ARTESYN
LPS170 SERIES
175 Watts
Advanced Energy’s Artesyn LPS170 series AC-DC power
supplies are available with a nominal main output of 5 V, 12
V, 15 V or 24 V, adjustable over a wide 2:1 ratio. Auxiliary 12
V and 5 V standby outputs are also provided. Main output
remote sense and single-wire current sharing are supported
as standard. LPS170 power supplies provide 110 Watts
of output power with free air convection cooling. which
can be boosted to 175 Watts with 30 CFM of forced air. All
models have an 8.5 x 4.25 x 1.5 inch form factor and are ideal
for 1U (1.75-inch) rack installations and other low-profile
applications such as telecommunications, networking hubs
and routers, test and measurement equipment, single-board
computers and gigabit Ethernet devices.
SPECIAL FEATURES
SAFETY
Active power factor correction
VDE
IEC EN61000-3-2 compliance
UL UL60950/62368
Wide range adjustable output:
CB
Certificate and report
Remote sense on main output
CSA
CSA 22.2-234 Level 3
Single wire current sharing
CE
Mark (LVD)
Power fail and remote inhibit
NEMKO EN 60950/EMKO-TUE
Built-in EMI filter
UKCA Mark
AT A GLANCE
Total Power
100 to 175 Watts
Input Voltage
85 to 264 VAC
120 to 300 VDC
# of Outputs
Single
EN60950 (IEC60950)
Low output ripple
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
5 V standby output
12 V Aux output
Optional cover (-C suffix)
RoHS compliant
©2022 Advanced Energy Industries, Inc.
LPS170
ELECTRICAL SPECIFICATIONS
Input
Input range
85 to 264 VAC; 120 to 300 VDC
Frequency
47 to 63 Hz
Inrush current
38 A max, cold start @ 25°C
Efficiency
75% typical at full load
EMI filter
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power Factor
0.99 typical
Safety ground Leakage current
1.0 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
110 W convection (75 W with cover)
175 W with 30 CFM forced air (130 W with cover)
Adjustment range
2:1 wide ratio minimum
Standby outputs
5 V @ 2 A regulated ±5%
Hold-up time
20 ms @175 W load at nominal line
Overload protection
Short circuit protection on all outputs.
Case overload protected @ 110 to 145% above peak rating
Overvoltage protection
10% to 40% above nominal output
Aux output
12 V @ 1 A to 5 %, +10%
LOGIC CONTROL
Power failure
TTL logic signal goes high 100 to 500 msec after V1 output; It goes low at least 4 msec before loss of regulation
Remote inhibit
Requires contact closure to inhibit outputs
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
DC POWER GOOD
TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation
2 advancedenergy.com
LPS170
ENVIRONMENTAL SPECIFICATIONS
Operating temperature
0°C to 50°C ambient; derate each output at 2.5% per degree from 50°C to 70°C
Low temperature start
-20°C
Temperature coefficient
±0.4% per °C
Storage temperature
-40°C to 85°C
Electromagnetic susceptibility
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity
Operating; non-condensing 5% to 95%
Vibration
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz,
operational
MTBF demonstrated
>550,000 hours at full load and 25°C ambient conditions
ORDERING INFORMATION
Model
Number
Output Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air
Peak Load1
Regulation2
Ripple
P/P(PARD)3
LPS172
5 V (2.5 to 6 V)
0A
22 A
35 A
38 A
±2%
50 mV
LPS173
12 V (6 to 12 V)
0A
9.1 A
15 A
16.5 A
±2%
120 mV
LPS174
15 V (12 to 24 V)
0A
7.3 A
12 A
13.2 A
±2%