0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
IVS1-5I0-2I0-60-A

IVS1-5I0-2I0-60-A

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

    -

  • 描述:

    IVSCONFIGURABLEPOWERSUPPLY

  • 数据手册
  • 价格&库存
IVS1-5I0-2I0-60-A 数据手册
POWER Intelligent VS Power Up to 4920 Watts Data Sheet Total Power: Up to 4920 W Input Voltage: 85 - 264 Vac 380, 440 Vac 120 - 300 Vdc 1-Phase 3-Phase # of Outputs: Up to 24 TM Font: Minion Bold for VS Minion italic for i ; size for each is the same Created on Mac Special features ƒƒ Full medical EN60601 approval* ƒƒ Intelligent I2C control ƒƒ Voltage adjustment on all outputs (manual or I2C) ƒƒ Configurable input and output OK signals and indicators ƒƒ Configurable inhibit/enable ƒƒ Configurable output UP/DOWN sequencing ƒƒ High power density (12 W/cu-in) ƒƒ Intelligent fan (speed control/fault status) ƒƒ uP controlled PFC input with active Inrush protection ƒƒ I2C monitor of voltage, current, and temperature ƒƒ Programmable voltage, current limit, inhibit/enable through I2C ƒƒ Optional extended hold-up module (SEMI F47 compliance) ƒƒ Increased power density to 150% ƒƒ Optional conformal coating ƒƒ Industrial temp range (-40 ºC to 70 ºC) ƒƒ Uses standard iMP modules ƒƒ Field upgradeable firmware ƒƒ RoHS compliant SAFETY ƒƒ UL UL60950/UL2601 ƒƒ CSA CSA22.2 No. 234 Level 5 ƒƒ UV EN60950/EN60601-1 ƒƒ BABT Compliance to EN60950/ EN60601 BS7002 ƒƒ CB Certificate and report ƒƒ CE Mark to LVD * Note: iVS8H does not have Medical or MOPP approvals. Electrical Specifications Input Input ra­nge iVS1 & iVS3 90 - 264 Vac 1Ø; 120 - 300 Vdc iVS6 & iVS8 170 - 264 Vac 3Ø iVS8H 396 - 480 Vac rated at 4920 W DC output 3Ø 342 - 480 Vac rated at 4200 W DC output 3Ø Frequency 47 - 440 Hz Inrush current 40 A peak maximum (soft start) Efficiency Up to 85% @ full case load Power Factor 0.99 typ. meets EN61000-3-2 Turn-on time AC on 1.5 sec typical, inhibit/enable 150ms typical Programmable; 50 ms internal turn-on delay (Dual Output only) EMI Filter CISPR 22/EN55022 Level “B”. Level “A” for iVS8H Leakage current 500 µA max. @ 240 Vac; 47-63 Hz Radiated EMI CISPR 22/EN55022 Level “B”. Level “A” for iVS8H Holdover storage 10 ms minimum (independent of input Vac) additional 20 mSEC holdover storage with optional HUP module (SEMI F47 compatible) AC OK > 5 ms early warning minutes before outputs lose regulation Full cycle ride thru (50 Hz). Programmable Harmonic distortion Meets EN61000-3-2 Isolation Meets EN60950 and EN60601 Meets 1 MOPP Primary to ground, 2 MOPP Primary to Secondary* Global inhibit / enable TTL, Logic “1” and Logic “0”; configurable Warranty 3 years Color: "i" 100% Blue, 50% Magenta, 0% Yellow, 0% Black "VS" - 100% Black i VS Data Sheet Electrical Specifications Output Adjustment range* ± 10% minimum all outputs (manual) (full module adjustment range using I2C) Factory set point accuracy 1% I C output program accuracy ± 5% Margining ± 4 - 6% nominal analog (single output module only) Overall regulation 0.4% or 20 mV max. (1500 W modules 1% max.) Ripple RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz Dynamic response < 2% or 100 mV, with 25% load step Recovery time To within 1% in < 300 µsec Overcurrent protection** Configurable through I2C (calibration required). Single output module and main output of the dual output module 105 - 120% of rated output current. Aux output of dual output module 105 - 140% of rated output current. Special programmable OCP delay on 1500 W module from 100 mSec to 25.5 seconds with shutdown features. Short-circuit protection Protected for continuous short-circuit. Recovery is automatic upon removal of short (Shutdown mode on 1500 W module). Overvoltage protection* Configurable through I2C 2 Single output module: 2 - 5.5 V 122 - 134%; 6 - 60 V 110 - 120% Dual output module: 2 - 6 V 122 - 134%; 8 - 28 V 110 - 120% Triple output module: 110 - 120% of highest voltage rating Thermal protection* Configurable through I2C All outputs disabled when internal temp exceeds safe operating range. > 5 ms warning (AC OK signal) before shutdown Remote sense Up to 0.5 V total drop (not available on triple output module) Single wire parallel Current share to within 2% of total rated current DC OK* ± 5% of nominal. Configurable through I2C Minimum load Not required Housekeeping bias voltage 5 Vdc @1.0 A max. present whenever AC input is applied Overall Regulation: ± 5% Ripple and Noise: 150 mV pk-pk, Bandwidth limited to 150 MHz and measured with 10 uF Tantalum capacitor and 0.1 uF ceramic capacitor in parallel on the output. Module inhibit* Configured and controlled through I2C Output/Output isolation > 1 Megohm, 500 V * Can be controlled via I C ** Controlled via I2C but requires load calibration (except 1500 W module) 2 Environmental Specifications Operating temperature -40 ° to 70 °C ambient. Derate each output 2.5% per degree from 50 ° to 70 °C. (-20 °C start up) Storage temperature -40 °C to +85 °C Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTTF field demonstrated > 550,000 hours at full load, 220 Vac and 25 °C ambient conditions i VS Data Sheet Output Module Line-up 1 2 3 5 4 — Module Type Single Single Single Single Dual Triple Max output power 210 W 360 W 750 W 1500 W 144 W 36 W Max output current 35 A 60 A 150 A 300 A 10 A 2A 2 - 60 V 2 - 60 V 2 - 60 V 2 - 60 V 8 - 15*, 24 - 28; 8 - 15*, 8 - 15*; 8 - 15*, 2 - 6; 2 - 6, 2 - 6; 24 - 28, 24 - 28; 24 - 28, 2 - 6 8 - 15, 8 - 15, 2 - 6; 8 - 15, 8 - 15, 8 - 15; 8 - 15, 8 - 15, 18 - 28; 8 - 15, 18 - 28, 2 - 6 Module Code Output voltages available* Standard voltage increments 25 25 25 25 Remote sense Yes Yes Yes Yes 16 Yes 18 Yes No Remote margin Yes Yes Yes Yes No No No V-Program - I2C Control Yes Yes Yes Yes Yes Yes No Active Current Share Yes Yes Yes Yes Yes No No Module Inhibit - I C Control Yes Yes Yes Yes Yes Yes Yes Module Inhibit - Analog Yes Yes Yes