Fiber multimode (mm) optimal: 62.5/125 um
Fiber singlemode (sm) optimal: 9/125 um
Fiber max distance (Full duplex): 2km (mm), 15 or 40 km (sm) (except gigabit)
0,5km (mm), 10km (sm) for 9RG & 9MG models
Ethernet switch type
Intelligent store & forward
Full / Half Duplex
Configurable
RJ45 speed
10, 100 or 1000 Mbps auto-negotiation
RJ45 MDI/MDIX
Auto-crossover connection
RJ45 TD and RD polarity
Auto-polarity
Typical latency
16 us + frame time @ 10 Mbps (varies on load and settings)
5 us + frame time @ 100 Mbps
MAC addresses supported
8192 (MG & RG); 2048 for all other models
Memory bandwidth
32 Gbps (MG & RG); 3.2 Gbps for all other models
Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Status Ring & Managed models only
“OK” contact output
(or 10 - 50V DC depends on models)
Power Supply
Input Power (depends on models)
Redundant Inputs
- 40°C to +85°C (5 ports model + RJS 9ES)
- 40°C to +70°C (All other models)
- 40°C to +85°C
5 to 95 % RH
10 – 30V DC
Exceeds MIL-STD-1275
Power
Industrial
protection
rating
Surge
protection
Transient
protection
Spike
protection
Maximum current 0.5 A
RJ Switch
IEEE 802.3 /u
IEEE 802.3x
IEEE 802.3z
Features
Unmanaged
RING
RING - Gigabit
Managed
Managed - Gigabit
MIL-STD-1275
Available on:
RJS-5RS / RJS-9RS
RJS-9MS -4 & -5
100 V for 1s
15 KW peaks
15 KW peaks
5 KW
(10 times
for 10 µs)
5 KW
(10 times for 10 µs)
250 V
(50 times for 100 µs)
Amphenol
Models
RJS 9ES
RJS 9RS
RJS 9RG
RJS 9MS
RJS 9MG
2 W to 9W typical, all ports active at 100 Mbps
10 - 50V DC (models RJS-5RS ; RJS-9RS)
10 - 30V DC (all other models)
informations & contacts: www.rjswitch.com • contact@rjswitch.com
57
NEW
Part Number Code
Series
RJS
5ES
1
-
-
RJ-Switch
Type of Electronics
5ES: 5 ports total, Ethernet unmanaged switch
9ES: 9 ports total, Ethernet unmanaged switch
5RS: 5 ports total, Ethernet Ring switch
9RS: 9 ports total, Ethernet Ring switch
5MS: 5 ports total, Ethernet Managed switch
9MS: 9 ports total, Ethernet Managed switch
RJ45 or fiber ports
1: RJ45 ports only, no fiber
2: 1 multimode fiber ports
3: 1 singlemode fiber ports
4: 2 multimode fiber ports (except for 9ES- models)
5: 2 singlemode fiber ports (except for 9ES- models)
Style of Fiber connectors
Blank: No fiber
SC: SC style fiber connector(s)
ST: ST style fiber connector(s)
SCL: SC style fiber connector(s), long haul fiber (40km), on singlemode models
STL: ST style fiber connector(s), long haul fiber (40km), on singlemode models
Pre-set for Ring models only
E0: Pre-set for 0 rings (special order)
E1: Pre-set for 1 ring (standard order), configured on last 2 ports
E2: Pre-set for 2 rings (special order), Ring 1 = last 2 ports, Ring 2 = ports 1 & 2.
Example:
RJ-Switch, 5 ports Ethernet Ring switch, with 1 multimode ST fiber port, pre-set for 1 ring: RJS-5RS-2-ST-E1
RJS
9RG
CC
RJ-Switch
Type of Electronics
9RG: 9 ports, Unmanaged RING Ethernet Switch including 3 gigabit ports
9MG: 9 ports, Managed Ethernet Switch including 3 gigabit ports
RJ45 or fiber (FO) ports
CC: 6 ports RJ45 100 Mbps + 3 gigabit RJ45 ports
MM: 6 ports RJ45 100 Mbps + 1 port gigabit RJ45 + 2 ports FO multimode gigabit (LC connectors)
SS: 6 ports RJ45 100 Mbps + 1 port gigabit RJ45 + 2 ports FO multimode gigabit (LC connectors)
Note: 9RG models have ports 8&9 (FO or gigabit RJ45) pre-set for a ring.
Amphenol
RJ Switch
Series
58
informations & contacts: www.rjswitch.com • contact@rjswitch.com
i
m
ROHS
compliant
Atex Zone 2 Rugged & IP68 sealed Ethernet Switch
This Ethernet Switch is a combination of rugged packaging
with locking device for Zone 2 hazardous location, with faulttolerant network redundancy.
Key Features
n Ring Switch Networking Features (managed features available!)
n Real-Time Ring for ultra-fast fault-tolerant loops
• Recovery time of 30 ms + 5 ms per hop!
n Modbus monitoring over Ethernet
• Ideal for deterministic systems and PLCs
n Real-time traffic prioritization (QoS and CoS)
• Assure delivery of real-time data
• Improve network utilization
• User settable priority assignments
n Advanced switch features
• User configurable port settings
• Port mirroring for traffic diagnostics
• Pre-configurable for Plug-And-Play simplicity
Description (example for Ring model)
n Waterproof IP68 Rating (NEMA 6)
n Reduced Installation Costs with the patented RJStop® system
n Use any standard RJ45 cordset
n Rugged Enclosure in Polyester reinforced with 30% glass fiber
n Redundant power inputs with surge/spike protection
n Ultra reliable 1,000,000 hours Mean Time Between Failure (MTBF)
n Zone 2 hazardous location (models RJSPC-EX)
LEDs indicating activity, link status, datarate (10/100 Mbps)
LED indicating ring status
5 rugged IP68 RJ Field Ethernet ports
Real-time ring feature
IP68 polyester enclosure reinforced with glass fiber
OK power & ring status
LEDs indicating power
Anti-decoupling nut for power plug
Anti-decoupling spring for ethernet plugs
informations & contacts: www.rjswitch.com • contact@rjswitch.com
RJ Switch
Industrial Applications
n Oil & Gas
n Process Control
n Factory Automation
P/N: RJSPC-EX-5RS1-PLG-CAPS
Note: this part number includes:
• One ATEX Zone 2 IP68 RING Ethernet switch equipped with
caps on Ethernet connectors
• One power plug equipped with anti decoupling nut
• Five Ethernet plugs equipped with anti decoupling spring
Amphenol
Outstanding features :
• IP65/68 Sealing
• ATEX Zone 2II3G ExnAII T4X (EN60079-15 & EN60079-0)
• Plug and Play simplicity
• Ring redundancy
• Operating temperature: -40°F to 170°F (-40°C to +75°C)
P/N: RJSPC-EX-5ES1-PLG-CAPS
Note: this part number includes:
• One ATEX Zone 2 IP68 Plug and Play Ethernet switch equipped
with caps on Ethernet connectors
• One power plug equipped with anti decoupling nut
• Five Ethernet plugs equipped with anti decoupling spring
59