Amphenol
Amphenol-Tuchel Electronics GmbH
Series C 16-3®
Circular Connectors
The Company
Amphenol-Tuchel Electronics GmbH is a member of the USA based Amphenol
Corporation. With our own global presence we offer our customers exceptional
technical support and worldwide service in the areas of development, production
and distribution. Amphenol-Tuchel Electronics GmbH has a successful history
as a partner to our customers and sets standards for connector technology.
Quality
From the beginning of the development process, Amphenol-Tuchel Electronics
GmbH gives quality considerations the top priority. Meeting customer requirements is
the main focus of the product development process.
Interdisciplinary project teams with diverse backgrounds from marketing,
product engineering and production guarantee the development and production
of robust and reliable connector solutions.
Our quality assessment begins with the initial contact to the customer and
extends through the life of the product. A satisfied customer is the measure of
our success.
We strive to use environmentally friendly processes that minimize the waste of
natural resources and introduction of toxins into the environment.
Certifications:
General information
We reserve the right to change the design due
to improvement in quality, development or
production requirements.
TS 16949
ISO 14001
ISO 9000:2000
This catalogue must not be used in any
form or manner without our prior approval
in writing (Copyright Law, Fair Trading Law,
Civil Code).
This release replaces all former releases.
2
Amphenol
Content
Page
General information
Serie C 16-3
2
Product description
4
Order information
Approvals
5
Coding system
6
Technical data
7
Derating curves
9
View of connector style
10
Assembly instructions
11
Shell size 1
Male cable connectors
12
Female receptacles
Female cable connectors
13
Male receptacles
Accessories
14
Shell size 2
Male cable connectors
Female receptacles
15
Female cable connectors
Male receptacles
16
Accessories
17
EMV versions
18
Crimp contacts pin
21
Crimp contacts socket
22
Part No. system for crimp contacts
23
Technical Information
24
Remarks / Safety classification
27
Summary of Part Numbers
28
Amphenol
3
C 16-3
Product description
The circular connector series C 16-3 has two housing sizes. The
connectors are designed to meet the high requirements of industrial
applications under harsh environmental conditions. The range includes
versions with screw and crimp terminations. A selection of crimp contacts
for hand crimp tools and crimp machines enables a reliable termination
reluting in qualitative, technical and economical advantages. A board
selection of housing styles are available.
On choosing the housing style and shell size please take both the cable
diameter and wire gauge into consideration. If neccessary one should use
the long housing versions.
4
Main features and advantages:
• Circular connectors for power and signal applications with following
contact arrangements:
Shell size 1: 8 + PE, 14 + PE, 17 + PE , 12 + 3 + PE
Shell size 2: 5 + PE, 12 + PE, 14 + PE, 19 + PE
•For applications in machine tools, measurement and control, process
technology and medical equipment
• Housing are made from high grade plastic material.
•Vibration safe connection by solid bayonet coupling with lock
in positon.
• Cable housing straight or right-angled with various cable outlets
•Protection degree IP 65 in mated position.
•Internal cable clamp or clamping ring provides a safe cable restrain.
Amphenol
C 16-3
Product description
Order information
Approvals
Order information
Colour coding
Upon request the coupling ring of the plugs and the housing of the
receptacles can be delivered in the colour red, green, blue, yellow and grey.
Crimp version
Order numbers do not include crimp contacts. Please order separately
(page 21 / 22)
Polarization
Depending on the contact arrangements the polarization of this connector
series can be varied. The contact inserts can be mounted in alternate
positions. The order number in the catalogue refers always to postition 1.
The postition of the contact inserts can also be changed by the customer
using a disassembly tool ( see page 14 and 17) to remove the insert and
remount it in the required position ( see page 6)
Crimp tooling
Ask for our catalogue “Tools”.
Testhouse
Approvals
Approval No.
VDE
3964
UL 1)
E 63093
CSA
49932-9
In general approvals refer to representative versions of the connector series. Test report upon request.
Please refer to the „Conditions of Acceptability“.
1)
Amphenol
5
C 16-3
Coding system
Polarization
Depending on the contact arrangements the polarization of this connector series can be varied. Please take care of the housing and
contact insert characteristics.
Shell size 1
Shell size 2
No of contacts
No of coding possibil. Position
No of contacts
No of coding possibil. Position
8 + PE
4
1, 3, 5, 7
5 + PE
6
1, 2, 3, 4, 6, 7
14 + PE
7
1, 2, 3, 4, 5, 6, 7
14 + PE
7
1, 2, 3, 4, 5, 6, 7
17 + PE
6
1, 2, 3, 4, 5, 7
12 + PE
7
1, 2, 3, 4, 5, 6, 7
12 + 3 + PE
4
1, 3, 5, 7
19 + PE
6
1, 3, 4, 5, 6, 7
Coding point on the shell
Coding point on the contact insert
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pin contact insert termination side
Pos. 5
Pos. 6
Pos. 7
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Socket contact insert termination side
Pos. 5
Pos. 6
Pos. 7
Disassembly of contact inserts with disassembly tool (see page 14 and 17)
Pin or socket contact insert
Disassembly tools: shell size 1: see page 14
shell size 2: see page 17
6
Amphenol
C 16-3
Technical data
Shell size 1
General Characteristics
Standard
Technical data
Shell size 1
8 + PE
14 + PE
17 + PE
12 + 3 + PE
DIN EN 60664-1 1)
400 V
100 V
100 V
3 x 320 V, 12 x 24 V
UL 1977, CSA 22.2
Number of contacts
Electrical Characteristics
Rated voltage
400 V
3 x 250 V, 11 x 250 V
250 V
3 x 250 V, 12 x 24 V
DIN EN 60664-1
1)
6000 V
3000 V
3000 V
3 x 4000 V, 12 x 800 V
Pollution degree
DIN EN 60664-1
1)
3
3
3
3
Installation (overvoltage) category
DIN EN 60664-1 1)
III
III
III
III
Material group
DIN EN 60664-1 1)
II
II
II
II
Current carrying capacity
DIN EN 60512-5-2,
test 5b
12 A
3 x 16 A, 11 x 6 A
6A
3 x 12 A, 12 x 6 A
UL 1977, CSA 22.2
10 A
3 x 12 A, 11 x 4 A
5A
3 x 10 A, 12 x 5 A
≤ 22 N
≤ 25 N
Rated impulse withstand voltage
≥ 10 Ω
DIN EN 60512-3-1,
test 3a
DIN EN 60512-2-1,
test 2a
Insulation resistance
Contact resistance
8
≤ 5 mΩ
Climatic Characteristics
Climatic category
DIN EN 60068-1
40 / 125 / 56
Operating temperature
-40°C ... +125°C
Mechanical Characteristics
Degree of protection
DIN EN 60529
Insertion and withdrawal force
DIN EN 60512-13-2,
test 13b
IEC 60512,
test 9a
Mechanical operation
IP 65
≤ 25 N
≤ 30 N
≥ 500 mating cycles
Materials
Housing material
Polyamide 6.6
Dielectric material
Polyamide 6.6
Gasket material
Neoprene
Contact plating
silver plated / gold plated
Other Characteristics
Termination technique
crimp
Wire gauge / AWG
Flammability
Locking system
0,14 - 2,5 mm2 /
26 - 14
UL 94
0,09 - 1,0 mm2 /
28 - 18
0,09 - 2,5 mm2 /
28 - 14
VO
bayonet
1)
Amphenol
0,09 - 2,5 mm2 /
28- 14
DIN 60664-1 =^ VDE 0110-1 =^ DIN EN 60664-1
The stated technical values refer to the use as connector.
If these components are used as plug and socket device a reduced current carrying capacity has to be considered.