Yes Yes No No Overvoltage/Overcurrent protection Yes Yes Yes Yes Yes Yes Yes Minimum load required No No No No No No No 1 2 3 4 2 Slots occupied in any iVS case 1 1 * Note: Contact Factory for extended range down to 6 V Internal Part Number Reference Table Part # Where X = Description Module Code 73-558-XXXXi 0005, 0006, 0012, 0024, 0048, 04XX iVS/iMP 1500 W Module 5A0 - 5Z0 Single Dual 210 W 360 W 750 W 1500 W (2.0 - 8.0 V) 144 W 1500 W (10 - 60 V) Triple 36 W 1500 W with Bus Bar Adaptor Option (used with the 10 - 60 V module) i VS Data Sheet Output Module Voltage/Current* Voltage Voltage Code Single Output Module Code Dual Output*** Triple Output 1 2 3 5 4 4 - - - I2C Adjustment Ranges**** 2V A 35 A 60 A 150 A 300 A 10 A 10 A — — 2A 1.8 - 2.2 2.2 V B 35 A 60 A 150 A 300 A 10 A 10 A — — 2A 2.0 - 2.4 3V C 35 A 60 A 150 A 300 A 10 A 10 A — — 2A 2.7 - 3.3 3.3 V D 35 A 60 A 150 A 300 A 10 A 10 A — — 2A 3.0 - 3.6 5V E 35 A 60 A 150 A 300 A 10 A 10 A — — 2A 4.5 - 5.5 5.2 V F 35 A 60 A 144 A 288 A 10 A 10 A — — 2A 4.7 - 5.7 5.5 V G 34 A 58 A 136 A 273 A 10 A 10 A — — 2A 5.0 - 6.1 6.0 V H 23 A 42 A 97.5 A 250 A 10 A* 10 A* — — 2A 5.4 - 6.6 8.0 V I 20 A 36 A 84.4 A 187.5 A 10 A 4A 1A 1A 1A 7.2 - 8.8 10 V J 18 A 32 A 75 A 140 A 10 A 4A 1A 1A 1A 9.0 - 11.0 11 V K 17 A 31 A 68 A 136.3 A 10 A 4A 1A 1A 1A 9.9 - 12.1 12 V L 17 A 30 A 62.5 A 125 A 10 A 4A 1A 1A 1A 10.8 - 13.2 14 V M 14 A 21 A 53.5 A 107 A 9A 4A 1A 1A 1A 12.6 - 15.4 15 V N 14 A 20 A 50 A 100 A 8A 4A 1A 1A 1A 13.5 - 16.5 18 V O 11 A 19 A 41.6 A 83.3 A — — — 0.5 A 0.5 A 16.2 - 19.8 20 V P 10.5 A 18 A 37.5 A 75 A — — — 0.5 A 0.5 A 18.0 - 22.0 24 V Q 8.5 A 15 A 30 A 62.5 A 4A 2A — 0.5 A 0.5 A 21.6 - 26.4 28 V R 6.7 A 11 A 26.8 A 53.5 A 3A 2A — 0.5 A 0.5 A 25.2 - 30.8 30 V S 6.5 A 11 A 25 A 50 A — — — — — 27.0 - 33.0 33 V T 6.2 A 10.9 A 22.7 A 35.8 A — — — — — 29.7 - 36.3 36 V U 5.8 A 10 A 20.8 A 35.8 A — — — — — 32.4 - 39.6 42 V V 4.2 A 7.5 A 16 A 35.7 A — — — — — 37.8 - 46.2 48 V W 4.0 A 7.5 A 15.6 A 31.2 A — — — — — 43.2 - 52.8 54 V X 3.7 A 6.0 A 13.9 A 27.7 A — — — — — 48.6 - 59.4 60 V Y 3.5 A 6.0 A 12.5 A 25 A — — — — — 54.0 - 66.0 Special* Z 35 A 60 A 150 A 300 A — 10 A 2.3 - 2.6 Special* Z 35 A 60 A 150 A 300 A — 10 A 3.7 - 4.4 Special* Z 20 A 36 A 80 A 140 A — 8A 6.7 - 7.1 Contact Factory * Note: Contact Factory for extended range down to 6 V. ** Increments of current not shown can be achieved by paralleling modules (add currents of each module selected). *** Total output power on dual model must not exceed 144 W. **** For single output modules only. Green reference lines indicate physical module groupings Ordering Information Sample below is 3210 W case with 12 V @ 125 A; 24 V @ 8.5 A; 5 V @ 60 A; 12 V @ 10 A and 12 V @ 4 A; with no options. Case Size Module/Voltage/Option Codes First - Module Code Second - Voltage Code Third - Option Code iVS1   - 5L1 - 1Q1 - 2EO - 4LL0   - Case Size (mm) 1-Phase Input 1 = 5” x 5” x 11”; 1500 