MP8-2E-1E-1L-1N-1O-00 数据手册
400 - 1200 Watts
MP Series
Special Features
MP4
MP6
• Current share on all outputs with ratings
of 10 A or greater
• Remote sense on all outputs with ratings
greater than 2 A
• Overload protection on all outputs
• Voltage adjustment on all outputs
• Margining on all single output modules
• Input OK signal and status indicator LED
• Global DC OK signal and status indicator LED
• Global and individual module inhibits/enable
• 1 year warranty
• Forced air cooling, field replaceable fan
• Isolated 5 V bias voltage
• Power factor correction
• EN61000-3-2 harmonic distortion compliance
• CISPR 22, EN55022 Curve B conducted / radiated EMI
• European CE Mark requirements
• Optional VME timing and system DC OK module
• Customer-provided air option
• Additional 200 W output @ high line (180-264 VAC)
• Low leakage option for medical applications
• EN61000 immunity standards
• Standard modification flexibility (consult factory)
Low noise fan
Fan fail signal
Module enable
Outputs down to 0.5V
Environmental
Operating temperature: -20°C to 50°C (start @ 0°C)
(derate each output linearly to 50% at 70°C)
(-20°C to 40°C max. with rear air option)
Shock/Vibration: Mil-Hdbk 810E
MP8
Humidity: 95% non-condensing
Storage temperature: -40°C to +85°C
Temperature coefficient: 0.02% per °C
Cooling: Internal DC fan or customer provided air (option)
Safety
MP1
136
UL
CSA
IEC
VDE
BABT
CB
CE
UL1950
CSA22.2 No. 234 Level 5
IEC950, Class 1
EN60950,
Compliance to EN 60950, BS 7002
Certificate and report
Mark
Technical Support: (888) 41ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 04.16.04
EUROPE
ASIA
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
MP Series
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Electrical Specs
Output
Input
Input voltage
85-264 VAC
120-350 VDC
47-440 Hz
40 A peak max. (soft start)
70-80% typ. @ full case load
0.99 typ. meets EN61000-3-2
AC on 1.5 sec typ.,
Inhibit / Enable 150 ms typ.
CISPR 22
EN55022 Level “B”
Frequency
Inrush current
Efficiency
Power factor
Turn-on time
EMI filter standard
EMI filter
(low leakage option)
±10% min. all outputs
Margining
Overall reg
±4-6% nom.
0.4% or 20 mV max.
(36 W modules 4% max.)
RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater
Bandwidth limited to 20 MHz
5 ms warning
(AC OK signal) before shutdown
Up to 0.5 V total drop (not available on triple
output module)
2
Single wire parallel
Current share to within 2% of total rated current
DC OK
Minimum load
-2% to -8% of nominal for any monitored output
Not required on single or triple output modules.
2
3
80
%
Rated
Total
Case
Load
Normal
Air Flow
Housekeeping bias voltage
Module inhibit
60
50
Switching frequency
Output/Output isolation
VME signal option board
40
20
30
35
40
45
50
55
60
65
10% required on main of dual output modules
5 VDC @1.0A mA max. present whenever AC
input is applied
TTL, isolated, singles and dual
(both outputs) only
250 kHz
>1 Megohm
POR signal & quad external DC OK
70
TA Ð Ambient Temperature Ð °C
Notes:
