UMP1T-S2E-S2D-S2L-S2L-35-A 数据手册
Embedded Power for
Business-Critical Continuity
µMP Series
Rev. 12.12.2013
µMP Series
1 of 6
MicroMP 1U Multi Output
Up to 1200 Watts
Total Power: Up to 1200 Watts
Input Voltage: 85 - 264 Vac
120-300 Vdc
# of Outputs: Up to 12
Special Features
• Full Medical EN60601 approval
• PMBus
• High efficiency
• Current limit modification
(foldback or constant current)
• High power density.
uMP4: 10.8 W/cu-in
uMP1: 15.1 W/cu-in
• Intelligent fan
(speed control/fault status)
• Downloadable GUI from website
• uP controlled PFC input with active
inrush protection
• Optional conformal coating
• Industrial temp range (-40 ºC to 70 ºC)
• No preload required
• Industrial shock/vibration (> 50G’s)
• Low cost
• IEC or terminal block input
• Low profile 1U size
Electrical Specifications
µMP4C shown
Input
Input range:
85 - 264 Vac, 120 - 350 Vdc (limited to 250 Vac/300 Vdc in medical apps)
Frequency:
47 - 440 Hz
Inrush current:
40 A peak max. (soft start)
Efficiency:
Up to 91% @ full case load
Power Factor:
0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz)
Turn-on time:
AC on 2 sec for uMP1 and 1.5 sec for uMP4, inhibit/enable 250 ms typical
EMI filter:
CISPR 22/EN55022 Level “B”
Leakage current:
300 µA Max. @ 240 VAC
Radiated EMI:
CISPR 22/EN55022 Level “B”
Holdover storage:
16.7 ms minimum (independent of input Vac, 0 °C to 50 °C))
AC OK:
Signal goes low indicating loss of AC input.
Hold up = Full cycle ride thru (50 Hz)
Harmonic distortion:
Meets EN61000-3-2
Isolation:
Meets EN60950 and EN60601
Global Inhibit/Enable: TTL, Logic “1” and Logic “0”; fan off when unit is inhibited
Input fuse (internal):
uMP1: 16 A/250 V TLAG, uMP4: 10 A / 250 V. (both lines fused)
Warranty:
2 years
Environmental Specifications
Operating temperature:
Safety
UL UL60950/UL60601-1
CSA
CSA22.2 No. 234 Level 5
VDE EN60950/EN60601-1
BABT Compliance to
EN60950/EN60601 BS7002
• CB
Certificate and report
• CE
Mark to LVD
• CCC
Approved
•
•
•
•
-40 ° to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C.
( -20 °C start up). Meets full spec after 1/2 load. 10 min warm-up
Storage temperature:
-40 °C to 85 °C
Electromagnetic susceptibility: Designed to meet EN61000-4; -3, -5, -6, -11 Level 3, Level 4 for -2, -4
Humidity:
Operating; non-condensing 10% to 95% RH
Vibration:
MIL-STD-810E
MTBF demonstrated:
> 350,000 hours at full load, one uMP4 case + two modules, Telcordia SR-332
calculated MTBF
Altitude:
Up to 10k feet; derate linear to 50% from 10k-30k feet
Embedded Power for
Business-Critical Continuity
Rev. 12.12.2013
µMP Series
2 of 6
Output
Factory set point accuracy: ± 1%
Margining:
± 3 - 7% nominal analog (single output module only)
Overall regulation:
0.4% or 30 mV which ever is greater.
Ripple:
RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz
Dynamic response:
< ± 5% or 250 mV, with 50% step load
Recovery time:
To within 1% in < 300 µsec
Reverse voltage protection: 100% of rated output current
All outputs disabled when internal temp exceeds safe operating range.
Thermal protection:
(OTP)
Remote sense:
Single wire parallel:
DC OK:
Minimum load:
Housekeeping standby:
p to 0.5 V total drop (not available on triple output module)
U
Current share to within 5% of total rated current
± 5% of nominal.
