Embedded Power for
Business-Critical Continuity
Rev.02.23.10_64
EXB50 Series
1 of 4
EXB50 Series
Single output
Total Power: 20-50W
Input Voltage: 36-75VDC
# of Outputs: Single
Special Features
• High efficiency topology, 91%
typical on EXB50-48S05J
• Industry standard footprint
• Wide operating temperature
-40 °C to +70 °C
(natural convection)
• 60% to 110% output trim
• No minimum load
• Overvoltage and
overtemperature protection
• Remote sense compensation
• Remote ON/OFF
• Available RoHS compliant
• 2 year warranty
Safety
UL/cUL CAN/CSA 22.2
No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service.
Certificate No.
B 03 08 38572 036
Electrical Specifications
Output
Voltage adjustability:
60% to 110%
Setpoint accuracy:
± 1.5%
Line regulation:
Low line to high line
0.1% max.
Load regulation:
Full load to min. load
0.2% max.
Total error band:
± 3.0%
Minimum load:
0%
Overshoot:
At turn-on and turn-off
Undershoot:
None
None
Ripple and noise:
(see Note 1)
5 Hz to 20 MHz
100 mV pk-pk
20 mV rms
Transient response:
(See Notes 2 and 8)
48 V models
2.0% peak deviation, 200 µs recovery
to within total error band
Remote sense:
(See Note 9)
10% o/p voltage change
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Embedded Power for
Business-Critical Continuity
Rev.02.23.10_64
EXB50 Series
2 of 4
Electrical Specifications cont.
Input
Input voltage range:
(See Note 14)
48 V nominal
100 V 100 ms transient
36 - 75 Vdc
Input current:
48 V no load
48 V Remote OFF
60 mA max.
10 mA max.
Input current (max)
(See Note 4)
Input reflected ripple:
(See Note 6)
Remote ON/Off
Logic compatibility
ON
OFF
48 V models
1.7 A max. @ Io max. and Vin = 36 - 75 Vdc
48 V models
50 mA (pk-pk) typ.
Undervoltage lockout:
48 V Power up
48 V Power down
33.2 V max.
30.9 V min.
Start-up time:
(see Note 7)
Power up
Remote ON/OFF
30 ms
25 ms
Conducted emissions:
EN55022 (See Note 3)
EN55022 (See Note 3)
Level A
Level B
Radiated emissions:
EN55022
Level A
Immunity:
(See Note 13)
ESD air:
EN61000-4-2 8 kV (NP), 15 kV (RP)
ESD contact:
EN61000-4-2 6 kV (NP), 8 kV (RP)
Radiated field enclosure:
EN61000-4-3 10 V/m (NP)
Conducted (DC power):
EN61000-4-6 10 V/m (NP)
Conducted (signal)
EN61000-4-6 10 V/m (NP)
(See Note 15)
Open collector ref to -Input
Open circuit or > 2 Vdc
< 1.2 Vdc
EMC Characteristics
General Specifications
Efficiency:
See table
Basic insulation:
Input/output
1500 Vdc
Switching frequency:
Fixed
300 kHz typ.
Approvals & Standards:
(See Note 5)
IEC60950/EN60950, UL/cUL1950, CSA C22.2 No. 950
Material flammability:
UL94V-0
Weight:
50 g (1.77 oz)
MTBF:
MIL-HDBK-217F @ 25 °C
100% load ground benign
270,000 hours
Operating ambient, temperature
(natural convection)
Non-operating
-40 °C to +70 °C
3,000 metres
10,000 metres
Derate max. output current by 20%
Derate max. output current by 50%
Environmental Specifications
Thermal performance:
(See Notes 11, 12)
ETS 300 019-2-3
Altitude:
(See Note 10)
-55 °C to +125 °C
Classes T3.1 to T3.5
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Embedded Power for
Business-Critical Continuity
Rev.02.23.10_64
EXB50 Series
3 of 4
Ordering Information
Output
Power (Max.)