W - 3210 W, 9 Slots (127 x 127 x 279.4 mm) 3 = 5” x 8” x 11”; 1800 W - 4500 W, 14 Slots (127 x 203.2 x 279.4 mm) 3-Phase Input 6 = 5” x 5” x 11”; 3120 W, 9 Slots (127 x 127 x 279.4) 8, 8H = 5” x 8” x 11”; 4920 W, 14 Slots (127 x 203.2 x 279.4 mm) Module Codes: (None) = 36 W triple O/P (1 slot) 1 = 210 W single O/P (1 slot) 2 = 360 W single O/P (2 slot) 3 = 750 W single O/P (3 slot) 5 = 1500 W single O/P (slot 4) 4 = 144 W dual O/P (1 slot) HUP = Extra 30mS hold-up (1 slot) Voltage Codes: See Output Module Voltage/Current table Option Codes: 0 = Standard 1 = Module enable 2 = Constant current 3 = 1 & 2 combined 4 = Set for use in standard (non-intelligent case) 5 = Shutdown mode for 1500 W 6 = 1 & 5 combined 7-9 Future Ordering Note: 1. USB to I2C module order code 73-769-001 Software Code Case Option Codes 00 First Digit 0 - 9, A - Z Parallel code (See parallel codes table below) Second Digit 0 = No options 1 = Reverse air 2 = Not used 3 = Global enable 4 = Fan Idle w/inhibit 5 = Opt 1 + Opt 3 6 = Opt 1 + Opt 4 7 = Opt 3 + Opt 4 8 = Opt 1 + 3 + 4 9 = RS485 73-544-001 B = USB 73-546-001 C=9+3 D = CANBUS 73-544-004 E=D+3 F = RS485 - MODBUS 73-544-005  - A Software code used for configuration change. “A” is standard Hardware Code   - ### Factory assembled for hardware of firmware mods. i VS Data Sheet Ordering Information Parallel Code Slot No. 1 1&2 iVS1, 6 Diagram AC 9 8 7 6 210 210; 210 144; 144 144 2&3 AC 9 8 7 6 360 360; 360 210; 360 144; + above 5 4 3 2 1 3 3&4 AC 9 8 7 6 5 4 3 2 1 4 4&5 AC 9 8 7 6 5 4 3 2 1 5 3, 4, & 5 AC 9 8 7 6 5 4 3 2 1 6 iVS1,6: 4 & 6 AC 9 8 7 6 Diagram AC 14 13 12 11 10 9 Possible Configurations 210 210; 210 144; 144 144 8 7 6 5 4 3 2 1 5 4 3 2 1 2 iVS3, 8H Possible Configurations AC 14 13 12 11 10 9 360 360; 360 210; 360 144; + above 8 7 6 5 4 3 2 1 750 360; 750 210; 750 144; 210 210; 210 144; 144 144 1500 210; 1500 144; 210 210; 210 144; 144 144; 360 210; 360 144 750 210 210; 750 210 144; 750 144 144 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC 14 13 12 11 10 9 750 750; 750 360; 750 210; 750 144; 210 210; 210 144; 144 144 1500 1500; 1500 750; 1500 360; 1500 210; 1500 144; 210 210; 210 144; 144 144; 360 360; 360 210; 360 144 750 210 210; 750 210 144; 750 144 144 8 7 6 5 4 3 2 1 1500 1500; 1500 750 5 4 3 2 1 7 4, 5, & 6 AC 9 8 7 6 5 4 3 2 1 8 9 A C E F G iVS1, 6: 3 & 6 iVS3,8: 4, 5, & 9 AC 9 8 7 6 iVS1,6: 1 & 6 iVS3, 8: 4, 5 & 9; 12 & 13 AC 9 8 7 6 iVS1,6: 3 & 4; 8 & 9 iVS3, 8: 4 & 5; 11 & 12 AC 9 8 7 6 iVS1,6: 3, 4 & 6 iVS3, 8: 6 & 7; 3, 4, 11 & 12 AC 9 8 7 6 iVS1,6: 3, 4, 6; 8 & 9 iVS3, 8: 3, 4, 11, & 12 AC 9 8 7 6 iVS1,6: 7-8 iVS3, 8: 3 & 4; 11 & 12 AC 9 8 7 6 iVS3, 8: 3,4 & 9 1500 210 210; 1500 210 144; 1500 144 144; 1500 210 1500 750 750 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 5 4 3 2 1 1500 1500; 1500 360; 1500 144 5 4 3 2 1 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 750 210 & 750 210 5 4 3 2 1 1500 210 210; 1500 