LPT42

LPT42

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 5V +/-12V 40W

  • 数据手册
  • 价格&库存
LPT42 数据手册
ARTESYN LPT40 SERIES 40 W Advanced Energy's Artesyn LPT40 series of open-frame AC-DC power supplies comprises seven triple output models, covering a variety of standard voltages from -15 V to 24 V. Each model accepts a universal input of 85 to 264 VAC or 120 to 300 VDC. These compact switch-mode power supplies feature main output overvoltage protection and remote sense, with short-circuit protection on all outputs. Depending on the model, they provide up to 40 W of output power with free air convection cooling and up to 55 W with 30 CFM of forced air. Less than 1U high, LPT40 series power supplies are suitable for a variety of uses including test and measurement, single-board computers, telecommunications and networking. SPECIAL FEATURES SAFETY  Universal input  CE  3" x 5" footprint  NEMKO CB cert IEC60950-1  Less than 1U high  Remote sense on main output  Built-in EMI filter AT A AGLNCE Total Power: 44 to 55 W Input Voltage: 85 to 264 VAC 120 to 300 VDC # of Outputs: Triple  NEMKO test report IEC60950-1  UL+cUL  UKCA Mark  Low output ripple  Adjustable main output  Overvoltage protection  Overload protection  110 KHz switching frequency  LPX40 enclosure kit available  RoHS compliant ©2023 Advanced Energy Industries, Inc. LPT40 ELECTRICAL SPECIFICATIONS Input Input range 85 to 264 VAC or 120 to 300 VDC Frequency 47 to 440 Hz Inrush current < 18 A peak @ 115 VAC < 36 A peak @ 230 VAC, cold start @ 25 °C Input current 1 A max. (RMS) @ 115 VAC Efficiency 70% typical at full load (60% for LPT41) EMI FCC Class B conducted, CISPR 22 Class B conducted EN55022 Class B conducted, VDE 0878 PT3 Class B conducted Safety ground leakage current < 0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum power 40 W for convection (LPT41, 25 W) 55 W with 30 CFM forced air (LPT41, 41 W) Cross regulation ±2% on output 1, ±5% on outputs 2, 3 Adjustment range -5, +10% min. Hold-up time 20 ms @ 40 W load, 115 VAC nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110% to 145% of peak rating Overvoltage protection 5.7 to 6.7 V on the main output (LPT41, 3.6 to 4.6 V) Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C start up Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating, non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature -40 °C to 85 °C Temperature coefficient ±.04% per °C MTBF demonstrated > 550,000 hours at full load and 25 °C ambient conditions 2 advancedenergy.com LPT40 ORDERING INFORMATION Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Forced Air Peak Load1 Regulation2 Ripple P/P(PARD)3 LPT41 +3.3 V +5 V +12 V 0.5 A 0A 0A 4A 1.5 A 0.5 A 7A 2.0 A 0.7 A 7A 2.5 A 0.7 A ±2% ±2% ±5% 50 mV 50 mV 120 mV LPT42 +5 V +12 V -12 V 0.4 A 0.2 A 0A 4A 2A 0.5 A 5A 2.5 A 0.7 A 7A 4A 1A ±2% ±5% ±5% 50 mV 120 mV 120 mV LPT43 +5 V +12 V -12 V 0.5 A 0A 0A 6A 0.5 A 0.5 A 8A 0.7 A 0.7 A 9A 1A 1A ±2% ±5% ±5% 50 mV 120 mV 120 mV LPT44 +5 V +12 V -5 V 0.4 A 0.2 A 0A 4A 2A 0.5 A 5A 2.5 A 0.7 A 7A 4A 1A ±2% ±5% ±5% 50 mV 120 mV 50 mV +5 V 0.4 A 4A 5A 7A ±2% 50 mV LPT45 +15 V 0.2 A 2A 2.5 A 3A ±5% 150 mV -15 V 0A 0.5 A 0.7 A 1A ±5% 150 mV +5 V 0.4 A 4A 5A 6A ±2% 50 mV +24 V 0.1 A 1.0 A 1.5 A 2A ±7% 240 mV +12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV LPT46 LPT47 +5 V 0.4 A 4A 5A 6A ±2% 50 mV +24 V 0.2 A 1.0 A 1.5 A 2A ±7% 240 mV -12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. 5.  T his product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Power Derating Curve 55W 30 CFM Forced Air Cooling 40W Output Power (Watts) 30W 20W Natural Convection Cooling 27.5W 20W 10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature-°C advancedenergy.com 3 LPT40 MECHANICAL DRAWING 0.22" (5.6) 4.55" (115.6) M1 GND 3.00" (76.2) 2.55" (64.8) 3 1 SK 1 N 5.00" (127) SK201 M2 _+ 1 2 3 4 5 6 Remote Sense Connector Voltage Adj. Pot SK 2 L 0.15" (4) DIA (4 places) 1.14" (29) 0.197" (5) 4 advancedenergy.com LPT40 PIN ASSIGNMENTS Connector LPT41 LPT42 LPT43 LPT44 LPT45 LPT46 LPT47 SK1-1 Line Line Line Line Line Line Line SK1-3 Neutral Neutral Neutral Neutral Neutral Neutral Neutral SK2-1 5V +12V +12V +12V +15V +24V +24V SK2-2 3.3V +5V +5V +5V +5V +5V +5V SK2-3 3.3V +5V +5V +5V +5V +5V +5V SK2-4 Common Common Common Common Common Common Common SK2-5 Common Common Common Common Common Common Common SK2-6 12V -12V -12V -5V -15V +12V -12V SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense +Sense SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense -Sense MATING CONNECTORS AC Input Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Remote Sense Molex 22-01-2025 PINS: 08-52-0123 Artesyn Embedded Power Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5 mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. Warranty: 2 years. 7. Weight: 0.5 lbs/0.23 kg. advancedenergy.com 5 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. Our products enable customer innovation in complex applications for a wide range of industries including semiconductor equipment, industrial, manufacturing, telecommunications, data center computing, and medical. With deep applications know-how and responsive service and support across the globe, we build collaborative partnerships to meet rapid technological developments, propel growth for our customers, and innovate the future of power. TRUST For international contact information, visit advancedenergy.com. powersales@aei.com (Sales Support) productsupport.ep@aei.com (Technical Support) +1 888 412 7832 Specifications are subject to change without notice. Not responsible for errors or omissions. ©2023 Advanced Energy Industries, Inc. All rights reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks of Advanced Energy Industries, Inc. ENG-LPT40-235-01 1.29.23
LPT42 价格&库存

很抱歉,暂时无法提供与“LPT42”相匹配的价格&库存,您可以联系我们找货

免费人工找货