AOZ8831DT-24

AOZ8831DT-24

  • 厂商:

    AOSMD(美国万代)

  • 封装:

    SOD993B

  • 描述:

  • 数据手册
  • 价格&库存
AOZ8831DT-24 数据手册
AOZ8831DT-24 Ultra Low Capacitance One-line Bi-directional TVS Diode General Description Features The AOZ8831DT-24 is an ultra low capacitance one-line bi-directional transient voltage suppressor diode designed to protect high speed data lines and voltage sensitive electronics from high transient conditions and ESD.  This device incorporates one TVS diode in an ultra-small DFN 1.0 x 0.6 package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4 (±15kV air, ±13kV contact discharge). The AOZ8831DT-24 comes in an RoHS compliant DFN package and is rated over a -40°C to +85°C ambient temperature range. ESD protection for high-speed data lines: – Exceeds: IEC 61000-4-2 (ESD) ±15kV (air), ±13kV (contact) – Human Body Model (HBM) ±15kV  Small package saves board space  Ultra low capacitance: 0.35pF  Low clamping voltage  Operating voltage: 24V  Pb-free device Applications  Portable handheld devices The ultra-small 1.0 x 0.6mm DFN package makes it ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD.  Notebook computers  Digital Cameras  Portable GPS Typical Application Pin Configuration Signal Line 1 2 Bidirection Protection of Single Line Rev. 4.0 April 2021 www.aosmd.com Page 1 of 5 AOZ8831DT-24 Ordering Information Part Number Ambient Temperature Range Package Environmental AOZ8831DT-24 -40°C to +85°C DFN 1.0 x 0.6 Green Product AOS Green Products use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information Absolute Maximum Ratings Exceeding the Absolute Maximum ratings may damage the device. Parameter Rating VP – VN 24V Peak Pulse Current (IPP), tP = 8/20µs 1.2A Peak Pulse Power, tP = 8/20µs 60W Storage Temperature (TS) -65°C to +150°C ESD Rating per IEC61000-4-2, ESD Rating per Contact(1) ±13kV IEC61000-4-2, Air(1) ESD Rating per Human Body ±15kV Model(2) ±15kV Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ. Maximum Operating Ratings Parameter Rating Junction Temperature (TJ) Rev. 4.0 April 2021 -40°C to +125°C www.aosmd.com Page 2 of 5 AOZ8831DT-24 Electrical Characteristics TA = 25°C unless otherwise specified. Symbol Parameter Diagram IPP Maximum Reverse Peak Pulse Current(3) (100ns Transmission Line Pulse (TLP)) VCL Clamping Voltage @ IPP(3) VP Peak Voltage (IEC61000-4-5 8/20µs, Surge Current IPEAK = 1A) VRWM IR VBR CJ I IPP Working Peak Reverse Voltage VCL VBR VRWM IR IT VRWM VBR VCL V Maximum Reverse Leakage Current Breakdown Voltage IPP Capacitance @ VR = 0 and f = 1MHz Device AOZ8831DT-24 Device VRWM (V) VBR (V) Max. Min. Marking 2 24 26 VCL Max. VP (V) CJ (pF) IR (µA) Max. IPP = 1A IPP = 2A IPP = 5A Max. Min. Typ. Max. 0.1 38 40 48 45 0.2 0.35 0.5 Notes: 3. These specifications are guaranteed by design and characterization. Rev. 4.0 April 2021 www.aosmd.com Page 3 of 5 AOZ8831DT-24 Typical Performance Characteristics Clamping Voltage vs. Peak Pulse Current Typical Variations of CIN vs. VR (tperiod = 100ns, tr = 1ns) 50 0.9 Normalized Capacitance (pF) 48 Clamping Voltage, VCL (V) (f = 1MHz, T = 25ºC) 1.0 46 44 42 40 38 36 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 34 0 1 Rev. 4.0 April 2021 2 3 4 Peak Pulse Current, IPP (A) 5 6 www.aosmd.com 0 2 4 6 8 10 12 14 16 Input Voltage (V) 18 20 22 24 Page 4 of 5 AOZ8831DT-24 LEGAL DISCLAIMER Applications or uses as critical components in life support devices or systems are not authorized. AOS does not assume any liability arising out of such applications or uses of its products. AOS reserves the right to make changes to product specifications without notice. It is the responsibility of the customer to evaluate suitability of the product for their intended application. Customer shall comply with applicable legal requirements, including all applicable export control rules, regulations and limitations. AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at: http://www.aosmd.com/terms_and_conditions_of_sale LIFE SUPPORT POLICY ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 4.0 April 2021 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 5 of 5
AOZ8831DT-24 价格&库存

很抱歉,暂时无法提供与“AOZ8831DT-24”相匹配的价格&库存,您可以联系我们找货

免费人工找货
AOZ8831DT-24
  •  国内价格
  • 10000+0.57976

库存:0