CL40 SERIES Single and triple output Recommended for new design-ins • • • • • • • 85VAC to 264VAC universal input range Pre-approved SELV power solution Up to 40W continuous output power Up to 50W peak output power UL, CSA, VDE and BABT approved VDE0871-A conducted noise performance Stand alone "listed" equipment [ 2 YEAR WARRANTY ] The CL40 series is a family of 40W (50W peak) external switching power supplies. The CL40 enables the system specifier to optimise the design for several reasons. Firstly, because the power supply offers pre-approved SELV (Safety Extra Low Voltage) outputs, the submission of the apparatus for safety approval is simplified. This represents a significant saving of time and money. Secondly, the task of integrating the power supply into the mechanical design is eliminated, presenting further savings in time and money by ensuring a shorter and simpler design cycle. This means that your product gets to market faster. These advantages are complemented by universal input, CE mark, IEC950, UL, CSA, VDE and BABT approvals, to complete a worldwide packaged power solution suitable for a wide variety of low power, desktop applications. SPECIFICATION OUTPUT SPECIFICATIONS Line regulation LL to HL, FL Total regulation NL to FL (Note 5) Overshoot/undershoot Transient response (Single output model) All specifications are typical at nominal input, full load at 25°C unless otherwise stated ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS ±0.2% ±0.2% ±1.0% ±5.0% ±5.0% See table 10% max. GENERAL SPECIFICATIONS ±250mV max. dev., 1ms recovery to 1% ±0.02%/°C 6.25V ±0.75V 90W Pin max. 50W Pout min. Continuous with auto-restart Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards Case material 110VAC 230VAC 110VAC and 230VAC Input/output Input/chassis Variable 12ms 110ms 70% typical 3000VAC 1500VAC 20kHz to 70kHz VDE0805, EN60950 IEC950, IEC1010, UL1950 BABT, CSA C22.2 No. 950 ABS plastic UL94V-0 800g (28oz) MIL-HDBK-217E 100,000 hours min. Radiated emissions EN55022, EN55011, FCC Conducted emissions EN55022, EN55011, FCC Electrostatic discharge EN61000-4-2 Electrostat. air discharge IEC801-2 RF field susceptibility IEC801-3 Electrical fast EN61000-4-4 transients/bursts Surge susceptibility EN61000-4-5 Level B Level A Level 4 Level 3 Level 3 Level 3 Level 3 Single outputs Multi's: +5.1V output Multi's: aux. outputs Single outputs Multi's: +5.1V output, Multi's: aux. outputs At turn-on +5.1V output (50% FL to 100% FL step) Temperature coefficient All outputs Overvoltage protection Output power limit Short Circuit Protection INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current Safety ground leakage current 110VAC 230VAC 110VAC, 60Hz 230VAC, 50Hz Note 1 +5.1V output only Primary power limited 85 to 264VAC Material flammability 47 to 440Hz Weight 12A max. 30A max. 0.2mA 0.4mA MTBF ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating 0°C to +40°C Non-operating –40°C to +85°C 0°C to 40°C ambient 40W Peak (0°C to 40°C, max. 60s) 50W Non-condensing Operating Non-operating 5% to 95% RH 10,000 feet max. 40,000 feet max. 2.4G rms (approx) Relative humidity Altitude Vibration, 5Hz to 500Hz See Note 8 PAGE 1 AC/DC POWER SUPPLIES | 40W AC/DC 40 Watt AC/DC external power supplies OUTPUT VOLTAGE +5.1V (A) +12.0V (B) –12.0V +5.1V (A) +15.0V (B) –15.0V +5.1V +12.0V +13.5V +15.0V +16.5V +24.0V Notes 1 For 230VAC operation a minimum output load of 4 Watts is required. 2 Natural convection cooling, 40W maximum. 3 Peak output current lasting less than 60 seconds with duty cycle less than 10%. During peak loading outputs may go outside of regulation limits. Peak total power must not exceed 50W. 4 Figures are peak-to-peak. Output noise is measured across a 20MHz bandwidth using a 12” twisted pair terminated with a 47µF capacitor. 5 Total regulation is defined as the static output regulation at 25°C, including initial tolerance, load currents within stated limits, and output voltages adjusted to their factory settings. Also, for ‘B’ output stated regulation: I(A)/I(B)
CL40-7615 价格&库存

很抱歉,暂时无法提供与“CL40-7615”相匹配的价格&库存,您可以联系我们找货

免费人工找货