Not required
5 Vdc @ 1.0 A max. present whenever AC input is applied
Module inhibit:
Output/Output isolation:
Logic - output on with low or open. Different logic options available
> 1 Megohm, 500 V
Vout
Full load
(A)
OVP trip max
(V)
OCP trip typ (Iout%)
SCP trip max (Iout%)
Overshoot (max
mV)
Peak Deviation
(max mV)
40
40
40
2.00 V
5.96 V
6.31 V
130%
130%
130%
160%
160%
160%
150
250
250
± 250
± 250
± 250
36
36
30
5.76 V
9.00 V
10.80 V
130%
130%
130%
160%
160%
160%
250
250
300
± 250
± 250
± 300
25
20
16
10.80 V
15.60 V
19.50 V
130%
130%
130%
160%
160%
160%
300
600
750
± 300
± 600
± 750
13
10
8
15.60 V
31.20 V
39.00 V
130%
130%
130%
160%
160%
160%
600
1200
1500
± 600
± 1200
± 1500
7
5
4
36.40 V
62.40 V
78.00 V
130%
130%
130%
200%
160%
200%
1400
2400
3000
± 1400
± 2400
± 3000
3V3 Module
0.9
3.3
3.6
5 V Module
3.2
5
6
12 V Module
6
12
15
24 V Module
12
24
30
48 V Module
28
48
60
Case Line-Up
Case
Max Output
µMP4 - 4 Slot
400 W - 600 W
µMP1 - 6 Slot
1000 W - 1200 W
Dimensions
256.9±0.8 x 88.9±0.5 x 40.0±0.7
(10.11” x 3.5” x 1.57”)
256.9±0.8 x 127±0.5 x 40.0±0.5
(10.11” x 5” x 1.57”)
Connections
Max Current Amps
IEC/Terminal Block
9.91
IEC/Terminal Block
13.87
Output Module Line-Up
Output Range
(Vdc)
0.9 - 3.6
3.2 - 6.0
6.0 - 15.0
12.0 - 30.0
28.0 - 54.0
5.0 - 28.0
5.0 - 28.0
Max Current
(Amps)
Max Power
(Watts)
40
36
25
13
7
4
4
144
180
240
240
240
96
96
Module Codes
Standard Outputs
A, B, C, D - 2, 2.2, 3, 3.3
E, F, G, H - 5, 5, 2, 5.5, 6
I, J, K, L, M, N - 8, 10, 11, 12, 14, 15
O, P, Q, R, S - 18, 20, 24, 28, 30
T, U, V, W, X, Y - 28, 30, 33, 36, 42, 48, 54, 60
Dual Output Module. Each output is rated to 96W (192
Watts total). Wide range is adjustable.
Embedded Power for
Business-Critical Continuity
Rev. 12.12.2013
µMP Series
3 of 6
Ordering Info
Case Size
Case Option Codes
Module/Voltage/Option Codes
µMPXY
- S2E - DER -
DLL -
Module Codes
S2 = 200 W Single O/P (1 slot)
D = 96 W/96 W Dual O/P Common
Ground (1 slot)
I = 96 W/96 W Dual O/P Isolated
Ground (1 slot)
Case Size
Single - Phase Input where X =
4 = 1.57” x 3.5” x 10”; 400 W - 600 W, 4 Slots
1 = 1.57” x 5” x 10”; 1000 W - 1200 W, 6 Slots
Input Type where Y =
T = Terminal Block
C = IEC Connector, C14
B = IEC Connector, C16
Voltage Codes:
See Voltage Code Table
Slots in Parallel
Code
Slots in Parallel
Code
Slots in Parallel
Code
1
1&2
6
1,2&3
B
1,2&3; 4&5
0
2
3
4
2&3
3&4
4&5
7
8
9
1,2,3&4
1,2,3,4&5
1,2,3,4,5&6
C
D
E
1,2,3&4; 5&6
1&2; 3&4; 5&6
1,2&3; 4,5&6
5
5&6
A
1&2; 3&4
F
2&3; 4&5
Standard Output Ratings
Module Output
Voltage Code
Single Output ONE SLOT
240 Watts Max
Dual Output ONE SLOT
192 Watts Max
Module Identification
S2
D = Dual Common Ground
I = Dual Isolated Ground
Output Module Line-Up
2.0 V
2.2 V
3.0 V
3.3 V
5.0 V
5.2 V
5.5 V
6.0 V
8.0 V
10.0 V
11.0 V
12.0 V
14.0 V
15.0 V
18.0 V
20.0 V
24.0 V
28.0 V
30.0 V
33.0 V
36.0 V
42.0 V
48.0 V
54.0 V
60.0 V
Factory assigned
for modified
standards
Slots in Parallel
no module in
parallel
Application Notes
(Only for Output Voltages 14.0V-24.0V)
1. Units should not be operated in parallel
2. In a single unit, parallel modules should
not be
individually inhibited
3.Total load capacitance should not exceed
2000uF
Derating Curves - µMP1
Voltage Codes
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
* For “I” codes only
Factory assigned
for modified
standards
Second digit
0 = No Options
1 = Reverse Air
3 = Global Enable
5 = Opt 1 + Opt 3
Code
Volts
Hardware Code
00 -
A -
###
Case Option Codes
First digit
0 - F = Parallel Code
Parallel Codes
Code
Software Code
Output Current
V1
40.0
40.0
40.0
40.0
36.0
34.0
32.0
30.0
25.0
24.0
22.0
20.0
17.0
16.0
13.0
12.0
10.0
8.6
8.0
7
6.7
5.7
5.0
4.4
4.0
Output Current
V1
V2
N/A
N/A
N/A
4.0*
4.0*
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
3.4
3.4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Embedded Power for
Business-Critical Continuity
S2 Module
µMP4 (AC input on opposite side)
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
4
3
2
1
µMP4 =4 available slots
DC Output Control & Signals
(Single output)
J2
J1
Input
85-264 Vac
200-264 Vac
400 W max.
600 W max.
240 W
µMP1 (AC input on opposite side)
S
L
O
T
6
S
L
O
T
5
S
L
O
T
4
S
L
O
T
3
S
L
O
T
1
S
L
O
T
2
Rev. 12.12.2013
µMP Series
4 of 6
J2
1.0±0.25 V ADJ
5.3±0.5
J1
V+
Pin
1
2
3
4
5
6
7
8
9
10
Function
No connection
No connection
Current share
Module inhibit return
Module ISO inhibit
SCOM
-RMT sense
Margin
Remote margin / V prog.