7
C 16-3
Technical data
Shell size 2
General Characteristics
Technical data
Standard
Shell size 2
5 + PE
12 + PE
14 + PE
19 + PE
DIN EN 60664-1 1)
400 V
3 x 500 V, 9 x 300 V
400 V
250 V
UL 1977, CSA 22.2
400 V
3 x 400 V, 9 x 250 V
10 x 400 V, 4 x 250 V
250 V
6000 V
3 x 6000 V, 9 x 4000 V
6000 V
4000 V
Number of contacts
Electrical Characteristics
Rated voltage
1)
Rated impulse withstand voltage
DIN EN 60664-1
Pollution degree
DIN EN 60664-1 1)
3
3
3
3
Installation (overvoltage) category
DIN EN 60664-1 1)
III
III
III
III
Material group
DIN EN 60664-1 1)
II
II
II
II
Current carrying capacity
DIN EN 60512-5-2,
test 5b
21 A
3 x 21 A, 9 x 11 A
4 x 6 A, 10 x 12 A
6A
UL 1977, CSA 22.2
16 A
3 x 10 A, 9 x 5 A
10 x 10 A, 4 x 5 A
5A
Insulation resistance
Contact resistance
≥ 10 Ω
DIN EN 60512-3-1,
test 3a
DIN EN 60512-2-1,
test 2a
8
≤ 5 mΩ
Climatic Characteristics
Climatic category
DIN EN 60068-1
40 / 100 / 56
Operating temperature
40 / 125 / 56
-40°C ... +125°C (5+PE: +100°C)
Mechanical Characteristics
Degree of protection
DIN EN 60529
Insertion and withdrawal force
DIN EN 60512-13-2,
test 13b
DIN EN 60512-9-1,
test 9a
Mechanical operation
IP 65
≤ 15 N
≤ 25 N
≤ 30 N
≤ 25 N
≥ 500 mating cycles
Materials
Housing material
Polyamide 6.6
Dielectric material
Poliamide 6.6
Gasket material
Neoprene
Contact plating
silver plated/ gold plated
Other Characteristics
Termination technique
screw
Wire gauge / AWG
Flammability
Locking system
8
4 mm2 /
10
UL 94
crimp
0,09 - 2,5 mm2 /
28 - 14
0,09 - 2,5 mm2 /
28 - 14
0,09 - 1,0 mm2 /
28 - 18
VO
bayonet
1)
DIN EN 60664-1 =^ VDE 0110-1 =^ IEC 60664-1
The stated technical values refer to the use as connector.
If these components are used as plug and socket device a reduced current carrying capacity has to be considered.
Amphenol
C 16-3
Derating curves
Shell size 1
8+PE
8+PE
a)
Kon
a) alle
all contacts
Ø 1,6
Anschlu
wire gauge 1,5 mm 2
all cont
wire gau
16
14
12
10
8
6
4
2
0
10 20 30 40 50 60 70 80 90 100 110 120
A
Current carrying capacity
Current carrying capacity
A
°C
a
20
15
10
0
10 20 30 40 50 60 70 80 90 100 110 120
°C
12+3+PE
12+3+PE
4 contacts
a) alle
Kont Ø 1,6
wire gauge 1,5 mm 2
Anschluß
b)
12 contacts
b) alle
Kont Ø 1,5
wire gauget 0,5 mm 2
Anschluß
A
Current carrying capacity
Current carrying capacity
0
10 20 30 40 50 60 70 80 90 100 110 120
Ambient temperature
17+PE
17+PE
all contacts
Ø 1,5
alle
Kon
wire
gauge
0,5
mm 2
Anschlu
all conta
wire gau
10
9
8
7
6
5
4
3
2
1
b
5
Ambient temperature
A
14+PE
14+PE
a)
contacts Ø 2,5
a) 44 Kon
wire gauge 1,5 mm 2
Ansch
b) 411con
contacts Ø 1,5
wire
wire ggauge 0,5 mm 2
b) 11 Ko
Ansch
11 con
wire g
16
14
12
10
8
6
4
2
0
°C
Ambient temperature
a
b
10 20 30 40 50 60 70 80 90 100 110 120
°C
Ambient temperature
Shell size 2
5+PE
5+PE
a) alle
all contacts
Ø 2,0
Ko
Ansch
wire gauge 4,0 mm 2
b) all
all con
contacts Ø 2,0
wire ga
wire gauge 2,5 mm 2
b) alle Ko
Ansch
all con
wire ga
0
10 20 30 40 50 60 70 80 90 100 110 120
A
Current carrying capacity
Current carrying capacity
A
36
33
30
27
24
21
18
15
12
9
6
3
°C
30
25
20
15
5
0
15
10
a
b
5
0
10 20 30 40 50 60 70 80 90 100 110 120
Ambient temperature
Amphenol
10 20 30 40 50 60 70 80 90 100 110 120
°C
Ambient temperature
14+PE
14+PE
a)
contacts Ø 1,6
a) 11
11 Ko
Ansch
wire gauge 1,5 mm 2
co
b) 11
4 contacts
Ø 1,5
wire g
wire gauge 0,5 mm 2
b) 4 Kon
Ansch
4 con
wire g
°C
A
Current carrying capacity
Current carrying capacity
20
b
10
Ambient temperature
A
a
12+PE
12+PE
a) 34 Kon
contacts Ø 2,5
Ansc
wire gauge 2,5 mm 2
b) 39 con
contacts Ø 1,6
wire g
wire gauge 2,5 mm 2
b) 9 Kon
Ansc
9 con
wire g
19+PE
19+PE
all
Ø 1,5
allecontacts
Kon
wire
gauge 0,5 mm 2
Anschlu
all conta
wire gau
12
11
10
9
8
7
6
5
4
3
2
1
0
10 20 30 40 50 60 70 80 90 100 110 120
°C
Ambient temperature
9
C 16-3
Male cable connector,
Shell size 1 and 2
Identification
Male cable connector
Figure
Description
Conn. Style
Long version with internal
cable clamp
Page
Size 1
Size 2
12
15
12
15
12
15
13
16
13
16
13
16
13
15
13
–
14
16
I
Short version,
with clamping ring
H
Right -angled,
with clamping ring
K
Female cable connector
Long version with internal
cable clamp
E
Short version,
with clamping ring
D
Right-angled,
with clamping ring
F
Female receptacle
Flange mounting,
with mounted gasket
G
Panel mounting with ring
nut, with gasket
N
Male receptacle
Flange mounting,
with mounted gasket
C
10
Amphenol
C 16-3
Assembly instructions
Shell size 1 and 2
Torque for back shell and cable screw
min. 1 Nm
max. 2 Nm
clamping
ring
short back shell
cable nut
sealing
gasket
long back shell
metal washer
internal strain relief
male insert with
locking ring
right-angled back shell
tightening torque 0,5 Nm
female insert with
locking ring
Shinning lengths
Screw contacts
Crimp contacts
0,09 - 0,25 mm2
0,35 - 0,50 mm2
0,50 - 2,50 mm2
1)
Amphenol C 16-3
+1
7,0 mm
3 +0,5 mm
3 +0,5 mm
3,5 +1 mm
1)
Remarks:
The dimensions are for general information only and
can vary depending on cable styles and types.
Please make sure that the usability of the cable in
conjunction with the clamping ring is given.
end splice recommended
Amphenol
11
C 16-3
Shell size 1
Male cable connectors
I
Description
H
Drawing
No. of
cont.
K
Contacts2)
Part No.
Cable outlet
Ø 10 -12
8 + PE
Male cable connector for crimp
contacts, long, style I with internal
cable clamp, without contacts 1)
Ø 12 -14
.N 01 016 00... C016 10I008 002 1 C016 10I008 003 1
14 + PE 11 x
C016 10I014 002 1 C016 10I014 003 1
.N 01 015 00...
4x
.N 01 025 00...
C016 10I015 002 1 C016 10I015 003 1
12+3+PE 12 x
.N 01 015 00...
4x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10I017 002 1 C016 10I017 003 1
Cable outlet
Ø 8 -10
Male cable connector for crimp
contacts, short, style H with
clamping ring, without contacts 1)
Ø 10 -12
8 + PE .N 01 016 00... C016 10H008 002 1 C016 10H008 003 1
2)
14 + PE 11 x
C016 10H014 002 1 C016 10H014 003 1
.N 01 015 00...
4x
.N 01 025 00...
C016 10H015 002 1 C016 10H015 003 1
12+3+PE 12 x
.N 01 015 00...
4x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10H017 002 1 C016 10H017 003 1
Male cable connector for crimp
contacts, style K with clamping
ring, without contacts 1)
8 + PE .N 01 016 00... C016 10K008 002 1 C016 10K008 003 1
14 + PE 11 x
C016 10K014 002 1 C016 10K014 003 1
.N 01 015 00...
4x
.N 01 025 00...
12+3+PE 12 x
C016 10K015 002 1 C016 10K015 003 1
.N 01 015 00...
4x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10K017 002 1 C016 10K017 003 1
1)
Please order crimp contacts separately, see page 21/22.
12
2)
Part No system for crimp contacts, see page 23.
Amphenol
G
Description
Drawing
28,6 ±0,1
(1.126)
Ø 26,2 +0,2
(1.031)
oder M3,5
Ø 3,8 +0,1
(.15)
Shell size 1
Female receptacles
30,2 +0,2
(1.189)
28,6 ±0,1
(1.126)
C 16-3
SW27,2 +0,2
(1.071)
N
Panel cutout
No. of
cont.
8 + PE
Female receptacle for crimp
contacts, style G,
without contacts 1)
Contacts 2)
.N 02 016 00…
14 + PE
11 x .N 02 015 00...
4 x .N 02 025 00...
12 + 3 + PE 12 x .N 02 015 00...
4 x .N 02 016 00...
Female receptacle for crimp
contacts, style N,
without contacts 1)
Panel cutout
Part No.
C016 10G008 000 1
C016 10G014 000 1
C016 10G015 000 1
17 + PE
.N 02 015 00...
C016 10G017 000 1
8 + PE
.N 02 016 00...