1. Single output modules only.
2. Single and main of dual output modules only.
3. Contact factory for optional preload if required.
www.astecpower.com
137
Common Examples
and Specifications
Modules
Single
Outputs
Max output power
Max output current
Volts
Triple
Dual
1
1
1
2
3
210 W
360 W
600 W
144 W
36 W
35 A
60 A
120 A
10 A
2A
2-60 V
2-60 V
2-60 V
2-28 V
2-28 V
Standard voltage increments
25
25
25
19
18
Remote sense on outputs
Yes
Yes
Yes
Yes, both
No
Remote margin/V-Program
Yes
Yes
Yes
No
No
Module inhibit (isolated)
Yes
Yes
Yes
---
---
Single wire active current share
Yes
Yes
Yes
Yes, main only
---
Over voltage / Over current protection
Yes
Yes
Yes
Yes
Over current
Minimum load required
No
No
No
Yes (10%), main only
No
1
2
3
1
1
Slots occupied in any MP case
Modules
Voltage
Voltage
Single Output
Dual
Code
Module Code
Output
1
2V
2.2 V
3V
3.3 V
5V
5.2 V
5.5 V
6.0 V
8.0 V
10 V
11 V
12V
14 V
15 V
18 V
20 V
24 V
28 V
30 V
33 V
36 V
42 V
48 V
54 V
60 V
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Non-std
Z
2.4V-2.7V
3.6V-4.5V
6.6V-9.2V
8.8V-9.0V
1
3
3
Output
1
V1
V2
V1
V2
V3
35A
35 A
35A
35 A
35A
35 A
34 A
23 A
20 A
18 A
17 A
17A
14 A
14 A
11 A
10.5 A
8.5 A
6.7 A
6.5 A
6.2 A
5.8 A
4.2 A
4.0 A
3.7 A
3.5 A
60 A
60 A
60 A
60 A
60 A
60 A
58 A
42 A
36 A
32 A
31 A
30 A
21 A
20 A
19 A
18 A
15 A
12.8 A
12 A
10.9 A
10 A
7.5 A
7.5 A
6.0 A
6.0 A
120 A
120 A
120 A
120 A
120 A
115 A
109 A
78 A
68 A
60 A
54.5 A
50 A
40.5 A
39 A
33.3 A
30 A
23.5 A
21.4 A
20 A
18.2 A
16.6 A
12.5 A
12.5 A
11 A
10 A
—
—
—
—
10 A
—
—
—
—
—
—
10 A
9A
8A
—
—
4A
3A
—
—
—
—
—
—
—
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
—
—
—
4A
4A
4A
—
—
2A
2A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1A
1A
1A
1A
1A
1A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1A
1A
1A
1A
1A
1A
0.5 A
0.5 A
0.5 A
0.5 A
—
—
—
—
—
—
—
2A
2A
2A
2A
2A
2A
2A
2A
1A
1A
1A
1A
1A
1A
0.5 A
0.5 A
0.5 A
0.5 A
—
—
—
—
—
—
—
35
35
20
18
60
60
36
32
120
120
68
60
—
—
10
10
10
10
4
4
—
—
—
—
—
—
—
—
2
2
1
1
Notes:
1
Takes up one slot.
2
Takes up two slots.
3
Takes up three slots.
138
2
2
Triple
1
Single Output Example
5 V @ 60A
Module Code
Voltage Code
2
E
1
Dual Output Example
12 V @ 10 A
5 V @ 10 A
Module Code
always 4
4
Voltage Code
L
E
3
Triple Output Example
12 V @ 1 A
20 V @ 0.5 A
5V@2A
2
Voltage Code
L P E
Notes:
1. Total load not to exceed 144 W.
2. No module code required.
3. Total load not to exceed 36 W.
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
EUROPE
ASIA
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
OPTION CODE
0 = no options
1 = rear air exhaust
3 = global enable
5 = option package (options 1 & 3)
M = low leakage
N = low leakage plus option 1
P = low leakage plus option 3
R = low leakage plus option 5
Ordering Information
Input
Slots
5 available slots
5 available slots
6 available slots
7 available slots
Slot #1
-
600 W max.
800 W max.
1000 W max.
1200 W max.
Slot #3
-
2 or 3 digit code
See previous page.
