AVE360-48S12 DC/DC Converter TRN
AVE360-48S12 DC/DC Converter
Technical Reference Note
Industry Standard Half Brick: 36~75V Input, 12V Single Output
Features
Industry Standard Half Brick: 2.4” X 2.28’’ X 0.5’’
Options
•
•
Choice of positive logic or negative logic
for CNT function
Choice of short pins or long pins
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Delivers up to 30A output current
Basic isolation
Ultra High efficiency
Improved thermal performance:
High power density
Low output noise
2:1 wide input voltage of 36-75V
CNT function
Remote sense
Trim function: +10%/-10%
Input under-voltage lockout
Output over-current protection
Output over-voltage protection
Over-temperature protection
Description
The AVE360-48S12 is a new DC/DC converter for optimum efficiency and power density.
AVE360-48S12 provides up to 30A output current in an industry standard Half Brick, which makes it
an ideal choice for small space and high power applications. AVE360-48S12 uses an industry
standard half brick 61.0mm × 57.9mm × 12.7mm (2.4”x2.28”x0.5”), provides CNT and trim functions.
AVE360-48S12 can provide 12V@30A, single output and output is isolated from input.
TEL: (86) 755-86010808
BOM: 31020718
www.emersonnetworkpower.com.cn
DATE: 2008-04-29
1/19
REV1.2
AVE360-48S12 DC/DC Converter TRN
Module Numbering
AVE 360 - 48 S 12
P - 4
Pin length: -4---4.80 mm ± 0.5mm
-6---3.80 mm ± 0.5mm
-8---2.80 mm + 0.5 mm/-0.3 mm
Default is 5.80 mm ± 0.5mm
CNT logic, P---positive, open frame, by default:
negative, open frame
Output rated voltage: 12---12V
Output number: S ---single output, D---dual output
Input rated voltage
Output rated power
Series name
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
2/19
AVE360-48S12 DC/DC Converter TRN
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage and temperature
conditions. Standard test condition on a single unit is as following:
Ta:
25°C
+Vin:
48V ± 2%
-Vin:
return pin for +Vin
CNT:
connect to -Vin
+Vout:
connect to load
-Vout:
connect to load (return)
+Sense:
connect to +Vout
-Sense:
connect to -Vout
Trim (Vadj): open
Input Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Note
Operating Input Voltage
VI
36
48
75
VDC
Inrush transient
-
-
-
2
A2s
-
Input Reflected-ripple Current
II
-
50
80
mAp-p
5Hz to 20MHz: 12µH source
impedance, TA = 25ºC.
-
CAUTION: This power module is not internally fused. An input line fuse must always be used.
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
3/19
AVE360-48S12 DC/DC Converter TRN
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device.
These are absolute stress ratings only. Functional operation of the device is not implied at these or
any other conditions in excess of those given in the operational sections of the IPS. Exposure to
absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Symbol
Min
Typ
Max
Unit
Note
Continuous
VI
0
-
80
Vdc
-
Transient
VI, trans
0
-
100
Vdc
100ms
Operating Ambient Temperature
Ta
-40
25
85
ºC
See Thermal Consideration
Operating Board Temperature
Tc
-
135
ºC
Near temperature sensor Rt
Storage Temperature
TSTG
-55
25
125
ºC
-
Operating Humidity
-
5
-
95
%
-
Basic Input-Output Isolation
-
1,500
-
-
Vdc
1mA for 5 sec, slew rate of
1,500V/10sec
Output Power
Po,max
-
-
360
W
-
Input Voltage
TEL: (86) 755-86010808
www.emersonnetworkpower.com.cn
4/19
AVE360-48S12 DC/DC Converter TRN
Output Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Conditions
mVp-p
Output Ripple& Noise
-
-
-
300
External Load Capacitance
-
680
2200
10000
μF
(Ta: 25ºC, Vin: 48V,
30000μF can start-up)
Output Voltage Setpoint
Vo,set
11.8
12
12.2
Vdc
Rating input@ Ionom
-
-
-
0.3
%Vo
-
-
-
0.5
%Vo
-
-
-
0.02
%Vo/ºC
Io
0
10
30
A
-
Io
31.5
-
45
A
-
Line
(Vi,min to Vi,max)
Whole range
(f
很抱歉,暂时无法提供与“AVE360-48S12-4”相匹配的价格&库存,您可以联系我们找货