AOZ8831ADI-05
Ultra Low Capacitance One-line
Bidirectional TVS Diode
General Description
Features
The AOZ8831ADI-05 is an ultra low capacitance one-line
bidirectional transient voltage suppressor diode designed
to protect high speed data lines and voltage sensitive
electronics from high transient conditions and ESD.
ESD protection for high-speed data lines:
This device incorporates one bidirectional TVS diode in an
ultra-small DFN 1.0x0.6 footprint package. It may be
used to meet the ESD immunity requirements of IEC
61000-4-2, Level 4 (±15kV air, ±15kV contact discharge).
Small package saves board space
The AOZ8831ADI-05 comes in an RoHS compliant
package and is rated over a -40°C to +85°C ambient
temperature range.
Pb-free device
The ultra-small 1.0 x 0.6 x 0.5mm DFN package makes it
ideal for applications where PCB space is a premium.
The small size and high ESD protection makes it ideal for
protecting voltage sensitive electronics from high
transient conditions and ESD.
Portable handheld devices
– Exceeds: IEC 61000-4-2 (ESD), ±25kV (contact),
±30kV (air)
– Human Body Model (HBM) ±25kV
Ultra low capacitance: 0.30pF
Low clamping voltage
Low operating voltage: 5.0V
Applications
Keypads, data lines, buttons
Notebook computers
Digital cameras
Portable GPS
MP3 players
Typical Application
Pin Configuration
Signal Line
1
2
Bidirection Protection of Single Line
Rev. 7.0 June 2021
www.aosmd.com
Page 1 of 5
AOZ8831ADI-05
Ordering Information
Part Number
Ambient Temperature Range
Package
Environmental
AOZ8831ADI-05
-40°C to +85°C
DFN 1.0 x 0.6
Green Product
RoHS Compliant
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information.
Absolute Maximum Ratings
Exceeding the Absolute Maximum Ratings may damage the device.
Parameter
Rating
VP – VN
5V
Peak Pulse Current (IPP), tP = 8/20µs
2.5A
Peak Pulse Power, tP = 8/20µs
40W
Storage Temperature (TS)
-65°C to +150°C
ESD Rating per IEC61000-4-2,
ESD Rating per
Contact(1)
±25kV
IEC61000-4-2, Air(1)
ESD Rating per Human Body
±30kV
Model(2)
±25kV
Notes:
1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ.
Maximum Operating Conditions
The device is not guaranteed to operate beyond the Maximum Operating Conditions.
Parameter
Rating
Junction Temperature (TJ)
Rev. 7.0 June 2021
-40°C to +125°C
www.aosmd.com
Page 2 of 5
AOZ8831ADI-05
Electrical Characteristics
TA = 25°C unless otherwise specified.
Symbol
IPP
Parameter
Diagram
Maximum Reverse Peak Pulse Current
(100ns Transmission Line Pulse (TLP))
VCL
Clamping Voltage @ IPP
VSURGE_MAX
Peak Voltage at ISURGE = 2A
(IEC61000-40-5 8/20µs pulse current)
VRWM
Working Peak Reverse Voltage
IR
Maximum Reverse Leakage Current
VBR
Breakdown Voltage
PPK
Peak Power Dissipation
CJ
Capacitance @ VR = 0 and f = 1MHz
Device
AOZ8831ADI-05
Rev. 7.0 June 2021
I
IPP
VCL VBR VRWM
IR
IT
VRWM VBR VCL
V
IPP
VBR (V)
VCL Max.
CJ (pF)
IR (nA) VSURGE (V)
Device VRWM (V)
IPP = 1A IPP = 2A IPP = 5A Typ. Max.
Max.
Max.
Marking
Min. Max. Max.
T
5.0
6.0
10.0
50.0
15.5
www.aosmd.com
14.0
16.0
19.5
0.30
0.45
Page 3 of 5
AOZ8831ADI-05
Typical Performance Characteristics
Clamping Voltage vs. Peak Pulse Current
5
0
25
Insertion Loss (dB)
Clamping Voltage, VCL (V)
Insertion Loss (S21) vs. Frequency
(tperiod = 100ns, tr = 1ns)
30
20
15
-5
-10
-15
-20
-25
10
0
2
4
6
8
10
1
12
10
100
1000
10000
Frequency (MHz)
Peak Pulse Current, IPP (A)
Typical Variation of CIN vs. VR
(f = 1MHz, T = 25C)
0.8
Input Capacitance (pF)
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
1
2
3
4
5
Input Voltage (V)
Rev. 7.0 June 2021
www.aosmd.com
Page 4 of 5
AOZ8831ADI-05
LEGAL DISCLAIMER
Applications or uses as critical components in life support devices or systems are not authorized. AOS does not
assume any liability arising out of such applications or uses of its products. AOS reserves the right to make changes
to product specifications without notice. It is the responsibility of the customer to evaluate suitability of the product
for their intended application. Customer shall comply with applicable legal requirements, including all applicable
export control rules, regulations and limitations.
AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at:
http://www.aosmd.com/terms_and_conditions_of_sale
LIFE SUPPORT POLICY
ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant into
the body or (b) support or sustain life, and (c) whose
failure to perform when properly used in accordance
with instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of
the user.
Rev. 7.0 June 2021
2. A critical component in any component of a life
support, device, or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.aosmd.com
Page 5 of 5
很抱歉,暂时无法提供与“AOZ8831ADI-05”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 3+1.63260
- 25+0.81930
- 100+0.72227
- 171+0.62166
- 468+0.58812
- 3000+0.57614