80 Watts
Total Power:
55 - 85 Watts
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs:
Triple
Special Features
•
•
•
•
•
•
•
•
•
•
Power Factor Correction
EN61000-3-2 compliant
Universal input
3” x 5” footprint
Remote sense on outputs 1
(& 2 for LPT81)
Power fail and remote inhibit
Wide range adjustable on
outputs 1 (& 2 for LPT81)
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Electrical Specifications
Input
Input range:
85 - 264 Vac; 120 - 300 Vdc
Frequency:
47 - 440 Hz
Inrush current:
< 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac,
cold start @ 25 °C
Input current:
1.5 A max. (RMS) @ 115 Vac
Efficiency:
EMI filter:
75% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground
leakage current:
< 1 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
Safety
•
•
•
•
•
•
•
VDE
UL
CSA
NEMKO
AUSTEL
CB
CE
Adjustment range:
60950
60950
60950
60950
60950
Certificate & report
Mark LVD
Hold-up time:
Overload protection:
60 W for convection (LPT81, 55 W);
85 W with 30 CFM forced air
3.3 V - 5.5 V on outputs one
(and two 1.8 V - 3.5 V for LPT81)
20 ms @ 85 W load, 115 Vac nominal line
Short circuit protection on all outputs.
Case overload protected @ 145% above peak rating
Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above output setting
Embedded Power for
Business-Critical Continuity
Rev. 6.25.12_161
LPT80 Series
2 of 3
Logic Control
Power failure:
TL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before
T
loss of regulation
Remote inhibit:
Requires contact closure to inhibit outputs
Remote sense:
Compensates for 0.5 V lead drop min. Will operate without remote sense connected.
Reverse connection protected.
Environmental Specifications
Operating temperature:
0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
Temperature coefficient: ± 0.4% per °C
Storage temperature:
- 40° to 85 °C
Electromagnetic
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
susceptibility:
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G
peak 5 Hz to 500 Hz, operational
> 550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Model
Number
LPT81
LPT82
LPT83
Output Voltage
Minimum
Load
+3.3 V (1.8 - 3.5 V)
+5 V (3.3 - 5.5 V)
+12 V
+5 V (3.3 - 5.5 V)
+12 V
-12 V
+5 V (3.3 - 5.5 V)
+15 V
-15 V
0.7 A
0.3 A
0
0.7 A
0.3 A
0
0.7 A
0.3 A
0
Maximum Load with Maximum Load with
Peak Load 1 Regulation 2
Convection Cooling
30CFM Forced Air
8.0 A
4.0 A
0.7 A
8.0 A
3.0 A
0.7 A
8.0 A
2.4 A
0.7 A
13 A
13 A
1.0 A
13 A
4.0 A
1.0 A
13 A
3.2 A
0.7 A
15 A
15 A
1.5 A
15 A
4.6 A
1.5 A
15 A
3.7 A
1A
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum loads are required
5. Total current of all outputs can not exceed 21 A.
±2%
±2%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
Ripple P/P
(PARD)3
50 mV
50 mV
120 mV
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.23 (5.8)
Americas
5.00
(127.0)
(4x) .14 (Ø 3.6)
Rev. 6.25.12_161
LPT80 Series
3 of 3
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
1
Europe (UK)
3.00
(76.2)
8
2.55"
(64.8)
0.22 (5.6)
5
10
1
6
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
4.56"
(115.8)
0.22 (5.6)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
Pin Assignments
Mating Connectors
Connector
SK1 Pin1
Pin3
SK2 Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
SK3 Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
Pin7
Pin8
Pin9
Pin10
AC Input (SK1):
LPT81
Neutral
Line
V1 (3.3V)
V1 (3.3V)
Common
Common
Common
V2 (5V)
V2 (5V)
V3 (12V)
+V1 Remote sense
-V1 Remote sense
+Remote inhibit
-Remote inhibit
+Power fail
Common
No connection
+V2 sense
-V2 sense
No connection
LPT82/83
Neutral
Line
V1 (5 V)
V1 (5 V)
Common
Common
Common
V2 (12/15V)
V2 (12/15V)
V3 (-12V/15)
+V1 Remote sense
-V1 Remote sense
+Remote inhibit
-Remote inhibit
+Power fail
Common
No connection
No connection
No connection
No connection
Molex 09-50-8031 (USA)
Molex 09-91-0300 (UK)
PINS: 08-58-0111
DC Outputs (SK2): Molex 09-50-8081 (USA)
09-91-0800 (UK)
PINS: 08-58-0111
Control Signals
(SK3):
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Emerson Network Power Connector Kit #70-841-018
includes all the above.
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”.
3. Mounting holes M1, M2 and M3 should be
grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at
factory settings at 115 VAC input, 25 °C unless
otherwise stated.
6. Warranty: 2 year
7. Weight: 0.8 lb. / 0.36 kg
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson and the Emerson Network Power
logo are trademarks of Emerson Electric Co.
©2012 Emerson Electric Co.
All rights reserved.
很抱歉,暂时无法提供与“LPT81”相匹配的价格&库存,您可以联系我们找货
免费人工找货