ARTESYN LCC250
250 Watts Convection/Conduction
Mounting
Advanced Energy's Artesyn LCC250 AC-DC power supply is a
fully-enclosed conduction cooled series delivering full useable
power at high temperatures. The LCC250 series, with IP64
protection against the ingress of dust and water, is ideal for
applications such as outdoor signage and telecom installation
like antenna and base station equipment. The power supplies
are equally suitable for indoor use, such as in control consoles,
indoor signage and desktops for medical applications, where
the absence of cooling fans can help minimize dust and noise.
SPECIAL FEATURES
SAFETY5
250 W full power at elevated
UL + CSA
temperatures
Wide operating temperature range
suited for outdoor application
IP64 rated
Conduction-cooled or convection
Differential remote sense
Output adjust
Output On/Off (Positive or Negative
logic user selectable)
COMPLIANCE
TÜV
Data Sheet
Total Power:
250 W
# of Outputs:
Single
Outputs:
12, 24, 48 V
62368-1 2nd Ed.
ANSI ES60601-1
3rd Ed
62368-1 2nd Ed.
60601-1 3rd Ed.
61347-1; 2-13
CB Scheme IEC 62368-1
IEC 60950-1 2nd Ed
IEC 61347-1; 2-13
IEC 60601-1
China CCC
CE Mark
EMI Class B
EN61000 Immunity
MIL-STD-461E: CE101; CE102;
CS101; CS114
©2020 Advanced Energy Industries, Inc.
LCC250
ELECTRICAL SPECIFICATIONS
Input
Input range
90 - 264 Vac (Operating)
115/230 Vac (Nominal)
Frequency
47 - 63 Hz
Input fusing
Internal fuse on both L and N lines
Inrush current
50 A
Power factor
> 0.92 Full load
Harmonics
Meets EN61000-3-2; MIL-STD-461E(6); CE101; CE102; CS101; CS104
Input current
3.4 A @ 90 Vac full load
Hold up time
16 ms minimum at 115 Vac; 100% load
Efficiency
230 Vac; 100% load
12 V - 89% typical
24 V - 91% typical
48 V - 91.5% typical
Leakage current
< 275 μA at 230 Vac
Output
Output rating
12 V @ 20.8 A
24 V @ 10.4 A
48 V @ 5.2 A
Set point
±0.2%
Factory set point
Total regulation range
±2%
Line/Load/Temperature
Rated load
250 W maximum
Minimum load
0 A Load
Capacitive load
0 - 330 μF/Amp
Output voltage overshoot
No loss of regulation
No overshoot/undershoot outside the regulation
band during on or off cycle
Constant output voltage adjustment range
12 V: +10 / -10%
24 V: +14.6 / -15%
48 V: +15% / -15%
Adjust via VR2
Constant output current adjustment range
+0 / -50%
Adjust via VR1
CC mode supported from Vo nominal down to 80%
Vo
Output ripple and noise
1﹪
0 to 330 μF/Amp
Transient response
±5% Vo max transient;
recovery < 500 μs max
50% Load Step @ 1 A/μs
Step Load verified at: 50% to 100% Load; 90 - 264
Vac input; Capacitive load from 0 to 330 μF/Amp
Remote sense
Capable of Stable Offset of ±0.5 Vdc at output +SENSE (Red Wire); -SENSE (Black Wire)
cable termination
Output On/Off
Remote On/Off referenced to secondary side.
