CSU550AP-3

CSU550AP-3

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
CSU550AP-3 数据手册
ARTESYN CSU550AP 550 Watts Distributed Power System Advanced Energy’s Artesyn CSU550AP power supply is housed in a 1U high rack-mount enclosure measuring just 2.89 x 7.28 inches (73.5 x 185.0 mm). This form factor is significantly narrower and shorter than that of similarly rated earlier generation power supplies — freeing up valuable system space — and is achieved by use of the latest power switching technology and high density component packaging techniques. This form factor conforms to the standard market's Common Redundant Power Supplies. SPECIAL FEATURES COMPLIANCE  550 W output power  Conducted/Radiated EMI Class A  High power and short form factor  EN61000-4-11  1U power supply  High density design: 17 W/in 3 DATA SHEET Front-end Bulk Power Total Output Power: 550 W continuous Wide Input Voltage: 90 - 264 Vac; 164 - 320 Vdc SAFETY  Active Power Factor Correction  UL/cUL  EN61000-3-2 Harmonic compliance  UL + CB Report  Inrush current control  CE Mark  80plus Platinum efficiency  CCC  N+M redundant N+M ≤ 4  BSMI  Hot-pluggable  KC  Active current sharing  TÜV  Full digital control  PMBus compliant  Accurate inut power reporting  Reverse airflow option ©2021 Advanced Energy Industries, Inc. CSU550AP ELECTRICAL SPECIFICATIONS Input Input range 90 - 264 Vac; 164 - 320 Vdc Frequency 47 Hz to 63 Hz Efficiency 80plus Platinum efficiency Max input current 8.0 Arms @ 90 Vac Inrush current 10 Apk Conducted EMI Class A -6 dB Radiated EMI Class A -6 dB Power factor >0.89 beginning at 10% load ITHD 30% to 50% > 50% to 100% READ_PIN and READ_EIN ±6 W ±3% ±2% READ_IOUT ±0.4 A ±2% ±2% READ_TEMPERATURE ±3 °C advancedenergy.com 3 CSU550AP TIMING SPECIFICATIONS Description Tvout_rise 12 V main output voltage rise time 12 VSB output voltage rise time Min Max Unit 5.0 70 ms 25 ms Tsb_on_delay Delay from AC being applied to 12 Vsb being within regulation 1500 ms Tac_on_delay Delay from AC being applied to all output voltages being within regulation 3000 ms Tvout_holdup Time 12 VI output voltage stay within regulation after loss of AC 13 Tpwok_holdup Delay from loss of AC to de-assertion of PWOK 12 Tpson_on_delay Delay from PSON# active to output voltages within regulation limits 5 400 ms Tpson_pwok Delay from PSON# deactivate to PWOK being de-asserted 5 ms Tpwok_on Delay from output voltages within regulation limits to PWOK asserted at turn on 100 500 Tpwok_off Delay from PWOK de-asserted to output voltages dropping out of regulation limits Tpwok_low Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON signal 100 Tsb_vout Delay from 12VSB being in regulation to O/Ps being in regulation at AC turn on 50 T12VSB_holdup Time the 12VSB output voltage stays within regulation after loss of AC 70 TIMING DIAGRAM 12V 4 advancedenergy.com 1 ms ms 1 ms ms ms 1000 ms ms CSU550AP ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 to 50 °C, the maximum operating temperature (50 °C) is to be derated by 1 °C per 300 m above 2000 m Operating altitude up to 5000 m Operating humidity +5% to +85% non-condensing Storage temperature -40 °C to +70 °C, non-condensing Storage humidity +5% to +95% non-condensing Non-operating altitude up to 15,200 meters Vibration and shock Standard operating/non-operating random shock and vibration RoHS compliance Yes MTBF 250,000 hours per Telcordia Issue 2, Method 1, Case 3 at 25 °C ambient at full load MECHANICAL OUTLINE advancedenergy.com 5 CSU550AP POWER SUPPLY OUTPUT CARD EDGE CONNECTOR DEFINITIONS Output connector part number Card-edge Mating connector part number 2x25 pin configuration of the FCI power card connector 10035388-102LF Output Connector Pin Configuration Pin Name Pin Name A1-A9 GND B1-B9 GND A10-A18 +12 V B10-B18 +12 V A19 SDA B19 A0 (SMBus address) A20 SCL B20 A1 (SMBus address) A21 PSON B21 12 VSB A22 SMBAlert# B22 CR_BUS# A23 -VSENSE B23 12 V load share A24 +VSENSE B24 Present A25 PWOK B25 Reserved Note: PSON connect to GND for power up. ORDERING INFORMATION Model number Airflow Nominal Output Voltage Set Point Regulation Band Minimum Current Maximum Current Output Ripple P/P Standby CSU550AP-3 Normal fan 12.0 Vdc 11.9 - 12.1 Vdc 11.4 - 12.6 Vdc 0A 45 A 120 mV 12.0 V @ 2.5 A CSU550AP-3-001 Reverse fan 12.0 Vdc 11.9 - 12.1 Vdc 11.4 - 12.6 Vdc 0A 45 A 120 mV 12.0 V @ 2.5 A 6 advancedenergy.com ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-CSU550AP-235-01 2.19
CSU550AP-3 价格&库存

很抱歉,暂时无法提供与“CSU550AP-3”相匹配的价格&库存,您可以联系我们找货

免费人工找货