C016 10N008 006 1
11 x .N 02 015 00...
4 x .N 02 025 00...
12 +3+ PE 12 x .N 02 015 00...
4 x .N 02 016 00...
14 + PE
17 + PE
.N 02 015 00...
C016 10N014 006 1
C016 10N015 006 1
C016 10N017 006 1
C 16-3
Shell size 1
Female cable connectors
E
Description
Drawing
D
No. of
cont.
F
Contacts 2)
Part No.
Cable outlet
Ø 10-12
Ø 12-14
8 + PE .N 02 016 00.. C016 10E008 002 1 C016 10E008 003 1
14 + PE 11 x .N 02 015 00... C016 10E014 002 1 C016 10E014 003 1
4 x .N 02 025 00..
12+3+PE 12 x .N 02 015 00... C016 10E015 002 1 C016 10E015 003 1
4 x .N 02 016 00...
17 + PE .N 02 015 00... C016 10E017 002 1 C016 10E017 003 1
Female cable connector for
crimp contacts, long, style E
with internal strain relief,
without contacts 1)
Cable outlet
Ø 8-10
8 + PE
Female cable connector for
crimp contacts, short, style D
with clamping ring,
without contacts 1)
Ø 10-12
.N 02 016 00... C016 10D008 002 1 C016 10D008 003 1
14 + PE 11 x .N 02 015 00... C016 10D014 002 1 C016 10D014 003 1
4 x .N 02 025 00...
12+3+PE 12 x .N 02 015 00... C016 10D015 002 1 C016 10D015 003 1
4 x .N 02 016 00...
17 + PE .N 02 015 00... C016 10D017 002 1 C016 10D017 003 1
8 + PE
Female cable connector for
crimp contacts, style F
with clamping ring,
without contacts 1)
.N 02 016 00... C016 10F008 002 1 C016 10F008 003 1
14 + PE 11 x .N 02 015 00... C016 10F014 002 1 C016 10F014 003 1
4 x .N 02 025 00...
12+3+PE 12 x .N 02 015 00... C016 10F015 002 1 C016 10F015 003 1
4 x .N 02 016 00...
17 + PE .N 02 015 0005 C016 10F017 002 1 C016 10F017 003 1
1)
Please order crimp contacts separately, see page 21/22.
Amphenol
2)
Part No system for crimp contacts, see page 23.
13
Description
Drawing
No. of
cont.
Male receptacle for crimp
contacts, style C,
without contacts 1)
Ø 26,2 +0,2
(1.031)
oder M3,5
C
Ø 3,8 +0,1
(.15)
Shell size 1
Male receptacles
28,6 ±0,1
(1.126)
28,6 ±0,1
(1.126)
C 16-3
Panel cutout
Contacts 2)
Part No.
.N 01 016 00...
C016 10C008 000 1
8 + PE
.N 01 016 00...
C016 10C008 000 1
14 + PE
11 x .N 01 015 00...
4 x .N 01 025 00...
C016 10C014 000 1
12 + 3 + PE 12 x .N 01 015 00...
4 x .N 01 016 00...
C016 10C015 000 1
17 + PE
.N 01 015 00...
C016 10C017 000 1
C 16-3
Shell size 1
Accessories
Description
Part No.
Drawing
for male cable connector
Protective cap for male cable
connector and male receptacle
C016 00U000 001 1
for male cable connector
Protective cap for female cable
connector and female receptacle
C016 00V000 001 1
Disassembly tool for pin- and
socket inserts
1)
Please order crimp contacts separately, see page 21/22.
14
for male receptacle
C016 00U000 021 1
for male receptacle
C016 00V000 021 1
FH 0000-016
2)
Part No system for crimp contacts, see page 23.
Amphenol
C 16-3
Shell size 2
Male cable connectors
I
Description
Drawing
H
K
Contacts 2)
No. of
cont.
Ø 12-14
5 + PE
Male cable connector, long,
style I with internal strain relief,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
12 + PE
9 x .N 01 016 00... C016 10I012 003 2 C016 10I012 004 2 C016 10I012 005 2
4 x .N 01 025 00...
14 + PE
4 x .N 01 015 00... C016 10I014 003 2 C016 10I014 004 2 C016 10I014 005 2
11 x .N 01 016 00...
19 + PE
.N 01 015 000...
5 + PE
Male cable connector,
style K with clamping ring,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
Ø 19-21
C016 20I005 103 2 C016 20I005 104 2 C016 20I005 105 2
–
C016 10I019 003 2 C016 10I019 004 2 C016 10I019 005 2
Ø 10-12
Male cable connector, short,
style H with clamping ring,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
Part No.
Cable outlet 3)
Ø 14-16
Cable outlet
Ø 12-14
Ø 14-18
C016 20H005 103 2 C016 20H005 104 2
–
12 + PE
9 x .N 01 016 00... C016 10H012 003 2 C016 10H012 004 2
4 x .N 01 025 00...
–
14 + PE
4 x .N 01 015 00... C016 10H014 003 2 C016 10H014 004 2 C016 10H014 005 2
11 x .N 01 016 00...
19 + PE
.N 01 015 00...
5 + PE
–
–
C016 10H019 003 2 C016 10H019 004 2
–
–
C016 20K005 104 2
–
12 + PE
9 x .N 01 016 00...
4 x .N 01 025 00...
–
C016 10K012 004 2
–
14 + PE
4 x .N 01 015 00...
11 x .N 01 016 00...
–
C016 10K014 004 2
–
19 + PE
.N 01 015 00...
–
C016 10K019 004 2
–
C 16-3
Ø
Shell size 2
Female receptacle
Ø
G
Description
Drawing
No. of cont.
Female receptacle, style G,
5 + PE screw termination,
12 + PE-, 14 + PE and
19 + PE version without contacts 1)
1)
Please order crimp contacts separately, see pag 21/22.
Amphenol
5 + PE
2)
Contacts 2)
–
Panel cutout
Part No.
C016 20G005 100 2
12 + PE
9 x .N 02 016 00…
4 x .N 02 025 00…
C016 10G012 000 2
14 + PE
4 x .N 02 015 00…
11 x .N 02 016 00…
C016 10G014 000 2
19 + PE
.N 02 015 00...
C016 10G019 000 2
Part No system for crimp contacts, see page 23.
15
C 16-3
Shell size 2
Female cable connectors
E
Description
Drawing
D
F
Contacts 2)
No. of
cont.
Ø 12-14
–
5 + PE
Female cable connector, long,
style E with internal strain relief,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
Part No.
Cable outlet 3)
Ø 14-16
Ø 19-21
C016 20E005 103 2 C016 20E005 104 2 C016 20E005 105 2
12 + PE
9 x .N 02 016 00… C016 10E012 003 2 C016 10E012 004 2 C016 10E012 005 2
4 x .N 02 025 00…
14 + PE
4 x .N 02 015 00… C016 10E014 003 2 C016 10E014 004 2 C016 10E014 005 2
11 x .N 02 016 00…
19 + PE
.N 02 015 00...
C016 10E019 003 2 C016 10E019 004 2 C016 10E019 005 2
Cable outlet
Ø 10-12
Ø 12-14
5 + PE
Female cable connector, short,
style D with clamping ring,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
Female cable connector,
style F with clamping ring,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
–
C016 20D005 103 2 C016 20D005 104 2
–
12 + PE
9 x .N 02 016 00… C016 10D012 003 2 C016 10D012 004 2
4 x .N 02 025 00…
–
14 + PE
4 x .N 02 015 00… C016 10D014 003 2 C016 10D014 004 2
11 x .N 02 016 00…
–
19 + PE
.N 02 015 00...
–
C016 10D019 003 2 C016 10D019 004 2
5 + PE
–
–
C016 20F005 104 2
–
12 + PE
9 x .N 02 016 00…
4 x .N 02 025 00…
–
C016 10F012 004 2
–
14 + PE
4 x .N 02 015 00…
11 x .N 02 016 00…
–
C016 10F014 004 2
–
19 + PE
.N 02 015 00...
–
C016 10F019 004 2
–
C 16-3
Ø
Shell size 2
Male receptacle
Ø
C
Description
Drawing
No. of cont.
Male receptacle, style C,
5 + PE screw termination,
12 + PE-, 14 + PE and 19 + PEversion without contacts 1)
1)
Please order crimp contacts separately, see page 21/22.
16
2)
Contacts 2)
Panel cutout
Part No.
5 + PE
–
C016 20C005 100 2
12 + PE
9 x .N 01 016 00…
4 x .N 01 015 00...
C016 10C012 000 2
14 + PE
4 x .N 01 015 00…
11 x .N 01 016 00…
C016 10C014 000 2
19 + PE
.N 01 015 00...
C016 10C019 000 2
Part No system for crimp contacts, see page 23.
Amphenol
C 16-3
Shell size 2
Accessories
Description
Protective cap for male cable
connector and male receptacle
Part No.