+RMT sense
29.8±0.2
37.5±0.3
32.5±0.3
36.5±0.3
36.5±0.3
V-
µMP1 = 6 available slots
Input
85-264 Vac
1000 W max.
CAPS HEIGHT
4.5±0.3
12.5 MAX
3.0 MAX
200-264 Vac
1200 W max.
0.8 - 1.5
1.6±0.16
Pin Connectors
Figure 1. AC Input
AC Input
Pin
1
2
3
IEC Connector
Terminal Block
PE N L
9
10
Mates with
Landwin 2050S1000 Housing
2053T011V Pin
or
JST PHDR-10VS Housing
JST SPHD-002T-P0.5 (28-24)
JST SPHD-001T-P0.5 (26-22)
Connector Kit Part No.:
70-841-023
PFC Input Connector (control & signals)
Pin
1
2
3
4
5
6
7
8
9
Figure 2. Connector J1 & J2
1
2
J1
Function
AC neutral
AC line (hot)
Chassis (earth) ground
Function
Input AC OK - “emitter”
Input AC OK - “collector”
Global DC OK - “emitter”
Global DC OK - “collector”
Spare
Global inhibit/optional enable logic “1”
Global inhibit/optional enable logic “0”
Global inhibit/optional enable return
+5 VSB housekeeping
10 +5 VSB housekeeping return
J2
I2C Bus Output Connector
Pin
1
2
3
4
5
6
7
8
9
10
Function
5 Vcc bus
Serial data signal (SDA)
Secondary return (COM)
Serial clock signal (SCL)
Address bit 2 (A2)
No connection
Address bit 1 (A1)
No connection
Address bit 0 (A0)
No connection
1
2
130.0±1.5
9
10
Dual Module
DC Output Control & Signals
(Dual output)
Pin
1
2
3
4
5
6
7
8
9
10
Function
-RMT sense V2
+RMT sense V2
No connection
Module inhibit rtn
Module ISO inhibit
SCOM
-RMT sense V1
No connection
No connection
+RMT sense V1
Embedded Power for
Business-Critical Continuity
µMP Series
µMP4 (400/600 Watts Max)
Case Size: µMP4: 10.11” x 3.5” x 1.57” (256.9mm x 88.9mm x 40.0mm)
Weight: µMP4 Case: 1.96 lbs • Single O/P: 0.22 lb. • Dual O/P: 0.16 lb.
• Blank: 0.06 lb.
Rev. 12.12.2013
µMP Series
5 of 6
Forward Airflow
Notes:
1. Input: IEC 60320 C13 (for IEC connector)
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4-0.5 Nm); Wire: 12-16 AWG;
Wire Strip Length: 0.354" (9.0 mm)
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.
Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD-002T-PO.5 (JST) pins.
3. Output Module Connectors: All single O/P modules are M4 x 10mm screws; Max. Torque: 6.94 to 8.68 lb-in (0.785 to 0.981 N-m).
Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm); Control signal connector: Refer to Item 2.
4. Chassis Material: Steel with chemical film coating (conductive).
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m)
6. All dimensions are in millimeters and inches, and are typical.
Forward Airflow
Embedded Power for
Business-Critical Continuity
µMP Series
µMP1 (1000/1200 Watts Max)
Case Size: µMP1: 10.11” x 5” x 1.57” (256.9mm x 127mm x 40.0mm)
Weight: µMP1 Case: 2.78 lbs • Single O/P: 0.22 lb.
Americas
• Dual O/P: 0.16 lb. • Blank: 0.06 lb.
5810 Van Allen Way
Rev. 12.12.2013
µMP Series
6 of 6
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Forward Airflow
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Notes:
1. Input: IEC 60320 C13 (for IEC connector)
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in
(0.4-0.5 Nm); Wire: 12-16 AWG; Wire Strip Length: 0.354" (9.0 mm)
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.Mates with housing
2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and
SPHD-002T-PO.5 (JST) pins.
3. Output Module Connectors: All single O/P modules are M4 x 10mm screws;
Max. Torque: 6.94 to 8.68 lb-in (0.785 to 0.981 N-m).
Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm);
Control signal connector: Refer to Item 2.
4. Chassis Material: Steel with chemical film coating (conductive).
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm);
Max. Torque: 8.85 lb-in (1.0 N-m)
6. All dimensions are in millimeters and inches, and are typical.
Forward Airflow
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson and the Emerson Network Power
logo are trademarks of Emerson Electric Co.
©2012 Emerson Electric Co.
All rights reserved.