Total Power:
Input Voltage:
# of Outputs:
65 - 75W
85 - 264 Vac
120 - 370 Vdc*
Single, dual,
triple
Electrical Specifications
Special Features
• Universal Input
• 3” x 5” footprint
• Low profile fits 1U applications
• EN61000-3-2 compliance
option (HCC)
• Overvoltage and short circuit
protection
• 65 W with free air convection
cooling
• EN55022, EN55011 conducted
emissions level B
• EN61000-4-2,-3,-4, -5, -6
immunity compliant
• RoHS compliant
• LPX80 enclosure kit available
• 2 year warranty
Safety
•
•
•
•
•
VDE0805/EN60950/IEC950
File No. 1040100-3336-0096
License No. 114404
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
China Compulsory
Certification 60950
*NLP65-76xx version only
Input
Input voltage range:
Universal input
(see Note 2)
NLP65-76xx version only
Input frequency range:
85-264 Vac
120-370 Vdc
47-63 Hz
Input current:
(cold start)
120 Vac
230 Vac
17 A max.
32 A max
Safety ground
leakage current:
120 Vac, 60 Hz
230 Vac, 50 Hz
0.7 mA
1.4 mA
Input current:
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
1.4 mA
0.51 A rms
1.40 A rms
0.80 A rms
Input fuse:
UL/IEC127
S3.15 A, 250 Vac In live and neutral
Total regulation:
(line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Rise time:
At turn-on
1.0 s, max
Transient response:
Main output
25% step
at 0.1 A/µs
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
Output
Temperature coefficient:
±0.02%/°C
Overvoltage protection:
Main outputs
125%, ±10%
Short circuit protection:
Cyclic operation
Continuous
Minimum output current:
Single and multiple
(See Note 6)
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
Rev.12.12.08_102
NLP65 Series
of 4
EMC Charateristics (11, 12)
Conducted emissions:
EN55022, FCC part 15
Level B
ESD air:
EN61000-4-2, level 3
Perf. criteria 1
ESD contact:
EN61000-4-2, level 4
Perf. criteria 1
Surge:
EN61000-4-2, level 3
Perf. criteria 1
Fast transients:
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3
Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3
Perf. criteria 2
Hold-up time:
120 Vac, 60 Hz
230 Vac, 50 Hz
16 ms @ 65 W
78 ms @ 65 W
Efficiency:
120 Vac, 65 W
72% typical
Isolation voltage:
Input/output
Input/chassis
3000 Vac
1500 Vac
General Specifications
Switching frequency:
Fixed
Approvals and standards: (see EN60950, VDE0805
Notes 9, 13)
IEC950, UL1950, CCC60950
CSA C22.2 No. 950
Weight:
283 g (10 oz)
100 kHz, ±5 kHz
MTBF demonstrated:
150,000 hours min
MIL-HDBK-217F
Environmental Specifications
Thermal performance:
Operating
(See derating curve)
0° C to +70 °C
(See notes 1, 3, 10)
Non-operating
-40 °C to +85 °C
50 °C - 70 °C ambient,
convection cooled
0 °C to 50 °C, ambient,
convection cooled
Derate to 50% load
DERATING CURVE
Output Power (Watts)
75W
20 CFM FORCED AIR COOLING
65W
65 W
NATURAL
CONVECTION
COOLING
0 °C to 50 °C, ambient
75 W
20CFM forced air (See Note 10)
Peak (0 °C to 50 °C, 60 s)
See table
Relative humidity:
Non-condensing
5 to 95% RH
Altitude:
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 5):
5-500 Hz
2.4 G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
0°C
38W
32W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
Embedded Power for
Business-Critical Continuity
Output
Voltage
Output Current
Ripple (4)
Total
Non-harmonic
Regulation (6)
Corrected
Max (1)
Peak (3)
Fan (10)
+5 V (IA)
7.5 A
9.1 A
8A
50 mV
±2.0%
+12 V (IB)
2.5 A
3.3 A
3A
150 mV
±5.0%
–12 V
0.65 A
0.81 A
0.8 A
120 mV
±5.0%
+5 V (IA)
7.5 A
9.1 A
8A
50 mV
±2.0%
+15 V (IB)
2.2 A
2.9 A
2.5 A
150 mV
±5.0%
–15 V
0.65 A
0.85 A
0.8 A
150 mV
±5.0%
+5 V
7.0 A
9.1 A
8.0 A
50 mV
±2.0%
+24 V
1.5 A
2.6 A
2.0 A
240 mV
±5.0%
+12 V
0.7 A
1.0 A
1.0 A
120 mV
±5.0%
+5 V (IA)
7A
9.1 A
8A
50 mV
±2.0%
+24 V (IB)
2A
2.6 A
2A
240 mV
±5.0%
+5 V (IA)
7A
9.1 A
8A
50 mV
±2.0%
+12 V (IB)
2.5 A
3.3 A
3A
150 mV
±5.0%
+5 V
10 A
13 A
12 A
50 mV
+12 V
5.4 A
7A
6.5 A
120 mV
+15 V
4.4 A
5.7 A
5.3 A
+24 V
2.7 A
3.5 A
3.5 A
Harmonic
Corrected
Ground
Pin (12, 14, 17)
NLP65-7608J
NLP65-9608J
NLP65-X608GJ
NLP65-7610J
NLP65-9610J
NLP65-X610GJ
NLP65-7620J
NLP65-9620J
NLP65-X620GJ
NLP65-7629J
NLP65-9629J
NLP65-X629GJ
±2.0%
NLP65-7605J
NLP65-9605J
NLP65-X605GJ
±2.0%
NLP65-7612J
NLP65-9612J
NLP65-X612GJ
150 mV
±2.0%
NLP65-7615J
NLP65-9615J
NLP65-X615GJ
240 mV
±2.0%
NLP65-7624J
NLP65-9624J
NLP65-X624GJ
Rev.12.12.08_102
NLP65 Series
of 4
NLP65-3322J(15)
Notes
1 Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65X610J must not exceed 62.5 Watts continuous output power with natural
convection. Model NLP65-X620J not to exceed 65 Watts continuous output
power with natural convection. Model NLP65-3322J must not exceed 60 Watts
continuous output power with natural convection.