Slot #5
Slot #4
-
-
-XXX
Use Only for
Modified Standard
Slot 4
Slot 2
Slot 1
Slot 2
Slot 2
Slot 1 Slot 1
6
Slot 3 Slot 3
7
Slot 3
MP1
available slots
Standard
Parallel Codes*
0 = no parallel
Slot 5
MP8
available slots
Slot 4
MP4 & MP6
available slots
3
2
1
5 4
1=1&2
2=2&3
3=3&4
4=4&5
2 F / 1 L - 4 L E - L L E -0M-XXX
Slot 4
Output 3: 12 V @ 10
Output 4: 5 V @ 10 A
PARALLEL CODE
Slot 4
Factory assisted code
Slot 5
Output 5: 12 V @ 1 A for modifications
Output 6: 12 V @ 1 A
Output 7: 5 V @ 2 A
Slot 3
Output 2: 12 V @ 17 A
Slots 1 & 2
Output 1: 5.2 V @ 60 A
-
Use “ — ” for Standard Remote Sense
Use “ / ” After any module using Remote Sense with
or-ing diode (redundancy)
EXAMPLE
MP8-
(MP1 Only)
Slot #7
-
Notes:
1. Omit digits that do not apply.
2. Specify modules from lowest number of outputs to highest. (Single/Dual/Triple)
3. If number of outputs are equal, specify modules from highest to lowest power increments. If
power increments are equal, specify in descending alphabetical order (1A, B, C . . .).
4. Always start with Slot 1.
5. All MP model configurations created using this selection guide are standard MP products with
standard availability and lead times.
6. Optional VME/DCOK module must always be located in the last slot. Module designator is “VME”.
2.5” x 7” x 10”
(6 slots available)
(MP8 & MP1 Only)
Slot #6
Slot 6
-
400 W max.
600 W max.
800 W max.
1000 W max.
Slot 5 Slot 5
MP
Slot #2
180-2
264 VAC
Slot 7
4 = 2.5 x 5 x 10
6 = 2.5 x 5 x 11
8 = 2.5 x 7 x 10
1 = 2.5 x 8 x 11
85-2
264 VAC
Slot 6
Case Size (inches)
MP Series
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
5=3&4&5
6=5&6
No Paralleling
7 = 4, 5 & 6
Low Leakage
8=6&7
9 = 3 & 4, 6 & 7
SINGLE OUTPUTS
Total
Power
Output
(Volts/Amps)
Size
(inches)
Model Numb
360 W
400 W
600 W
600 W
600 W
800 W
800 W
1000 W
2 / 180
5 / 80
2 / 275
5 / 120
48 / 12.5
5 / 160
48 / 16.6
5 / 200
2.5 x 5 x 10
2.5 x 5 x 10
2.5 x 8 x 11
2.5 x 5 x 11
2.5 x 5 x 11
2.5 x 7 x 10
2.5 x 7 x 10
2.5 x 8 x 11
MP4-3A-2A-30
MP4-3E-00 - 429
MP6-3A-3A-1A-90
MP6-3E-00
MP6-3W-00
MP8-3E-2E-30 - 415
MP8-3W-1W-30
MP1-3E-3E-30 - 404
*For custom parallel configurations contact
Astec Power Technical Support.
MULTIPLE OUTPUTS
Total
Power
Output 1
Output 2
(Volts/Amps)
Output 3
Output 4
Output 5
Output 6
Size
(inches)
Model Number
400 W
400 W
400 W
400 W
600 W
600 W
600 W
800 W
800 W
800 W
800 W
1000 W
5 / 60
24 / 15
5 / 60
5 / 35
3 / 60
5 / 120
12 / 30
36 / 16.6
5 / 120
15 / 20
2 / 180
3.3 / 120
12 / 1
5 / 35
12 / 10
3.3 / 10
12 / 10
12 / 10
—
5 / 10
12 / 17
15 / 14
—
—
12 / 1
—
5 / 10
12 / 1
12 / 4
5 / 10
—
12 / 10
12 / 10
24 / 8.5
—
—
12 / 1
—
—
12 / 1
—
—
—
12 / 4
12 / 4
15 / 8
—
—
—
—
—
5/2
—
—
—
—
—
5 / 10
—
—
2.5 x 5 x 10
2.5 x 5 x 10
2.5 x 5 x 10
2.5 x 5 x 10
2.5 x 5 x 11
2.5 x 5 x 11
2.5 x 5 x 11
2.5 x 7 x 10
2.5 x 7 x 10
2.5 x 7 x 10
2.5 x 7 x 10
2.5 x 8 x 11
MP4-2E-1D-LLL-00
MP4-2Q-1L-1E-00
MP4-2E-1L-4LE-00
MP4-1E-4LD-LLE-00
MP6-2C-2E-4LL-00
MP6-3E-1L-4LE-00
MP6-2L-1E-00
MP8-3U-4QE-4LL-00
MP8-3E-1D-1L-4LL-00
MP8-2N-1E-1N-1Q-4NE-00
MP8-3A-2A-2E-30
MP1-3D-3E-00
www.astecpower.com
3.3 / 35
12 / 17
12 / 17
12 / 10
5 / 60
12 / 17
5 / 35
24 / 4
3.3 / 35
5 / 35
5 / 60
5 / 120
139
Drawings
MP MODULES
Single 210 Watt
.44 (11.2 )
V+
(2X)
DC-DC Converter Output Modules
M4X8 SCREWS (2X)
Control Signal Information, J1 Control Connector
.48 (12.1)
Pin No.