210 144; 1500 144 144 AC 14 13 12 11 10 9 1500 1500 1500; 1500 1500 750; 1500 1500 360; 1500 1500 210; 1500 1500 144 1500 1500 1500 360; 1500 1500 1500 210; 1500 1500 1500 144 1500 1500 & 750 750 8 7 6 5 4 3 2 1 750, 360, 750 AC 14 13 12 11 10 9 750 750 360 750 750 8 7 6 5 4 3 2 1 5 4 3 2 1 750, 360, 750, 210 AC 14 13 12 11 10 9 750 750 750 750 8 7 6 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 360, 360 AC 14 13 12 11 10 9 750 360 & 750 210; 750 750 & 750 750 8 7 6 5 4 3 2 1 AC 14 13 12 11 10 9 750 750 750 8 7 6 5 4 3 2 1 H iVS3, 8: 11 & 12 AC 14 13 12 11 10 9 750 750 8 7 6 5 4 3 2 1 J iVS3, 8: 4 & 5; 9 & 10 AC 14 13 12 11 10 9 1500 210 & 210 1500 8 7 6 5 4 3 2 1 K iVS3, 8: 1 & 9; 5 & 12 AC 14 13 12 11 10 9 1500 750 & 1500 750 8 7 6 5 4 3 2 1 L iVS3, 8: 3 & 4; 7 & 8; 9 & 10 AC 14 13 12 11 10 9 750 210 & 750 210 & 210 1500 8 7 6 5 4 3 2 1 M iVS3, 8: 3, 4 & 9; 6 & 7 AC 14 13 12 11 10 9 750 750 360 750 8 7 6 5 4 3 2 1 N iVS3, 8: 4, 5 & 9; 12,13 & 14 AC 14 13 12 11 10 9 1500, 1500, 1500, 210, 210 8 7 6 5 4 3 2 1 P iVS3, 8: 1 & 9 AC 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1500, 750 i VS Data Sheet i VS Case Specifications iVS1 and iVS6 S L O T 5 S L O T 9 S L O T 8 S L O T 7 S L O T 6 S L O T 4 S L O T 3 S L O T 2 S L O T 1 Input 90 - 264 Vac iVS1 = 5” x 5” x 11” 1500 W max. (127 x 127 x 279.4 mm) 9 available slots iVS6 = 5” x 5” x 11” N/A (127 x 127 x 279.4 mm) 9 available slots 3-phase only iVS3, iVS8 and iVS8H S L O T 8 S L O T 7 Input 90 - 264 Vac S L O T 14 S L O T 13 S L O T 12 S L O T 11 S L O T 10 S L O T 9 S L O T 6 S L O T 5 S L O T 4 S L O T 3 S L O T 2 S L O T 1 iVS3 = 5” x 8” x 11” 1800 W max. (127 x 203.2 x 279.4 mm) 14 available slots N/A iVS8 = 5” x 8” x 11” (127 x 203.2 x 279.4 mm) 14 available slots N/A N iVS8H = 5” x 8” x 11” 1 (127 x 203.2 x 279.4 mm) 2 ~ 14 available slots 170 - 264 Vac 3210 W max. 170 - 264 Vac 3210 W max. 170 - 264 Vac 4500 W max. 170 - 264 Vac 4920 W max. 380 Vac 440 Vac 4920 W max. 3 Pin Connectors Figure 1. AC Input 1 2 3 N ~ 2 φ1 φ2 3 φ3 1 4 iVS6 iVS1, iVS3 Figure 1. AC Input Figure 2. Connector J1 AC Input Single Phase Pin Function 1 AC neutral Line 1 2 AC line (hot) Line 2 3 Chassis (earth) ground Not used Line 3 4 3 Phase Chassis (earth) ground 1 6 5 10 Figure 2. Connector J1 Mates with Molex 90142-0010 Housing 90119-2110 Pin Connector Kit Part No.: 70-841-004 iVS8, iVS8H Figure 3. Connector J2 10 6 5 1 Mates with Landwin 2050S1000 Housing 2053T011V Pin or JST PHDR-10VS Housing JST SPHD-002T-P0.5 (28-24) JST SPHD-001T-P0.5 (26-22) Connector Kit Part No.: 70-841-023 I2C Bus Output Connector Pin Function 1 2 3 4 5 6 7 8 9 10 No connection No connection No connection Serial clock signal (SCL) Serial data signal (SDA) Address bit 0 (A0) Address bit 1 (A1) Address bit 2 (A2) Secondary return (GND) 5 VCC external bus (5 VCC bus) PFC Input Connector (control & signals) Pin Function 1 2 3 4 5 6 7 8 9 10 Input AC OK - “emitter” Input