Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
1 of 7
VRM64 Series
Single Output
Input Voltage: 12 Vdc
# of Outputs: Single
Special Features
• Meets AMD64 Processor
specification
• Allows dynamic VID code
changes
• 5 Bit VID input
• 0.8 Vdc to 1.55 Vdc in
25 mV steps
• Up to 100 A/µs load transient
• Differential remote sense for
improved load regulation
• Vertical plug-in to standard
motherboard connector with
or without retention latch
• Output current up to 80 A
continuous
• Open collector power good
signal
• Monotonic turn-on and
turn-off
• Fused input
• SMBus interface
• Available RoHS compliant
• 2 Year Warranty
Electrical Specifications
Output
Voltage adjustability:
See VID codes, Table 3
Output current:
Votlage setting accuracy:
0.8 - 1.55 Vdc
80 A
20 MHz bandwidth
± 0.8%
Ripple and noise:
(See Notes 1, 2)
Short circuit protection:
(See Note 7)
50 mV pk-pk
Remote sensing compensating
voltage:
Up to 300 mV max
Continuous current limit, default
setting as trip
Input
Input voltage range:
12 Vin nominal
10.8 - 13.2 Vdc
Input current:
Operation
No load
Remote OFF
12.54 A max.
1.1 A max.
45 mA max.
UVLO:
Turn ON voltage
Turn OFF voltage
Hysteresis
10.5 V typ.
9.8 V typ.
0.65 V typ.
Start-up time:
Nominal line
10 ms max.
Enable
Logic compatibility
ON
OFF
Ref. to -input
> 1.7 Vdc
< 0.8 Vdc
+5_ALWAYS
Current demand
250 mA typ.
Embedded Power
Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
2 of 7
Specifications
Unless otherwise stated, all specifications are typical at nominal input, maximum continuous rated load at
25 °C and voltages are referenced to Vin-.
General Charateristics
Efficiency:
1.5 V output @ 60 A
84% typ.
Switching frequency:
Fixed (See Note 4)
830 kHz
Material flammability:
UL94V-0
Weight:
< 52 g (< 2 oz)
MTBF:
Telcordia SR-332
> 2,000,000 hours
Mating connector:
(See Table 1 for pin out)
Connector fingers:
Tyco/Elcon
283-0172-01303
Gold plated, 30 µ-inches
Environmental Specifications
Maximum temperature shock: Operating
5 °C/10 min.
Temperature shock:
Operating
Non-operating
10 °C/hour
20 °C/hour
Humidity:
(Non-condensing)
Operating
Non-operating
85% RH
95% RH
Altitude:
Operating
Non-operating
10,000 feet max.
50,000 feet max.
Shock:
Operational and non-operational
30G 11 ms Half sine wave
Vibration:
(See Note 8)
Operational and non-operational
0.02 G2/Hz max.
Electrostatic discharge:
IEC61000-4-2
(See Note 6)
Indirect air
Indirect contact
15 kV
8 kV
Thermal performance:
(See Note 5)
Operating ambient temperature
Non-operating
0 °C to +60 °C
-40 °C to +100 °C
Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
3 of 7
Ordering Information
Input
Voltage
Output
Voltage
OVP
12 Vdc
0.8 - 1.55 Vdc
12 Vdc
0.8 - 1.55 Vdc
Output Current
Min
Max
Efficiency
(typ)
2.2 Vdc
0A
80 A
84%
50 mV
VRM64-80-12-UY
2.2 Vdc
0A
80 A
84%
50 mV
VRM64-80-12-UJ
Pin Connections
Regulation
Load
Model Numbers (10, 11)
Voltage Identification (VID) Codes
Pin No.
Function
Pin No.
Function
VID4
VID3
VID2
VID1
VID0
VDAC
1
GND
54
+12 Vin
1
1
1
1
1
Off
2
GND
53
+12 Vin
1
1
1
1
0
0.800
3
GND
52
+12 Vin
1
1
1
0
1
0.825
4
VID4
51
VID3
1
1
1
0
0
0.850
5
VID2
50
VID1
1
1
0
1
1
0.875
6
VID0
49
Current Share
1
1
0
1
0
0.900
7
COREFB H
48
COREFB L
1
1
0
0
1
0.925
8
PWRGD
47
CBOUT
1
1
0
0
0
0.950
9
Enable
46
ADD 0
1
0
1
1
1
0.975
10
SMDA
45
ADD 1
1
0
1
1
0
1.000
11
SMCL
44
-VRMPRES
1
0
1
0
1
1.025
12
SGND
43
+5 V_always
1
0
1
0
0
1.050
13
VDD Core +
42
VDD Core +
1
0
0
1
1
1.075
14
VDD Core +
41
VDD Core +
1
0
0
1
0
1.100
15
VDD Core +
40
VDD Core +
1
0
0
0
1
1.125
16
GND
39
GND
1
0
0
0
0
1.150
17
GND
38
GND
0
1
1
1
1
1.175
18
GND
37
GND
0
1
1
1
0
1.200
19
VDD Core +
36
VDD Core +
0
1
1
0
1
1.225
20
VDD Core +
35
VDD Core +
0
1
1
0
0
1.250
21
VDD Core +
34
VDD Core +
0
1
0
1
1
1.275
22
VDD Core +
33
VDD Core +
0
1
0
1
0
1.300
23
VDD Core +
32
VDD Core +
0
1
0
0
1
1.325
24
VDD Core +
31
VDD Core +
0
0
1
1
1
1.350
25
GND
30
GND
0
0
1
1
1
1.375
26
GND
29
GND
0
0
1
1
0
1.400
27
GND
28
GND
0
0
1
0
1
1.425
0
0
1
0
0
1.450
0
0
0
1
1
1.475
0
0
0
1
0
1.500
0
0
0
0
1
1.525
0
0
0
0
0
1.550
