0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ZN0201500522

ZN0201500522

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

    -

  • 描述:

    CONTACTSOCKET24-28AWGCRIMP

  • 数据手册
  • 价格&库存
ZN0201500522 数据手册
Amphenol Amphenol-Tuchel Electronics GmbH Series C 16-3® Circular Connectors The Company Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol Corporation. With our own global presence we offer our customers exceptional technical support and worldwide service in the areas of development, production and distribution. Amphenol-Tuchel Electronics GmbH has a successful history as a partner to our customers and sets standards for connector technology. Quality From the beginning of the development process, Amphenol-Tuchel Electronics GmbH gives quality considerations the top priority. Meeting customer requirements is the main focus of the product development process. Interdisciplinary project teams with diverse backgrounds from marketing, product engineering and production guarantee the development and production of robust and reliable connector solutions. Our quality assessment begins with the initial contact to the customer and extends through the life of the product. A satisfied customer is the measure of our success. We strive to use environmentally friendly processes that minimize the waste of natural resources and introduction of toxins into the environment. Certifications: General information We reserve the right to change the design due to improvement in quality, development or production requirements. TS 16949 ISO 14001 ISO 9000:2000 This catalogue must not be used in any form or manner without our prior approval in writing (Copyright Law, Fair Trading Law, Civil Code). This release replaces all former releases. 2 Amphenol Content Page General information Serie C 16-3 2 Product description 4 Order information Approvals 5 Coding system 6 Technical data 7 Derating curves 9 View of connector style 10 Assembly instructions 11 Shell size 1 Male cable connectors 12 Female receptacles Female cable connectors 13 Male receptacles Accessories 14 Shell size 2 Male cable connectors Female receptacles 15 Female cable connectors Male receptacles 16 Accessories 17 EMV versions 18 Crimp contacts pin 21 Crimp contacts socket 22 Part No. system for crimp contacts 23 Technical Information 24 Remarks / Safety classification 27 Summary of Part Numbers 28 Amphenol 3 C 16-3 Product description The circular connector series C 16-3 has two housing sizes. The connectors are designed to meet the high requirements of industrial applications under harsh environmental conditions. The range includes versions with screw and crimp terminations. A selection of crimp contacts for hand crimp tools and crimp machines enables a reliable termination reluting in qualitative, technical and economical advantages. A board selection of housing styles are available. On choosing the housing style and shell size please take both the cable diameter and wire gauge into consideration. If neccessary one should use the long housing versions. 4 Main features and advantages: • Circular connectors for power and signal applications with following contact arrangements: Shell size 1: 8 + PE, 14 + PE, 17 + PE , 12 + 3 + PE Shell size 2: 5 + PE, 12 + PE, 14 + PE, 19 + PE •For applications in machine tools, measurement and control, process technology and medical equipment • Housing are made from high grade plastic material. •Vibration safe connection by solid bayonet coupling with lock in positon. • Cable housing straight or right-angled with various cable outlets •Protection degree IP 65 in mated position. •Internal cable clamp or clamping ring provides a safe cable restrain. Amphenol C 16-3 Product description Order information Approvals Order information Colour coding Upon request the coupling ring of the plugs and the housing of the receptacles can be delivered in the colour red, green, blue, yellow and grey. Crimp version Order numbers do not include crimp contacts. Please order separately (page 21 / 22) Polarization Depending on the contact arrangements the polarization of this connector series can be varied. The contact inserts can be mounted in alternate positions. The order number in the catalogue refers always to postition 1. The postition of the contact inserts can also be changed by the customer using a disassembly tool ( see page 14 and 17) to remove the insert and remount it in the required position ( see page 6) Crimp tooling Ask for our catalogue “Tools”. Testhouse Approvals Approval No. VDE 3964 UL 1) E 63093 CSA 49932-9 In general approvals refer to representative versions of the connector series. Test report upon request. Please refer to the „Conditions of Acceptability“. 1) Amphenol 5 C 16-3 Coding system Polarization Depending on the contact arrangements the polarization of this connector series can be varied. Please take care of the housing and contact insert characteristics. Shell size 1 Shell size 2 No of contacts No of coding possibil. Position No of contacts No of coding possibil. Position 8 + PE 4 1, 3, 5, 7 5 + PE 6 1, 2, 3, 4, 6, 7 14 + PE 7 1, 2, 3, 4, 5, 6, 7 14 + PE 7 1, 2, 3, 4, 5, 6, 7 17 + PE 6 1, 2, 3, 4, 5, 7 12 + PE 7 1, 2, 3, 4, 5, 6, 7 12 + 3 + PE 4 1, 3, 5, 7 19 + PE 6 1, 3, 4, 5, 6, 7 Coding point on the shell Coding point on the contact insert Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pin contact insert termination side Pos. 5 Pos. 6 Pos. 7 Pos. 1 Pos. 2 Pos. 3 Pos. 4 Socket contact insert termination side Pos. 5 Pos. 6 Pos. 7 Disassembly of contact inserts with disassembly tool (see page 14 and 17) Pin or socket contact insert Disassembly tools: shell size 1: see page 14 shell size 2: see page 17 6 Amphenol C 16-3 Technical data Shell size 1 General Characteristics Standard Technical data Shell size 1 8 + PE 14 + PE 17 + PE 12 + 3 + PE DIN EN 60664-1 1) 400 V 100 V 100 V 3 x 320 V, 12 x 24 V UL 1977, CSA 22.2 Number of contacts Electrical Characteristics Rated voltage 400 V 3 x 250 V, 11 x 250 V 250 V 3 x 250 V, 12 x 24 V DIN EN 60664-1 1) 6000 V 3000 V 3000 V 3 x 4000 V, 12 x 800 V Pollution degree DIN EN 60664-1 1) 3 3 3 3 Installation (overvoltage) category DIN EN 60664-1 1) III III III III Material group DIN EN 60664-1 1) II II II II Current carrying capacity DIN EN 60512-5-2, test 5b 12 A 3 x 16 A, 11 x 6 A 6A 3 x 12 A, 12 x 6 A UL 1977, CSA 22.2 10 A 3 x 12 A, 11 x 4 A 5A 3 x 10 A, 12 x 5 A ≤ 22 N ≤ 25 N Rated impulse withstand voltage ≥ 10 Ω DIN EN 60512-3-1, test 3a DIN EN 60512-2-1, test 2a Insulation resistance Contact resistance 8 ≤ 5 mΩ Climatic Characteristics Climatic category DIN EN 60068-1 40 / 125 / 56 Operating temperature -40°C ... +125°C Mechanical Characteristics Degree of protection DIN EN 60529 Insertion and withdrawal force DIN EN 60512-13-2, test 13b IEC 60512, test 9a Mechanical operation IP 65 ≤ 25 N ≤ 30 N ≥ 500 mating cycles Materials Housing material Polyamide 6.6 Dielectric material Polyamide 6.6 Gasket material Neoprene Contact plating silver plated / gold plated Other Characteristics Termination technique crimp Wire gauge / AWG Flammability Locking system 0,14 - 2,5 mm2 / 26 - 14 UL 94 0,09 - 1,0 mm2 / 28 - 18 0,09 - 2,5 mm2 / 28 - 14 VO bayonet 1) Amphenol 0,09 - 2,5 mm2 / 28- 14 DIN 60664-1 =^ VDE 0110-1 =^ DIN EN 60664-1 The stated technical values refer to the use as connector. If these components are used as plug and socket device a reduced current carrying capacity has to be considered. 