    3554 - BATTERY HiTESTER - ASM GmbH

  • 数据手册
  • 价格&库存
3554 数据手册
BATTERY HiTESTER 3554 Field Measuring Instruments Get a Complete Diagnosis of UPS Batteries with a Single Device Auto-hold and Auto-data storage uto-hold and Auto-data storage Enhanced resistance against noise nhanced resistance against noise Store up to 4800 sets of data tore up to 4800 sets of data PC Interface Interface User-exchangeable probe tip ser-exchangeable probe tip WIDE 60V RANGE I d e a l f o r UP S B ack u p B a t t er ie s The New Standard for Assessing Deterioration of Lead-acid Batteries Repeated recharging of a secondary battery can lead to battery deterioration and increase its internal resistance. Problems can intensify when there is a short-circuit in the internal cell leading to voltage drop, overheating and complete battery malfunction. Worst of all, these problems can cause life-threatening fires and other accidents. 2 HANDS FREE Data Capture Allows You to Focus on the Testing Toggle between 4 different ways to save data F ul ly Dat Auto m aC apt atic Automatically save d ata as ur e AUTO HOLD & AUTO MEMO soon as reading is stabilized TEST & SAVE AUTO MEMO Inst ant aneously s ave measurement data with one touch using the Remote Control Switch 9466 s addled to the test lead Press the HOLD t hen M EMO k eys whenever you need to save data Save up to 4800 Sets of Battery Data Check stabilized measurement value before saving with the Remote Control Switch 9466 AUTO HOLD Quickly Download Data to a PC via USB Interface - Effortlessly Manage Using Bundled Software The hassle-free measurement process is extended to data management and processing using the bundled data management software. All 4800 sets of data can be uploaded to the PC quickly and effortlessly via a USB cable, and displayed neatly in table format. Edit comparator tables and send them back to the 3554. Store and edit up to 200 sets of comparator settings Pencil and Paper Not Required Automatically clear data from the 3554 USB Edit and Send Comparator Settings Download: ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Data Memory Number Range Resistance value Resistance limits Voltage value Voltage limit Temperature Judgement Date & time Download Data to a Spreadsheet 3 Tough Against Noise Plus Wide 60V Range Trying to measure UPS backup batteries while they are still being used naturally brings about noise com- Three-rank rating of battery state: ing from the battery's inverter or rectifying circuit. The enhanced measurement current in the 3554 Pass, Warning or Fail plus fortified circuit design, added with the Averaging Function to handle batteries that have fluctuating measurement values no matter how steady you hold the probe makes the battery tester extra resistant against the adverse effects of noise. Assessment is based on a 6-way combination of comparisons against upper and lower resistance limits and a voltage threshold. Immediately see the judgement result on the bright LCD and beep on your choice of PASS or WARNING/FAIL. Resistance VOLTAGE Low Pass Warning In Range Warning Warning High Fail Fail Second resistance limit Voltage threshold value High Low First resistance limit ✓ Common battery cells: 0 to 12V DC ✓ Fork lifts and electric vehicles: 48V DC 60VDC maximum between terminals 10 Hours of Save time and money Continuous with an Operation uninterrupted workflow Wide Selection of Tough and Versatile Test Probes Sta nd essory Acc rd a The standard Pin Type Leads 9465-10 with the single test pin on each lead has been fortified to withstand even the toughest use, while a new dual-axis mechanism incorporated in the new Pin Type Lead 9772 allows the TWO pins in each test lead to move independently. Just in case of breakage, the pins on both the 9465-10 and the 9772 can be replaced easily on site. 13.5 φ 2.9 φ 1.27 φ 2.7 1 Strengthened Test Pin Optional Ac ce 9.15 Maximum jaw diameter: φ 15mm Clip Type Lead with • 1.7m between connector and Temperature Sensor junction 9460 • 25cm between junction and probe tip L arge Clip Type Leads 9467 • 85cm between connector and junction • 25cm between junction and probe tip • Maximum jaw diameter: φ29mm y or ss φ 1.8 Pin Type Lead 9465-10 (standard accessory) • 1.6m between connector and junction • 25cm between junction and probe tip Dual Pins/ Dual Axes 2.5 4.3 Pin Type Lead 9772 • 1.6m between connector and junction • 25cm between junction and probe tip φ 29 mm Remote Control Switch 9466 Diagonal probing is no longer a problem. • 2m between connector and