2 When the input voltage is less than 90 Vac the operating temperature range is
0 °C to +40 °C. The ripple and regulation specifications may not be met.
3 Peak output current lasting less than 60 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
4 Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic
capacitor.
5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
Hz to 500 Hz.
6 A minimum load on the main output is required for proper start up. For
multiple outputs and single +5V output, the minimum load on the +5 V is
0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To
maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A.
7 For optimum reliability, no part of the heatsink should exceed 120 oC, and no
semiconductor case temperature should exceed 130 oC.
8 CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
9 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10 Maximum continuous output power for all multiple output models must not
exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling.
Model Numbering Options
1 The enclosure version includes: IEC connector, on/off switch, wire harness
output connector and fitted cover. To order, please add the suffix ‘E’ the model
number, e.g. NLP65-9608EJ. See NLP65 enclosure for details.
2 A Safety earth ground pin and ground choke are available as an option.
To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ.
3 To order an enclosure kit (unfitted), order the part number LPX80.
11 Conducted emissions testing were performed using the standard EN55022 setup with a stand alone NLP65 unit placed on a grounded metal plate with a line
choke on the AC input and ground wires (i.e. the wires are looped through an
EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’ AC
inlet with an integral line filter in the system chassis or to install a line choke
on the input wires as close as possible to AC entry point of the system chasssis.
Please contact the applications group for assistance with EMI compliance.
12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option.
J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6
is a ground choke and JP10 is a jumper. This option is intended for use in nonmetallic chassis applications where grounding is not possible via the mounting
screws. The ground choke is provided to assist system EMC compliance. When
performing conducted emissions testing on stand alone units, the ‘G’ option
is required to meet level B. To order simply add the suffix ‘G’ to the standard
model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for
both the PFC and non-PFC versions.
13 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in
the end use product.
14 The NLP65-9608J is available with an enclosure. To order an enclosed version,
see model numbering options below.
15 No PFC version, EN61000-3-2 is not applicable to this model.
16 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
17 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com.
Embedded Power for
Business-Critical Continuity
Americas
Mechanical Drawing
5.00
(127.00)
4.550
(115.57)
0.225
(5.715)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Rev.12.12.08_102
NLP65 Series
of 4
Europe (UK)
J1
3
N
1
L
J3
1
3.00
(76.20)
6
2.550
(64.770)
Asia (HK)
T1
J2
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
C19
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
Mounting
Hole Diameter
0.156 (4.00)
TOLERANCE: .xxx
.xx
0.005"
0.02"
ALL DIMENSIONS IN INCHES (mm)
Pin Connections
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
J2 (On ‘G’ Suffic Only)
Pin 1
Safety Ground
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower@
emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Input and Output
Connectors
Mating Connectors
AC (J1)
Molex 26-60-4030 type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals
DC (J3)
Molex 26-60-4060
Molex 09-50-3061 with Molex 2478 phosphor bronze crimp terminals or equivalent.
J1
Pin 1
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Note: The input and output connectors are the same as those used on NFS40, NFN40,
NAL40, NAN40 and NLP40.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Output Pin Connections
J3
SINGLE
DUAL
TRIPLE
Pin 1
V (A)
V (B)
V (B)
Pin 2
V (A)
V (A)
V (A)
Pin 3
V (A)
V (A)
V (A)
Pin 4
Return
Return
Return
Pin 5
Return
Return
Return
Pin 6
Return
N/C
V (C)
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2008
Emerson Electric Co.