7 C 16-3 Technical data Shell size 2 General Characteristics Technical data Standard Shell size 2 5 + PE 12 + PE 14 + PE 19 + PE DIN EN 60664-1 1) 400 V 3 x 500 V, 9 x 300 V 400 V 250 V UL 1977, CSA 22.2 400 V 3 x 400 V, 9 x 250 V 10 x 400 V, 4 x 250 V 250 V 6000 V 3 x 6000 V, 9 x 4000 V 6000 V 4000 V Number of contacts Electrical Characteristics Rated voltage 1) Rated impulse withstand voltage DIN EN 60664-1 Pollution degree DIN EN 60664-1 1) 3 3 3 3 Installation (overvoltage) category DIN EN 60664-1 1) III III III III Material group DIN EN 60664-1 1) II II II II Current carrying capacity DIN EN 60512-5-2, test 5b 21 A 3 x 21 A, 9 x 11 A 4 x 6 A, 10 x 12 A 6A UL 1977, CSA 22.2 16 A 3 x 10 A, 9 x 5 A 10 x 10 A, 4 x 5 A 5A Insulation resistance Contact resistance ≥ 10 Ω DIN EN 60512-3-1, test 3a DIN EN 60512-2-1, test 2a 8 ≤ 5 mΩ Climatic Characteristics Climatic category DIN EN 60068-1 40 / 100 / 56 Operating temperature 40 / 125 / 56 -40°C ... +125°C (5+PE: +100°C) Mechanical Characteristics Degree of protection DIN EN 60529 Insertion and withdrawal force DIN EN 60512-13-2, test 13b DIN EN 60512-9-1, test 9a Mechanical operation IP 65 ≤ 15 N ≤ 25 N ≤ 30 N ≤ 25 N ≥ 500 mating cycles Materials Housing material Polyamide 6.6 Dielectric material Poliamide 6.6 Gasket material Neoprene Contact plating silver plated/ gold plated Other Characteristics Termination technique screw Wire gauge / AWG Flammability Locking system 8 4 mm2 / 10 UL 94 crimp 0,09 - 2,5 mm2 / 28 - 14 0,09 - 2,5 mm2 / 28 - 14 0,09 - 1,0 mm2 / 28 - 18 VO bayonet 1) DIN EN 60664-1 =^ VDE 0110-1 =^ IEC 60664-1 The stated technical values refer to the use as connector. If these components are used as plug and socket device a reduced current carrying capacity has to be considered. Amphenol C 16-3 Derating curves Shell size 1 8+PE 8+PE a) Kon a) alle all contacts Ø 1,6 Anschlu wire gauge 1,5 mm 2 all cont wire gau 16 14 12 10 8 6 4 2 0 10 20 30 40 50 60 70 80 90 100 110 120 A Current carrying capacity Current carrying capacity A °C a 20 15 10 0 10 20 30 40 50 60 70 80 90 100 110 120 °C 12+3+PE 12+3+PE 4 contacts a) alle Kont Ø 1,6 wire gauge 1,5 mm 2 Anschluß b) 12 contacts b) alle Kont Ø 1,5 wire gauget 0,5 mm 2 Anschluß A Current carrying capacity Current carrying capacity 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature 17+PE 17+PE all contacts Ø 1,5 alle Kon wire gauge 0,5 mm 2 Anschlu all conta wire gau 10 9 8 7 6 5 4 3 2 1 b 5 Ambient temperature A 14+PE 14+PE a) contacts Ø 2,5 a) 44 Kon wire gauge 1,5 mm 2 Ansch b) 411con contacts Ø 1,5 wire wire ggauge 0,5 mm 2 b) 11 Ko Ansch 11 con wire g 16 14 12 10 8 6 4 2 0 °C Ambient temperature a b 10 20 30 40 50 60 70 80 90 100 110 120 °C Ambient temperature Shell size 2 5+PE 5+PE a) alle all contacts Ø 2,0 Ko Ansch wire gauge 4,0 mm 2 b) all all con contacts Ø 2,0 wire ga wire gauge 2,5 mm 2 b) alle Ko Ansch all con wire ga 0 10 20 30 40 50 60 70 80 90 100 110 120 A Current carrying capacity Current carrying capacity A 36 33 30 27 24 21 18 15 12 9 6 3 °C 30 25 20 15 5 0 15 10 a b 5 0 10 20 30 40 50 60 70 80 90 100 110 120 Ambient temperature Amphenol 10 20 30 40 50 60 70 80 90 100 110 120 °C Ambient temperature 14+PE 14+PE a) contacts Ø 1,6 a) 11 11 Ko Ansch wire gauge 1,5 mm 2 co b) 11 4 contacts Ø 1,5 wire g wire gauge 0,5 mm 2 b) 4 Kon Ansch 4 con wire g °C A Current carrying capacity Current carrying capacity 20 b 10 Ambient temperature A a 12+PE 12+PE a) 34 Kon contacts Ø 2,5 Ansc wire gauge 2,5 mm 2 b) 39 con contacts Ø 1,6 wire g wire gauge 2,5 mm 2 b) 9 Kon Ansc 9 con wire g 19+PE 19+PE all Ø 1,5 allecontacts Kon wire gauge 0,5 mm 2 Anschlu all conta wire gau 12 11 10 9 8 7 6 5 4 3 2 1 0 10 20 30 40 50 60 70 80 90 100 110 120 °C Ambient temperature 9 C 16-3 Male cable connector, Shell size 1 and 2 Identification Male cable connector Figure Description Conn. Style Long version with internal cable clamp Page Size 1 Size 2 12 15 12 15 12 15 13 16 13 16 13 16 13 15 13 – 14 16 I Short version, with clamping ring H Right -angled, with clamping ring K Female cable connector Long version with internal cable clamp E Short version, with clamping ring D Right-angled, with clamping ring F Female receptacle Flange mounting, with mounted gasket G Panel mounting with ring nut, with gasket N Male receptacle Flange mounting, with mounted gasket C 10 Amphenol C 16-3 Assembly instructions Shell size 1 and 2 Torque for back shell and cable screw min. 1 Nm max. 2 Nm clamping ring short back shell cable nut sealing gasket long back shell metal washer internal strain relief male insert with locking ring right-angled back shell tightening torque 0,5 Nm female insert with locking ring Shinning lengths Screw contacts Crimp contacts 0,09 - 0,25 mm2 0,35 - 0,50 mm2 0,50 - 2,50 mm2 1) Amphenol C 16-3 +1 7,0 mm 3 +0,5 mm 3 +0,5 mm 3,5 +1 mm 1) Remarks: The dimensions are for general information only and can vary depending on cable styles and types. Please make sure that the usability of the cable in conjunction with the clamping ring is given. end splice recommended Amphenol 11 C 16-3 Shell size 1 Male cable connectors I Description H Drawing No. of cont. K Contacts2) Part No. Cable outlet Ø 10 -12 8 + PE Male cable connector for crimp contacts, long, style I with internal cable clamp, without contacts 1) Ø 12 -14 .N 01 016 00... C016 10I008 002 1 C016 10I008 003 1 14 + PE 11 x C016 10I014 002 1 C016 10I014 003 1 .N 01 015 00... 4x .N 01 025 00... C016 10I015 002 1 C016 10I015 003 1 12+3+PE 12 x .N 01 015 00... 4x .N 01 016 00... 17 + PE .N 01 015 00... C016 10I017 002 1 C016 10I017 003 1 Cable outlet Ø 8 -10 Male cable connector for crimp contacts, short, style H with clamping ring, without contacts 1) Ø 10 -12 8 + PE .N 01 016 00... C016 10H008 002 1 C016 10H008 003 1 2) 14 + PE 11 x C016 10H014 002 1 C016 10H014 003 1 .N 01 015 00... 4x .N 01 025 00... C016 10H015 002 1 C016 10H015 003 1 12+3+PE 12 x .N 01 015 00... 4x .N 01 016 00... 17 + PE .N 01 015 00... C016 10H017 002 1 C016 10H017 003 1 Male cable connector for crimp contacts, style K with clamping ring, without contacts 1) 8 + PE .N 01 016 00... C016 10K008 002 1 C016 10K008 003 1 14 + PE 11 x C016 10K014 002 1 C016 10K014 003 1 .N 01 015 00... 