Input
Voltage
OVP
Output
Voltage
18 W
36 - 75 Vdc
20 W
Output Currents
(Max)
Efficiency
(Typ)
(Min)
2.15 Vdc
1.8 V
36 - 75 Vdc
2.45 Vdc
25 W
36 - 75 Vdc
33 W
Regulation
Model Numbers (16,17)
Line
Load
0A
10 A
85.7%
± 0.1%
± 0.2%
EXB50-48S1V8J (15)
2V
0A
10 A
87.5%
± 0.1%
± 0.2%
EXB50-48S2V0J (15)
2.95 Vdc
2.5 V
0A
10 A
87.5%
± 0.1%
± 0.2%
EXB50-48S2V5J (15)
36 - 75 Vdc
4 Vdc
3.3 V
0A
10 A
90.0%
± 0.1%
± 0.2%
EXB50-48S3V3J (14, 15)
50 W
36 - 75 Vdc
6.15 Vdc
5V
0A
10 A
91.0%
± 0.1%
± 0.2%
EXB50-48S05J (15)
50 W
36 - 75 Vdc
14.2 Vdc
12 V
0A
4.2 A
90.0%
± 0.1%
± 0.2%
EXB50-48S12J (15)
Notes
1 Measured as per recommended set-up. 150 mV pk-pk for EXB50-48S12J.
2 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo
max. and 0.75 lo max. to 0.5 lo max.
3 The EXB50 meets level A and level B conducted emissions only with external
components connected before the input pins to the converter.
4 Recommended input fusing is 3.15 A HRC 200 V rated fuse on the 48 V.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12 µH. 12 µH inductor in series with +Vin.
7 Start-up into resistive load.
8 Maximum output deviation is 10% inclusive of trim.
9 Contact factory for operation at higher altitude.
10 See Application Note 113 for derating curves.
11 Input transient (48 V) ETS300 132-2 ETR283.
12 100 V, 100 ms transient applies to the EXB50-48S3V3J models. Please add
the suffix ‘R03’ to the model number e.g. EXB50-48S3V3R03J. This is also
active low remote ON/OFF.
13 Active low remote ON/OFF available. Please add suffix ‘-R’ to model number
e.g. EXB50-48S3V3-RJ.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com to find a suitable alternative.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Protection
Short-circuit
Continuous
Overvoltage
Non-latching clamp
Thermal
120 °C hot spot temperature with automatic recovery
Telecom Specification
Central office Interface A
ETS300-132-2, Input voltage and current requirements
External Output Trimming
Output can be externally trimmed by using the method shown below.
+ Sense
TRIM
UP
Trim
TRIM
DOWN
- Sense
RT1
or
RT2
Embedded Power for
Business-Critical Continuity
7
6
1.40
(35.56)
BOTTOM
VIEW
2.40±0.02
(60.96±0.5)
3
Asia (HK)
1.00
(25.40)
8
0.70
(17.78)
0.40
(10.16)
9
1.00
(25.40)
1.40
(35.56)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
STAND-OFFS
4 PLACES
1
2.00
(50.80)
Europe (UK)
Ø0.079
±0.002
(Ø2.03±0.05)
0.50
(12.70)
0.20
(5.08)
Ø0.040±0.02
(Ø1.02±0.05)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
0.16±0.02
(4.10±0.5)
0.43±0.02
(10.90
±0.5)
OPEN-FRAME
HEIGHT
0.02
(0.50)
0.138±0.02
(3.50±0.5)
Americas
Rev.02.23.10_64
EXB50 Series
4 of 4
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
4
5
techsupport.embeddedpower
@emerson.com
1.90
(48.26)
0.19
(4.83)
2.28±0.02
(57.91±0.5)
ALL DIMENSIONS IN INCHES (mm)
General Tolerance
±0.010 (0.25)
Unless Otherwise Specified
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Pin Connections
Connectivity
DC Power
Pin Number
Function
Pin 1
-Vin
Pin 2
No Pin
Pin 3
Remote ON/OFF
Pin 4
+Vin
Pin 5
+Vout
Power Switching & Controls
Pin 6
+Sense
Precision Cooling
Racks & Integrated Cabinets
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Pin 7
Trim
Pin 8
-Sense
Services
Pin 9
-Vout
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.