Function
1
2
3
4
5
6
7
8
9
10
+ Remote Sense
Remote Margin / V. Program
Margin High
- Remote Sense / Margin Low
Spare
Module, Isolated Inhibit
Module Inhibit return
Current Share (SWP)
+ Remote Sense V2
- Remote Sense V2
single or dual o/p main
single o/p
single o/p
single or dual o/p main
V-
1.38
(35.1)
single or dual o/p
single or dual o/p
single or dual o/p main
dual o/p, single is spare
dual o/p, single is spare
V ADJ
.44 (11.3)
PIN 1
.32
(8.1)
Single 600 Watt
Single 360 Watt
.63 (16.0)
V+
.59
(15.0)
M4X8 SCREWS (4X)
.63
(16.0)
V+
V ADJ
.32 (8.1)
V.44
(11.3)
PIN 1
.61 (15.6)
M4X8 SCREWS (4X)
V-
1.24 (31.6) (2X)(2X)
.48 (12.1)
1.38 (35.1)
(2X)
(2X)
.44 (11.3)
.33 (8.5)
V ADJ
.32
(8.1)
PIN 1
Triple 36 Watt
Dual 144 Watt
.46 (11.7)
V1 ADJ
V1 +
(4X)
V1 -
V1+
V1V2 ADJ
V2+
V2PIN 1
V3+
V3DC OUTPUT CONNECTION
V2 +
V2 M3X8 SCREWS (4X)
1.17 (29.7)
V1 ADJ
.42 (10.7)
.32
(8.1)
140
V2 ADJ
.84
(21.3)
.30 (7.5) (3X)
.48
(12.1)
V3 ADJ
PIN 1
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
EUROPE
ASIA
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
MP Series
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
5-IInch Case Size: MP4: 2.5” x 5” x 10” (63.5mm x 127mm x 254mm)
5-IInch Case Size: MP6: 2.5” x 5” x 11” (63.5mm x 127mm x 279.4mm)
Weight: MP4 Case: 2.6 lbs. • MP6 Case: 3.2 lbs. • 36 W Triple: 0.5 lb.
210 W Single: 0.6 lb. • 360 W Single 1.0 lb. • 600 W Single: 2.0 lbs.
144 W Dual: 0.6 lb.
MP Series
MP4 (400/600 Watts Max)
MP6 (600/800 Watts Max)
#8-32 MTG HOLES
4 PL
MARKED "A"
PFC Input Information
171.45
6.750
J1 Control Connector Standard for all cases
Pin No.
Function
J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
J1-9
J1-10
Input AC OK - “Emitter”
Input AC OK - “Collector”
Global DC OK - “Emitter”
Global DC OK - “Collector”
Spare
Global Inhibit/Optional Enable Logic “0”
Global Inhibit/Optional Enable Logic “1”
Global Inhibit/Optional Enable Return
SELV 5V Housekeeping
SELV 5V Housekeeping Return
A
19.05
.750
B
M4 MTG HOLES
4 PL
MARKED "B"
B
Standard Airflow
101.60
4.000
A
B
A
B
29.05
1.144
171.45
6.750
3.5
.14
12.70
.500
(TYP)
M4 MTG HOLES 4 PL
38.10 63.5 +.0
-.5
1.500
2.50 +.00
-.02
17.3 +
- 1.0
.68 +-.04
MP4
0
254.0 +.