Figure
for male cable connector
for male receptacle
C016 00U000 011 2
Protective cap for female cable
connector and female receptacle
for female cable connector
C016 00U000 001 2
for female receptacle
C016 00V000 011 2
Disassembly tool for pin-and socket
inserts
Amphenol
C016 00V000 001 2
FH 0002-016
17
C 16-3 EMV
Product description
The C 16-3 EMI connectors excel by versatile fields of application,
especially high mechanical requirements, industrial ebvironments and
demands for safe contact.
Main features:
• high attenuation of shielding
• contact inserts suitable for standard and EMI versions
• completely compatible with standard C 16-3, size 1
• same technical characteristics as standard C 16-3,
see page 7
• mechanical lifetime: 100 mating cycles
• we recommend the usage of the versions with two-part metal
housing in very harsh environmental conditions
Two versions available:
1.Version with metalized plastic housing accord. VDE 0610.
PE wire is connected to cable shield and housing. In case of error the
current will be lead directly to the PE wire
2.Combined version with metalized plastic and two-part metal housing
accord. VDE 0113. PE wire is securely and firmly connected with the
metal housing.
Crimp version
Order numbers do not include crimp contacts. Please order separately
(see page 21/22).
Crimp contact for higher currents are available upon request.
Crimp tooling
Ask for our catalogue “Tools”.
Testhouse
UL 1)
1)
Approval
Approval No.
E 63093
Please refer to the „Conditions of Acceptability“
18
Amphenol
C 16-3 EMV
Shell size 1
Description
Drawing
No. of
cont.
Contacts 2)
Part No.
Cable outlet
Ø max. 10.5
Male cable connector, style H,
without contacts 1), without cable
screw, metalized plastic housing
Ø max. 12.5
8 + PE .N 01 016 00... C016 10H008 012 5 C016 10H008 013 5
14 + PE 11 x
C016 10H014 012 5 C016 10H014 013 5
.N 01 015 00...
4x
.N 01 025 00...
12+3+PE 12 x
C016 10H015 012 5 C016 10H015 013 5
.N 01 015 00...
4x
.N 01 016 00...
17 + PE .N 01 015 00... C016 10H017 012 5 C016 10H017 013 5
Female cable connector, style D,
without contacts 1), without cable
screw, metalized plastic housing
8 + PE .N 02 016 00... C016 10D008 012 5 C016 10D008 013 5
14 + PE 11 x
C016 10D014 012 5 C016 10D014 013 5
.N 02 015 00...
4x
.N 02 025 00...
12+3+PE 12 x
C016 10D015 012 5C016 10D015 013 5
.N 02 015 00...
4x
.N 02 016 00...
17 + PE .N 02 015 00... C016 10D017 012 5 C016 10D017 013 5
Cable outlet
Ø 9 -11
Male cable connector, without
contacts 1), two part metal housing,
with PE contact
8 + PE .N 01 016 00...
C016 10H008 801 3
14 + PE 11 x
C016 10H014 801 3
.N 01 015 00...
4x
.N 01 025 00...
12+3+PE 12 x
C016 10H015 801 3
.N 01 015 00...
4x
.N 01 016 00...
Female cable connector, without
contacts 1), two part metal housing,
with PE contact.
17 + PE .N 01 015 00...
C016 10H017 801 3
8 + PE .N 02 016 00...
C016 10D008 801 3
14 + PE 11 x
C016 10D014 801 3
.N 02 015 00...
4x
.N 02 025 00...
12+3+PE 12 x
C016 10D015 801 3
.N 02 015 00...
4x
.N 02 016 00...
17 + PE .N 02 015 00...
1)
Please order crimp contacts separately, see page 21/22.
Amphenol
2)
C016 10D017 801 3
Part No system for crimp contacts, see page 23.
19
Description
Drawing
Female receptacle, style N,
without contacts 1)
Male receptacle, style C,
without contacts 1)
30,2 +0,2
(1.189)
SW27,2 +0,2
(1.071)
Panel cutout
No. of
cont.
Female receptacle, style G,
without contacts 1)
28,6 ±0,1
(1.126)
oder M3,5
Ø 3,8 +0,1
(.15)
Shell size 1
Ø 26,2 +0,2
(1.031)
28,6 ±0,1
(1.126)
C 16-3 EMV
Panel cutout
Contacts 2)
Part No.
8 + PE
.N 02 016 00…
C016 10G008 000 5
14 + PE
11 x.N 02 015 00...
4 x.N 02 025 00...
C016 10G014 000 5
12 + 3 + PE 12 x .N 02 015 00...
4 x .N 02 016 00...
C016 10G015 000 5
17 + PE
.N 02 015 00...
C016 10G017 000 5
8 + PE
.N 02 016 00…
C016 10N008 000 5
14 + PE
11 x.N 02 015 00...
4 x.N 02 025 00…
C016 10N014 000 5
12+3+ PE 12 x .N 02 015 00...
4 x .N 02 016 00...
C016 10N015 000 5
17 + PE
.N 02 015 00...
C016 10N017 000 5
8 + PE
.N 01 016 00…
C016 10C008 000 5
14 + PE
11 x.N 01 015 00...
4 x.N 01 025 00…
C016 10C014 000 5
12+3+PE
12 x .N 01 015 00...
4 x .N 01 016 00...
C016 10C015 000 5
.N 01 015 00...
C016 10C017 000 5
17 + PE
Assembly instructions metal housing
tightening
torque 4 - 5 Nm
ht
eflec
irmg
+1
Sch
15
+2
25
+2
65
65
+2
ntel
1
4+
. Ma
4 min
+2
25
+2
65
tightening
torque 5 - 7 Nm
1
4+
tightening
torque 4 - 5 Nm
20
1)
Please order crimp contacts separately, see page 21/22.
2)
Part No system for crimp contacts, see page 23.
Amphenol
16-3
Stamped single contacts
Stamped contacts on reel for
hand crimping tools
Crimp contacts
Pin
Series
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
Contact
Ø in mm
1,5
1,5
1,5
1,6
1,6
1,6
2,5
Stamped contacts on reel for crimp machines
100 resp. 200 pcs
Isulation
Ø in mm
0,7 - 1,6
1,3 - 2,0
1,6 - 2,1
1,0 - 2,0
1,8 - 2,8
2,5 - 3,5
1,8 - 2,8
2,5 - 3,5
No. of cont.
Shell size
Wire gauge in
mm2
AWG
Supplied as
2000 pcs.
(feeding left or
right hand side)
pcs.
Part No.
Contact plating
silver
gold
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,09 - 0,25 mm2
single contact
100
VN 01 015 0052 (1) VN 01 015 0052 (2)
28 - 24
contacts on reel
200
ZN 01 015 0052 (1) ZN 01 015 0052 (2)
right
2000
HN 01 015 0052 (1) HN 01 015 0052 (2)
left
2000
TN 01 015 0052 (1)
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,35 - 0,5 mm2
single contact
100
VN 01 015 0046 (1) VN 01 015 0046 (2)
22 - 20
contacts on reel
200
ZN 01 015 0046 (1) ZN 01 015 0046 (2)
right
2000
HN 01 015 0046 (1) HN 01 015 0046 (2)
left
2000
TN 01 015 0046 (1)
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,75 - 1,0 mm2
single contact
100
VN 01 015 0047 (1) VN 01 015 0047 (2)
18
contacts on reel
200
ZN 01 015 0047 (1)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
0,14 - 0,5 mm2
single contact
100
VN 01 016 0003 (1) VN 01 016 0003 (2)
26 - 20
contacts on reel
200
ZN 01 016 0003 (1)
TN 01 015 0052 (2)
TN 01 015 0046 (2)
ZN 01 015 0047 (2)
right
2000
HN 01 015 0047 (1) HN 01 015 0047 (2)
left
2000
TN 01 015 0047 (1)
TN 01 015 0047 (2)
ZN 01 016 0003 (2)
right
2000
HN 01 016 0003 (1) HN 01 016 0003 (2)
left
2000
TN 01 016 0003 (1)
TN 01 016 0003 (2)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
0,5 - 1,5 mm2
single contact
100
VN 01 016 0002 (1) VN 01 016 0002 (2)
20 - 16
contacts on reel
100
ZN 01 016 0002 (1)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
1,5 - 2,5 mm
14 + PE
12 + PE
14 + PE
12 + PE
1
2
1
2
2
16 - 14
ZN 01 016 0002 (2)
right
2000
HN 01 016 0002 (1) HN 01 016 0002 (2)
left
2000
TN 01 016 0002 (1)
TN 01 016 0002 (2)
single contact
100
VN 01 016 0005 (1) VN 01 016 0005 (2)
contacts on reel
200
ZN 01 016 0005 (1)
ZN 01 016 0005 (2)
right
2000
HN 01 016 0005 (1) HN 01 016 0005 (2)
left
2000
TN 01 016 0005 (1)
TN 01 016 0005 (2)
0,5 - 1,5 mm2
single contact
100
VN 01 025 0001 (101)
VN 01 025 0001 (102)
20 - 16
contacts on reel
100
ZN 01 025 0001 (1)
ZN 01 025 0001 (2)
right
2000
HN 01 025 0001 (1) HN 01 025 0001 (2)
left
2000
TN 01 025 0001 (1) TN 01 025 0001 (2)
1,5 - 2,5 mm2
single contact
100
VN 01 025 0010 (101)
VN 01 025 0010 (102)
16 - 14
contacts on reel
200
ZN 01 025 0010 (1)
ZN 01 025 0010 (2)
right
2000
HN 01 025 0010 (1) HN 01 025 0010 (2)
left
2000
TN 01 025 0010 (1) TN 01 025 0010 (2)
Single contact in plastic bag; stamped contact on reel – HN = feeding right side / TN = feeding left side
Amphenol
21
16-3
Stamped single contacts
Stamped contacts on reel
for hand crimping tools
Crimp contacts
Socket
Series
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
C 16-3
Contact
Ø in mm
1,5
1,5
1,5
1,6
1,6
1,6
2,5
Stamped contacts on reel for crimp machines
100 resp. 200 pcs
Isulation
Ø in mm
0,7 - 1,6
1,3 - 2,0
1,6 - 2,1
1,0 - 2,0
1,8 - 2,8
2,5 - 3,5
1,8 - 2,8
2,5 - 3,5
No. of cont.
