3453 DIGITAL MΩ HiTESTER
Field measuring instruments
125 V/
40MΩ
250 V/2000 MΩ 500 V/2000 MΩ 1000 V/4000 MΩ
4
ranges
Insulation resistance measurement
Actual-size
For general-purpose measurement
Insulation resistance, AC voltage, low resistance (continuity) measurement
http://www.hioki.co.jp/
HIOKI company overview, new products, environmental considerations and other information are available on our website.
For efficient insulation measurement!
Myriad functions for various measurement needs. Accurate
digital display
Ve r s a t i l e
Test voltage
uses in the field
Moving-average processing (averaging for two seconds) suppresses dispersion of display, ensuring more accurate and stable measurement. The logarithmic scale bar graph display from 0 to 4000 MΩ offers the feel of an analog meter. The bar graph displays the voltage level of the object being measured, showing either that the object is at a line voltage or how the object discharges after being charged during measurement.
Back-lighting liquid crystal display enables reading in dark areas.
q Insulation measurement through sight and sound! The reference value is set separately for each measurement range.
Reference value (MΩ)
125 V 0.1 / 0.2 / 1 / 2 /3 / 5 / 10 / 20 250 V/500 V 0.1 / 0.2 / 0.4 / 1 / 2 / 3 / 5 / 10 / 20 / 30 / 50 / 100 / 200 / 500 / 1000 / 2000 1000 V 1 / 2 / 3 / 5 / 10 / 20 / 30 / 50 / 100 / 200 / 500 / 1000 / 2000
q Memorizes on the spot! (Memorizes up to 20 data points.) q Recognizes variations of resistance! Automatically displays the resistance value at one minute after commencing measurement . q Ability to measure AC voltage and low resistance (continuity)! Optional 9185 TEST LEADS feel like conventional testers. q Improved safety A line voltage warning lamp blinks when the voltage exceeds about 40 V.
s 3453 specifications
Insulation test voltage
Measurement range*1 First effective range
Accuracy at 23˚C±5˚C (73˚F±9˚F), 90 % rh or less
125 V DC
250 V DC
500 V DC
1000 V DC
Insulation resistance
Second effective range Accuracy Voltage with no load Min. resistance measurement value*2 Short circuit current Response time
4.000 / 40.00 MΩ 4.000 / 40.00 / 400.0 / 2000 / 4000 (1000V range only) MΩ 0.100 to 10.00 MΩ 0.200 to 20.00 MΩ 0.200 to 50.00 MΩ 0.200 to 999 MΩ 0 to 0.099 MΩ 0 to 0.199 MΩ 0 to 0.199 MΩ 0 to 0.199 MΩ 10.01 to 40.00 MΩ 20.01 to 2000 MΩ 50.01 to 2000 MΩ 1000 to 4000 MΩ First effective range: ±2%rdg. ±3 dgt. Second effective range: ±2 %rdg. ±6 dgt. (0 to first effective range), ±5 %rdg. ( more than first effective range) Not more than 1.2 times rated measurement voltage 0.125 MΩ 0.250 MΩ 0.500 MΩ 2.000 MΩ 0.6 mA max.
1.2 mA max. ∞ to center, ∞ to 0 MΩ within 5 s (within accuracy range)
Low resistance
(continuity)
Measurement range: 0 to 400.0 Ω, aural warning below 30 Ω Accuracy: ±2% rdg. ±8dgt. Open terminal voltage: 4 V max. Response time: 2 s max. Measurement range: 0 to 600 V Accuracy: ±2% rdg. ±8dgt. Frequency range: 50 to 60 Hz Input impedance: 170 kΩ
*1. Measurement range shifts automatically. *2. Resistance value to maintain rated voltage.
AC voltage
qFunctions: Insulation resistance mode; comparator, memory (20 data), measurement value hold, auto discharge, bar graph display (measure switch ON: insulation resistance; measure switch OFF: voltage across measurement terminals), auto display of measurement value 1 minute after measurement start, other measurement modes, live wire warning (when voltage of 40 V±20 V exists across measurement terminals), battery indicators, auto power save qDisplay: semi-transparent LCD, "4000" count, with backlight, bar graph 30 dots qDisplay update rate: 2 times / second q Load protection: 10 s: 600 Vrms (AC V range 720 Vrms) qSafety standard: EN61010-1 measurement category III 600 V qEMC standard: EN61326-1 qAmbient temperature range for use: 0 to 40˚C (32˚F to 104˚F), 90 %rh or less (no condensation) qAmbient temperature range for storage: -20 to 50 ˚ C ( - 4 ˚ F to 122 ˚ F) , 90 %rh or less (no condensation) qPower source: R6P manganese battery ✕ 4 or LR6 alkaline battery ✕ 4 qDimensions and Mass: Approx. 155 (6.1" ) W ✕ 98 (3.9" ) H ✕ 80 (3.2" ) D mm; Approx. 500 g (17.7 oz.) (with display cover attached)
Accessories
Store test probe. Lead length approx. 1.2 m (47.2")
9294 TEST PROBE
Display cover
The body is stackable during measurement.
Options
90 mm (3.54")
3453 DIGITAL MΩ HiTESTER
(All include 9294 TEST PROBE, display cover and suspension band)
Lead length approx. 1.2 m (47.2")
*
9288 BREAKER PIN
To be attached on the top of 9294 (Red)
9289 TEST PROBE
DISTRIBUTED BY
HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com
Shanghai Representative Office : 1704 Shanghai Times Square Office 93 Huaihai Zhong Road Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: info@hioki.cn
All information correct as of Dec. 22, 2004. All specifications are subject to change without notice.
3453E6-4ZE-02K
Printed in Japan
很抱歉,暂时无法提供与“3453”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+3.45947
- 30+3.33413
- 100+3.08344
- 500+2.83275
- 1000+2.70741
- 国内价格
- 100+0.00427
- 500+0.004
- 1000+0.00361
- 5000+0.00308
- 10000+0.00277
- 国内价格
- 100+0.00437
- 500+0.00411
- 1000+0.00372
- 5000+0.0032
- 10000+0.00288
- 国内价格
- 100+0.00393
- 500+0.00369
- 1000+0.00332
- 5000+0.00283
- 10000+0.00253
- 国内价格
- 100+0.00396
- 500+0.00371
- 1000+0.00334
- 5000+0.00285
- 10000+0.00256
- 国内价格
- 50+2.84665
- 500+2.54382
- 5000+2.34193
- 10000+2.24098
- 30000+2.14004
- 50000+2.07947