4x .N 01 025 00... 12+3+PE 12 x C016 10K015 002 1 C016 10K015 003 1 .N 01 015 00... 4x .N 01 016 00... 17 + PE .N 01 015 00... C016 10K017 002 1 C016 10K017 003 1 1) Please order crimp contacts separately, see page 21/22. 12 2) Part No system for crimp contacts, see page 23. Amphenol G Description Drawing 28,6 ±0,1 (1.126) Ø 26,2 +0,2 (1.031) oder M3,5 Ø 3,8 +0,1 (.15) Shell size 1 Female receptacles 30,2 +0,2 (1.189) 28,6 ±0,1 (1.126) C 16-3 SW27,2 +0,2 (1.071) N Panel cutout No. of cont. 8 + PE Female receptacle for crimp contacts, style G, without contacts 1) Contacts 2) .N 02 016 00… 14 + PE 11 x .N 02 015 00... 4 x .N 02 025 00... 12 + 3 + PE 12 x .N 02 015 00... 4 x .N 02 016 00... Female receptacle for crimp contacts, style N, without contacts 1) Panel cutout Part No. C016 10G008 000 1 C016 10G014 000 1 C016 10G015 000 1 17 + PE .N 02 015 00... C016 10G017 000 1 8 + PE .N 02 016 00... C016 10N008 006 1 11 x .N 02 015 00... 4 x .N 02 025 00... 12 +3+ PE 12 x .N 02 015 00... 4 x .N 02 016 00... 14 + PE 17 + PE .N 02 015 00... C016 10N014 006 1 C016 10N015 006 1 C016 10N017 006 1 C 16-3 Shell size 1 Female cable connectors E Description Drawing D No. of cont. F Contacts 2) Part No. Cable outlet Ø 10-12 Ø 12-14 8 + PE .N 02 016 00.. C016 10E008 002 1 C016 10E008 003 1 14 + PE 11 x .N 02 015 00... C016 10E014 002 1 C016 10E014 003 1 4 x .N 02 025 00.. 12+3+PE 12 x .N 02 015 00... C016 10E015 002 1 C016 10E015 003 1 4 x .N 02 016 00... 17 + PE .N 02 015 00... C016 10E017 002 1 C016 10E017 003 1 Female cable connector for crimp contacts, long, style E with internal strain relief, without contacts 1) Cable outlet Ø 8-10 8 + PE Female cable connector for crimp contacts, short, style D with clamping ring, without contacts 1) Ø 10-12 .N 02 016 00... C016 10D008 002 1 C016 10D008 003 1 14 + PE 11 x .N 02 015 00... C016 10D014 002 1 C016 10D014 003 1 4 x .N 02 025 00... 12+3+PE 12 x .N 02 015 00... C016 10D015 002 1 C016 10D015 003 1 4 x .N 02 016 00... 17 + PE .N 02 015 00... C016 10D017 002 1 C016 10D017 003 1 8 + PE Female cable connector for crimp contacts, style F with clamping ring, without contacts 1) .N 02 016 00... C016 10F008 002 1 C016 10F008 003 1 14 + PE 11 x .N 02 015 00... C016 10F014 002 1 C016 10F014 003 1 4 x .N 02 025 00... 12+3+PE 12 x .N 02 015 00... C016 10F015 002 1 C016 10F015 003 1 4 x .N 02 016 00... 17 + PE .N 02 015 0005 C016 10F017 002 1 C016 10F017 003 1 1) Please order crimp contacts separately, see page 21/22. Amphenol 2) Part No system for crimp contacts, see page 23. 13 Description Drawing No. of cont. Male receptacle for crimp contacts, style C, without contacts 1) Ø 26,2 +0,2 (1.031) oder M3,5 C Ø 3,8 +0,1 (.15) Shell size 1 Male receptacles 28,6 ±0,1 (1.126) 28,6 ±0,1 (1.126) C 16-3 Panel cutout Contacts 2) Part No. .N 01 016 00... C016 10C008 000 1 8 + PE .N 01 016 00... C016 10C008 000 1 14 + PE 11 x .N 01 015 00... 4 x .N 01 025 00... C016 10C014 000 1 12 + 3 + PE 12 x .N 01 015 00... 4 x .N 01 016 00... C016 10C015 000 1 17 + PE .N 01 015 00... C016 10C017 000 1 C 16-3 Shell size 1 Accessories Description Part No. Drawing for male cable connector Protective cap for male cable connector and male receptacle C016 00U000 001 1 for male cable connector Protective cap for female cable connector and female receptacle C016 00V000 001 1 Disassembly tool for pin- and socket inserts 1) Please order crimp contacts separately, see page 21/22. 14 for male receptacle C016 00U000 021 1 for male receptacle C016 00V000 021 1 FH 0000-016 2) Part No system for crimp contacts, see page 23. Amphenol C 16-3 Shell size 2 Male cable connectors I Description Drawing H K Contacts 2) No. of cont. Ø 12-14 5 + PE Male cable connector, long, style I with internal strain relief, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 12 + PE 9 x .N 01 016 00... C016 10I012 003 2 C016 10I012 004 2 C016 10I012 005 2 4 x .N 01 025 00... 14 + PE 4 x .N 01 015 00... C016 10I014 003 2 C016 10I014 004 2 C016 10I014 005 2 11 x .N 01 016 00... 19 + PE .N 01 015 000... 5 + PE Male cable connector, style K with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Ø 19-21 C016 20I005 103 2 C016 20I005 104 2 C016 20I005 105 2 – C016 10I019 003 2 C016 10I019 004 2 C016 10I019 005 2 Ø 10-12 Male cable connector, short, style H with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Part No. Cable outlet 3) Ø 14-16 Cable outlet Ø 12-14 Ø 14-18 C016 20H005 103 2 C016 20H005 104 2 – 12 + PE 9 x .N 01 016 00... C016 10H012 003 2 C016 10H012 004 2 4 x .N 01 025 00... – 14 + PE 4 x .N 01 015 00... C016 10H014 003 2 C016 10H014 004 2 C016 10H014 005 2 11 x .N 01 016 00... 19 + PE .N 01 015 00... 5 + PE – – C016 10H019 003 2 C016 10H019 004 2 – – C016 20K005 104 2 – 12 + PE 9 x .N 01 016 00... 4 x .N 01 025 00... – C016 10K012 004 2 – 14 + PE 4 x .N 01 015 00... 11 x .N 01 016 00... – C016 10K014 004 2 – 19 + PE .N 01 015 00... – C016 10K019 004 2 – C 16-3 Ø Shell size 2 Female receptacle Ø G Description Drawing No. of cont. Female receptacle, style G, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PE version without contacts 1) 1) Please order crimp contacts separately, see pag 21/22. Amphenol 5 + PE 2) Contacts 2) – Panel cutout Part No. C016 20G005 100 2 12 + PE 9 x .N 02 016 00… 4 x .N 02 025 00… C016 10G012 000 2 14 + PE 4 x .N 02 015 00… 11 x .N 02 016 00… C016 10G014 000 2 19 + PE .N 02 015 00... C016 10G019 000 2 Part No system for crimp contacts, see page 23. 15 C 16-3 Shell size 2 Female cable connectors E Description Drawing D F Contacts 2) No. of cont. Ø 12-14 – 5 + PE Female cable connector, long, style E with internal strain relief, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Part No. Cable outlet 3) Ø 14-16 Ø 19-21 C016 20E005 103 2 C016 20E005 104 2 C016 20E005 105 2 12 + PE 9 x .N 02 016 00… C016 10E012 003 2 C016 10E012 004 2 C016 10E012 005 2 4 x .N 02 025 00… 14 + PE 4 x .N 02 015 00… C016 10E014 003 2 C016 10E014 004 2 C016 10E014 005 2 11 x .N 02 016 00… 19 + PE .N 02 015 00... C016 10E019 003 2 C016 10E019 004 2 C016 10E019 005 2 Cable outlet Ø 10-12 Ø 12-14 5 + PE Female cable connector, short, style D with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) Female cable connector, style F with clamping ring, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) – C016 20D005 103 2 C016 20D005 104 2 – 12 + PE 9 x .N 02 016 00… C016 10D012 003 2 C016 10D012 004 2 4 x .N 02 025 00… – 14 + PE 4 x .N 02 015 00… C016 10D014 003 2 C016 10D014 004 2 11 x .N 02 016 00… – 19 + PE .N 02 015 00... – C016 10D019 003 2 C016 10D019 004 2 5 + PE – – C016 20F005 104 2 – 12 + PE 9 x .N 02 016 00… 4 x .N 02 025 00… – C016 10F012 004 2 – 14 + PE 4 x .N 02 015 00… 11 x .N 02 016 00… – C016 10F014 004 2 – 19 + PE .N 02 015 00... – C016 10F019 004 2 – C 16-3 Ø Shell size 2 Male receptacle Ø C Description Drawing No. of cont. Male receptacle, style C, 5 + PE screw termination, 12 + PE-, 14 + PE and 19 + PEversion without contacts 1) 1) Please order crimp contacts separately, see page 21/22. 