ARTESYN
NLP40 SERIES
Single, Dual and Triple Output
Advanced Energy’s Artesyn NLP40 series of AC-DC power
supplies includes single, dual and triple output models,
covering voltages from 3.3 V to 48 V. Their compact 4.25 x
2.5 x 1.15 inch form factor makes them ideal for use in space
constrained and 1U applications. NLP40 power supplies
provide 40 watts of output power with free air convection
cooling, which can be boosted to 50 watts with 20 CFM of
forced air. Standard features include overvoltage and shortcircuit protection. The power supplies are designed for
use in low power data networking, computer and telecom
applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX systems. They are also
suitable for a wide range of low power industrial applications.
SPECIAL FEATURES
SAFETY
4.25 x 2.5 x 1.15 inch package
VDE0805/EN60950/IEC950
(1U applications)
Universal input
Overvoltage and short circuit
protection
40 W with free air convection
DATA SHEET
Total Power:
40 - 50 W
Input Voltage:
90 - 264 Vac
120 - 370 Vdc
# of Outputs:
Single, dual, triple
File 10401-3336-0093
Licence No. 93662
UL 60950 File No. E132002
CSA C22.2 No. 950
File No. LR41062C
EN55022, EN55011 conducted
emission level B
EN61000-4-2, -3, -4, -5, -6 immunity
compliant
UL, VDE and CSA safety approvals
NLP40 enclosure kit available
RoHS compliant
©2021 Advanced Energy Industries, Inc.
NLP40
ELECTRICAL SPECIFICATIONS
Input
Input voltage range
(See Note 9)
Universal input
Input frequency range
90 - 264 Vac
120 - 370 Vdc
47 - 440 Hz
Input surge current
120 Vac, cold start
230 Vac, cold start
15 A max.
30 A max.
Safety ground leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
0.2 mA
0.4 mA
Input current
120 Vac
230 Vac
1.4 A rms
0.7 A rms
Input fuse
UL/IEC127
250 Vac H 3.15 A
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Rise time
At turn-on
1.0 s, max.
Transient response
Main output
25% step at 0.1 A/µs
5.0% max. dev.,
1 ms rec. to 1.0%
Output
Temperature coefficient
±0.02%/°C
Overvoltage protection
Main outputs
135%, ±15%
Short circuit protection
Cyclic operation
Continuous
Minimum output current
Single
Multiple
0A
(See Note 5)
EMC CHARATERISTICS (10)
Conducted emissions
EN55022, FCC part 15
Level B
Radiated emissions
EN55022, FCC part 15
Level A
ESD air
EN61000-4-2, level 3
Perf. criteria 1
ESD contact
EN61000-4-2, level 3
Perf. criteria 1
Surge
EN61000-4-5, level 3
Perf. criteria 1
Fast transients
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity
EN61000-4-3, level 3
Perf. criteria 1
Conducted immunity
EN61000-4-6, level 3
Perf. criteria 1
2 advancedenergy.com
NLP40
GENERAL SPECIFICATIONS
Hold-up time
120 Vac
230 Vac
Efficiency
12 ms @ 40 W
20 ms @ 40 W
75% typical
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency
Fixed
65 kHz, ±5 kHz
Approvals and standards
(See Note 8)
UL, CSA VDE 60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Weight
MTBF demonstrated
200 g (7.06 oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient (see derating curve)
0° C to +70 °C
(See Notes 6, 7, 9)
Non-operating
-40 °C to +70 °C
50 °C to 70 °C ambient, convection cooled
Derate to 50% load
0 °C to 50 °C ambient, convection cooled
40 W
0 °C to 50 °C ambient, 20 CFM forced air
50 W
Peak (0 °C to +50 °C, 60 s)
(See Note 2)
Relative humidity
Non-condensing
5 to 95% RH
Altitude
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 4):
5-500 Hz
2.4 G rms peak
Shock
Per MIL-STD-810E
516.4 Part IV
advancedenergy.com
3
NLP40
ORDERING INFORMATION
Output Voltage
+3.3 V (IA)
Output Current
Max
(1)
4A
Ripple(3)
Total Regulation
Model
Number(11,12)
4.5 A
50 mV
±2.0%
NLP40-76T366J(5)
Peak(2)
Fan(1)
5A
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
–12 V (IC)
0.2 A
1A
0.5 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
–12 V (IC)
0.2 A
1A
0.5 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+15 V (IB)
1.6 A
2A
2A
150 mV
±5.0%
–15 V (IC)
0.2 A
1A
0.5 A
150 mV
±5.0%
+12 V (IA)
1.8 A
2.2 A
2.1 A
120 mV
±2.0%
-12 V (IB)
1.8 A
2.2 A
2.1 A
120 mV
±5.0%
+5 V (IA)
4A
5A
4.5 A
50 mV
±2.0%
+12 V (IB)
2A
3A
3A
120 mV
±5.0%
3.3 V (IA)
8A
10 A
9A
50 mV
±2.0%
NLP40-7608J(5)
NLP40-7610J(5)
NLP40-7627J(5)
NLP40-7629J(5)
NLP40-76S3J
5V
8A
10 A
9A
50 mV
±2.0%
NLP40-7605J
12 V
3.3 A
4.5 A
4A
120 mV
±2.0%
NLP40-7612J
15 V
2.6 A
3.6 A
3.3 A
150 mV
±2.0%
NLP40-7615J
24 V
1.6 A
2.5 A
2A
240 mV
±2.0%
NLP40-7624J
48 V
0.8 A
1.1 A
1A
300 mV
±2.0%
NLP40-7617J
Notes
1. Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W.
2. Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits.
3. Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF capacitor.
4. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
5. F
or multiple output units (except -7627J, 76T366J) to maintain stated regulation then:
0.25 ≤ IA / I B ≤5, for I B > 0.3 A
0.50 ≤ IA / I B ≤5, for I B < 0.3 A
For maximum output current I(C) on triple output models, i.e. for I C = IMax., I Amin. ≥0.5 A and IA ≥ I B .
For NLP40-7627J only, to maintain stated regulation then: 0.5 ≤ IA / I B ≤ 2.
For NLP40-76T366J only, to maintain stated regulation then: 0.25 ≤ IA / I B ≤ 4.
6. For optimum reliability, no part of the heatsink should exceed 120 °C, and no semiconductor case temperature should exceed 130 °C.
7. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
8. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
9. When the input voltage is