JP510S

JP510S

  • 厂商:

    ANAREN(安伦)

  • 封装:

    SMD4

  • 描述:

    COUPLERDIRECT2.0-2.3GHZ10DB

  • 数据手册
  • 价格&库存
JP510S 数据手册
Model JP510S Rev D Pico Xinger 10dB Directional Coupler Description The JP510S Pico Xinger is a low profile, miniature 10dB directional coupler in an easy to use surface mount package designed for UMTS and WCDMA applications. The JP510S is for power and frequency detection as well as power injection. The JP510S is an ideal solution for the ever-increasing demands of the wireless industry for smaller printed circuit boards and high performance. Parts have been subjected to rigorous qualification testing and units are 100% tested. They are manufactured using materials with x and y thermal expansion coefficients compatible with common substrates. ELECTRICAL SPECIFICATIONS** Features: • • • • • • • • • 2000-2300 MHz UMTS and WCDMA Very Low Loss High Directivity Surface Mountable Tape and Reel New Pico-Package Lead Free 100% Tested Frequ ency Mean Coupling Insertion Loss VSWR dB Max Max : 1 20002300 10 ± 0.75 0.25 1.22 Power Handling Directivity Avg. CW Watts @ 85 ºC dB Min ns ºC 20 20 0.15 ± 0.04 -55 to +150 MHz dB Freq. Sensitivity dB Max ± 0.2 Operating Temp. Group Delay **Specification based on performance of unit properly installed on microstrip printed circuit boards with 50 Ω nominal impedance. Specifications subject to change without notice. Top View (Near-side) Pin 1 .250±.010 [6.35±0.25] Side View Bottom View (Far-side) .049±.005 [1.23±0.13] Pin 2 Pin 2 4X .020±.004 [0.51±0.10] Pin 1 GND Orientation Marker Denotes Pin Location .200±.010 [5.08±0.25] .120±.004 [3.05±0.10] 4X .034±.004 SQ [0.86±0.10] GND Pin 4 Denotes Array number Dimensions are in Inches [Millimeters] JP510S Mechanical Outline Pin 3 Pin 3 .170±.004 [4.32±0.10] Pin 4 Tolerances are Non-Cumulative Available on Tape and Reel For Pick and Place Manufacturing. USA/Canada: Toll Free: Europe: Asia: (315) 233-5510 (833) 389-6402 +44 2392-232392 +86 512 62749282 Model JP510S Rev D Typical Performance: 2 GHz – 2.3 GHz COUPLING Choice of a coupling value in an application normally depends on the power level of the main (sampled) line. For example, if the coupler is being used to monitor main line power, the coupling value is selected to provide sufficient power to the monitoring device and yet minimize system loss. Note that any coupler reduces power flowing in the main line by the amount coupled off; a 10dB coupler reduces main line power by 1 dB (10%) where a 20dB coupler reduces it by only 0.044dB (1%). Anaren uses mean coupling and frequency sensitivity with the coupling specification. The mean coupling value is arrived at by periodically sampling the coupling value over the specified band and averaging the readings. Frequency sensitivity is the peak to peak variation in coupling over the specified band. USA/Canada: Toll Free: Europe: Asia: (315) 233-5510 Available on Tape and (833) 389-6402 Reel For Pick and Place +44 2392-232392 Manufacturing. +86 512 62749282 VSWR & DIRECTIVITY In directional couplers, directivity is specified in lieu of isolation. Directivity is a measure of how well the coupled power is isolated from reflections at the main line output port. For example, open or short circuiting the output port of a coupler with 20dB directivity would only affect the coupled output power by 1% and only 0.1% for 30dB directivity. High directivity is especially important if the coupler is being used to measure the VSWR of a device at its output port. In this application, accurate measurements of forward and reverse power are required. In theory, VSWR and directivity characteristics of a coupler are perfect; the input and output ports are perfectly matched and no power is coupled to the isolated port. In practice, factors associated with the design and manufacturing processes limit VSWR and directivity. The Model JP510S Rev D JP510S Power Derating Curve Power Derating: The power handling and corresponding power derating plots are a function of the thermal resistance, mounting surface temperature (base plate temperature), maximum continuous operating temperature of the coupler, and the thermal insertion loss. The thermal insertion loss is defined in the Power Handling section of the data sheet. As the mounting interface temperature approaches the maximum continuous operating temperature, the power handling decreases to zero. Available on Tape and Reel For Pick and Place Manufacturing. USA/Canada: Toll Free: Europe: Asia: (315) 233-5510 (833) 389-6402 +44 2392-232392 +86 512 62749282 Model JP510S Rev D VSWR & DIRECTIVITY (CONTINUED) internal meandering of the coupled lines and limitations of building perfect 50Ω transitions at the input and output ports of the device are the most significant factors against perfect VSWR and directivity. Typically, VSWR and directivity of 1.15:1 and 25 dB respectively are achieved in practice. INSERTION LOSS Coupler insertion loss is defined as the log of the input power divided by the sum of the power at the two output ports. In practice, typical loss is approximately 0.20 dB. Specification limits are somewhat higher due to imperfect test conditions; surface mount couplers must be tested in test fixtures that negatively affect results. PIN CONFIGURATION The JP510S’s have an orientation marker to denote either pin 1 or pin 2. When the input port is identified, the output, coupled and isolated ports are known automatically. For example, if the input port for a device was selected to be Pin 1, Pin 2 automatically becomes the output port, Pin 4 becomes the coupled port, and Pin 3 is the isolated port. Similarly, if Pin 2 was to be selected as the input port, the adjacent port on the long side (Pin 1) is the output port, the adjacent port on the short side (Pin 3) is the coupled port, and the opposite port (Pin 4) is the isolated port. Either port on the same side as the orientation marker can be selected as the input port, as shown in the table, which shows both pin configurations. The use of pin 1 or pin 2 as the input port ensures phase consistency as well as maximum power handling. MOUNTING For Xinger surface mount couplers to operate optimally, there must be 50Ω transmission lines leading to and from all of the RF ports. To ensure proper electrical and thermal performance, there must be a ground plane with 100% solder connection underneath the part. If either of these two conditions is not satisfied, insertion loss, coupling, VSWR and directivity may not meet published specifications. SUGGESTED FOOTPRINT To ensure proper electrical and thermal performance there must be a ground plane with 100% solder connection underneath the part Multiple plated thru holes to ground .170 [4.32] .120 [3.05] 4X .034 [0.86] 4X .063 SQ [1.60] Dimensions are in Inches [Millimeters] JP510S Mounting Footprint USA/Canada: Toll Free: Europe: Asia: (315) 233-5510 Available on Tape and (833) 389-6402 Reel For Pick and Place +44 2392-232392 Manufacturing. +86 512 62749282 4X 50  Transmission Line Model JP510S Rev D PACKAGING Packaging follows EIA-481-2. Parts are oriented in tape as shown below. Xinger® Tape & Reel Diagram Available on Tape and Reel For Pick and Place Manufacturing. USA/Canada: Toll Free: Europe: Asia: (315) 233-5510 (833) 389-6402 +44 2392-232392 +86 512 62749282
JP510S 价格&库存

很抱歉,暂时无法提供与“JP510S”相匹配的价格&库存,您可以联系我们找货

免费人工找货