AGF600-24S28-6L

AGF600-24S28-6L

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

    -

  • 描述:

    DC/DCCONVERTER28V600W

  • 数据手册
  • 价格&库存
AGF600-24S28-6L 数据手册
24Vdc Input, 28Vdc@21.5A Output Full-brick DC-DC Converter AGF600-24S28 Description The AGF600-24S28 is a single output DC-DC converter with standard full-brick outline and pin configuration. It delivers up to 21.5A output current with 28V output voltage. Above 93.5% ultra-high efficiency and excellent thermal performance make it an ideal choice to supply power to power amplifier in telecom RF application. Thanks to the aluminium baseplate it can work under -40°C ~ +85°C without air cooling. Operational Features z z z z z z z Delivering up to 21.5A output current Ultra-high efficiency 93.5% typ. at half load Excellent thermal performance Wide input range: 18V ~ 36V No minimum load requirement Fixed frequency operation RoHS 6 compliant Control Features z z z Remote control function Remote output sense Trim function: -50% ~ +18% Mechanical Features z z z Industry standard full-brick pin-out outline With aluminium baseplate Pin length: 3.8mm Safety & EMC z z z z Meets safety standards UL 60950-1, IEC/EN 60950-1 and GB4943 Approved by UL and TUV Meets 2006/95/EEC and 93/68/EEC directives which facilitates CE marking in user’s end product Meets conducted emission's requirements of EN55022 Class A with external filter Protection Features z z z z Input under voltage protection Output over current protection Output over voltage protection Over temperature protection Document No. 31020951 July 10, 2009 Rev 1.1 AGF600-24S28 DC-DC Converter 2/14 Electrical Characteristics Full operating ambient temperature range is -40°C to +85°C. Specifications are subject to change without notice. Parameter Min. Typ. Max. Unit Notes & Conditions Absolute max. ratings Input voltage Non-operating 50 V 100ms Operating 36 V Continuous Operating temperature -40 85 °C Storage temperature -55 125 °C Input characteristics Operating input voltage range Input under-voltage lockout 18 24 36 V Turn-on voltage threshold 15 18 V Turn-off voltage threshold 14 17 V Lockout voltage hysteresis 1 3 V 40 A 18Vin, full load Max. input current No-load input current 0.5 0.7 A 24Vin Standby Input current 0.05 0.1 A Remote OFF Inrush current transient rating 0.5 1 A2s Figure 18 320 mA Through 12μH inductor; Figure 18 Input reflected ripple current Recommended input fuse 60 A Fast blow external fuse recommended Figure 13 Input filter component values (C\L) 4.7*13\0.35 μF\μH Internal values Recommended external input capacitance 1000 μF Low ESR capacitor recommended Figure 13 24Vin, full load Output characteristics Output voltage set point (standard option) Output voltage line regulation Output voltage load regulation 27.72 28 28.28 V 0.1 0.2 % 28 56 mV 0.2 0.5 % 56 140 mV http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter Parameter 3/14 Min. Typ. Output voltage temperature regulation Total output voltage range 27.20 28 Output voltage ripple and noise Max. Unit 0.02 %/°C 28.80 V Over sample, line, load, temperature & life 200 mVpp 20MHz bandwidth; Figure 18 Operating output current range 0 21.5 A Output DC current-limit inception 23.65 30.1 A Output capacitance 470 10000 μF 1000 Notes & Conditions Hiccup, see Figure 12 Dynamic characteristics Dynamic response Turn-on transient Figure 6 25% ~ 50% ~ 25% Io,max, 0.1A/μs 840 mV Settling time 500 μs 50% ~ 75% ~ 50% Io,max, 0.1A/μs 840 mV Settling time 500 μs Recovery to within 1% Vo,nom Full load, Figure 8 Rise time 20 200 ms Turn-on delay time 0 200 ms 5 %Vo Output voltage overshoot Test condition: see Figure 13 Recovery to within 1% Vo,nom Figure 7 Test condition: see Figure 13 Efficiency 100% load 92.0 % Figure 1 50% load 93.5 % Figure 1 Electrical Characteristics (Continued) Parameter Min. Typ. Max. Unit Notes & Conditions Isolation characteristics Isolation voltage (1mA, 5s) 1500 V Basic insulation, pollution degree 2, input to output 1500 V Basic insulation, pollution degree 2, input to baseplate 500 V Basic insulation, pollution degree 2, output to baseplate http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter Parameter Min. Typ. 4/14 Max. Unit Notes & Conditions Feature characteristics Switching frequency 230 Remote ON/OFF control Output voltage trim range 260 290 kHz 1.5 5 mA See Figure 14 and Figure 15 14 33 V See Trim Characteristics of Application Note 1 V 143 % 130 °C Output voltage remote sense range Output over-voltage protection 125 Over-temperature shutdown 105 Over-temperature hysteresis 5 115 Over full temp range; % of Vo,nom Latch:reset by power on or remote on Auto recovery; Test point: see Figure 21 °C Reliability characteristics Calculated MTBF (telcordia ) 1.5 106h Telcordia SR-332-2006; 80% load, 300LFM, 40°C Ta Qualification Testing