Shell size
Wire gauge in
mm2
AWG
Supplied as
2000 pcs.
(feeding left or
right hand side)
pcs.
Part No.
Contact plating
silver
gold
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,09 - 0,25 mm2
single contact
100
VN 02 015 0052 (1) VN 02 015 0052 (2)
28 - 24
contacts on reel
200
ZN 02 015 0052 (1) ZN 02 015 0052 (2)
right
2000
HN 02 015 0052 (1) HN 02 015 0052 (2)
left
2000
TN 02 015 0052 (1) TN 02 015 0052 (2)
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,35 - 0,5 mm2
single contact
100
VN 02 015 0046 (1) VN 02 015 0046 (2)
22 - 20
contacts on reel
200
ZN 02 015 0046 (1) ZN 02 015 0046 (2)
right
2000
HN 02 015 0046 (1) HN 02 015 0046 (2)
left
2000
TN 02 015 0046 (1) TN 02 015 0046 (2)
14 + PE
12 + 3 + PE
17 + PE
14 + PE
19 + PE
1
1
1
2
2
0,75 - 1,0 mm2
single contact
100
VN 02 015 0047 (1) VN 02 015 0047 (2)
18
contacts on reel
200
ZN 02 015 0047 (1) ZN 02 015 0047 (2)
right
2000
HN 02 015 0047 (1) HN 02 015 0047 (2)
left
2000
TN 02 015 0047 (1) TN 02 015 0047 (2)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
0,14 - 0,5 mm2
single contact
100
VN 02 016 0003 (1) VN 02 016 0003 (2)
26 - 20
contacts on reel
200
ZN 02 016 0003 (1) ZN 02 016 0003 (2)
right
2000
HN 02 016 0003 (1) HN 02 016 0003 (2)
left
2000
TN 02 016 0003 (1) TN 02 016 0003 (2)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
0,5 - 1,5 mm2
single contact
100
VN 02 016 0002 (1) VN 02 016 0002 (2)
20 - 16
contacts on reel
100
ZN 02 016 0002 (1) ZN 02 016 0002 (2)
right
2000
HN 02 016 0002 (1) HN 02 016 0002 (2)
left
2000
TN 02 016 0002 (1) TN 02 016 0002 (2)
8 + PE
12 + 3 + PE
12 + PE
14 + PE
1
1
2
2
1,5 - 2,5 mm
single contact
100
VN 02 016 0005 (1) VN 02 016 0005 (2)
contacts on reel
200
ZN 02 016 0005 (1) ZN 02 016 0005 (2)
right
2000
HN 02 016 0005 (1) HN 02 016 0005 (2)
left
2000
TN 02 016 0005 (1) TN 02 016 0005 (2)
14 + PE
12 + PE
14 + PE
12 + PE
1
2
1
2
2
16 - 14
0,5 - 1,5 mm2
single contact
100
VN 02 025 0001 (101) VN 02 025 0001 (102)
20 - 16
contacts on reel
100
ZN 02 025 0001 (1) ZN 02 025 0001 (2)
right
2000
HN 02 025 0001 (1) HN 02 025 0001 (2)
left
2000
TN 02 025 0001 (1) TN 02 025 0001 (2)
1,5 - 2,5 mm2
single contact
100
VN 02 025 0010 (101) VN 02 025 0010 (102)
16 - 14
contacts on reel
200
ZN 02 025 0010 (1) ZN 02 025 0010 (2)
right
2000
HN 02 025 0010 (1) HN 02 025 0010 (2)
left
2000
TN 02 025 0010 (1) TN 02 025 0010 (2)
Single contact in plastic bag; stamped contact on reel – HN = feeding right side / TN = feeding left side
22
Amphenol
Part No. system for
crimp contacts
VN
__
1)
1) supplied as:
01
_
_ (1)
_ 0001
_ 016
5)
4)
2) 3)
VN = single contact 100 pcs.
ZN = contacts on reel 100 resp. 200 pcs.
HN = contacts on reel with 2000 contacts (contact feeding right hand side)
TN = contacts on reel with 2000 contacts (contact feeding left hand side)
2) Type of contact:
01 = male contact
02 = female contact
3) Contact Ø: e.g.
016 = 1,6 mm
4) Connection and wire gauge, e.g. 0052: 0,09 - 0,25 mm2
0046: 0,35 - 0,5 mm 2
0047: 0,75 - 1,0 mm 2
5) Plating:
Amphenol
(1) = silver plated
(2) = gold plated
(4) = gold plated for high performance
23
C 16-3
Technical Information
Termination methods
• Screw connection
Screw clamps are designed acc. to EN 60999-1 / VDE 609-1.
Chart 1 below shows the screw size depending
on wire size and the required clamping and testing
torque..
This comparison chart allows a cross reference between American Wire
Gauge (AWG) and metric wire sizes (mm2).
Chart 2
AWG
Wire composition
Wire diameter Wire size
30
16
1 x 0,25
7 x 0,10
1 x 0,32
7 x 0,13
1 x 0,40
7 x 0,16
19 x 0,10
1 x 0,51
7 x 0,20
19 x 0,13
1 x 0,64
7 x 0,25
19 x 0,16
1 x 0,81
7 x 0,32
19 x 0,20
1 x 1,02
19 x 0,25
19 x 0,29
0,25 mm
0,36 mm
0,32 mm
0,38 mm
0,40 mm
0,48 mm
0,51 mm
0,51 mm
0,61 mm
0,64 mm
0,64 mm
0,76 mm
0,81 mm
0,81 mm
0,97 mm
1,02 mm
1,02 mm
1,27 mm
1,44 mm
0,05 mm2
0,06 mm2
0,08 mm2
0,09 mm2
0,13 mm2
0,14 mm2
0,15 mm2
0,21 mm2
0,23 mm2
0,24 mm2
0,33 mm2
0,36 mm2
0,38 mm2
0,52 mm2
0,56 mm2
0,62 mm2
0,79 mm2
0,96 mm2
1,23 mm2
14
19 x 0,36
1,80 mm
1,95 mm2
12
19 x 0,46
2,29 mm
3,09 mm2
10
37 x 0,40
3,10 mm
4,60 mm2
8
133 x 0,29
4,0 mm
8,80 mm2
6
133 x 0,36
5,5 mm
13,5 mm2
Chart 1
Wire size (mm2)
max. 4
Screw size
M3
Test torque (Ncm)
50
Diagram 1 below shows the range of tensile strength for a screw
connection with a clamp screw M3, fastened with a torque of 50 Ncm,
depending on the wire size.
28
26
24
22
Diagram 1
Tensile strength
20
18
Wire gauge
It has to be noted that wires of the same AWG number but with different
composition have slightly different mm2.
Chart 3
Composition and Dimensions of Copper Wires
Wire Size
Wire Composition
Wire diameter
2
12 x 0,10
0,48 mm
0,14 mm2
18 x 0,10
0,50 mm
0,25 mm
2
14 x 0,15
0,70 mm
0,34 mm
2
0,09 mm
0,5 mm2
0,78 mm
1,0 mm
0,75 mm2
24 x 0,20
1,2 mm
1,0 mm2
32 x 0,20
1,4 mm
1,5 mm2
30 x 0,25
1,6 mm
2,5 mm2
35 x 0,30
2,2 mm
2
56 x 0,30
2,8 mm
6,0 mm2
19 x 0,64
3,4 mm
19 x 0,80
4,3 mm
4,0 mm
10 mm
24
7 x 0,25
16 x 0,20
2
Amphenol
C 16-3
Technical Information
• Crimp connection
A crimp connection is a non-detachable electrical connection between a
wire and a crimp contact produced with the crimp technology.
