AOZ8231ADI
One-line Bi-directional TVS Diode
General Description
Features
The AOZ8231ADI is a one-line bi-directional transient
voltage suppressor diode designed to protect voltage
sensitive electronics from high transient conditions and
ESD.
ESD protection for high-speed data lines
This device incorporates one TVS diode in an ultra-small
DFN 1006 package. It may be used to meet the ESD
immunity requirements of EC 61000-4-2, Level 4
(±15kV air, ±8kV contact discharge).
The AOZ8231ADI comes in a RoHS compliant, HalogenFree DFN 1.0 mm x 0.6 mm package and is rated over a
-40 °C to +85 °C ambient temperature range.
The ultra-small 1.0 mm x 0.6 mm x 0.5 mm DFN package
makes it ideal for applications where PCB space is a
premium. The small size and high ESD protection makes
it ideal for protecting voltage sensitive electronics from
high transient conditions and ESD.
Applications
Portable handheld devices
Keypads, data lines, buttons
Notebook computers
Digital Cameras
Portable GPS
MP3 players
AOZ8231ADI-02:
– Exceeds: IEC 61000-4-2 (ESD) ± 30 kV (air),
± 30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 6 A (8/20 μS)
– IEC 61000-4-4 (EFT) 40 A
AOZ8231ADI-03:
– Exceeds: IEC 61000-4-2 (ESD) ± 30 kV (air),
± 30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 6 A (8/20 μS)
– IEC 61000-4-4 (EFT) 40 A
AOZ8231ADI-05:
– Exceeds: IEC 61000-4-2 (ESD) ± 30 kV (air),
±30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 5 A (8/20 µS)
– IEC 61000-4-4 (EFT) 40 A
AOZ8231ADI-08:
– Exceeds: IEC 61000-4-2 (ESD) ± 30 kV (air),
± 30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 5 A (8/20 µS)
– IEC 61000-4-4 (EFT) 40 A
AOZ8231ADI-12:
– Exceeds: IEC 61000-4-2 (ESD) ± 30 kV (air),
± 30 kV (contact)
– Human Body Model (HBM) ± 30 kV
– IEC 61000-4-5 (Lightning) 4 A (8/20 µS)
– IEC 61000-4-4 (EFT) 40 A
AOZ8231ADI-24:
– Exceeds: IEC 61000-4-2 (ESD) ± 18 kV (air),
± 15 kV (contact)
– Human Body Model (HBM) ± 15 kV
– IEC 61000-4-5 (Lightning) 2.5 A (8/20 µS)
– IEC 61000-4-4 (EFT) 40 A
Small package saves board space
Low insertion loss
Low clamping voltage
Low operating voltage
Pb-free device
Rev. 6.0 June 2021
www.aosmd.com
Page 1 of 5
AOZ8231ADI
Typical Application
Pin Configuration
Signal Line
Bidirection Protection of Single Line
Ordering Information
Part Number
Ambient Temperature Range
Package
Environmental
-40 °C to +85 °C
DFN 1.0 x 0.6
Green Product
AOZ8231ADI-02
AOZ8231ADI-03
AOZ8231ADI-05
AOZ8231ADI-08
AOZ8231ADI-12
AOZ8231ADI-24
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information.
Absolute Maximum Ratings
Exceeding the Absolute Maximum ratings may damage the device.
Rating for AOZ8231ADI
Parameter
VP – VN
Peak Pulse Current, tP = 8/20 µs
-02
-03
-05
-08
-12
2.5 V
3.3 V
5V
8V
12 V
24 V
6A
6A
5A
5A
4A
2.5 A
Storage Temperature (TS)
-65 °C to +150 °C
ESD Rating per IEC61000-4-2, Contact
(1)
(1)
ESD Rating per IEC61000-4-2, Air
ESD Rating per Human Body
-24
Model(2)
± 30 kV
± 30 kV
± 30 kV
± 30 kV
± 30 kV
± 15 kV
± 30 kV
± 30 kV
± 30 kV
± 30 kV
± 30 kV
±18 kV
± 30 kV
± 30 kV
± 30 kV
± 30 kV
± 30 kV
± 15 kV
Notes:
1. IEC 61000-4-2 discharge with CDischarge = 150 pF, RDischarge = 330 Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100 pF, RDischarge = 1.5 kΩ.