AC OK - “collector” Global DC OK - “emitter” Global DC OK - “collector” Spare Global inhibit/optional enable logic “0” Global inhibit/optional enable logic “1” Global inhibit/optional enable return +5 VSB housekeeping +5 VSB housekeeping return i VS Data Sheet Mechanical Drawings iMP Modules Single 210 Watt DC-DC Converter Output Modules .44” (11.2) 2X V+ ~ single or dual o/p single or dual o/p single or dual o/p main dual o/p, single is spare dual o/p, single is spare M4X8 SCREWS VV ADJ .44" (11.4) single or dual o/p main single o/p single o/p single or dual o/p main (12.1) Function + Remote Sense Remote Margin / V. Program Margin High - Remote Sense N / Margin Low 1 Spare 2 Module, Isolated Inhibit 3 Inhibit Return Module Current Share (SWP) + Remote Sense V2 Figure Sense 1. AC Input - Remote V2 1.38" (35.1) Pin No. 1 2 3 4 5 6 7 8 9 10 .48" Control Signal Information, J1 Control Connector DC OUTPUT CONNECTOR .32" (8.1) Single 360 Watt .63” .33” (16.0) (8.5) * Note: All iMP modules have a green DCOK LED. (except for 36 W module) .48” (12.1) (2X) Mates with Molex 90142-0010 Housing 90119-2110 Pin VPIN 1 V ADJ .44” (11.4) 5 10 1 6 V+ M 4 X 8 SCREWS WITH CONICAL WASHER 1.38” (35.2) (2X) Figure 4. Connector J1 PIN 1 Figure 2. Connector J1 DC OUTPUT CONNECTOR .32” (8.1) Single 750 Watt Single 1500 Watt 10-60 V Single 1500 Watt 2-8 V .63" (16.0) V+ 59.3 ± 0.2 .59" (15.0) (3x) 31.6 ±0.8 03/24/2008 11.3 ±0.8 (2x) 15.0 ±0.8 DC OUTPUT CONNECTOR (2x) 16.0 ±0.2 PIN 1 (2x) 16.0 ±0.2 For Factory-Use Only .44" (11.0) 1.24"(31.5) (2X) .61"(15.6) (2X) 8.1 ±0.8 M4X8 SCREWS W/ CONICAL WASHER (6X) VADJ V- .32" (8.1) PIN 1 V ADJ M4X8 SCREWS (4X) DC OUTPUT CONNECTOR V- V+ Dual 144 Watt Triple 36 Watt .46 (11.7) V1 + (4X) V1 - V1 + V1 - V2 + V2 + V2 - V2 - .30 (7.5)(3X) M3X8 SCREWS WITH SPRING WASHER (4X) 1.17 (29.7) .42 (10.7) .32 (8.1) V2 ADJ V1 ADJ PIN 1 V3 + V3 - Mates with Molex 09-91-0600 Housing 26-60-5060 Pin i VS Data Sheet i VS Series iVS1 (1500/3210 Watts Max) 5-Inch Case Size: iVS1: 5” x 5” x 11” (127 mm x 127 mm x 279.4 mm) Weight: iVS1 Case: 6.2 lbs. • 1500 W Single: 2.0 lbs. • 750 W Single: 1.6 lbs. • 360 W Single: 1.0 lb. • 210 W Single: 0.6 lb. • 144 W Dual: 0.6 lb. REVERSE AIRFLOW DIRECTION NORMAL AIRFLOW DIRECTION 127.0 ± 0.5 B B A 279.40 ± 1.27 127.0 ± 0.5 63.5 AC INPUT CONNECTOR FAN 92 X 92 X 38 mm L N PE 127.0 ± 0.9 127.0 ± 0.9 101.6 ± 0.9 C USB PROGRAMMING CONNECTOR OPTION 65.5 SELV CONTROL CONNECTOR I2C C CONNECTOR 12.7 OUTPUT MODULE AREA 19.1 171.5 M4 MTG HOLES 4 PL 11.6 AC OK LED DC OK LED 13.5 33.5 12.0 57.4 “MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES” 171.45 29.05 5.00 12.70 B 114.30 22.80 19.05 171.45 A Notes: 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375” centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. (J2) 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.155” (4.0 mm). Max. torque: 5 in-lbs. (0.57 N-m). 