Precise crimping dies which are matched to the crimp barrel and the
wire size and a defined deformation result in a reliable electrical
connection.
There are open crimp barrels (stamped contacts) and closed crimp
barrels (turned contacts).
The main advantages of crimp connections are:
• Efficient termination of contacts.
• Reproducible termination achieve consistent electrical
and mechanical results
An important point of the quality of a crimp connection is the achieved
tensile strength of the termination.
Easily measured, the tensile strength is a practible means for quality
control purposes.
Diagram 2 below shows the required minimum tensile strength for open
and closed barrels depending on the wire size.
Assembly instructions
For crimp contacts use the released crimp tool.
The insertion and extraction of crimp contacts shall only be approved with
the corresponding insertion / extraction tool.
A detailed description of the crimp technology can be found in
our crimp tooling catalogues.
The requirements for crimp connections are defined
in DIN EN 60352-2, IEC 60352-2.
Crimp contacts are in this catalogues on page 21 and 22.
Diagram 2
N
lb
1000
4000
3000
500
400
2000
300
1000
Min. tensile strength N / lb
200
500
400
100
300
50
40
200
30
100
20
50
40
10
30
5
mm2 0,05
AWG
0,1
0,2
28
26
24
22
0,5
20
1,0 1,5
2,5
4,0 6,0
12
10
14
18 16
10,0
8
20
Wire gauge in mm2 / AWG
Amphenol
25
C 16-3
Technical Information
Chart 5
Degree of protection
Electrical devices to which connectors belong to have to be protected for
safety reasons from outside influences like dust, foreign objects, direct
contact, moisture and water. This protection is provided on industrial
connectors by its housings with their latching devices and sealed cable
entries. The degree of protection can be selected depending on the type of
intended use. The standard IEC 60529 and/or DIN EN 60529 has specified
the degree of protection and divided into several classes.
The degree of protection is indicated in the following way:
IP 65
Code letters
(Internat. Protection)
1st charact. numeral (degree of protection against access
to hazardous parts and against solid foreign objects)
2nd charact. numeral (degree of protection against ingress of water)
2nd charact. Brief description
numeral
Definition
0
1
Non-protected
Protected against vertically
falling water drops
–
Vertically falling drops shall
have no harmful effects.
2
Protected against vertically
falling water drops when
enclosure tilted up to 15°
Vertically falling drops shall
have no harmful effects when
the enclosure is tilted at any
angel up to 15° on either side
of the vertical.
3
Protected against spraying
water
Water sprayed at an angle up
to 60° on either side of the
vertical shall have no harmful
effects.
4
Protected against splashing
water
Water splashed against the
enclosure from any direction
shall have no harmful effects.
5
Protected against water jets
Water projected in jets against
the enclosure from any
direction shall have no harmful
effects.
6
Protected against powerful
water jets
Water projected in powerful
jets against the enclosure
from any direction shall have
no harmful effects.
7
Protected against the effects
of temporary immersion in
water
Intrusion of water in quantities
causing harmful effects
shall not be possible when
the enclosure is temporalily
immersed in water for 30 min.
in 1m depth.
8
Protected against the effects
of continous immersion in
water
Intrusion of water in quantities
causing harmful effects shall
not be possible when the
enclosure is continuously
immersed in water under
conditions which shall be
agreed between manufacturer
and user but which are more
severe than for numeral 7.
9 K 1)
Protected against water
during high pressure/steam
jet cleaning
Water projected in powerful
jets with high pressure against
the enclosure from any
direction shall have no harmful
effects.
The following charts 4 and 5 give an overview about all protection degrees.
Chart 4
1st charact. Brief description
numeral
Definition
0
1
Non-protected
Protected against access
to hazardous parts with the
back of a hand. Protected
against solid foreign
objects of ≥50mm Ø.
–
The probe, sphere of 50mm
Ø, shall not fully penetrate
and shall have adequate
clearance from hazardous
parts.
Protected against access
to hazardous parts with a
finger.
Protected against solid
foreign objects of
≥12,5mm Ø.
The jointed test finger of
12mm Ø, 80mm length,
shall have adequate clearance
from hazardous parts. The
probe, sphere of 12,5mm Ø,
shall not fully penetrate.
2
3
4
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire. not penetrate at all.
Protected against solid
foreign objects of ≥1mm Ø.
5
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire. not penetrate.
Dust-protected.
Intrusion of dust is not
totally prevented, but dust
shall not penetrate in a
quantity to interfere with
satisfactory operation of the
device or to impair safety.
6
26
Protected against access to The probe of 2,5mm Ø shall
hazardous parts with a tool. not penetrate at all.
Protected against solid foreign
objects of ≥2,5mm Ø.
Protected against access to The probe of 1mm Ø shall
hazardous parts with a wire not penetrate.
Dust-tight.
No intrussion of dust.
1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code
Amphenol
C16-3
Remarks
Safety classification
1. General Remarks
These connectors are designed and produced in conformity with the
low voltage directive (73/23/EWG) respectively Gerätesicherheitsgesetz
(German law) and are especially in according with the standards
DIN EN 61984 / IEC 61984 (VDE 0627); IEC 60664-1 (VSE 0110-1) and
IEC 60529. The connectors may be used only within the technical ratings.
These connectors with / without breaking capacity are designed and
produced according to DIN EN 61984/VDE0627.
All technical data refers to mated connectors under live conditions.
The safety of the connector system depends on the correct selection of
products, proper assembly of the connector device, and a precise fit of the
connectors.
2. Application Remarks
Connectors with / without breaking capacity must be used according to
specified technical ratings.
The technical data represents the initial value of mated parts under
predetermined conditions and length of time.These values could change
with different test parameters or product requirements.
The 16-3 Series connectors are used in a wide variety of industries and
equipment. Some of these include industrial machines and controls,
data processing, instrumentation and test equipment, medical devices,
telecommunication’s network and equipment, plus outdoor and marine
applications.
All rated data for the connectors listed in this catalogues are based
on over-voltage category III 1) and pollution degree 3 2) for electronic
applications.
Connectors were completely mated according to their respective safety
locking mechanism. Selection and testing of connectors with / without
breaking capacity to meet specific product or industrial requirements such
as rated voltage and the related clearances and creepage distances are the
responsibility of the user.
3. Assembling Remarks
Protection against electrical shock of the termination of the connectors
shall be secured by correct mounting. Connectors of the same or different
series being mounted side by side may be protected against incorrect
mating by the use of coding options. Care must be taken to ensure the
parts are correctly mated and screws are tightened with the proper torque.
4. Termination Remarks
Cable connectors are effectively secured when using the internal cable
clamp. When the connector contains a simple gland bushing for retention
without clamping ring the cable should have a strain relief close behind
the connector. All cable properties or specifications must be compatible
with the connector design and materials.
Designated wire conductors must be terminated to the correct poles in the
connector.
Crimp contacts must be fully inserted into the plastic housing and
retention assured with a slight tug on the wire.
Wire should be stripped correctly according to printed specifications to
insure no electrical contact can be made between the conductors. There
should be no nicked or cut strains during the stripping action.
2)
3)
X
X
Female cable connector
X
X
X
Male receptacle
screw / crimp
X 3)
X
X 3)
Female receptacle
screw / crimp
X 3)
X
X 3)
X
X
X 3)
Cable clamp
rewirable
X
connector with
breaking
capacity
finger safety
mated
enclosed
mated
1)
Male cable connector
hand back
safety mated
protective
earthing contact
X
Style
finger safety
unmated
enclosed
unmated
5. Safety Classification acc. to DIN EN 61984 / VDE 0627 / IEC 61984
with
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
without
Overvoltage category III: Equipment intended for the use in installations or parts of it in which lightning overvoltages do not need to be considered,
however switching overvoltages generated by the equipment, and for cases where the reliability and the availability of the equipment or its dependent
circuits are subject to special requirements. Examples are protecting means, switches and sockets.
Pollution degree 3: Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to be expected.
Protection against electrical shock on the termination side has to be secured by proper mounting.
Amphenol
27
Summary of
Part Numbers
Part No.
28
Page
Part No.
Page
Part No.
Page
Part No.
