X3DC08E2S
Rev H
Doherty Combiner
Description:
The X3DC08E2S is a low profile, high performance Doherty
Combiner in a new easy to use, manufacturing friendly surface mount
package. The X3DC08E2S is designed particularly for Doherty
Amplifier applications, where tightly controlled phase and amplitude
imbalance as well as low insertion loss are required for maximum and
low power condition. It can be used in high power applications up to
200 watts.
Parts have been subjected to rigorous qualification testing and they
are manufactured using materials with coefficients of thermal
expansion (CTE) compatible with common substrates such as FR4,
G-10, RF-35, RO4350 and polyimide. Produced with 6 of 6 RoHS
compliant tin immersion finish.
Features:
• 862 - 894 MHz
• High Power
• Low Amp Imbalance
• Very Low Loss
• Production Friendly
• Tape and Reel
• Lead Free
Mechanical Outline:
Electrical Specifications:
Frequency
Return
Loss [1]
Insertion
Loss [1]
Amplitude
Imbalance [1]
Phase
Imbalance[1]
MHz
dB Min
dB Max
dB Max
Degrees
862 – 894
20
0.15
±0.12
90 ± 3.0
Return Loss
Insertion
Loss [2]
Port
Extension[3]
Power
Operating
Temp.
dB Min
dB Max
Degrees
Avg. CW Watts
ºC
20
0.25
0
200
-55 to +150
[2]
**Specification based on performance of unit properly installed on a TTM test board
[1] At maximum power condition, Doherty combiner functions as an equal-split power combiner.
[2] At low power condition, Doherty combiner functions as a 100Ω to 50Ω impedance transformer.
[3] There are short 50 ohm lines associated with input ports of 0° at 881MHz. Details in page 2
1
X3DC08E2S
Rev H
Doherty Amplifier Configuration
Doherty Combiner Pin Configuration
The X3DC08E2S has an orientation marker to denote Pin 1. Once port one has been identified the other
ports are known automatically. Please see the chart below for clarification:
Pin 1
Combining Port
Pin 2
Not Used
Pin 3
Peak Amp Port
Pin 4
Main Amp Port
There are inevitably short lines associating with input ports in some high frequency band parts. The length of
the short line is specified as electrical length at center frequency and noted as port extension in this
datasheet. The designer should take this length into the consideration to optimize the offset line length.
2
X3DC08E2S
Rev H
Insertion Loss and Power Derating Curves
Insertion Loss Derating
Power Derting
The insertion loss, at a given frequency, of a group of
Xinger parts is measured at 25°C and then averaged.
The measurements are performed under small signal
conditions (i.e. using a Vector Network Analyzer). The
process is repeated at 85°C and 150°C. A best-fit line for
the measured data is computed and then plotted from 55°C to 150°C.
The power handling and corresponding power derating
plots are a function of the thermal resistance, mounting
surface temperature (base plate temperature),
maximum continuous operating temperature of the
coupler, and the thermal insertion loss. The thermal
insertion loss is defined in the Power Handling section
of the data sheet.
As the mounting interface temperature approaches the
maximum continuous operating temperature, the
power handling decreases to zero.
If mounting temperature is greater than 95°C, Xinger
part will perform reliably as long as the input power is
derated to the curve above.
3
X3DC08E2S
Rev H
Typical Performance (-55°C, 25°C, 95°C ): 862-894 MHz
4
X3DC08E2S
Rev H
5
X3DC08E2S
Rev H
Definition of the Specifications
To guarantee the part performance in Doherty architecture, the part is specified in Doherty operation for
maximum power condition and low power condition. The following specification definition assumes the extra
port extension is already applied to the raw S parameter and the parts is measured with Pin n connected to
Port n (where n=1, 2, 3, 4).
Maximum power condition
Under the maximum power condition, the symmetrical Doherty architecture requires main amplifier and peak
amplifier to work at full capacity with the optimum termination (50 Ω). The two amplifiers should deliver RF
power of equal magnitude and 90 degree phase difference. Doherty combiner functions as a coherent power
combiner and supplies the 90 degree phase compensation. The following specification is defined with 50 Ω
port impedance at three ports for this condition. The return loss and the insertion loss in max power mode
are not affected by the 50 ohm lossless port rotation mentioned in electrical spec table in page 1. The phase
imbalance and the amplitude imbalance are not affected either since port rotation are taken off equally from
the main and the peak amp port.
Parameter
Return Loss
Insertion Loss
Phase Imbalance
Amplitude Imbalance
Definition
The impedance match at the
combining port to a 50Ω system.
The combined power divided by the
sum of input power under the perfect
combining condition.
The phase difference between PeakCombined path and Main-Combined
path at ωc = 881MHz
The magnitude difference between
Peak-Combined path and MainCombined path.
Low power condition
Mathematical Representation
20log| S11 |
10log(|S13 |2 + |S14 |2 )
Phase (S14 (ωc ))
− Phase (S13 (ωc ))
1
(20log| S14 | − 20log| S13 |)
2
Under low power condition, the Doherty operation turns off peak amplifier and requires main amplifier to be
terminated with double of the optimum impedance (100 Ω). In this configuration, Doherty combiner servers
as an impedance transformer transforming 50 Ω at combining port to 100 Ω at main amplifier port. The
following specification is defined under the port impedance condition of Port 1 (Combining Port) 50 Ω, Port 4
(Main Amp Port) 100 Ω and Port 3 (Peak Amp Port) open. With the peak amp left off, the extra line length in
that port (see figure in page 2) acts as an open stub which shifts the low power mode return loss null and
insertion loss. The offset line length needs to be adjusted taking the port rotation number into consideration
so that the junction of 50 Ω and 35 Ω transmission line sees high impedance instead of the part edge. The
return loss and the insertion loss defined below are after the offset line adjustments specified in the spec tab
Parameter
Definition
Return Loss
The impedance match of
the 50 to100 Ω transformer.
Insertion Loss
The output power divided
by input power.
Mathematical Representation
20log| S11 |
20log| S41 |
6
X3DC08E2S
Rev H
Packaging and Ordering Information:
Parts are available in reel. Packaging follows EIA 481-2. Parts are oriented in tape and reel as shown below.
Minimum order quantities are 2000 per reel.
.079
[2.00]
.012
[0.30]
Ø.059
[Ø1.50]
.157
[4.00]
.069
[1.75]
.453
[11.50]
.591
[15.00]
Ø.059
[Ø1.50]
.228
[5.80]
.315
[8.00]
XX XX
.094
[2.40]
.945
[24.00]
Contact us:
rf&s_support@ttm.com
7
很抱歉,暂时无法提供与“X3DC08E2S”相匹配的价格&库存,您可以联系我们找货