Table 1: Pin Connections
Table 2: Voltage Identification (VID) Codes
Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
4 of 7
Signal Electrical Interface
Characteristic - Signal Name
Symbol
MIN
MAX
UNITS
ENABLE - on
ENABLE (on)
1.7
5.5
V
No pull up resistor provided by the VRM
ENABLE - off
ENABLE (off)
-0.3
0.8
V
No pull up resistor provided by the VRM
PWRGD - high
VPWRGD (high)
1.7
V
No pull up resistor provided by the VRM
PWRGD - low
VPWRGD (low)
-0.3
V
Open-collector output to not more than
5.5 V, max current 5 mA
PWRGD - low threshold
PWRGD - turn-on response to
ENABLE going high
TYP
0.8
150
Trise
2
VID - high
Vih (VID)
VID - low
Vil (VID)
2.5
mV
10
ms
1.7
5.5
V
-0.3
0.8
V
OVP1 (See Note 7)
2.2
V
OVP2 (See Note 7)
133
%
4
V
OVP drive voltage
CB_ OUT
NOTES AND CONDITIONS
Below VID setting
For waveforms, refer to Application
Note 185
Default setting is trip. At OVP1 or OVP 2
whichever is smaller
Of VID Setting
SMBus Address high
ADD_ x (high)
3.8
V
SMBus Address low
ADD_ x (low)
-0.3
0.7
V
SMBus Data high
SMDA (high)
2.1
5.5
V
SMBus Data low
SMDA (low)
-0.3
0.8
V
Symbol
MIN
MAX
UNITS
ESD - Indirect air
15
kV
EN61000-4-2
In end user equipment
ESD - Indirect contact
8
kW
EN61000-4-2
In end user equipment
Electromagnetic Compatibility
Characteristic - Signal Name
Input characteristics
Input current - operating
Input capacitance - external bypass
Notes:
IIN
CINext
TYP
12
A
1600
µF
1 Recommended output capacitance, 48 x 22 µF ceramic MLCC.
2 50 mV pk-pk ripple. Vin = 12 V, Vout = 1.5 V, Iout = 80 A.
3 With the recommended capacitors (See Note 1) across the output, the output
voltage stays within the load regulation window for all loads and transient
events, up to 80 A. It will also allow instantaneous VID-on-the-fly changes of up
to 500 mV at 80 A.
4 VRM64 uses a five phase buck topology. Each phase switches at
830 kHz. This gives an equivalent switching frequency of 4.2 MHz
5 Maximum current requires adequate forced air over the converter. Please
consult Figure 1 for thermal derating.
6 When the VRM detects an output over-voltage event, the OVP pin
transitions to logic high. This signal can be used to shut down the supply to
the VRM, or drive an external crowbar device.
NOTES AND CONDITIONS
VIN = VIN (typ)
Iout (cont.) = 80 A, VID = 1.5 V
7 These are default settings. The current limit may be set to ‘trip’ or
‘hiccup’. The output overvoltage limits, input overvoltage and undervoltage
settings, the output droop and offset, the current limit setpoint and many
others can be changed by component changes. Please consult the factory for
details.
8 0.01 G2/Hz from 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz,
all axes.
9 In accordance with AMD requirements, PWRGD will go high at least 2 ms after
VDD settles within specifications.
10 The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free)
compliant. Pb-free (RoHS 6/6) compliant versions are “J” suffix.
11 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com to find a suitable alternative.
Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
5 of 7
0
60
50
600LFM (3m/s)
500LFM (2.5m/s)
40
400LFM (2m/s)
300LFM (1.5m/s)
30
20
40
50
60
70
80
90
OUTPUT VOLTAGE (V)
TEMPERATURE (ºC)
70
-5
-10
-15
-20
-25
100
OUTPUT CURRENT (A)
11 Vin
12 Vin
13 Vin
0 10 20 30 40 50 60 70 80 90 100 110
OUTPUT CURRENT (A)
Figure 2: Load Regulation
Figure 1: Typical Thermal Derating At Sea Level
(12 Vin, 1.5 Vout)
EFFICIENCY (%)
86
84
11 Vin
12 Vin
13 Vin
82
80
78
40
60
80
100
OUTPUT CURRENT (A)
Figure 3: Typical Efficiency Vs Load
Figure 4: Output Ripple and Noise
10 mV Per Square, 2 µs Per Square
Embedded Power for
Business-Critical Continuity
Rev.11.21.12_64
VRM64 Series
6 of 7
Figure 5: Mechanical Drawing
Embedded Power for
Business-Critical Continuity
Americas
Rev.11.21.12_64
VRM64 Series
7 of 7
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson and the Emerson Network Power
logo are trademarks of Emerson Electric Co.
©2012 Emerson Electric Co.
All rights reserved.
很抱歉,暂时无法提供与“VRM64-80-12-UY”相匹配的价格&库存,您可以联系我们找货
免费人工找货