Positive or Negative logic user selectable via
CN2. Factory default is Positive logic
On/Off (Orange Wire); On/Off Return (White Wire)
Overcurrent protection (OCP)
≤ 150% Io
Auto-recovery
Overvoltage protection (OVP)
110% to 135% Vo
Latching mode; Requires input AC recycle
Overtemperature protection (OTP)
Output isolation
2 advancedenergy.com
Auto-recovery; hiccup mode
3000 Vac Input to Output
1500 Vac Input to Ground
500 Vac Output to Ground
LCC250
ENVIRONMENTAL SPECIFICATIONS
Operating temperature
Suffix 4P (Conduction): -40 °C to +85 °C Baseplate Temperature
Suffix 7P (Convection): -40 °C to +85 °C Ambient Temperature
Storage temperature
-40 °C to +85 °C
Humidity
10% to 100% (Condensing & Non-Condensing)
Altitude
Operating: 13,000 feet
Non-Operating: 50,000 feet
Shock
IEC68-2-27
Vibration
IEC68-2-6 / IEC721-3-2
Ingress protection
IP64 Rated
MTBF (calculated)
> 780,000 hours at 100% load; Low line; Telcordia SR-332
ORDERING INFORMATION
Model Number
Output
Adjustment Range
Output Current
Min
Max
Output Ripple P/P1
Line/ Load Regulation
LCC250-12U-4P
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-12U-4PE
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-12U-7P
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-12U-7PE
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-24U-4P
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-24U-4PE
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-24U-7P
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-24U-7PE
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-48U-4P
48 V
±15%
0A
5.2 A
1% 4
±2%
LCC250-48U-4PE
48 V
±15%
0A
5.2 A
1% 4
±2%
LCC250-48U-7P
48 V
±15%
0A
5.2 A
1% 4
±2%
advancedenergy.com
3
LCC250
ORDERING INFORMATION (CONTINUED)
1. Output ripple measured at the end of the output cable terminated with 10 μF tantalum cap in parallel with 0.1 μF
ceramic capacitor.
2. 12 V: 1% limit is achieved with 2X 820 uF/16 V external cap (e.g. PLG1C821MDO1 from Nichicon or equivalent).
Otherwise, maximum limits are 1.5% at Ta ≥ 0 °C and 2.0% max at Ta < 0 °C.
3. 24 V: 1% limit is achieved with 2X 820 uF/35 V external cap (e.g. UPM1V821MHD1TO from Nichicon or equivalent).
Otherwise, maximum limits are 1.5% at Ta ≥ -10 °C. 2.0% max ripple at Ta < -10 °C is met with below external
capacitance:
Ambient Temperature (°C)
Recommended External Capacitors (μF)
-20
-25
-30
-35
-40
1000
2200
3300
12000
22000
4. 48 V: 1% limit is achieved with 3X 470 uF/63 V external cap. Otherwise, maximum limits are 1.5% max at Ta ≥ 0 °C
and 2% max at
Ta < 0 °C.
5. Two (2) LCC250 model numbers exist with same electrical performance except for safety approvals as shown below:
· LCC250-XXu-xPE version = Europe/USA/China safety approved & carries CE/TUV, cUL, & CCC logos
· LCC250-XXu-xP version = Europe/USA safety approved & carries CE/TÜV & cUL logos
6. 12 V unit requires external filtering for MIL-STD-461E compliance. Consult Artesyn Technical Support.
7. Warranty: 2 years
4 advancedenergy.com
LCC250
ORDERING INFORMATION (CONTINUED)
LCC250-12U-7P (Convection)
VIN = 115 Vac
25
20
15
NAT CONV
100 LFM
10
200 LFM
5
20
Output Current (A)
Output Current (A)
25
300 LFM
400 LFM
15
25
35
45
55
65
Ambient Temperature (˚C)
75
200 LFM
300 LFM
400 LFM
0
25
35
75
85
12V Efficiency vs. Input Line
95%
90%
15
Efficiency (%)
20
NAT CONV
10
100 LFM
200 LFM
5
300 LFM
25
35
85%
80%
75%
Vin = 115 Vac
70%
