ARTESYN
LPS40 SERIES
40 W
Advanced Energy’s Artesyn LPS40 series of open-frame
comprises four single output models, offering voltages of 5
V, 12 V, 15 V or 24 V. Each model accepts a universal input of
85 to 264 VAC or 120 to 300 VDC. All four feature medical
safety approvals, with a very low safety ground leakage
current of less than 75 mA. These compact switch-mode
power supplies feature output overvoltage and short-circuit
protection, as well as remote sense. They provide 40 W of
output power with free air convection cooling and 55 watts
with 30 CFM of forced air. Less than 1U high, LPS40 power
supplies are designed for medical, test and measurement,
single-board computers, telecommunications and
networking applications.
SPECIAL FEATURES
SAFETY
Universal input
CUL 62368-1
3" x 5" footprint
Less than 1U high
Remote sense
Built-in EMI filter
Low output ripple
Adjustable output
Overvoltage protection
Overload protection
110 KHz switching frequency
AT A GLANCE
Total Power:
25 to 40 W
Input Voltage:
85 to 264 VAC
120 to 300 VDC
# of Outputs:
Single
E132002
CSA
CSA 22.2-234 Level 3
LR53982C
NEMKO EN 62368-1/EMKO-TUE
CB
P94100375 (74-sec) 203
Certificate and report
1119, 1125, 1126, 1127
CE Mark
UKCA Mark
LPX40 enclosure kit available
RoHS compliant
©2022 Advanced Energy Industries, Inc.
LPS40
ELECTRICAL SPECIFICATIONS
Input
Input range
85 to 264 VAC or 120 to 300 VDC
Frequency
47 to 440 Hz
Inrush current
< 18 A peak @ 115 VAC, < 36 A peak @ 230 VAC, cold start @ 25 °C
Input current
1 A max. (RMS) @ 115 VAC
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted, CISPR 22 Class B conducted
EN55022 Class B conducted, VDE 0878 PT3 class B conducted
Safety ground leakage current
< 0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
40 W for convection, 55 W with 30 CFM forced air
Adjustment range
-5, +10% minimum
Hold-up time
20 ms @ 40 W load, 115 VAC nominal line
Overload protection
Short circuit protection on all outputs
Case overload protected @ 110% to 145% of peak rating
Overvoltage protection
5 V output: 5.7 to 6.7 V. Other outputs 110% to 125% of nominal output
Remote sense
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
ENVIRONMENTAL SPECIFICATIONS
Operating temperature
0° to 50 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C, -20 °C start
up
Storage temperature
-40 °C to +85 °C
Temperature coefficient
± 0.4% per °C
Electromagnetic susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity
Operating, non-condensing 5% to 95% RH
Vibration
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G
peak 5 Hz to 500 Hz, operational
MTBF demonstrated
> 550,000 hours at full load and 25 °C ambient conditions
2 advancedenergy.com
LPS40
ORDERING INFORMATION
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak Load1
Regulation2
Ripple
P/P(PARD)3
LPS41
3.3 V
0A
8A
11 A
12 A
± 2%
50 mV
LPS42
5V
0A
8A
11 A
12 A
± 2%
50 mV
LPS43
12 V
0A
3.3 A
4.5 A
5A
± 2%
120 mV
LPS44
15 V
0A
2.6 A
3.6 A
4A
± 2%
150 mV
LPS45
24 V
0A
1.7 A
2.3 A
2.5 A
± 2%
240 mV
LPS48
48 V
0A
0.9 A
1.2 A
1.3 A
± 2%
480 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. T his product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not
intended for sale to End Users.
Power Derating Curve
55W
30 CFM Forced Air Cooling
40W
Output
Power
(Watts)
30W
20W
Natural
Convection
Cooling
27.5W
20W
10W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
advancedenergy.com
3
LPS40
MECHANICAL DRAWING
1. Specifications subject to change without notice.
2. A ll dimensions in inches (mm), tolerance is ±0.02" (±0.5 mm).
3. M ounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. S
pecifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated.
6. Warranty: 2 years.
7. Weight: 0.5 lbs/0.23kg.
4 advancedenergy.com
LPS40
PIN ASSIGNMENTS
Connector
LPS41
LPS42
LPS43
LPS44
LPS45
LPS48
SK1-1
Line
Line
Line
Line
Line
Line
SK1-3
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral
SK2-1
+3.3V
+5V
+12V
+15V
+24V
+48V
SK2-2
+3.3V
+5V
+12V
+15V
+24V
+48V
SK2-3
+3.3V
+5V
+12V
+15V
+24V
+48V
SK2-4
Common
Common
Common
Common
Common
Common
SK2-5
Common
Common
Common
Common
Common
Common
SK2-6
Common
Common
Common
Common
Common
Common
SK201-1
+Sense
+Sense
+Sense
+Sense
+Sense
+Sense
SK201-2
-Sense
-Sense
-Sense
-Sense
-Sense
-Sense
MATING CONNECTORS
AC Input
Molex 09-50-8031 (USA)
09-93-0300 (UK)
PINS: 08-52-0113
DC Outputs
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Remote Sense
Molex 22-01-2025
PINS: 08-52-0123
Artesyn Embedded Power Connector Kit #70-841-006, includes all of the above
advancedenergy.com
5
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions for
mission-critical applications and processes.
Our products enable customer innovation in complex
applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and medical.
With deep applications know-how and responsive service
and support across the globe, we build collaborative
partnerships to meet rapid technological developments,
propel growth for our customers, and innovate the future
of power.
For international contact information,
visit advancedenergy.com.
powersales@aei.com (Sales Support)
productsupport.ep@aei.com (Technical Support)
+1 888 412 7832
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks
of Advanced Energy Industries, Inc.
ENG-LPS40-235-01 4.20