Page
C016 00U000 001 1
14
C016 10D015 801 3
19
C016 10G008 000 5
20
C016 10I008 002 1
12
C016 00U000 001 2
17
C016 10D017 002 1
13
C016 10G012 000 2
15
C016 10I008 003 1
12
C016 00U000 011 2
17
C016 10D017 003 1
13
C016 10G014 000 1
13
C016 10I012 003 2
15
C016 00U000 021 1
14
C016 10D017 012 5
19
C016 10G014 000 2
15
C016 10I012 004 2
15
C016 00V000 001 1
14
C016 10D017 013 5
19
C016 10G014 000 5
20
C016 10I012 005 2
15
C016 00V000 001 2
17
C016 10D017 801 3
19
C016 10G015 000 1
13
C016 10I014 002 1
12
C016 00V000 011 2
17
C016 10D019 003 2
16
C016 10G015 000 5
20
C016 10I014 003 1
12
C016 00V000 021 1
14
C016 10D019 004 2
16
C016 10G017 000 1
13
C016 10I014 003 2
15
C016 10C008 000 1
14
C016 10E008 002 1
13
C016 10G017 000 5
20
C016 10I014 004 2
15
C016 10C008 000 5
20
C016 10E008 003 1
13
C016 10G019 000 2
15
C016 10I014 005 2
15
C016 10C012 000 2
16
C016 10E012 003 2
16
C016 10H008 002 1
12
C016 10I015 002 1
12
C016 10C014 000 1
14
C016 10E012 004 2
16
C016 10H008 003 1
12
C016 10I015 003 1
12
C016 10C014 000 2
16
C016 10E012 005 2
16
C016 10H008 012 5
19
C016 10I017 002 1
12
C016 10C014 000 5
20
C016 10E014 002 1
13
C016 10H008 013 5
19
C016 10I017 003 1
12
C016 10C015 000 1
14
C016 10E014 003 1
13
C016 10H008 801 3
19
C016 10I019 003 2
15
C016 10C015 000 5
20
C016 10E014 003 2
16
C016 10H012 003 2
15
C016 10I019 004 2
15
C016 10C017 000 1
14
C016 10E014 004 2
16
C016 10H012 004 2
15
C016 10I019 005 2
15
C016 10C017 000 5
20
C016 10E014 005 2
16
C016 10H014 002 1
12
C016 10K008 002 1
12
C016 10C019 000 2
16
C016 10E015 002 1
13
C016 10H014 003 1
12
C016 10K008 003 1
12
C016 10D008 002 1
13
C016 10E015 003 1
13
C016 10H014 003 2
15
C016 10K012 004 2
15
C016 10D008 003 1
13
C016 10E017 002 1
13
C016 10H014 004 2
15
C016 10K014 002 1
12
C016 10D008 012 5
19
C016 10E017 003 1
13
C016 10H014 005 2
15
C016 10K014 003 1
12
C016 10D008 013 5
19
C016 10E019 003 2
16
C016 10H014 012 5
19
C016 10K014 004 2
15
C016 10D008 801 3
19
C016 10E019 004 2
16
C016 10H014 013 5
19
C016 10K015 002 1
12
C016 10D012 003 2
16
C016 10E019 005 2
16
C016 10H014 801 3
19
C016 10K015 003 1
12
C016 10D012 004 2
16
C016 10F008 002 1
13
C016 10H015 002 1
12
C016 10K017 002 1
12
C016 10D014 002 1
13
C016 10F008 003 1
13
C016 10H015 003 1
12
C016 10K017 003 1
12
C016 10D014 003 1
13
C016 10F012 004 2
16
C016 10H015 012 5
19
C016 10K019 004 2
15
C016 10D014 003 2
16
C016 10F014 002 1
13
C016 10H015 013 5
19
C016 10N008 000 5
20
C016 10D014 004 2
16
C016 10F014 003 1
13
C016 10H015 801 3
19
C016 10N008 006 1
13
C016 10D014 012 5
19
C016 10F014 004 2
16
C016 10H017 002 1
12
C016 10N014 000 5
20
C016 10D014 013 5
19
C016 10F015 002 1
13
C016 10H017 003 1
12
C016 10N014 006 1
13
C016 10D014 801 3
19
C016 10F015 003 1
13
C016 10H017 012 5
19
C016 10N015 000 5
20
C016 10D015 002 1
13
C016 10F017 002 1
13
C016 10H017 013 5
19
C016 10N015 006 1
13
C016 10D015 003 1
13
C016 10F017 003 1
13
C016 10H017 801 3
19
C016 10N017 000 5
20
C016 10D015 012 5
19
C016 10F019 004 2
16
C016 10H019 003 2
15
C016 10N017 006 1
13
C016 10D015 013 5
19
C016 10G008 000 1
13
C016 10H019 004 2
15
C016 20C005 100 2
16
Amphenol
Summary of
Part Numbers
Part No.
Page
Part No.
Page
Part No.
Page
Part No.
Page
C016 20D005 103 2
16
HN 02 016 0002 (1)
22
TN 02 016 0005 (2)
22
ZN 01 015 0046 (1)
21
C016 20D005 104 2
16
HN 02 016 0002 (2)
22
TN 02 025 0001 (1)
22
ZN 01 015 0046 (2)
21
C016 20E005 103 2
16
HN 02 016 0003 (1)
22
TN 02 025 0001 (2)
22
ZN 01 015 0047 (1)
21
C016 20E005 104 2
16
HN 02 016 0003 (2)
22
TN 02 025 0010 (1)
22
ZN 01 015 0047 (2)
21
C016 20E005 105 2
16
HN 02 016 0005 (1)
22
TN 02 025 0010 (2)
22
ZN 01 015 0052 (1)
21
C016 20F005 104 2
16
HN 02 016 0005 (2)
22
VN 01 015 0046 (1)
21
ZN 01 015 0052 (2)
21
C016 20G005 100 2
15
HN 02 025 0001 (1)
22
VN 01 015 0046 (2)
21
ZN 01 016 0002 (1)
21
C016 20H005 103 2
15
HN 02 025 0001 (2)
22
VN 01 015 0047 (1)
21
ZN 01 016 0002 (2)
21
C016 20H005 104 2
15
HN 02 025 0010 (1)
22
VN 01 015 0047 (2)
21
ZN 01 016 0003 (1)
21
C016 20I005 103 2
15
HN 02 025 0010 (2)
22
VN 01 015 0052 (1)
21
ZN 01 016 0003 (2)
21
C016 20I005 104 2
15
TN 01 015 0046 (1)
21
VN 01 015 0052 (2)
21
ZN 01 016 0005 (1)
21
C016 20I005 105 2
15
TN 01 015 0046 (2)
21
VN 01 016 0002 (1)
21
ZN 01 016 0005 (2)
21
C016 20K005 104 2
15
TN 01 015 0047 (1)
21
VN 01 016 0002 (2)
21
ZN 01 025 0001 (1)
21
FH 0000-016
14
TN 01 015 0047 (2)
21
VN 01 016 0003 (1)
21
ZN 01 025 0001 (2)
21
FH 0002-016
17
TN 01 015 0052 (1)
21
VN 01 016 0003 (2)
21
ZN 01 025 0010 (1)
21
HN 01 015 0046 (1)
21
TN 01 015 0052 (2)
21
VN 01 016 0005 (1)
21
ZN 01 025 0010 (2)
21
HN 01 015 0046 (2)
21
TN 01 016 0002 (1)
21
VN 01 016 0005 (2)
21
ZN 02 015 0046 (1)
22
HN 01 015 0047 (1)
21
TN 01 016 0002 (2)
21
VN 01 025 0001 (101)
21
ZN 02 015 0046 (2)
22
HN 01 015 0047 (2)
21
TN 01 016 0003 (1)
21
VN 01 025 0001 (102)
21
ZN 02 015 0047 (1)
22
HN 01 015 0052 (1)
21
TN 01 016 0003 (2)
21
VN 01 025 0010 (101)
21
ZN 02 015 0047 (2)
22
HN 01 015 0052 (2)
21
TN 01 016 0005 (1)
21
VN 01 025 0010 (102)
21
ZN 02 015 0052 (1)
22
HN 01 016 0002 (1)
21
TN 01 016 0005 (2)
21
VN 02 015 0046 (1)
22
ZN 02 015 0052 (2)
22
HN 01 016 0002 (2)
21
TN 01 025 0001 (1)
21
VN 02 015 0046 (2)
22
ZN 02 016 0002 (1)
22
HN 01 016 0003 (1)
21
TN 01 025 0001 (2)
21
VN 02 015 0047 (1)
22
ZN 02 016 0002 (2)
22
HN 01 016 0003 (2)
21
TN 01 025 0010 (1)
21
VN 02 015 0047 (2)
22
ZN 02 016 0003 (1)
22
HN 01 016 0005 (1)
21
TN 01 025 0010 (2)
21
VN 02 015 0052 (1)
22
ZN 02 016 0003 (2)
22
HN 01 016 0005 (2)
21
TN 02 015 0046 (1)
22
VN 02 015 0052 (2)
22
ZN 02 016 0005 (1)
22
HN 01 025 0001 (1)
21
TN 02 015 0046 (2)
22
VN 02 016 0002 (1)
22
ZN 02 016 0005 (2)
22
HN 01 025 0001 (2)
21
TN 02 015 0047 (1)
22
VN 02 016 0002 (2)
22
ZN 02 025 0001 (1)
22
HN 01 025 0010 (1)
21
TN 02 015 0047 (2)
22
VN 02 016 0003 (1)
22
ZN 02 025 0001 (2)
22
HN 01 025 0010 (2)
21
TN 02 015 0052 (1)
22
VN 02 016 0003 (2)
22
ZN 02 025 0010 (1)
22
HN 02 015 0046 (1)
22
TN 02 015 0052 (2)
22
VN 02 016 0005 (1)
22
ZN 02 025 0010 (2)
22
HN 02 015 0046 (2)
22
TN 02 016 0002 (1)
22
VN 02 016 0005 (2)
22
HN 02 015 0047 (1)
22
TN 02 016 0002 (2)
22
VN 02 025 0001 (101)
22
HN 02 015 0047 (2)
22
TN 02 016 0003 (1)
22
VN 02 025 0001 (102)
22
HN 02 015 0052 (1)
22
TN 02 016 0003 (2)
22
VN 02 025 0010 (101)
22
HN 02 015 0052 (2)
22
TN 02 016 0005 (1)
22
VN 02 025 0010 (102)
22
Amphenol
29
30
Amphenol
Amphenol
31
International
Argentina
Amphenol Argentina
Av. Callao 930
2nd Floor Office B “Plaza“
C1023 AAP Buenos Aires
Phone +54 / 11 / 4815 68 86
Fax +54 / 11 / 4814 57 79
Hong Kong
Amphenol East Asia Limited
Units 2201-02, Railway Plaza
39 Chatham Road South
Tsimshatsui, Kowloon
Phone +852 / 2699 / 2663
Fax +8 52 / 26 88 / 09 74
Australia
Amphenol Australia Ltd.