16 2) Contacts 2) Panel cutout Part No. 5 + PE – C016 20C005 100 2 12 + PE 9 x .N 01 016 00… 4 x .N 01 015 00... C016 10C012 000 2 14 + PE 4 x .N 01 015 00… 11 x .N 01 016 00… C016 10C014 000 2 19 + PE .N 01 015 00... C016 10C019 000 2 Part No system for crimp contacts, see page 23. Amphenol C 16-3 Shell size 2 Accessories Description Protective cap for male cable connector and male receptacle Part No. Figure for male cable connector for male receptacle C016 00U000 011 2 Protective cap for female cable connector and female receptacle for female cable connector C016 00U000 001 2 for female receptacle C016 00V000 011 2 Disassembly tool for pin-and socket inserts Amphenol C016 00V000 001 2 FH 0002-016 17 C 16-3 EMV Product description The C 16-3 EMI connectors excel by versatile fields of application, especially high mechanical requirements, industrial ebvironments and demands for safe contact. Main features: • high attenuation of shielding • contact inserts suitable for standard and EMI versions • completely compatible with standard C 16-3, size 1 • same technical characteristics as standard C 16-3, see page 7 • mechanical lifetime: 100 mating cycles • we recommend the usage of the versions with two-part metal housing in very harsh environmental conditions Two versions available: 1.Version with metalized plastic housing accord. VDE 0610. PE wire is connected to cable shield and housing. In case of error the current will be lead directly to the PE wire 2.Combined version with metalized plastic and two-part metal housing accord. VDE 0113. PE wire is securely and firmly connected with the metal housing. Crimp version Order numbers do not include crimp contacts. Please order separately (see page 21/22). Crimp contact for higher currents are available upon request. Crimp tooling Ask for our catalogue “Tools”. Testhouse UL 1) 1) Approval Approval No. E 63093 Please refer to the „Conditions of Acceptability“ 18 Amphenol C 16-3 EMV Shell size 1 Description Drawing No. of cont. Contacts 2) Part No. Cable outlet Ø max. 10.5 Male cable connector, style H, without contacts 1), without cable screw, metalized plastic housing Ø max. 12.5 8 + PE .N 01 016 00... C016 10H008 012 5 C016 10H008 013 5 14 + PE 11 x C016 10H014 012 5 C016 10H014 013 5 .N 01 015 00... 4x .N 01 025 00... 12+3+PE 12 x C016 10H015 012 5 C016 10H015 013 5 .N 01 015 00... 4x .N 01 016 00... 17 + PE .N 01 015 00... C016 10H017 012 5 C016 10H017 013 5 Female cable connector, style D, without contacts 1), without cable screw, metalized plastic housing 8 + PE .N 02 016 00... C016 10D008 012 5 C016 10D008 013 5 14 + PE 11 x C016 10D014 012 5 C016 10D014 013 5 .N 02 015 00... 4x .N 02 025 00... 12+3+PE 12 x C016 10D015 012 5C016 10D015 013 5 .N 02 015 00... 4x .N 02 016 00... 17 + PE .N 02 015 00... C016 10D017 012 5 C016 10D017 013 5 Cable outlet Ø 9 -11 Male cable connector, without contacts 1), two part metal housing, with PE contact 8 + PE .N 01 016 00... C016 10H008 801 3 14 + PE 11 x C016 10H014 801 3 .N 01 015 00... 4x .N 01 025 00... 12+3+PE 12 x C016 10H015 801 3 .N 01 015 00... 4x .N 01 016 00... Female cable connector, without contacts 1), two part metal housing, with PE contact. 17 + PE .N 01 015 00... C016 10H017 801 3 8 + PE .N 02 016 00... C016 10D008 801 3 14 + PE 11 x C016 10D014 801 3 .N 02 015 00... 4x .N 02 025 00... 12+3+PE 12 x C016 10D015 801 3 .N 02 015 00... 4x .N 02 016 00... 17 + PE .N 02 015 00... 1) Please order crimp contacts separately, see page 21/22. Amphenol 2) C016 10D017 801 3 Part No system for crimp contacts, see page 23. 19 Description Drawing Female receptacle, style N, without contacts 1) Male receptacle, style C, without contacts 1) 30,2 +0,2 (1.189) SW27,2 +0,2 (1.071) Panel cutout No. of cont. Female receptacle, style G, without contacts 1) 28,6 ±0,1 (1.126) oder M3,5 Ø 3,8 +0,1 (.15) Shell size 1 Ø 26,2 +0,2 (1.031) 28,6 ±0,1 (1.126) C 16-3 EMV Panel cutout Contacts 2) Part No. 8 + PE .N 02 016 00… C016 10G008 000 5 14 + PE 11 x.N 02 015 00... 4 x.N 02 025 00... C016 10G014 000 5 12 + 3 + PE 12 x .N 02 015 00... 4 x .N 02 016 00... C016 10G015 000 5 17 + PE .N 02 015 00... C016 10G017 000 5 8 + PE .N 02 016 00… C016 10N008 000 5 14 + PE 11 x.N 02 015 00... 4 x.N 02 025 00… C016 10N014 000 5 12+3+ PE 12 x .N 02 015 00... 4 x .N 02 016 00... C016 10N015 000 5 17 + PE .N 02 015 00... C016 10N017 000 5 8 + PE .N 01 016 00… C016 10C008 000 5 14 + PE 11 x.N 01 015 00... 4 x.N 01 025 00… C016 10C014 000 5 12+3+PE 12 x .N 01 015 00... 4 x .N 01 016 00... C016 10C015 000 5 .N 01 015 00... C016 10C017 000 5 17 + PE Assembly instructions metal housing tightening torque 4 - 5 Nm ht eflec irmg +1 Sch 15 +2 25 +2 65 65 +2 ntel 1 4+ . Ma 4 min +2 25 +2 65 tightening torque 5 - 7 Nm 1 4+ tightening torque 4 - 5 Nm 20 1) Please order crimp contacts separately, see page 21/22. 2) Part No system for crimp contacts, see page 23. Amphenol 16-3 Stamped single contacts Stamped contacts on reel for hand crimping tools Crimp contacts Pin Series C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 Contact Ø in mm 1,5 1,5 1,5 1,6 1,6 1,6 2,5 Stamped contacts on reel for crimp machines 100 resp. 200 pcs Isulation Ø in mm 0,7 - 1,6 1,3 - 2,0 1,6 - 2,1 1,0 - 2,0 1,8 - 2,8 2,5 - 3,5 1,8 - 2,8 2,5 - 3,5 No. of cont. Shell size Wire gauge in mm2 AWG Supplied as 2000 pcs. (feeding left or right hand side) pcs. Part No. Contact plating silver gold 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,09 - 0,25 mm2 single contact 100 VN 01 015 0052 (1) VN 01 015 0052 (2) 28 - 24 contacts on reel 200 ZN 01 015 0052 (1) ZN 01 015 0052 (2) right 2000 HN 01 015 0052 (1) HN 01 015 0052 (2) left 2000 TN 01 015 0052 (1) 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,35 - 0,5 mm2 single contact 100 VN 01 015 0046 (1) VN 01 015 0046 (2) 22 - 20 contacts on reel 200 ZN 01 015 0046 (1) ZN 01 015 0046 (2) right 2000 HN 01 015 0046 (1) HN 01 015 0046 (2) left 2000 TN 01 015 0046 (1) 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,75 - 1,0 mm2 single contact 100 VN 01 015 0047 (1) VN 01 015 0047 (2) 18 contacts on reel 200 ZN 01 015 0047 (1) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 0,14 - 0,5 mm2 single contact 100 VN 01 016 0003 (1) VN 01 016 0003 (2) 26 - 20 contacts on reel 200 ZN 01 016 0003 (1) TN 01 015 0052 (2) TN 01 015 0046 (2) ZN 01 015 0047 (2) right 2000 HN 01 015 0047 (1) HN 01 015 0047 (2) left 2000 TN 01 015 0047 (1) TN 01 015 0047 (2) ZN 01 016 0003 (2) right 2000 HN 01 016 0003 (1) HN 01 016 0003 (2) left 2000 TN 01 016 0003 (1) TN 01 016 0003 (2) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 0,5 - 1,5 mm2 single contact 