-.5
MP6
279.4 +.0
-.5
10.00 +.00
-.02
11.00 +.00
-.02
171.45
6.750
12.70
.500
19.05
.750
3.7TYP
.15
MOUNTING HOLES DIMENSIONS IDENTICAL ON BOTH SIDES
+.0
127.0
-.5
+.00
5.00
-.02
19.0
.75
1
49.2
1.94
4.3 +.8
.17 +-.03
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
5
4
3
2
1
23.9 +-.5 (4 PL)
.94 +-.02
-A-
NON-CUMULATIVE
2
Notes
1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375” centers). Max torque: 6 in-lbs. (0.67 N-m).
2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts
(Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins,
Astec part #70-841-004.
3. Chassis material: aluminum with chemical film coating (conductive).
4. All dimensions are in millimeters and inches, and are typical.
5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150” (3.8mm). Max. torque: 5in-lbs.
6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs.
Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs.
Triple O/P module is .045” square pins on .156” centers. Mates with Molex 09-50-8063 or equivalent.
www.astecpower.com
141
Drawings
MP Series
MP8 (800/1000 Watts Max)
7-IInch Case Size: MP8: 2.5” x 7” x 10” (63.5mm x 177.8mm x 254mm)
Weight: MP8 Case: 4.1 lbs. • 36 W Triple: 0.5 lb. • 210 W Single: 0.6 lb. • 360
W Single: 1.0 lb. • 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb.
12.70
0.5
254
10.0
M4 MOUNTING HOLES
MARKED "B" (4X)
"A"
Standard Airflow
171.45
6.75
19.05
0.75
"B"
"B"
"A"
152.40
6.0
"A"
"A"
"B"
"B"
171.45
6.75
#8-32 MOUNTING HOLES
MARKED "A" (4X)
29.05
1.1
19.05
0.7 D
171.45
6.75
38.10
1.5
35.0
1.38
M4 MOUNTING HOLES
254
10.0
12.70
0.5
60.5
2.38
177.8
7.0
AC INPUT
14.7
0.58
177.8
7.0
(4X)
59.5
2.34
31.8
1.25
14.0
0.55
63.5
2.5
63.5
2.5
2
1
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
6
5
4
3
2
1
OUTPUT MODULE AREA
Notes
1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375” centers). Max torque: 6 in-lbs. (0.67 N-m).
2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts
(Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins,
Astec part #70-841-004.
3. Chassis material: aluminum with chemical film coating (conductive).
4. All dimensions are in millimeters and inches, and are typical.
5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150” (3.8mm). Max. torque: 5in-lbs.
6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs.
Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs.
Triple O/P module is .045” square pins on .156 centers. Mates with Molex 09-50-8063 or equivalent.
142
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
EUROPE
ASIA
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
8-IInch Case Size: MP1: 2.5” x 8” x 11” (63.5mm x 203.2mm x 279.4mm)
Weight: MP1 Case: 5.0 lbs. • 36 W Triple: 0.5 lbs. • 210 W Single: 0.6 lbs. • 360
W Single: 1.0 lb. • 600 W Single: 2.0 lbs.
144 W Dual: 0.6 lb.
MP Series
MP Series
MP1 (1000/1200 Watts Max)
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
1
2
Notes
1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375” centers). Max torque: 6 in-lbs (0.67 N-m).
2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts
(Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins.
Connector kit includes mating connector and 10 pins, Astec part #70-841-004.
3. Chassis material: aluminum with chemical film coating (conductive.
4. All dimensions are in millimeters and inches, and are typical.
5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150” (3.8mm). Max. torque: 5in-lbs.
6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs.
Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs.
Triple O/P module is .045” square pins on .156 centers. Mates with Molex 09-50-8063 or equivalent.
www.astecpower.com
143