ARTESYN
TLP150 MEDICAL SERIES
Single Output
Advanced Energy's Artesyn TLP150 series of open-frame
AC-DC power supplies comprises two single output models,
offering a main voltage of 12 V or 24 V. Each model also
provides 12 V fan and 5 V standby outputs. Both models
feature medical safety approvals and accept a universal input
of 85 to 264 VAC. Comprehensive overcurrent, overvoltage
and overtemperature protection is provided as standard.
Additional features include main output remote sense,
active current sharing and integrated control and monitoring
facilities. TLP150-M series power supplies provide 100 W of
output power with free air convection cooling and 150 W with
200 LFM of forced air. Less than 1U high, they are ideal for
systems that implement distributed power architectures (DPA)
and point-of-load (POL) schemes, as well as for powering
electromechanical devices and non-patient contact and
non-patient critical medical applications.
SPECIAL FEATURES
SAFETY
150 W on main channel with only
TUV EN60601-1, IEC60601-1
200 LFM
Total Power:
150 W
Input Voltage:
85 to 264 VAC
# of Outputs:
Single
VDE CB Certificate and Report
Low profile fits 1U applications
UL 62368-1
Active PFC and EN61000-3-2
UKCA Mark
compliant
DATA SHEET
Integrated control and monitoring
features
Overcurrent, overvoltage and
overtemperature protection
Compliance to EN55022-B
conducted noise standard
12 V fan output
5 V standby output (optional)
RoHS compliant
Two years warranty
©2022 Advanced Energy Industries, Inc.
TLP150M
ELECTRICAL SPECIFICATIONS
Input
Input voltage range
Universal Input
Input frequency range
85 to 264 VAC
47 to 63 Hz
Input surge current
264 VAC (cold start)
40 A max.
Safety ground leakage current
264 VAC, 50 Hz
150 μA
Input current
120 VAC @ 150 W
230 VAC @ 150 W
1.8 A rms
0.8 A rms
Input fuse:
UL/IEC127
T 3.15 A, 250 VAC
Output
Adjustment range
± 10%
Total regulation (line and load)
Main output
Auxiliary outputs
Fan output
± 3%
± 5%
± 10%
Turn-on delay
@120 VAC Input
2.0 s max..
Transient response
Main output
25% to 75%
step at 0.5 A/µs
5%
max. dev., 1 ms max.
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection
Main outputs
125%, ± 5%
Short circuit protection
Current limited
Continuous
Minimum output current
Singles
0A
Fan voltage output
See Note 9
12 V @ 0.5 A
Standby output
See Note 9
5 V @ 1.0 A
Conducted emissions
EN55022, FCC part 15
Level B
Harmonic current correction
EN61000-3-2
Compliant
ESD air
EN61000-4-2
Level 3
ESD contact
EN61000-4-2
Level 3
Radiated immunity
EN61000-4-3
Level 3
Fast transients
EN61000-4-4
Level 4
Surge
EN61000-4-5
Level 3
Conducted immunity
EN61000-4-6
Level 3
EMC CHARACTERISTICS (5)
2 advancedenergy.com
TLP150M
GENERAL SPECIFICATIONS
Hold-up time
850 VAC @ 60 Hz
20 ms @ 150 W
Efficiency
115 VAC @ 150 W
230 VAC @ 150 W
81% typ.
84% typ.
Isolation voltage
Input/output
Input/chassis
4000 VAC
1500 VAC
Weight
260 g (9.2 oz)
MTBF (@ 25 ºC)
Telcordia SR-332
MIL-HDBK-217F
900,000 hours min.
350,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient,
(See derating curve)
0 °C to +70 °C
Non-operating
-40 °C to +85 °C
0 °C to 50 °C ambient, 200 LFM forced air
150 W
0 °C to 50 °C ambient, convection cooled
100 W
50 °C to 70 °C ambient, convection cooled
Derate linearly to 50% load
Relative humidity
Non-condensing
5 to 95% RH
Altitude
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 7)
5 - 500 Hz
2.4 G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
advancedenergy.com
3
TLP150M
ORDERING INFORMATION
Output Voltage
Output Currents
Min
Max (free air)(1, 4)
Max (forced air) (2, 4)
Ripple
Total Regulation
Model Numbers (8, 10)
12 V
0A
8.4 A
12.5 A
120 mV
± 3.0%
TLP150N-99S12J
24 V
0A
4.2 A
6.3 A
240 mV
± 3.0%
TLP150N-99S24J
Notes:
1. Free air convection. Maximum continuous output power not to exceed 100 W. Refer to Figure 1 for the derating curve.
2. 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W.
3. Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 μF tantalum
capacitor and a 0.1 μF ceramic capacitor.
4. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed 115 °C
and no semi-conductor case temperature should exceed 120 °C.
5. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with radiated EMI
specifications may require mounting in a suitable enclosure.
6. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
7. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G.
8. Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output and/or remote ON/OFF control is required e.g. TLP150N-99S12FJ.
9. 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status.
10. T he ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
11. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com to find a
suitable alternative.
12. Power good signal required 100 mA load on the main output.
13. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not
intended for sale to End Users.
Outline Dimensions
DERATING CURVE Output Power (Watts)
5.000 (127.00)
4.550 (115.57)
150 W
200 LFM (1.0 m/s)
FORCED AIR COOLING
100 W
J1 1
1
FAN
Neutral
0W
J2
0C
10 C
20 C
30 C
40 C
50 C
60 C
70 C
1
J4
1
Live
R88
Ground/Earth
0.225 (5.72)
50 W
2.550 (64.77)
NATURAL CONVECTION COOLING
3.000 (76.20)
J3
75 W
Trimmer Adjust
Output Voltage
0.225 (5.72)
Figure 1: Derating Curve
ø0.156 (4 Places)
Dimensions in Inches (mm)
Figure 2: Mechanical Drawing
4 advancedenergy.com
1
J301
Total Height
1.250 (31.75)
TLP150M
CONNECTOR AND MATING CONNECTOR TYPES
Connector
Type
Mating Connector Type
J1
Molex 09-65-2038 (5273 series)
void pin 2 or equivalent
Molex 09-52-4034 (5239 series) or equivalent
Molex 08-52-0072 (2478 series) or equivalent crimp terminals
J3
Molex 09-65-2068 (5273 series)
or equivalent
Molex 09-52-4064 (5239 series) or equivalent
Molex 08-52-0072 (2478 series) or equivalent crimp terminals
J301
(Optional)
Leoco 2421P04H000 (2421 series)
or equivalent
Leoco 2420S04000 (2420 series) or equivalent
Leoco 2453TPB00V1 (2453T series) or equivalent crimp terminals
or
JST EHR-4 (EH series) or equivalent
JST SEH-001T-P0.6 (EH series) or equivalent crimp terminals
Fan
Molex 22-23-2021(6373 series)
or equivalent
Molex 22-01-3027 (2695 series) or equivalent
Molex 08-50-0113 (2759 series) or equivalent crimp terminals
PIN CONNECTIONS
J1 Pin Connections
Pin 1
Neutral
Pin 3
Live
J2 Tab Connections
Tan
Ground/Earth
advancedenergy.com
5
TLP150M
PIN CONNECTIONS (CONTINUED)
J3 Pin Connections
Pin 1
RTN
Main Return
Pin 2
RTN
Main Return
Pin 3
RTN
Main Return
Pin 4
Vo
+Main Output
Pin 5
Vo
+Main Output
Pin 6
Vo
+Main Output
Pin 1
-S
-Vo Remote Sense
Pin 2
DC OK
DC Power Good Signal
Pin 3
PW OK
Power Good
Pin 4
LS
Load Share Signal
Pin 5
+S
+Vo Remote Sense
Pin 6
SGND
Signal Common
Pin 1
5 Vsb
Standby Voltage
Pin 2
SGND
Signal Common
Pin 3
Reserved
Do Not Connect
Pin 4
PS OFF
Remote ON/OFF Signal
Pin 1
+ 12 V
Fan Voltage
Pin 2
+SGND
Return
J4 Pin Connections
J301 Pin Connections (Optional)
Fan Pin Connections
6 advancedenergy.com
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions for
mission-critical applications and processes.
Our products enable customer innovation in complex
applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and medical.
With deep applications know-how and responsive service
and support across the globe, we build collaborative
partnerships to meet rapid technological developments,
propel growth for our customers, and innovate the future
of power.
For international contact information,
visit advancedenergy.com.
powersales@aei.com (Sales Support)
productsupport.ep@aei.com (Technical Support)
+1 888 412 7832
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks
of Advanced Energy Industries, Inc.
ENG-TLP150M-235-01 4.20
很抱歉,暂时无法提供与“TLP150R-96S12FJ”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+1119.537411+144.52290
- 40+825.0070740+106.50150
- 国内价格 香港价格
- 1+1100.345341+142.04537
- 40+810.8640940+104.67576