100 VN 01 016 0002 (1) VN 01 016 0002 (2) 20 - 16 contacts on reel 100 ZN 01 016 0002 (1) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 1,5 - 2,5 mm 14 + PE 12 + PE 14 + PE 12 + PE 1 2 1 2 2 16 - 14 ZN 01 016 0002 (2) right 2000 HN 01 016 0002 (1) HN 01 016 0002 (2) left 2000 TN 01 016 0002 (1) TN 01 016 0002 (2) single contact 100 VN 01 016 0005 (1) VN 01 016 0005 (2) contacts on reel 200 ZN 01 016 0005 (1) ZN 01 016 0005 (2) right 2000 HN 01 016 0005 (1) HN 01 016 0005 (2) left 2000 TN 01 016 0005 (1) TN 01 016 0005 (2) 0,5 - 1,5 mm2 single contact 100 VN 01 025 0001 (101) VN 01 025 0001 (102) 20 - 16 contacts on reel 100 ZN 01 025 0001 (1) ZN 01 025 0001 (2) right 2000 HN 01 025 0001 (1) HN 01 025 0001 (2) left 2000 TN 01 025 0001 (1) TN 01 025 0001 (2) 1,5 - 2,5 mm2 single contact 100 VN 01 025 0010 (101) VN 01 025 0010 (102) 16 - 14 contacts on reel 200 ZN 01 025 0010 (1) ZN 01 025 0010 (2) right 2000 HN 01 025 0010 (1) HN 01 025 0010 (2) left 2000 TN 01 025 0010 (1) TN 01 025 0010 (2) Single contact in plastic bag; stamped contact on reel – HN = feeding right side / TN = feeding left side Amphenol 21 16-3 Stamped single contacts Stamped contacts on reel for hand crimping tools Crimp contacts Socket Series C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 C 16-3 Contact Ø in mm 1,5 1,5 1,5 1,6 1,6 1,6 2,5 Stamped contacts on reel for crimp machines 100 resp. 200 pcs Isulation Ø in mm 0,7 - 1,6 1,3 - 2,0 1,6 - 2,1 1,0 - 2,0 1,8 - 2,8 2,5 - 3,5 1,8 - 2,8 2,5 - 3,5 No. of cont. Shell size Wire gauge in mm2 AWG Supplied as 2000 pcs. (feeding left or right hand side) pcs. Part No. Contact plating silver gold 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,09 - 0,25 mm2 single contact 100 VN 02 015 0052 (1) VN 02 015 0052 (2) 28 - 24 contacts on reel 200 ZN 02 015 0052 (1) ZN 02 015 0052 (2) right 2000 HN 02 015 0052 (1) HN 02 015 0052 (2) left 2000 TN 02 015 0052 (1) TN 02 015 0052 (2) 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,35 - 0,5 mm2 single contact 100 VN 02 015 0046 (1) VN 02 015 0046 (2) 22 - 20 contacts on reel 200 ZN 02 015 0046 (1) ZN 02 015 0046 (2) right 2000 HN 02 015 0046 (1) HN 02 015 0046 (2) left 2000 TN 02 015 0046 (1) TN 02 015 0046 (2) 14 + PE 12 + 3 + PE 17 + PE 14 + PE 19 + PE 1 1 1 2 2 0,75 - 1,0 mm2 single contact 100 VN 02 015 0047 (1) VN 02 015 0047 (2) 18 contacts on reel 200 ZN 02 015 0047 (1) ZN 02 015 0047 (2) right 2000 HN 02 015 0047 (1) HN 02 015 0047 (2) left 2000 TN 02 015 0047 (1) TN 02 015 0047 (2) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 0,14 - 0,5 mm2 single contact 100 VN 02 016 0003 (1) VN 02 016 0003 (2) 26 - 20 contacts on reel 200 ZN 02 016 0003 (1) ZN 02 016 0003 (2) right 2000 HN 02 016 0003 (1) HN 02 016 0003 (2) left 2000 TN 02 016 0003 (1) TN 02 016 0003 (2) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 0,5 - 1,5 mm2 single contact 100 VN 02 016 0002 (1) VN 02 016 0002 (2) 20 - 16 contacts on reel 100 ZN 02 016 0002 (1) ZN 02 016 0002 (2) right 2000 HN 02 016 0002 (1) HN 02 016 0002 (2) left 2000 TN 02 016 0002 (1) TN 02 016 0002 (2) 8 + PE 12 + 3 + PE 12 + PE 14 + PE 1 1 2 2 1,5 - 2,5 mm single contact 100 VN 02 016 0005 (1) VN 02 016 0005 (2) contacts on reel 200 ZN 02 016 0005 (1) ZN 02 016 0005 (2) right 2000 HN 02 016 0005 (1) HN 02 016 0005 (2) left 2000 TN 02 016 0005 (1) TN 02 016 0005 (2) 14 + PE 12 + PE 14 + PE 12 + PE 1 2 1 2 2 16 - 14 0,5 - 1,5 mm2 single contact 100 VN 02 025 0001 (101) VN 02 025 0001 (102) 20 - 16 contacts on reel 100 ZN 02 025 0001 (1) ZN 02 025 0001 (2) right 2000 HN 02 025 0001 (1) HN 02 025 0001 (2) left 2000 TN 02 025 0001 (1) TN 02 025 0001 (2) 1,5 - 2,5 mm2 single contact 100 VN 02 025 0010 (101) VN 02 025 0010 (102) 16 - 14 contacts on reel 200 ZN 02 025 0010 (1) ZN 02 025 0010 (2) right 2000 HN 02 025 0010 (1) HN 02 025 0010 (2) left 2000 TN 02 025 0010 (1) TN 02 025 0010 (2) Single contact in plastic bag; stamped contact on reel – HN = feeding right side / TN = feeding left side 22 Amphenol Part No. system for crimp contacts VN __ 1) 1) supplied as: 01 _ _ (1) _ 0001 _ 016 5) 4) 2) 3) VN = single contact 100 pcs. ZN = contacts on reel 100 resp. 200 pcs. HN = contacts on reel with 2000 contacts (contact feeding right hand side) TN = contacts on reel with 2000 contacts (contact feeding left hand side) 2) Type of contact: 01 = male contact 02 = female contact 3) Contact Ø: e.g. 016 = 1,6 mm 4) Connection and wire gauge, e.g. 0052: 0,09 - 0,25 mm2 0046: 0,35 - 0,5 mm 2 0047: 0,75 - 1,0 mm 2 5) Plating: Amphenol (1) = silver plated (2) = gold plated (4) = gold plated for high performance 23 C 16-3 Technical Information Termination methods • Screw connection Screw clamps are designed acc. to EN 60999-1 / VDE 609-1. Chart 1 below shows the screw size depending on wire size and the required clamping and testing torque.. This comparison chart allows a cross reference between American Wire Gauge (AWG) and metric wire sizes (mm2). Chart 2 AWG Wire composition Wire diameter Wire size 30 16 1 x 0,25 7 x 0,10 1 x 0,32 7 x 0,13 1 x 0,40 7 x 0,16 19 x 0,10 1 x 0,51 7 x 0,20 19 x 0,13 1 x 0,64 7 x 0,25 19 x 0,16 1 x 0,81 7 x 0,32 19 x 0,20 1 x 1,02 19 x 0,25 19 x 0,29 0,25 mm 0,36 mm 0,32 mm 0,38 mm 0,40 mm 0,48 mm 0,51 mm 0,51 mm 0,61 mm 0,64 mm 0,64 mm 0,76 mm 0,81 mm 0,81 mm 0,97 mm 1,02 mm 1,02 mm 1,27 mm 1,44 mm 0,05 mm2 0,06 mm2 0,08 mm2 0,09 mm2 0,13 mm2 0,14 mm2 0,15 mm2 0,21 mm2 0,23 mm2 0,24 mm2 0,33 mm2 0,36 mm2 0,38 mm2 0,52 mm2 0,56 mm2 0,62 mm2 0,79 mm2 0,96 mm2 1,23 mm2 14 19 x 0,36 1,80 mm 1,95 mm2 12 19 x 0,46 2,29 mm 3,09 mm2 10 37 x 0,40 3,10 mm 4,60 mm2 8 133 x 0,29 4,0 mm 8,80 mm2 6 133 x 0,36 5,5 mm 13,5 mm2 Chart 1 Wire size (mm2) max. 4 Screw size M3 Test torque (Ncm) 50 Diagram 1 below shows the range of tensile strength for a screw connection with a clamp screw M3, fastened with a torque of 50 Ncm, depending on the wire size. 28 26 24 22 Diagram 1 Tensile strength 20 18 Wire gauge It has to be noted that wires of the same AWG number but with different composition have slightly different mm2. Chart 3 Composition and Dimensions of Copper Wires Wire Size Wire Composition Wire diameter 2 12 x 0,10 0,48 mm 0,14 mm2 18 x 0,10 0,50 mm 0,25 mm 2 14 x 0,15 0,70 mm 0,34 mm 2 0,09 mm 0,5 mm2 0,78 mm 1,0 mm 0,75 mm2 24 x 0,20 1,2 mm 1,0 mm2 32 x 0,20 1,4 mm 1,5 mm2 30 x 0,25 1,6 mm 2,5 mm2 35 x 0,30 2,2 mm 2 56 x 0,30 2,8 mm 6,0 mm2 19 x 0,64 3,4 mm 19 x 0,80 4,3 mm 4,0 mm 10 mm 24 7 x 0,25 16 x 0,20 2 Amphenol C 16-3 Technical Information • Crimp connection A crimp connection is a non-detachable electrical connection between a wire and a crimp contact produced with the crimp technology. Precise crimping dies which are matched to the crimp barrel and the wire size and a defined deformation result in a reliable electrical connection. There are open crimp barrels (stamped