Embedded Power for
Business-Critical Continuity
Rev.02.01.10_65
NFS40 Series
1 of 4
NFS40 Series
SIngle and
triple output
Total Power: 40 - 50W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs:
Single, triple
Electrical Specifications
Special Features
• 5.0 x 3.0 x 1.2 inch package
(1U applications)
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
conducted noise level B
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Input
Voltage adjustability:
+5 V output on triples
Vout on singles
± 5.0%
± 5.0%
Line regulation:
LL to HL, FL
Main output
Auxiliary outputs
± 0.2%
± 1.0%
Load regulation:
FL to NL
Main output
Auxiliary outputs
± 2.0%
± 5.0%
Transient response:
+5 V (1.5 - 3 A)
± 120 mV max. dev.
500 µs recovery
Temperature coefficient:
All outputs
± 0.02%/°C
Overvoltage protection:
+5 V output
S3.15 A, 250 Vac In live and neutral
Output power limit:
Primary power limited
90 W input power limit
Short circuit protection:
Single outputs
Multiple outputs
Continuous
Short term
Universal input
85 - 264 Vac
120 - 370 Vdc
Output
Input voltage range:
Input frequency range:
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
• File No. 10401-3336-0044
• License No. 2559
• UL1950 File No. E136005
• CSA C22.2 No. 950
• File No. LR41062C
47-440 Hz
Max. input surge current:
132 Vac, cold start
264 Vac, cold star
12 A max.
24 A max.
Safety ground leakage current:
110 Vac, 60 Hz
230 Vac, 50 Hz
0.13 mA, max.
0.32 mA, max.
Embedded Power for
Business-Critical Continuity
Rev.02.01.10_65
NFS40 Series
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC Charateristics (11, 12)
Conducted emissions:
EN55022, FCC part 15
Level B
Radiated emissions:
EN55022
Level A
ESD air:
EN61000-4-2, level 3
Perf. criteria 1
ESD contact:
EN61000-4-2, level 4
Perf. criteria 1
Surge:
EN61000-4-2, level 3
Perf. criteria 1
Fast transients:
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3
Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3
Perf. criteria 2
110 Vac, 40 W
230 Vac, 40 W
14 ms
110 ms
General Specifications
Hold-up time:
Efficiency:
Isolation voltage:
70% typical
Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency:
Variable
Approvals and standards: (see VDE0805, EN60950, IEC950, IEC1010,
Notes 9, 13)
UL1950, CSA C22.2 No. 950
Weight:
280 g (9.88 oz)
MTBF demonstrated:
MIL-HDBK-217E
170,000 hours
Environmental Specifications
Thermal performance:
Operating
0° C to +70 °C
(See notes 8, 10)
Non-operating
-40 °C to +85 °C
50 °C ambient temp.,
convection cooled
40 W
Forced air cooling
50 W @ 20 CFM
+50 °C to +70 °C ambient
Derate linearly to 50% load
Peak (60 seconds)
60W
Relative humidity:
Non-condensing
5 to 80% RH
Altitude:
Operating
10,000 feet max.
Non-operating
40,000 feet max.
5-500 Hz
2.4 G rms peak
Vibration (See Note 11):
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Output Currents
Ripple (4)
Total
Regulation (5)
Fan (3)
Model Numbers (13, 14, F)
Max (1)
Peak (2)
+5.1 V (A)
3A
7A
5A
50 mV
± 2.0%
+12 V (B)
2A
3A
2A
120 mV
± 5.0%
–12 V (C)
0.35 A
1A
0.5 A
120 mV
± 5.0%
+5.1 V (A)
4A
7A
5A
50 mV
± 2.0%
+12 V (B)
0.35 A
1A
0.5 A
120 mV
± 5.0%
-12 V (C)
0.35 A
1A
0.5 A
120 mV
+ 5.0%
+5.1 V (A)
3A
7A
5A
50 mV
± 2.0%
+12 V (B)
2A
3A
2A
120 mV
± 5.0%
-5.0 V (C)
0.35 A
1A
0.5 A
50 mV
± 5.0%
+5.1 V (A)
3A
7A
5A
50 mV
± 2.0%
+15 V (B)
2A
2.5 A
2A
150 mV
± 10.0%/-3.0%
–15 V (C)
0.35 A
1A
0.5 A
150 mV
± 5.0%
3.3 V
6A
12 A
8A
100 mV
± 2.0%
NFS40-76S3J
+5.1 V
6A
12 A
8A
100 mV
± 2.0%
NFS40-7605J
+12.0 V
3.3 A
5A
4A
120 mV
± 2.0%
NFS40-7612J
+15.0 V
2.6 A
4A
3.3 A
150 mV
± 2.0%
NFS40-7615J
+24.0 V
1.6 A
2.5 A
2A
240 mV
± 2.0%
NFS40-7624J
Notes
1 Natural convection cooled, 40 W maximum.
2 Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth
using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, 0.25