400 LFM
0
45
55
65
75
85
Vin = 230 Vac
65%
0%
Ambient Temperature (˚C)
20%
Fig 3. 12 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
LCC250-24U-4P (Conduction)
Output Current (A)
6
90 Vac
4
115 Vac
230 Vac
2
264 Vac
25
35
45
55
65
75
85
Baseplate Temperature (˚C)
Fig 5. 24 V “4P” Suffix (Conduction) Output Current Derating
95
100%
10
8
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
6
4
2
0
0
80%
LCC250-24U-7P (Convection)
VIN = 115 Vac
12
10
8
40%
60%
Output Load
Fig 4. 12 V Efficiency Curve
12
Output current (A)
45
55
65
Ambient Temperature (˚C)
Fig 2. 12 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
LCC250-12U-7P (Conduction)
VIN = 230 Vac
25
100 LFM
5
85
Fig 1. 12 V “4P” Suffix (Conduction) Output Current Derating
NAT CONV
10
0
Output Current (A)
LCC250-12U-7P (Convection)
VIN = 115 Vac
25
35
45
55
65
75
85
Ambient Temperature (˚C)
Fig 6. 24 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
advancedenergy.com
5
LCC250
ORDERING INFORMATION (CONTINUED)
12
95
90
10
8
Efficiency (%)
Output Current (A)
24 V Efficiency vs. Input Line
LCC250-24U-7P (Convection)
VIN = 230 Vac
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
6
4
2
85
80
75
115 Vac
70
230 Vac
65
0
25
35
45
55
65
75
0
85
20
40
Ambient Temperature (˚C)
60
80
100
Output Load (%)
Fig 7. 24 V “7P” Suffix (Convection) Output Current Derating at 230
Fig 8. 24 V Efficiency Curve
Vac
LCC250-48U-7P (Convection)
VIN = 115 Vac
LCC250-48U-4P (Conduction)
6
6
Output Current (A)
Output Current (A)
5
4
3
90 Vac
115 Vac
230 Vac
264 Vac
2
1
0
25
35
45
55
65
75
85
5
4
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
3
2
1
0
95
25
35
Baseplate Temperature (˚C)
Fig 9. 48 V “4P” Suffix (Conduction) Output Current Derating
65
75
85
48 V Efficiency vs. Input Line
95
90
5
Efficiency (%)
Output Current (A)
55
Fig 10. 48 V “7P” Suffix (Convection) Output
LCC250-48U-7P (Convection)
VIN = 230 Vac
6
45
Ambient Temperature (˚C)
4
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
3
2
1
85
80
75
Vin=115 Vac
70
Vin=230 Vac
65
0
25
35
45
55
65
Ambient Temperature (˚C)
75
85
Fig 11. 48 V “7P” Suffix (Convection) Output Current Derating at 230
Vac
6 advancedenergy.com
0
20
40
60
Output Load (%)
Fig 12. 48 V Efficiency Curve
80
100
LCC250
MECHANICAL DRAWINGS
12 V
MODEL LABEL
L1
AC INPUT
POTTING TRIM LABEL
C
A
L2
DC OUTPUT
6-Ø 3.6 ±0.10
C
C
B
B
A
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
L3
CONTROL
A
B
B
C
C
(2 - 59.7)
M
A
BUSHING
(See DETAIL C)
C
(2 - 119.4)
(2 - 119.4)
(2 - 139.7)
ADJUST DIMMING
(VR1)
ADJUST REMOTE ON/OFF
(CN2)
SEE DETAIL C
177.6 ±0.6
VIEW M
27.9 ±0.6
LCC250-12U-4P
ADJUST OUTPUT VOLTAGE
(VR2)
ON
(NEGATIVE POLARITY)
0.30
SERIAL NO. BARCODE LABEL
OFF
(POSITIVE POLARITY)
37.6 ±0.6
LCC250-12U-7P
DETAIL C
24 V / 48 V
MODEL LABEL
POTTING TRIM LABEL
L1
AC INPUT
L2
DC OUTPUT
6-Ø 3.6 ±0.10
C
A
C
C
B
B
A
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
A
B
B
C
C
(2 - 59.7)
C
L3
CONTROL
BUSHING
See DETAIL C
(2 - 119.4)
(2 - 119.4)
(2 - 139.7)
Available Mounting Holes for “-7P” Suffix
(with Heatsink)
177.6 ±0.6
Mounting Hole “A”
4X locations (Top Cover Side)
#6-23 thread
27.9 ±0.6
LCC250-xxU-4P
SERIAL NO. BARCODE LABEL
(FOR 4PE/7PE ONLY)
37.6 ±0.6
LCC250-xxU-7P
A
0.30
Mounting Hole “B”
4X locations (Top Cover Side)
M3X0.5 thread
For both “A” and “B” Mounting Holes,
screw length should be
很抱歉,暂时无法提供与“LCC250-48U-4P”相匹配的价格&库存,您可以联系我们找货