contacts) and closed crimp barrels (turned contacts). The main advantages of crimp connections are: • Efficient termination of contacts. • Reproducible termination achieve consistent electrical and mechanical results An important point of the quality of a crimp connection is the achieved tensile strength of the termination. Easily measured, the tensile strength is a practible means for quality control purposes. Diagram 2 below shows the required minimum tensile strength for open and closed barrels depending on the wire size. Assembly instructions For crimp contacts use the released crimp tool. The insertion and extraction of crimp contacts shall only be approved with the corresponding insertion / extraction tool. A detailed description of the crimp technology can be found in our crimp tooling catalogues. The requirements for crimp connections are defined in DIN EN 60352-2, IEC 60352-2. Crimp contacts are in this catalogues on page 21 and 22. Diagram 2 N lb 1000 4000 3000 500 400 2000 300 1000 Min. tensile strength N / lb 200 500 400 100 300 50 40 200 30 100 20 50 40 10 30 5 mm2 0,05 AWG 0,1 0,2 28 26 24 22 0,5 20 1,0 1,5 2,5 4,0 6,0 12 10 14 18 16 10,0 8 20 Wire gauge in mm2 / AWG Amphenol 25 C 16-3 Technical Information Chart 5 Degree of protection Electrical devices to which connectors belong to have to be protected for safety reasons from outside influences like dust, foreign objects, direct contact, moisture and water. This protection is provided on industrial connectors by its housings with their latching devices and sealed cable entries. The degree of protection can be selected depending on the type of intended use. The standard IEC 60529 and/or DIN EN 60529 has specified the degree of protection and divided into several classes. The degree of protection is indicated in the following way: IP 65 Code letters (Internat. Protection) 1st charact. numeral (degree of protection against access to hazardous parts and against solid foreign objects) 2nd charact. numeral (degree of protection against ingress of water) 2nd charact. Brief description numeral Definition 0 1 Non-protected Protected against vertically falling water drops – Vertically falling drops shall have no harmful effects. 2 Protected against vertically falling water drops when enclosure tilted up to 15° Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angel up to 15° on either side of the vertical. 3 Protected against spraying water Water sprayed at an angle up to 60° on either side of the vertical shall have no harmful effects. 4 Protected against splashing water Water splashed against the enclosure from any direction shall have no harmful effects. 5 Protected against water jets Water projected in jets against the enclosure from any direction shall have no harmful effects. 6 Protected against powerful water jets Water projected in powerful jets against the enclosure from any direction shall have no harmful effects. 7 Protected against the effects of temporary immersion in water Intrusion of water in quantities causing harmful effects shall not be possible when the enclosure is temporalily immersed in water for 30 min. in 1m depth. 8 Protected against the effects of continous immersion in water Intrusion of water in quantities causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7. 9 K 1) Protected against water during high pressure/steam jet cleaning Water projected in powerful jets with high pressure against the enclosure from any direction shall have no harmful effects. The following charts 4 and 5 give an overview about all protection degrees. Chart 4 1st charact. Brief description numeral Definition 0 1 Non-protected Protected against access to hazardous parts with the back of a hand. Protected against solid foreign objects of ≥50mm Ø. – The probe, sphere of 50mm Ø, shall not fully penetrate and shall have adequate clearance from hazardous parts. Protected against access to hazardous parts with a finger. Protected against solid foreign objects of ≥12,5mm Ø. The jointed test finger of 12mm Ø, 80mm length, shall have adequate clearance from hazardous parts. The probe, sphere of 12,5mm Ø, shall not fully penetrate. 2 3 4 Protected against access to The probe of 1mm Ø shall hazardous parts with a wire. not penetrate at all. Protected against solid foreign objects of ≥1mm Ø. 5 Protected against access to The probe of 1mm Ø shall hazardous parts with a wire. not penetrate. Dust-protected. Intrusion of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the device or to impair safety. 6 26 Protected against access to The probe of 2,5mm Ø shall hazardous parts with a tool. not penetrate at all. Protected against solid foreign objects of ≥2,5mm Ø. Protected against access to The probe of 1mm Ø shall hazardous parts with a wire not penetrate. Dust-tight. No intrussion of dust. 1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code Amphenol C16-3 Remarks Safety classification 1. General Remarks These connectors are designed and produced in conformity with the low voltage directive (73/23/EWG) respectively Gerätesicherheitsgesetz (German law) and are especially in according with the standards DIN EN 61984 / IEC 61984 (VDE 0627); IEC 60664-1 (VSE 0110-1) and IEC 60529. The connectors may be used only within the technical ratings. These connectors with / without breaking capacity are designed and produced according to DIN EN 61984/VDE0627. All technical data refers to mated connectors under live conditions. The safety of the connector system depends on the correct selection of products, proper assembly of the connector device, and a precise fit of the connectors. 2. Application Remarks Connectors with / without breaking capacity must be used according to specified technical ratings. The technical data represents the initial value of mated parts under predetermined conditions and length of time.These values could change with different test parameters or product requirements. The 16-3 Series connectors are used in a wide variety of industries and equipment. Some of these include industrial machines and controls, data processing, instrumentation and test equipment, medical devices, telecommunication’s network and equipment, plus outdoor and marine applications. All rated data for the connectors listed in this catalogues are based on over-voltage category III 1) and pollution degree 3 2) for electronic applications. Connectors were completely mated according to their respective safety locking mechanism. Selection and testing of connectors with / without breaking capacity to meet specific product or industrial requirements such as rated voltage and the related clearances and creepage distances are the responsibility of the user. 3. Assembling Remarks Protection against electrical shock of the termination of the connectors shall be secured by correct mounting. Connectors of the same or different series being mounted side by side may be protected against incorrect mating by the use of coding options. Care must be taken to ensure the parts are correctly mated and screws are tightened with the proper torque. 