150 Watts
LPQ150 Series
Total Power: 110-150 Watts
Input Voltage: 85-132 / 170-264 VAC
220-300 VDC
# of Outputs: Quad
Electrical Specs
Input
Input range
85-132 VAC or 170-264 VAC automatically selected. 220-300 VDC
47-63 Hz
38 A max, cold start @ 25°C
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Frequency
Inrush current
Efficiency
EMI filter
Safety ground leakage
current
Special Features
•
•
•
•
•
•
•
•
•
•
•
Auto ranging input
Remote sense on main output
Remote inhibit
Single wire current sharing
Power fail
Built-in EMI filter
Low output ripple
135 khz switching frequency
Overvoltage protection
Overload protection
Adjustable floating 4th output
(On LPQ152 and LPQ153 models)
• Optional cover (-C suffix). See page 64.
Environmental
Output
Maximum power
Adjustment range
Cross regulation
Hold-up time
Overload protection
Overvoltage protection
Power failure
Remote inhibit
Electromagnetic susceptibility: designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Remote sense
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient condition
TTL logic signal goes high 50-150
msec after 5 V output. It goes low at
least 3 msec before loss of regulation
Requires an external TTL high signal to
inhibit outputs
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE
UL
CSA
NEMKO
CB
CE
114
110 W convection (75 W with cover)
150 W with 30 CFM forced air
(130 W with cover)
±5% on main; 5-25 V on 4th output
on LPQ 152 & LPQ 153
±2% on output 1; ±3% on outputs 2, 3
&4
20 ms @110 W load at nominal line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5.7-6.7 VDC on main output
Logic Control
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Storage temperature: -40° to 85°C
0.5 mA @ 50/60 Hz, 264 VAC input
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1260 (LC# 88585)
EI32002
LR53982
P95102999
2061
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 12.10.03
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPQ150 Series
Ordering Information
Model
Output
Minimum
Maximum Load with
Maximum Load with
Voltage
Load
Convection Cooling
30 CFM Forced Air
Peak
Load1
Regulation2
Number
LPQ152
5V
12 V
-12 V
±5-25 V
2A
.1 A
.1 A
0A
15 A
6A
2A
2.5 A
22 A
8A
2.5 A
3A
30 A
10 A
3A
3A
±2%
±3%
±3%
±3%
50 mV
120 mV
120 mV
240 mV, max.
LPQ153
5V
15 V
-15 V
±5-25 V
2A
.1 A
.1 A
0A
15 A
4.8 A
1.6 A
2.5 A
22 A
6.4 A
2A
3A
30 A
8A
2.4 A
3A
±2%
±3%
±3%
±3%
50 mV
150 mV
150 mV
240 mV, max.
LPQ154
5V
12 V
-12 V
24 V
2A
.1 A
.1 A
.5 A
15 A
6A
2A
3.5 A
22 A
8A
2.5 A
4.5 A
30 A
10 A
3A
5A
±2%
±3%
±3%
+10 / -5%
50 mV
120 mV
120 mV
240 mV
1.
2.
3.
4.
5.
Ripple
P/P (PARD)3
Peak current lasting
很抱歉,暂时无法提供与“LPQ154”相匹配的价格&库存,您可以联系我们找货