Maximum Operating Ratings
Parameter
Junction Temperature (TJ)
Rev. 6.0 June 2021
Rating
-40 °C to +125 °C
www.aosmd.com
Page 2 of 5
AOZ8231ADI
Electrical Characteristics
TA = 25 °C unless otherwise specified.
Symbol
Parameter
Diagram
IPP
Reverse Peak Pulse Current, (tperiod = 100 ns, tr = 1 ns)
VCL
Clamping Voltage @ IPP
VRWM
IR
VBR
CJ
I
IPP
Working Peak Reverse Voltage
Maximum Reverse Leakage Current
Breakdown Voltage
VCL VBR VRWM
IR
IT
Capacitance @ VR = 0 and f = 1 MHz
VCL VBR VRWM
V
IPP
VCL Max.(3)
IR (µA)
Max. IPP = 1 A IPP = 5 A IPP = 12 A
Device
Device
Marking
VRWM (V)
Max.
VBR (V)
Min. @
1mA
AOZ8231ADI-02
P
2.5
3.0
0.1
AOZ8231ADI-03
D
3.3
3.7
AOZ8231ADI-05
E
5.0
5.5
AOZ8231ADI-08
Y
8.0
AOZ8231ADI-12
F
AOZ8231ADI-24
R
12.5
CJ (pF)(3)
Min.
Typ.
Max.
4.4
5.5
7.0
6.5
9.0
0.1
7.5
10.0
13.5
4.4
5.5
7.0
0.1
10.5
13.5
15.5
10.4
13.0
14.0
9.5
0.1
15.0
18.0
22.5
19.0
23.0
27.0
12.0
13.0
0.1
20.0
23.0
26.0
10.4
13.0
14.0
24.0
27.0
0.1
35.0
38.0
39.0
9.6
12.0
15.0
Note:
3. Guaranteed by design and characterization.
Rev. 6.0 June 2021
www.aosmd.com
Page 3 of 5
AOZ8231ADI
Typical Performance Characteristics
Clamping Voltage vs. Peak Pulse Current
(tperiod = 100 ns, tr = 1 ns)
45
Clamping Voltage, VCL (V)
40
24V
35
30
12V
25
8V
20
15
5V
3.3V
10
2.5V
5
0
0
2
4
6
8
10
12
Peak Pulse Current, IPP (A)
Typical Variation of CIN vs. VR
(f = 1 MHz, T = 25 °C)
Normalized Capacitance (pF)
1.2
1.0
2.5V
3.3V
0.8
0.6
5V
24V
0.4
12V
0.2
0
0
2
4
6
8
10
12
14
16
18
20
22
24
Input Voltage (V)
Rev. 6.0 June 2021
www.aosmd.com
Page 4 of 5
AOZ8231ADI
LEGAL DISCLAIMER
Applications or uses as critical components in life support devices or systems are not authorized. AOS does not
assume any liability arising out of such applications or uses of its products. AOS reserves the right to make changes to
product specifications without notice. It is the responsibility of the customer to evaluate suitability of the product for
their intended application. Customer shall comply with applicable legal requirements, including all applicable export
control rules, regulations and limitations.
AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at:
http://www.aosmd.com/terms_and_conditions_of_sale
LIFE SUPPORT POLICY
ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant into
the body or (b) support or sustain life, and (c) whose
failure to perform when properly used in accordance
with instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of
the user.
Rev. 6.0 June 2021
2. A critical component in any component of a life
support, device, or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.aosmd.com
Page 5 of 5
很抱歉,暂时无法提供与“AOZ8231ADI-12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 5+1.493925+0.18532
- 25+0.8836025+0.10961
- 100+0.70142100+0.08701
- 500+0.65587500+0.08136
- 3000+0.610323000+0.07571