4. Termination Remarks Cable connectors are effectively secured when using the internal cable clamp. When the connector contains a simple gland bushing for retention without clamping ring the cable should have a strain relief close behind the connector. All cable properties or specifications must be compatible with the connector design and materials. Designated wire conductors must be terminated to the correct poles in the connector. Crimp contacts must be fully inserted into the plastic housing and retention assured with a slight tug on the wire. Wire should be stripped correctly according to printed specifications to insure no electrical contact can be made between the conductors. There should be no nicked or cut strains during the stripping action. 2) 3) X X Female cable connector X X X Male receptacle screw / crimp X 3) X X 3) Female receptacle screw / crimp X 3) X X 3) X X X 3) Cable clamp rewirable X connector with breaking capacity finger safety mated enclosed mated 1) Male cable connector hand back safety mated protective earthing contact X Style finger safety unmated enclosed unmated 5. Safety Classification acc. to DIN EN 61984 / VDE 0627 / IEC 61984 with X X X X X X X X X X X X X X X X X X without Overvoltage category III: Equipment intended for the use in installations or parts of it in which lightning overvoltages do not need to be considered, however switching overvoltages generated by the equipment, and for cases where the reliability and the availability of the equipment or its dependent circuits are subject to special requirements. Examples are protecting means, switches and sockets. Pollution degree 3: Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to be expected. Protection against electrical shock on the termination side has to be secured by proper mounting. Amphenol 27 Summary of Part Numbers Part No. 28 Page Part No. Page Part No. Page Part No. Page C016 00U000 001 1 14 C016 10D015 801 3 19 C016 10G008 000 5 20 C016 10I008 002 1 12 C016 00U000 001 2 17 C016 10D017 002 1 13 C016 10G012 000 2 15 C016 10I008 003 1 12 C016 00U000 011 2 17 C016 10D017 003 1 13 C016 10G014 000 1 13 C016 10I012 003 2 15 C016 00U000 021 1 14 C016 10D017 012 5 19 C016 10G014 000 2 15 C016 10I012 004 2 15 C016 00V000 001 1 14 C016 10D017 013 5 19 C016 10G014 000 5 20 C016 10I012 005 2 15 C016 00V000 001 2 17 C016 10D017 801 3 19 C016 10G015 000 1 13 C016 10I014 002 1 12 C016 00V000 011 2 17 C016 10D019 003 2 16 C016 10G015 000 5 20 C016 10I014 003 1 12 C016 00V000 021 1 14 C016 10D019 004 2 16 C016 10G017 000 1 13 C016 10I014 003 2 15 C016 10C008 000 1 14 C016 10E008 002 1 13 C016 10G017 000 5 20 C016 10I014 004 2 15 C016 10C008 000 5 20 C016 10E008 003 1 13 C016 10G019 000 2 15 C016 10I014 005 2 15 C016 10C012 000 2 16 C016 10E012 003 2 16 C016 10H008 002 1 12 C016 10I015 002 1 12 C016 10C014 000 1 14 C016 10E012 004 2 16 C016 10H008 003 1 12 C016 10I015 003 1 12 C016 10C014 000 2 16 C016 10E012 005 2 16 C016 10H008 012 5 19 C016 10I017 002 1 12 C016 10C014 000 5 20 C016 10E014 002 1 13 C016 10H008 013 5 19 C016 10I017 003 1 12 C016 10C015 000 1 14 C016 10E014 003 1 13 C016 10H008 801 3 19 C016 10I019 003 2 15 C016 10C015 000 5 20 C016 10E014 003 2 16 C016 10H012 003 2 15 C016 10I019 004 2 15 C016 10C017 000 1 14 C016 10E014 004 2 16 C016 10H012 004 2 15 C016 10I019 005 2 15 C016 10C017 000 5 20 C016 10E014 005 2 16 C016 10H014 002 1 12 C016 10K008 002 1 12 C016 10C019 000 2 16 C016 10E015 002 1 13 C016 10H014 003 1 12 C016 10K008 003 1 12 C016 10D008 002 1 13 C016 10E015 003 1 13 C016 10H014 003 2 15 C016 10K012 004 2 15 C016 10D008 003 1 13 C016 10E017 002 1 13 C016 10H014 004 2 15 C016 10K014 002 1 12 C016 10D008 012 5 19 C016 10E017 003 1 13 C016 10H014 005 2 15 C016 10K014 003 1 12 C016 10D008 013 5 19 C016 10E019 003 2 16 C016 10H014 012 5 19 C016 10K014 004 2 15 C016 10D008 801 3 19 C016 10E019 004 2 16 C016 10H014 013 5 19 C016 10K015 002 1 12 C016 10D012 003 2 16 C016 10E019 005 2 16 C016 10H014 801 3 19 C016 10K015 003 1 12 C016 10D012 004 2 16 C016 10F008 002 1 13 C016 10H015 002 1 12 C016 10K017 002 1 12 C016 10D014 002 1 13 C016 10F008 003 1 13 C016 10H015 003 1 12 C016 10K017 003 1 12 C016 10D014 003 1 13 C016 10F012 004 2 16 C016 10H015 012 5 19 C016 10K019 004 2 15 C016 10D014 003 2 16 C016 10F014 002 1 13 C016 10H015 013 5 19 C016 10N008 000 5 20 C016 10D014 004 2 16 C016 10F014 003 1 13 C016 10H015 801 3 19 C016 10N008 006 1 13 C016 10D014 012 5 19 C016 10F014 004 2 16 C016 10H017 002 1 12 C016 10N014 000 5 20 C016 10D014 013 5 19 C016 10F015 002 1 13 C016 10H017 003 1 12 C016 10N014 006 1 13 C016 10D014 801 3 19 C016 10F015 003 1 13 C016 10H017 012 5 19 C016 10N015 000 5 20 C016 10D015 002 1 13 C016 10F017 002 1 13 C016 10H017 013 5 19 C016 10N015 006 1 13 C016 10D015 003 1 13 C016 10F017 003 1 13 C016 10H017 801 3 19 C016 10N017 000 5 20 C016 10D015 012 5 19 C016 10F019 004 2 16 C016 10H019 003 2 15 C016 10N017 006 1 13 C016 10D015 013 5 19 C016 10G008 000 1 13 C016 10H019 004 2 15 C016 20C005 100 2 16 Amphenol Summary of Part Numbers Part No. Page Part No. Page Part No. Page Part No. Page C016 20D005 103 2 16 HN 02 016 0002 (1) 22 TN 02 016 0005 (2) 22 ZN 01 015 0046 (1) 21 C016 20D005 104 2 16 HN 02 016 0002 (2) 22 TN 02 025 0001 (1) 22 ZN 01 015 0046 (2) 21 C016 20E005 103 2 16 HN 02 016 0003 (1) 22 TN 02 025 0001 (2) 22 ZN 01 015 0047 (1) 21 C016 20E005 104 2 16 HN 02 016 0003 (2) 22 TN 02 025 0010 (1) 22 ZN 01 015 0047 (2) 21 C016 20E005 105 2 16 HN 02 016 0005 (1) 22 TN 02 025 0010 (2) 22 ZN 01 015 0052 (1) 21 C016 20F005 104 2 16 HN 02 016 0005 (2) 22 VN 01 015 0046 (1) 21 ZN 01 015 0052 (2) 21 C016 20G005 100 2 15 HN 02 025 0001 (1) 22 VN 01 015 0046 (2) 21 ZN 01 016 0002 (1) 21 C016 20H005 103 2 15 HN 02 025 0001 (2) 22 VN 01 015 0047 (1) 21 ZN 01 016 0002 (2) 21 C016 20H005 104 2 15 HN 02 025 0010 (1) 22 VN 01 015 0047 (2) 21 ZN 01 016 0003 (1) 21 C016 20I005 103 2 15 HN 02 025 0010 (2) 22 VN 01 015 0052 (1) 21 ZN 01 016 0003 (2) 21 C016 20I005 104 2 15 TN 01 015 0046 (1) 21 VN 01 015 0052 (2) 21 ZN 01 016 0005 (1) 21 C016 20I005 105 2 15 TN 01 015 0046 (2) 21 VN 01 016 0002 (1) 21 ZN 01 016 0005 (2) 21 C016 20K005 104 2 15 TN 01 015 0047 (1) 21 VN 01 016 0002 (2) 21 ZN 01 025 0001 (1) 21 FH 0000-016 14 TN 01 015 0047 (2) 21 VN 01 016 0003 (1) 21 ZN 01 025 0001 (2) 21 FH 0002-016 17 TN 01 015 0052 (1) 21 VN 01 016 0003 (2) 21 ZN 01 025 0010 (1) 21 HN 01 015 0046 (1) 21 TN 01 015 0052 (2) 21 VN 01 016 0005 (1) 21 ZN 01 025 0010 (2) 21 HN 01 015 0046 (2) 21 TN 01 016 0002 (1) 21 VN 01 016 0005 (2) 21 ZN 02 015 0046 (1) 22 HN 01 