AGQ300-48S1V2 DC/DC Converter TRN
AGQ300-48S1V2 DC/DC Converter
Technical Reference Notes
Industry standard quarter brick: 36V~75V input, 1.2V single output
Features
Industry standard quarter brick (open-frame)
2.28” × 1.45’’ × 0.4’’ (open-frame)
2.28” × 1.45” × 0.5” (with baseplate)
Options
•
•
Choice of positive logic or negative logic
for CNT function
Choice of short pins or long pins
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Industry standard quarter brick
Basic isolation
Ultra high efficiency
Improved thermal performance
High power density
Low output noise
Industry standard pinout
2:1 wide input voltage of 36V~75V
CNT function
Remote sense
Trim function
Over-temperature protection
Output over-current protection (hiccup)
Output over-voltage protection (hiccup)
RoHS compliant
Description
AGQ300-48S1V2 is a new open-frame DC/DC converter for optimum efficiency and power density.
AGQ300-48S1V2 is an industry standard quarter brick, which makes it an ideal choice for small
space, high current and low voltage applications. The package size is 57.9mm × 36.8mm × 10.1mm
(2.28” × 1.45” × 0.4”) for open-frame and 57.9mm × 36.8mm × 12.7mm (2.28” × 1.45” × 0.5”) with
baseplate, and standard pinout configuration provides CNT and trim functions. AGQ300-48S1V2
can provide 1.2@60A single output that is isolated from inputs. The module can achieve ultra high
efficiency, for most applications a heatsink is not required.
Document No.: 31020734
October 29, 2009
Rev 1.4
AGQ300-48S1V2 DC/DC Converter TRN
Module Numbering
http://www.emersonnetworkpower.com.cn
AGQ300-48S1V2 DC/DC Converter TRN
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage and temperature
conditions. Standard test condition on a single unit is as follows:
Tc (board): 25°C
+Vin:
-Vin:
CNT:
48V±2%
Return pin for +Vin
Connect to -Vin for negative logic
Open for positive logic
+Vout:
Connect to load
Connect to load (return)
-Vout:
+Sense:
Connect to +Vout
-Sense:
Connect to -Vout
Trim (Vadj): Open
Input Specifications
Parameter
Symbol
Operating input voltage
Maximum input current
(VI=0 to VI,max, Io=Io,max)
Input reflected-ripple current
(rated input and output)
Supply voltage rejection (120Hz)
Min
Typ
Max
Unit
VI
36
48
75
Vdc
II,max
-
-
2.5
A
II
-
10
20
mAp-p
-
50
60
-
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
http://www.emersonnetworkpower.com.cn
AGQ300-48S1V2 DC/DC Converter TRN
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device.
These are absolute stress ratings only. Functional operation of the device is not implied at these or
any other conditions in excess of those given in the operational sections of the IPS. Exposure to
absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Symbol
Min
Typ
Max
Unit
Continuous
VI
-
-
80
Vdc
Transient (100ms)
VI, trans
-
-
100
Vdc
Ta
-40
-
85
ºC
Operating board temperature
Tc
-
-
-
ºC
Storage temperature
TSTG
-55
-
125
ºC
Operating humidity
-
5
-
95
RH%
Basic input-output isolation
-
2000
Vdc
Output power
Po,max
-
-
72
W
-
-
-
100
mVp-p
(f
很抱歉,暂时无法提供与“AGQ300-48S1V2P-4L”相匹配的价格&库存,您可以联系我们找货