AOZ8831DT-24
Ultra Low Capacitance One-line
Bi-directional TVS Diode
General Description
Features
The AOZ8831DT-24 is an ultra low capacitance one-line
bi-directional transient voltage suppressor diode
designed to protect high speed data lines and voltage
sensitive electronics from high transient conditions and
ESD.
This device incorporates one TVS diode in an ultra-small
DFN 1.0 x 0.6 package. It may be used to meet the ESD
immunity requirements of IEC 61000-4-2, Level 4
(±15kV air, ±13kV contact discharge).
The AOZ8831DT-24 comes in an RoHS compliant DFN
package and is rated over a -40°C to +85°C ambient
temperature range.
ESD protection for high-speed data lines:
– Exceeds: IEC 61000-4-2 (ESD) ±15kV (air),
±13kV (contact)
– Human Body Model (HBM) ±15kV
Small package saves board space
Ultra low capacitance: 0.35pF
Low clamping voltage
Operating voltage: 24V
Pb-free device
Applications
Portable handheld devices
The ultra-small 1.0 x 0.6mm DFN package makes it ideal
for applications where PCB space is a premium. The
small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient
conditions and ESD.
Notebook computers
Digital Cameras
Portable GPS
Typical Application
Pin Configuration
Signal Line
1
2
Bidirection Protection of Single Line
Rev. 4.0 April 2021
www.aosmd.com
Page 1 of 5
AOZ8831DT-24
Ordering Information
Part Number
Ambient Temperature Range
Package
Environmental
AOZ8831DT-24
-40°C to +85°C
DFN 1.0 x 0.6
Green Product
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information
Absolute Maximum Ratings
Exceeding the Absolute Maximum ratings may damage the device.
Parameter
Rating
VP – VN
24V
Peak Pulse Current (IPP), tP = 8/20µs
1.2A
Peak Pulse Power, tP = 8/20µs
60W
Storage Temperature (TS)
-65°C to +150°C
ESD Rating per IEC61000-4-2,
ESD Rating per
Contact(1)
±13kV
IEC61000-4-2, Air(1)
ESD Rating per Human Body
±15kV
Model(2)
±15kV
Notes:
1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ.
Maximum Operating Ratings
Parameter
Rating
Junction Temperature (TJ)
Rev. 4.0 April 2021
-40°C to +125°C
www.aosmd.com
Page 2 of 5
AOZ8831DT-24
Electrical Characteristics
TA = 25°C unless otherwise specified.
Symbol
Parameter
Diagram
IPP
Maximum Reverse Peak Pulse Current(3)
(100ns Transmission Line Pulse (TLP))
VCL
Clamping Voltage @ IPP(3)
VP
Peak Voltage (IEC61000-4-5 8/20µs, Surge Current
IPEAK = 1A)
VRWM
IR
VBR
CJ
I
IPP
Working Peak Reverse Voltage
VCL VBR VRWM
IR
IT
VRWM VBR VCL
V
Maximum Reverse Leakage Current
Breakdown Voltage
IPP
Capacitance @ VR = 0 and f = 1MHz
Device
AOZ8831DT-24
Device VRWM (V) VBR (V)
Max.
Min.
Marking
2
24
26
VCL Max.
VP (V)
CJ (pF)
IR (µA)
Max. IPP = 1A IPP = 2A IPP = 5A Max. Min. Typ. Max.
0.1
38
40
48
45
0.2
0.35
0.5
Notes:
3. These specifications are guaranteed by design and characterization.
Rev. 4.0 April 2021
www.aosmd.com
Page 3 of 5
AOZ8831DT-24
Typical Performance Characteristics
Clamping Voltage vs. Peak Pulse Current
Typical Variations of CIN vs. VR
(tperiod = 100ns, tr = 1ns)
50
0.9
Normalized Capacitance (pF)
48
Clamping Voltage, VCL (V)
(f = 1MHz, T = 25ºC)
1.0
46
44
42
40
38
36
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
34
0
1
Rev. 4.0 April 2021
2
3
4
Peak Pulse Current, IPP (A)
5
6
www.aosmd.com
0
2
4
6
8
10 12 14 16
Input Voltage (V)
18
20
22
24
Page 4 of 5
AOZ8831DT-24
LEGAL DISCLAIMER
Applications or uses as critical components in life support devices or systems are not authorized. AOS does not
assume any liability arising out of such applications or uses of its products. AOS reserves the right to make changes
to product specifications without notice. It is the responsibility of the customer to evaluate suitability of the product
for their intended application. Customer shall comply with applicable legal requirements, including all applicable
export control rules, regulations and limitations.
AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at:
http://www.aosmd.com/terms_and_conditions_of_sale
LIFE SUPPORT POLICY
ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant into
the body or (b) support or sustain life, and (c) whose
failure to perform when properly used in accordance
with instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of
the user.
Rev. 4.0 April 2021
2. A critical component in any component of a life
support, device, or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.aosmd.com
Page 5 of 5
很抱歉,暂时无法提供与“AOZ8831DT-24”相匹配的价格&库存,您可以联系我们找货
免费人工找货