015 0047 (1) 21 TN 01 016 0002 (2) 21 VN 01 025 0001 (101) 21 ZN 02 015 0046 (2) 22 HN 01 015 0047 (2) 21 TN 01 016 0003 (1) 21 VN 01 025 0001 (102) 21 ZN 02 015 0047 (1) 22 HN 01 015 0052 (1) 21 TN 01 016 0003 (2) 21 VN 01 025 0010 (101) 21 ZN 02 015 0047 (2) 22 HN 01 015 0052 (2) 21 TN 01 016 0005 (1) 21 VN 01 025 0010 (102) 21 ZN 02 015 0052 (1) 22 HN 01 016 0002 (1) 21 TN 01 016 0005 (2) 21 VN 02 015 0046 (1) 22 ZN 02 015 0052 (2) 22 HN 01 016 0002 (2) 21 TN 01 025 0001 (1) 21 VN 02 015 0046 (2) 22 ZN 02 016 0002 (1) 22 HN 01 016 0003 (1) 21 TN 01 025 0001 (2) 21 VN 02 015 0047 (1) 22 ZN 02 016 0002 (2) 22 HN 01 016 0003 (2) 21 TN 01 025 0010 (1) 21 VN 02 015 0047 (2) 22 ZN 02 016 0003 (1) 22 HN 01 016 0005 (1) 21 TN 01 025 0010 (2) 21 VN 02 015 0052 (1) 22 ZN 02 016 0003 (2) 22 HN 01 016 0005 (2) 21 TN 02 015 0046 (1) 22 VN 02 015 0052 (2) 22 ZN 02 016 0005 (1) 22 HN 01 025 0001 (1) 21 TN 02 015 0046 (2) 22 VN 02 016 0002 (1) 22 ZN 02 016 0005 (2) 22 HN 01 025 0001 (2) 21 TN 02 015 0047 (1) 22 VN 02 016 0002 (2) 22 ZN 02 025 0001 (1) 22 HN 01 025 0010 (1) 21 TN 02 015 0047 (2) 22 VN 02 016 0003 (1) 22 ZN 02 025 0001 (2) 22 HN 01 025 0010 (2) 21 TN 02 015 0052 (1) 22 VN 02 016 0003 (2) 22 ZN 02 025 0010 (1) 22 HN 02 015 0046 (1) 22 TN 02 015 0052 (2) 22 VN 02 016 0005 (1) 22 ZN 02 025 0010 (2) 22 HN 02 015 0046 (2) 22 TN 02 016 0002 (1) 22 VN 02 016 0005 (2) 22 HN 02 015 0047 (1) 22 TN 02 016 0002 (2) 22 VN 02 025 0001 (101) 22 HN 02 015 0047 (2) 22 TN 02 016 0003 (1) 22 VN 02 025 0001 (102) 22 HN 02 015 0052 (1) 22 TN 02 016 0003 (2) 22 VN 02 025 0010 (101) 22 HN 02 015 0052 (2) 22 TN 02 016 0005 (1) 22 VN 02 025 0010 (102) 22 Amphenol 29 30 Amphenol Amphenol 31 International Argentina Amphenol Argentina Av. Callao 930 2nd Floor Office B “Plaza“ C1023 AAP Buenos Aires Phone +54 / 11 / 4815 68 86 Fax +54 / 11 / 4814 57 79 Hong Kong Amphenol East Asia Limited Units 2201-02, Railway Plaza 39 Chatham Road South Tsimshatsui, Kowloon Phone +852 / 2699 / 2663 Fax +8 52 / 26 88 / 09 74 Australia Amphenol Australia Ltd. 2 Fiveways Blvd Keysborough Victoria 31 73 Phone +61 / 3 / 8796 / 8888 Fax +61 / 3 / 8796 / 8801 India Amphetronix Limited Plot No. 105 Bhosari Industrial Area Pune - 411 026 Phone +91 / 20 / 27121418 Fax +91 / 20 / 27120581 Belgium Amphenol-Tuchel Belgium Brusselbaan 524b B 1600 Sint-Pieters-Leeuw Phone +32 / 2377 / 2549 Fax +32 / 2377 / 5303 Brasilia Amphenol do Brasil Ltda. Rua Diogo Moreira 132, 20th Floor CEP 05423-010 Sao Paulo SP Phone +55 / 11 / 3815.1003 Fax +55 / 11 / 3815.1629 China Amphenol-Tuchel Electronics GmbH China Branch 210-1 Taishan Road Changzhou 213022 Phone +86 / 0519 / 5110301 Fax +86 / 0519 / 5110299 ATE 2020 B 0406 3.000 Printed on chlorin-free bleached paper, specifications may be changed without notice. Copyright 04/06 by Amphenol-Tuchel Electronics GmbH, Germany France Amphenol-Tuchel France Bât. Le Newton C 7 Mail B. Thimonnier 77185 Lognes Phone +33 / 164627676 Fax +33 / 164627677 Germany Amphenol-Tuchel Electronics GmbH August-Haeusser-Str. 10 74080 Heilbronn Phone +49 / 7131 / 929-0 Fax +49 / 7131 / 929-486 Great Britain Amphenol-Tuchel Great Britain 14 Plover Close Kempshott, Basingstoke Hants, RG22 5PQ Phone +44 / 1256 / 330749 Fax +44 / 1256 / 330749 Italy Amphenol-Tuchel Italy Via Barbaiana n. 5 l-20020 Lainate (MI) Phone +39 / 2 / 932 541 Fax +39 / 2 / 932 54444 Japan Amphenol Japan, K.K. 2-3-27, Kudan Minami Chiyoda-Ku Tokyo 102 Phone +81 / 3 / 3263 / 5611 Fax +81 / 3 / 5276 / 7059 Korea Amphenol DaeShin Limited #802 Joong-Dong 1131-5 Wonmi-Ku Bucheon-City Kyunggi-Do Korea 420-020 Phone +82 / 2 / 785 / 1588 Fax +82 / 2 / 589 / 1514 Mexico Amphenol Mexico Prolongacion Reforma 61 - 6 B2 Col. Paseo de las Lomas C.P. 01330 Mexico D.F. Phone +52 / 55 / 5258.9984 Fax +52 / 55 / 5081.6890 Spain Amphenol-Tuchel Spain Ctra Sabadell a Mollet, km 4.5 Nave 5 08130 Santa Perpetua de Mogoda (Barcelona) Phone +34 / 93 / 574.41.34 Fax +34 / 93 / 574.10.09 Sweden Amphenol-Tuchel Scandinavia P.O. Box 20 SE 195 42 Märsta Phone +46 / 8 591 / 175 76 Fax +46 / 8 591 / 175 76 Taiwan Amphenol East Asia Ltd. Taiwan Branch (H.K.) 116 Zhong Shan Road Lane 956 Taoyuan City Taiwan R.O.C. 330 Phone +886 / 3 / 370 / 7855 Fax +886 / 3 / 360 / 7259 Turkey Amphenol Turkiye Ayazaga Mah. Meydan Sk. No. 28 Beybi Giz Plaza, Kat. 26 34396 Maslak/Istanbul Phone +90 / 0212 / 3352501 Fax +90 / 0212 / 3352500 USA Amphenol-Tuchel Electronics 6900 Haggerty Road Suite 200 Canton, Michigan 48187 Phone +1 / 734 / 4516400 Fax +1 / 734 / 451 7197 Amphenol Corporation Corporate Headquarters 358 Hall Avenue Wallingford, CT 06492 Phone +1 / 800 / 380 8052 Phone +1 / 2 03 / 2 65 / 89 00 Fax +1 / 2 03 / 2 65 / 86 28 Singapore Amphenol East Asia Limited Asia Pacific Sales Operation Singapore Branch 300 Beach Road #25-07 The Concourse Singapore 199555 Phone +27 / 11 / 305-9574 Fax +27 / 11 / 305-9576 South Africa Amphenol International Ltd Chislehurston 30 Impala Road Chislehurston Sandton, 2146 Phone +27 / 11 / 7839517 Fax +27 / 11 / 7839519 Your engineering sales representative: Amphenol Amphenol-Tuchel Electronics GmbH 32 Amphenol August-Haeusser- Str. 10 . D-74080 Heilbronn . Germany . Phone +49 (0) 71 31/ 9 29-0 . Fax +49 (0) 71 31/ 9 29-486 · www.amphenol.info Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Amphenol: VN02 016 0003 1 VN02 016 0002 1 VN01-015-0047-2 VN01 016 0015 1 VN01-016-0011-2 VN02-016-0002-2 VN02-016-0003-2 VN01 016 0011 1 VN01 016 0004 1 VN01 025 0010 101 VN02 025 0001 101 C016-10H012-003-2 VN01-016-0005-2 VN02-016-0005-2 ZN0101500521 TN0202500011 ZN0201500522 VN0201500472 TN0101500471 ZN0101500472 HN0201600052 HN0101500521 ZN0201500462 ZN0101500471 HN0201600022 HN0101600021 TN0102500101 TN0201500522 HN0201600051 VN0101500522 TN0101600051 HN0101600052 TN0201500521 HN0201500471 HN0101500522 HN0201500472 TN0101500522 HN0201600031 TN0101600031 HN0201500461 HN0101600022 VN0201500521 HN0101600051 HN0201500522 TN0102500011 TN0201600051 TN0201500461 HN0101600032 VN0101500521 ZN0101500522 TN0201500462 ZN0201500471 TN0101500472 TN0101500462 TN0101500521 HN0201600032 TN0201600032 ZN0201500472 VN0201500522 ZN0201500521 TN0201600022 TN0201500472 TN0101500461 HN0101600031 HN0201500521 TN0202500101 TN0201600021 TN0201600031 TN01 015 0052 2 TN02 015 0046 2 TN01 015 0047 2 ZN02 015 0046 2 TN01 015 0047 1 TN02 015 0047 2 ZN01 015 0047 2 VN01 015 0052 2 TN02 015 0052 2 VN01 015 0047 2 HN02 015 0052 2 ZN02 015 0047 2 TN02 015 0052 1 TN01 015 0046 2 HN02 015 0052 1 ZN02 015 0047 1 ZN01 015 0052 1 VN02 015 0047 2 VN01 015 0052 1 HN02 015 0047 1 HN01 015 0052 2 ZN02 015 0052 2 HN01 015 0052 1 ZN02 015 0052 1 HN02 015 0047 2 TN01 015 0046 1 ZN01 015 0047 1 TN02 015 0046 1 HN02 015 0046 1 ZN01 015 0052 2 TN01 015 0052 1 VN01 016 0011 2
ZN0201500522 价格&库存

很抱歉,暂时无法提供与“ZN0201500522”相匹配的价格&库存,您可以联系我们找货

免费人工找货