6. Output module connections: All single O/P modules are M4 x 8 mm screws. Max. torque: 10 in-lbs. (1.13 N-m). Dual O/P module is M3 x 8 mm screws. Max. torque: 5 in-lbs. (0.57 N-m). C i VS Data Sheet i VS Series iVS3 (1800/4500 Watts Max) 8-Inch Case Size: iVS3: 5” x 8” x 11” (127 mm x 203.2 mm x 279.4 mm) Weight: iVS3 Case: 9.0 lbs. • 1500 W Single 2.0 lbs.• 750 W Single: 1.6 lbs. • 360 W Single: 1.0 lb. • 210 W Single: 0.6 lb. •144 W Dual: 0.6 lb. REVERSE AIRFLOW DIRECTION NORMAL AIRFLOW DIRECTION B 203.2±0.5 279.4±1.27 52.6 A 12.7 USB PROGRAMMING CONNECTOR OPTION I2C 1 3 SL O T 2 T O SL T T O SL O SL T O SL 4 5 7 6 T O SL 8 T T O O SL 171.45 A 11.6 SELV CONTROL CONNECTOR C C DC OK LED 42 M4 MTG HOLES 4 PL AC OK LED 61.2 19.1 81.5 29.1 #8-32 MTG HOLES 5PL MARKED “A” 6, 7 REF 171.5 B A B A B A B B A 177.8 149.4 173.3 12.7 14.4 “MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES B A 16.2 19.1 171.5 M4 MTG HOLES 5 PL MARKED “B” A Notes: 1. Input: Barrier type. Three M4 screws (0.512” centers). Max torque: 7 in-lbs. (0.79 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. (J2) 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.155” (4.0 mm). Max. torque: 5 in-lbs. (0.57 N-m). 6. Output module connections: All single O/P modules are M4 x 8 mm screws. Max. torque: 10 in-lbs. (1.13 N-m). Dual O/P module is M3 x 8 mm screws. Max. torque: 5 in-lbs. (0.57 N-m). 65.5 127±0.9 101.6 ± 0.9 SL OUTPUT MODULE AREA SL FAN 80 X 80 X 38mm O T 9 11 10 O O SL SL 98 A T T 12 T O SL SL SL O O T AC INPUT CONNECTOR T 14 13 B C i VS Data Sheet i VS Series iVS6 (3210 Watts Max) 5-Inch Case Size: iVS6: 5” x 5” x 11” (127 mm x 127 mm x 279.4 mm) Weight: iVS6 Case: 6.0 lbs. • 1500 W Single 2.0 lbs. • 750 W Single: 1.6 lbs. • 360 W Single: 1.0 lb. • 210 W Single: 0.6 lb. • 144 W Dual: 0.6 lb. 279.4±1.0 5.0±0.5 NORMAL AIRFLOW DIRECTION REVERSE AIRFLOW DIRECTION 293.0±1.2 57.4 171.5 (2X) SLOT 7 SLOT 9 SLOT 6 101.6±0.9 (2X) SLOT 1 SLOT 3 SLOT 2 12.7 (2X) 171.5 (2X) SLOT 4 12.7 (2X) FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) 19.1 (2X) 171.5 (2X) 19.1 (2X) 12.0 19.1 (2X) 12.7 (4X) 33.5 DC OK LED 11.6 (2X) SELV CONTROL CONNECTOR 13.5 SLOT 5 101.6±0.9 (2X) 65.5 127.0±0.9 AC OK LED I2C CONNEC- L1 L2 L3 L1 L2 L3 INTERNAL FUSES 15A/250V USB PROGRAMMING CONNECTOR 12.6±0.6 AC INPUT CONNECTOR SLOT 8 GND 20.3±0.6 127.0±0.5 63.5 12.7 (4X) FOR #8-32 SCREW (4X) (SYSTEM MOUNTING) FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) 171.5 (2X) 29.1 (2X) Notes: 1. Input: Barrier type. Four M3 screws (0.325” centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. (J2) 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.155” (4.0 mm). Max. torque: 5 in-lbs. (0.57 N-m). 