0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NLP40-7617

NLP40-7617

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 48V 40W

  • 数据手册
  • 价格&库存
NLP40-7617 数据手册
NLP40 Series • • • • • • • Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40W of output power with free air convection cooling which can be boosted to 50W with 20CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. All specifications are typical at nominal input, full load at 25°C unless otherwise stated 2 YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Total regulation (Line and load) Rise time Transient response Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note 9) Input frequency range Input surge current Safety ground leakage current Input current Input fuse 120VAC, cold start 230VAC, cold start 120VAC, 60Hz 230VAC, 50Hz 120VAC 230VAC UL/IEC127 (10) GENERAL SPECIFICATIONS ±2.0% ±5.0% 1.0s, max. 5.0% max. dev., 1ms rec. to 1.0% ±0.02%/°C Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards (See Note 8) Weight MTBF MIL-HDBK-217F Input/output Input/chassis Fixed 120VAC 230VAC 12ms @ 40W 20ms @ 40W 75% typical 3000VAC 1500VAC 65kHz, ±5kHz EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 200g (7.06oz) 150,000 hours min. Main output Auxiliary outputs At turn-on Main output 25% step at 0.1A/µs Main outputs Cyclic operation Single Multiple 135%, ±15% Continuous 0A (See Note 5) ENVIRONMENTAL SPECIFICATIONS Universal input 90 to 264VAC 120 to 370VDC 47Hz to 440Hz 15A max. 30A max. 0.2mA 0.4mA 1.4A rms 0.7A rms 250VAC H 3.15A Thermal performance (See Notes 6, 7, 9) Operating ambient, 0°C to +70°C (see derating curve) Non-operating -40°C to +70°C 50°C to 70°C ambient, Derate to convection cooled 50% load 0°C to 50°C, ambient, 40W convection cooled 0°C to 50°C ambient, 50W 20CFM forced air Peak (0°C to +50°C, 60s) (See Note 2) Non-condensing Operating Non-operating 5Hz to 500Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV Relative humidity Altitude Vibration (See Note 4) Shock EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 File Name: NLP40.PDF Rev: 01 Jan 2000 NLP40 Series OUTPUT VOLTAGE +5V (IA) +12V (IB) –12V (IC) +5V (IA) +15V (IB) –15V (IC) +12V (IA) -12V (IB) +5V (IA) +12V (IB) 5V 12V 15V 24V 48V Notes MAX (1) Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT RIPPLE PEAK 5.0A 3.0A 1.0A 5.0A 2.0A 1.0A 2.2A 2.2A 5.0A 3.0A 10A 4.5A 3.6A 2.5A 1.1A (2) (3) TOTAL REGULATION MODEL NUMBER NLP40-7608 (5) FAN (1) 4.0A 2.0A 0.2A 4.0A 1.6A 0.2A 1.8A 1.8A 4.0A 2.0A 8.0A 3.3A 2.6A 1.6A 0.8A 4.5A 3.0A 0.5A 4.5A 2.0A 0.5A 2.1A 2.1A 4.5A 3.0A 9.0A 4.0A 3.3A 2.0A 1.0A 50mV 120mV 120mV 50mV 150mV 150mV 120mV 120mV 50mV 120mV 50mV 120mV 150mV 240mV 300mV ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±5.0% ±2.0% ±5.0% ±2.0% ±5.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% NLP40-7610 (5) NLP40-7627 (5) NLP40-7629 (5) NLP40-7605 NLP40-7612 NLP40-7615 NLP40-7624 NLP40-7617 Output Power (Watts) Maximum output power is 40W for natural convection cooling. With 20CFM fan cooling, the maximum output power is 50W. 50W 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 20 CFM FORCED AIR COOLING 3 Figure is peak-to-peak. Output noise measurements are made across a 40W 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. 5 For multiple output units (except -7627) to maintain stated regulation then: NATURAL 25W 0.25 ≤ IA / IB ≤ 5, for IB > 0.3A CONVECTION 0.50 ≤ IA / IB ≤ 5, for IB < 0.3A COOLING 20W For maximum output current I(C) on triple output models, i.e. for IC = IMax., IA min. ≥ 0.5A and IA ≥ IB. For NLP40-7627 only, to maintain stated regulation then: 0.5 ≤ IA / IB ≤ 2. 6 For optimum reliability, no part of the heatsink should exceed 120°C, and no semiconductor case temperature should exceed 130°C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is
NLP40-7617 价格&库存

很抱歉,暂时无法提供与“NLP40-7617”相匹配的价格&库存,您可以联系我们找货

免费人工找货