2 Fiveways Blvd
Keysborough
Victoria 31 73
Phone +61 / 3 / 8796 / 8888
Fax +61 / 3 / 8796 / 8801
India
Amphetronix Limited
Plot No. 105 Bhosari Industrial Area
Pune - 411 026
Phone +91 / 20 / 27121418
Fax +91 / 20 / 27120581
Belgium
Amphenol-Tuchel Belgium
Brusselbaan 524b
B 1600 Sint-Pieters-Leeuw
Phone +32 / 2377 / 2549
Fax +32 / 2377 / 5303
Brasilia
Amphenol do Brasil Ltda.
Rua Diogo Moreira 132, 20th Floor
CEP 05423-010 Sao Paulo SP
Phone +55 / 11 / 3815.1003
Fax +55 / 11 / 3815.1629
China
Amphenol-Tuchel Electronics GmbH
China Branch
210-1 Taishan Road
Changzhou 213022
Phone +86 / 0519 / 5110301
Fax +86 / 0519 / 5110299
ATE 2020 B 0406 3.000
Printed on chlorin-free bleached paper, specifications may be changed without notice.
Copyright 04/06 by Amphenol-Tuchel Electronics GmbH, Germany
France
Amphenol-Tuchel France
Bât. Le Newton C
7 Mail B. Thimonnier
77185 Lognes
Phone +33 / 164627676
Fax +33 / 164627677
Germany
Amphenol-Tuchel Electronics GmbH
August-Haeusser-Str. 10
74080 Heilbronn
Phone +49 / 7131 / 929-0
Fax +49 / 7131 / 929-486
Great Britain
Amphenol-Tuchel Great Britain
14 Plover Close
Kempshott, Basingstoke
Hants, RG22 5PQ
Phone +44 / 1256 / 330749
Fax +44 / 1256 / 330749
Italy
Amphenol-Tuchel Italy
Via Barbaiana n. 5
l-20020 Lainate (MI)
Phone +39 / 2 / 932 541
Fax +39 / 2 / 932 54444
Japan
Amphenol Japan, K.K.
2-3-27, Kudan Minami
Chiyoda-Ku
Tokyo 102
Phone +81 / 3 / 3263 / 5611
Fax +81 / 3 / 5276 / 7059
Korea
Amphenol DaeShin Limited
#802 Joong-Dong 1131-5
Wonmi-Ku
Bucheon-City
Kyunggi-Do
Korea 420-020
Phone +82 / 2 / 785 / 1588
Fax +82 / 2 / 589 / 1514
Mexico
Amphenol Mexico
Prolongacion Reforma 61 - 6 B2
Col. Paseo de las Lomas
C.P. 01330 Mexico D.F.
Phone +52 / 55 / 5258.9984
Fax +52 / 55 / 5081.6890
Spain
Amphenol-Tuchel Spain
Ctra Sabadell a Mollet,
km 4.5 Nave 5
08130 Santa Perpetua de
Mogoda (Barcelona)
Phone +34 / 93 / 574.41.34
Fax +34 / 93 / 574.10.09
Sweden
Amphenol-Tuchel Scandinavia
P.O. Box 20
SE 195 42 Märsta
Phone +46 / 8 591 / 175 76
Fax +46 / 8 591 / 175 76
Taiwan
Amphenol East Asia Ltd.
Taiwan Branch (H.K.)
116 Zhong Shan Road
Lane 956 Taoyuan City
Taiwan R.O.C. 330
Phone +886 / 3 / 370 / 7855
Fax +886 / 3 / 360 / 7259
Turkey
Amphenol Turkiye
Ayazaga Mah. Meydan Sk. No. 28
Beybi Giz Plaza, Kat. 26
34396 Maslak/Istanbul
Phone +90 / 0212 / 3352501
Fax +90 / 0212 / 3352500
USA
Amphenol-Tuchel Electronics
6900 Haggerty Road
Suite 200
Canton, Michigan 48187
Phone +1 / 734 / 4516400
Fax +1 / 734 / 451 7197
Amphenol Corporation
Corporate Headquarters
358 Hall Avenue
Wallingford, CT 06492
Phone +1 / 800 / 380 8052
Phone +1 / 2 03 / 2 65 / 89 00
Fax +1 / 2 03 / 2 65 / 86 28
Singapore
Amphenol East Asia Limited
Asia Pacific Sales Operation
Singapore Branch
300 Beach Road
#25-07 The Concourse
Singapore 199555
Phone +27 / 11 / 305-9574
Fax +27 / 11 / 305-9576
South Africa
Amphenol International Ltd
Chislehurston
30 Impala Road
Chislehurston
Sandton, 2146
Phone +27 / 11 / 7839517
Fax +27 / 11 / 7839519
Your engineering sales representative:
Amphenol
Amphenol-Tuchel Electronics GmbH
32
Amphenol
August-Haeusser- Str. 10 . D-74080 Heilbronn . Germany . Phone +49 (0) 71 31/ 9 29-0 . Fax +49 (0) 71 31/ 9 29-486 · www.amphenol.info
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Amphenol:
VN02 016 0003 1 VN02 016 0002 1 VN01-015-0047-2 VN01 016 0015 1 VN01-016-0011-2 VN02-016-0002-2
VN02-016-0003-2 VN01 016 0011 1 VN01 016 0004 1 VN01 025 0010 101 VN02 025 0001 101 C016-10H012-003-2
VN01-016-0005-2 VN02-016-0005-2 ZN0101500521 TN0202500011 ZN0201500522 VN0201500472
TN0101500471 ZN0101500472 HN0201600052 HN0101500521 ZN0201500462 ZN0101500471 HN0201600022
HN0101600021 TN0102500101 TN0201500522 HN0201600051 VN0101500522 TN0101600051 HN0101600052
TN0201500521 HN0201500471 HN0101500522 HN0201500472 TN0101500522 HN0201600031 TN0101600031
HN0201500461 HN0101600022 VN0201500521 HN0101600051 HN0201500522 TN0102500011 TN0201600051
TN0201500461 HN0101600032 VN0101500521 ZN0101500522 TN0201500462 ZN0201500471 TN0101500472
TN0101500462 TN0101500521 HN0201600032 TN0201600032 ZN0201500472 VN0201500522 ZN0201500521
TN0201600022 TN0201500472 TN0101500461 HN0101600031 HN0201500521 TN0202500101 TN0201600021
TN0201600031 TN01 015 0052 2 TN02 015 0046 2 TN01 015 0047 2 ZN02 015 0046 2 TN01 015 0047 1 TN02 015
0047 2 ZN01 015 0047 2 VN01 015 0052 2 TN02 015 0052 2 VN01 015 0047 2 HN02 015 0052 2 ZN02 015 0047 2
TN02 015 0052 1 TN01 015 0046 2 HN02 015 0052 1 ZN02 015 0047 1 ZN01 015 0052 1 VN02 015 0047 2 VN01
015 0052 1 HN02 015 0047 1 HN01 015 0052 2 ZN02 015 0052 2 HN01 015 0052 1 ZN02 015 0052 1 HN02 015
0047 2 TN01 015 0046 1 ZN01 015 0047 1 TN02 015 0046 1 HN02 015 0046 1 ZN01 015 0052 2 TN01 015 0052 1
VN01 016 0011 2