6. Output module connections: All single O/P modules are M4 x 8 mm screws. Max. torque: 10 in-lbs. (1.13 N-m). Dual O/P module is M3 x 8 mm screws. Max. torque: 5 in-lbs. (0.57 N-m). FOR M4 SCREW (4X) (FOR SYSTEM MOUNTING) i VS Data Sheet i VS Series iVS8 (4920 Watts Max) iVS8H (4920 Watts Max) 8-Inch Case Size: iVS8: 5” x 8” x 11” (127 mm x 203.2 mm x 279.4 mm) Weight: iVS8 Case: 9.0 lbs. • 1500 W Single 2.0 lbs. • 750 W Single: 1.6 lbs. • 360 W Single: 1.0 lb. • 210 W Single: 0.6 lb. • 144 W Dual: 0.6 lb. 6.8 max (2x) NORMAL AIRFLOW DIRECTION REVERSE AIRFLOW DIRECTION 291.1±1.2 279.4±0.2 USB Programming Connector Option 50.7 72.1 7 12.7 (2x) 31.8 19.1 (2x) MOSYTEM Mounting for #8-32 Screw (5X) (’a’) 19.1 (2x) 171.5 (2x) 171.5 (2x) 171.5 (2x) 19.1 (3x) 14.4 (2x) 12.7 (2x) SELV Control Connector GND Terminal 15.5 (2x) 23.9 (2x) MOSYTEM Mounting for M4 Screw (I3X) (’a’) I2C Connector 101.6±0.9 12.7 (2x) 11.6 (2x) 65.5 (2x) 127.0±0.2 AC Input Connector 101.6±0.9 12.7 (2x) 203.2±0.2 155.6 52.6 29.1 (3x) 171.5 (2x) Notes: 1. Input: Barrier type. Three M3.5 screws (0.394” centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. (J2) 10 position housing (Landwin 2051P1000T). Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins. 3. Chassis material: aluminum with chemical film coating (conductive). 4. All dimensions are in millimeters and inches, and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.155” (4.0 mm). Max. torque: 5 in-lbs. (0.57 N-m). 6. Output module connections: All single O/P modules are M4 x 8 mm screws. Max. torque: 10 in-lbs. (1.13 N-m). Dual O/P module is M3 x 8 mm screws. Max. torque: 5 in-lbs. (0.57 N-m). i VS Data Sheet Optional CANBUS or RS485 Interface The RS485/CAN-to-I2C uses 2 Input Protocols and 1 Output Protocol. Slave/Server Device(s) The Input Protocols used are RS485 using Modbus (Command Index: 0x01), and CAN using modified Modus (Command Index: 0x02). Adapter Output Protocols I2C with SMBus Support The Output Protocol use is: I2C with SMBus support (Command Index: 0x80). Adapter Protocol Adapter Command Adapter Controls Input Protocols RS485 using Modbus CAN using Modified Modbus Master/Client Device(s) RS485/CAN - to - I2C For detailed info, download the Software Requirements Specification (SRS) from http://www.artesyn.com/ power/power-supplies/category.php?catID=103 iVS CAN RS485 iVS I2C USB WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 South Diablo Way Suite B100 Tempe, AZ 85282, USA +1 888 412 7832 Ground Floor Offices, Barberry House 4 Harbour Buildings, Waterfront West Brierley Hill, West Midlands DY5 1LN, UK +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn Embedded Power, Artesyn, and all Artesyn related logos are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. Specifications are subject to change without notice. © 2020 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com For more information: www.artesyn.com For support: productsupport.ep@artesyn.com iVS DS 09Jun2020 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Artesyn Embedded Technologies: IVS1-5R0-00-A IVS1-5R0-5R0-60-A
IVS1-5I0-2I0-60-A 价格&库存

很抱歉,暂时无法提供与“IVS1-5I0-2I0-60-A”相匹配的价格&库存,您可以联系我们找货

免费人工找货