AOZ8224CI-05
Four-line Bi-directional TVS Diode
General Description
Features
The AOZ8224CI-05 is a four-line bi-directional transient
voltage suppressor diode designed to protect voltage
sensitive electronics from high transient conditions and
ESD.
ESD protection for high-speed data lines:
This device incorporates eight TVS diodes in a small
SOT-23 package. It may be used to meet the ESD
immunity requirements of IEC 61000-4-2, Level 4
(± 15 kV air, ± 8 kV contact discharge).
The AOZ8224CI-05 comes in a SOT-23 package and is
rated over a -40°C to +85°C ambient temperature range.
The small SOT-23 package makes the AOZ8224CI-05
ideal for applications where PCB space is a premium.
The small size and high ESD protection is ideal for
protecting voltage sensitive electronics from high
transient conditions and ESD.
– Exceeds IEC 61000-4-2 (ESD) ± 30 kV (air),
± 30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 5 A (8/20 µs)
IEC 61000-4-4 (EFT) ± 40A
Small package saves board space
Low insertion loss
Low clamping voltage
Low operating voltages: 5.0 V
Applications
Portable handheld devices
Keypads, data lines, buttons
Notebook computers
Digital cameras
Portable GPS
MP3 players
Typical Application
Pin Configuration
I/O1
I/O2
4
3
4
5
2
5
1
SOT-23
3
2
1
(Top View)
I/O3
I/O4
Bidirection Protection of Four Lines
Rev. 3.1 September 2021
www.aosmd.com
Page 1 of 4
AOZ8224CI-05
Ordering Information
Part Number
Ambient Temperature Range
Package
Environmental
AOZ8224CI-05
-40°C to +85°C
SOT-23-5L
Green Product
RoHS Compliant
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information.
Absolute Maximum Ratings
Exceeding the Absolute Maximum Ratings may damage the device.
Parameter
AOZ8224CI-05
Peak Pulse Current, tP = 8/20 µs
5A
Peak Pulse Power, tP = 8/20 µs
70 W
Storage Temperature (TS)
-65°C to +150°C
ESD Rating per IEC61000-4-2, Contact(1)
ESD Rating per
± 30 kV
IEC61000-4-2, Air(1)
ESD Rating per Human Body Model
± 30 kV
(2)
± 30 kV
Notes:
1. IEC 61000-4-2 discharge with CDischarge = 150 pF, RDischarge = 330 Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100 pF, RDischarge = 1.5 kΩ.
Maximum Operating Ratings
The device is not guaranteed to operate beyond the Maximum Operating Conditions.
Parameter
Rating
Junction Temperature (TJ)
-40°C to +85°C
Electrical Characteristics
TA = 25°C unless otherwise specified.
Symbol
Parameter
Symbol
Parameter
IPP
Maximum Reverse Peak Pulse Current
IF
Forward Current
VCL
Clamping Voltage @ IPP
VF
Forward Voltage
Working Peak Reverse Voltage
Ppk
Peak Power Dissipation
Maximum Reverse Leakage Current
CJ
Max. Capacitance @ VR = 0 and f = 1 MHz
VRWM
IR
VBR
Breakdown Voltage
Electrical Characteristics
TA = 25°C unless otherwise noted, VF = 1 V Max. @ IF = 15 mA for all types
Device
Device
Marking
VRWM (V)
Max.
VBR (V)
Min @ 5mA
IR (µA)
Max.
VF (V)
Typ.
AOZ8224CI-05
AZ
5.0
5.5
0.1
0.75
Rev. 3.1 September 2021
www.aosmd.com
VCL Max.
IPP = 1 A IPP = 10 A
11.0
15.0
CJ (pF)
Typ.
CJ (pF)
Max.
13.0
14.0
Page 2 of 4
AOZ8224CI-05
Typical Performance Characteristics
ESD Clamping
8kV Contact per IEC61000-4-2
Clamping Voltage vs. Peak Pulse Current
(tperiod = 100 ns, tr = 1 ns)
Clamping Voltage, VCL (V)
30
25
20
15
10
5
0
0
2
4
6
8
10
12
Peak Pulse Current, IPP (A)
Rev. 3.1 September 2021
www.aosmd.com
Note: Data was taken with a 10X attenuator
Page 3 of 4
AOZ8224CI-05
LEGAL DISCLAIMER
Applications or uses as critical components in life support devices or systems are not authorized. Alpha and Omega
Semiconductor does not assume any liability arising out of such applications or uses of its products. AOS reserves
the right to make changes to product specifications without notice. It is the responsibility of the customer to evaluate
suitability of the product for their intended application. Customer shall comply with applicable legal requirements,
including all applicable export control rules, regulations and limitations.
AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at:
http://www.aosmd.com/terms_and_conditions_of_sale
LIFE SUPPORT POLICY
ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant into
the body or (b) support or sustain life, and (c) whose
failure to perform when properly used in accordance
with instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of
the user.
Rev. 3.1 September 2021
2. A critical component in any component of a life
support, device, or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.aosmd.com
Page 4 of 4
很抱歉,暂时无法提供与“AOZ8224CI-05”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+0.43050
- 10+0.37939
- 30+0.35747
- 100+0.33012