Parameter Unit (pcs) Test condition Halt test 4~5 Ta,min-10°C to Ta,max+10°C, 5°C step, Vin = min to max, 0 ~ 105% load Vibration 3 Frequency range: 5Hz ~ 20Hz, 20Hz ~ 200Hz, A.S.D: 1.0m2/s3, -3db/oct, axes of vibration: X/Y/Z;Time: 30min/axis Mechanical shock 3 30g, 6ms, 3axes, 6directions, 3time/direction Thermal shock 3 -40°C to 100°C, unit temperature 20cycles Thermal cycling 3 -40°C to 85°C, temperature change rate: 1°C/min, cycles: 2cycles Humidity 3 40°C, 95%RH, 48h Solder ability 15 IPC J-STD-002C-2007 http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter 5/14 Characteristic Curves 100 Efficiency(%) 95 90 85 Vin=18V Vin=24V Vin=36V 80 75 70 2.15 4.3 6.45 8.6 10.75 12.9 15.05 17.2 19.35 21.5 Iout(A) Figure 1 Efficiency vs. output current, Ta=25°C, Vo=28V IO 21.5A 100° C TC Figure 2 Output power derating curve Tc: temperature test point on baseplate, see Figure 21 for test configuration. Figure 3 Thermal image, 24Vin, 28Vo, full load, room temperature http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter 6/14 Figure 4 Output ripple & noise (5μs/div, 100mV/div), see Figure 18 for test configuration Figure 5 Input reflected ripple current (5μs/div, 20mA/div), see Figure 18 for test configuration Figure 6 Dynamic response for 25% load step (25% ~ 50% ~ 75%) and 0.1A/μs slew rate, see Figure 13 for test configuration, CH1-output voltage (500mV/div); CH2-output current (5A/div) Figure 7 Dynamic response for 25% load step (50% ~ 75% ~ 50%) and 0.1A/μs slew rate, see Figure 13 for test configuration. CH1-output voltage (500mV/div); CH2-output current (5A/div) Figure 8 Output voltage startup by power on, (20ms/div), see Figure 13 for test configuration, CH1-input voltage (10V/div); CH2-output voltage (10V/div) Figure 9 Output voltage shut down by power off, (2ms/div), see Figure 13 for test configuration, CH1-input voltage (10V/div); CH2-output voltage (10V/div) http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter Figure10 Output voltage startup by remote ON, (10ms/div), see Figure 14 for test configuration, CH1-remote ON (2V/div); CH2-output voltage (10V/div) 7/14 Figure 11 Output voltage shutdown by remote OFF, (2ms/div), see Figure 14 for test configuration, CH1-remote OFF (2V/div); CH2-output voltage (10V/div) Vo 28V 15V 0V 0A 21.5A 23.65A 28A Io Figure 12 Over-current protection characteristics (It’s only a sketch map of OCP action. Little alteration of the current value vs. voltage value would be allowed.) http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter 8/14 Application Note Typical Application AGF600 Fuse EMI Filter In+ Out+ Vdc Vin+ C1 C2 R1 Vo+ S+ Trim C3 C4 Load SIn- Out- Vin- Vo- +ON/OFF -ON/OFF Figure 13 Typical application R1: 10kΩ (1W) current limiting resistor C1: 1000μF/50V electrolytic capacitor, P/N: UPW2A471MHD (Nichicon) or equivalent caps C2, C3: 1μF/100V X7R ceramic capacitor, P/N: C3225X7R2A105KT0L0U(TDK) or equivalent caps C4: 7X150μF electrolytic capacitor, P/N: UUD1H151MNL1GS (Nichicon) or equivalent caps Note: If ambient temperature is below -5°C, additional 1000μF electrolytic capacitor is needed for output. Fuse: External fast blow fuse with a rating of 60A. The recommended fuse model is F60AH (100/250V). Remote ON/OFF A remote ON/OFF control circuit is provided which is isolated from the input side, as well as, the output side. (Isolation withstand voltage: 1.5kV) Connection of remote ON/OFF terminal is shown in the Figure 14. Output voltage turns remote on when current is made to flow through remote ON/OFF terminal. Remote ON/OFF terminal can be controlled by opening or closing connections (with switch or relay). Maximum source current for remote ON/OFF terminal is 5mA. Therefore, current limiting resistor value must be set such that this maximum source current value is not exceeded. Also, the allowable maximum reverse current flow is 5mA. Controlling the remote ON/OFF terminal from the input side Connect current limiting resistor R1 as shown in Figure 14. http://www.emersonnetworkpower.com.cn AGF600-24S28 DC-DC Converter 9/14 Fuse +Vin R1 C1 -Vin +ON/OFF SW 1k PC 1(ON/OFF) -ON/OFF Figure 14 Connection of remote ON/OFF control (A) R1: Recommended resistor value: 10kΩ (1W) Controlling the remote ON/OFF terminal from the output side Connect the current limiting resistor R1 as shown in Figure 15. AUX R1 SW 1(ON/OFF) -S +ON/OFF 1k -ON/OFF Figure 15 Connection of remote ON/OFF control (B) R1: Recommended resistor Value: 2kΩ (1/2W) Note: 1. A decoupling capacitor of about 0.1µF between the +remote ON/OFF terminal and –remote ON/OFF terminal is needed when input wiring is too long. 2. Current limiting resistor can also be connected to the –remote ON/OFF terminal side. Remote ON/OFF level Output status Open (
AGF600-24S28-6L 价格&库存

很抱歉,暂时无法提供与“AGF600-24S28-6L”相匹配的价格&库存,您可以联系我们找货

免费人工找货