junction Zero Adjustment Board 9454 (standard accessory) The Advantages of 4-Terminal Measurement The Quality of Your Test Lead CAN Make a Difference When measuring certain batteries such as leadacid cells, the resulting measurement value may differ depending on the test leads used to conduct the measurement. This difference is due to the shape of the probe tip as well as the dimensions of the 4-terminal test leads used for measurement. However, despite a difference in value given by different test leads, it is safe to assume that each specific value reflects the correct value obtainable by the respective test leads. Based on this principle, when diagnosing battery deterioration in a time series, it is particularly important to use test leads having the same tip shape and dimensions in order to maintain measurement consistency. T he dif fe r e nc e in t he me asur e me nt value s o b t a i n e d b y d i f f e r e n t t e s t l e a d s i s a p hy s i c a l phenomenon caused by the difference in distance between the SOURCE and SENSE pins of the test leads. This is more significant when the battery terminal contains a resistance higher than the internal resistance of the battery under test. The figure on the right demonstrates how even minute physical differences between the SOURCE and SENSE pins for two types of test leads can affect the detected voltage level of the battery. ( Pin to Sheath: 0.65mm ) 9465-10 ( Pin to Pin: 2.5mm ) 9772 + Battery + Battery Equivalent electric potential curve Electric potential slope A B V(Detected Voltage): A > B 4 ■ Specifications Basic Specifications Measurement items : Resistance (AC four-terminal method), voltage, temperature (platinum temperature sensor, only when using 9460 leads) : LCD Dimensions and mass Accessories : Approx.192W x 121H x 55D mm, 790 g (including batteries) : PIN TYPE LEAD 9465-10 x 1, USB cable x 1, Application Software CD x 1, Strap x 1, Carrying case x 1, Zero adjustment board x 1, LR6 alkaline batteries x 8, Fuse x 1 Display LCD All Segments Displayed Sampling rate Averaging Function Input overflow Constant current fault detection Open-circuit terminal voltage Auto power off Comparator Settings : : : : Once per second OFF, 4, 8, or 16 times [OF] is displayed [----] is displayed The standard 3554 Package comes bundled with one Pin type Lead 9465-10, one USB Cable, data management PC software, tough carrying case, zero-adjustment board, eight AA batteries, and one spare fuse. : 5 VMax : Auto power off after 10 minutes unless during data transmission : First and second resistance limits, and lower voltage limit Functions HOLD : (1) Pressing the HOLD key (2) Inputting signals to the EXT.HOLD/MEMO terminal (3) Stabilizing measured values (when the auto-hold feature is on) : While the measured values are being held, pressing MEMO key will save them to internal memory. When the auto-memory feature is on, measured values will be saved to the instrument's internal memory when held. Saved items: D ate, time, resistance value, voltage value, temp er ature, c o mpar ato r s et t ing value s, an d c o mpar ato r judgement. M aximum storable data: 4 800 sets. Memory structure: 400 data sets per unit (12 units) : Read stored data on instrument or with PC application : USB : Windows compatible, using USB interface PC to 3554: transfer comparator tables edited on Excel, delete data from 3554, initialize the 3554, make clock settings. 3554 to PC: transfer data stored in memory (save files on PC in CSV format) Number of Comparator : 200 Sets Settings Comparator Output : LCD display of PASS, WARNING, or FAIL. Select beeper to sound on PASS/WARNING or FAIL. Operating temperature : 0 to 40°C (32°F to 104°F), 80% rh or less (no and humidity condensation) : 60V DC, No AC input allowed Absolute maximum input voltage : Between input terminals and output terminals ( including Withstand voltage EXT. HOLD/MEMO, and USB terminals): 1.5 kV AC rms for 15 seconds Maximum rated power : 2 VA consumption Continuous operating : Approx. 10 hours (When using alkaline batteries; may time vary depending on conditions of use) Power supply : AA (LR6) Alkaline Batteries x 8 Data Storage Reading data PC Interface PC Software Application Measurement Accuracy (Guaranteed Accuracy Period: 1 Year) Guaranteed Accuracy Conditions : 23 °C± 5 °C (73°F± 9°F), non-condensating, after zeroadjustment, warm-up time not required Voltage Measurement Temperature coefficient : ±0.005 %rdg. ±0.5 dgt./ °C Range 6V 60 V Max. display ±6.000 V ±60.00 V Resolution 1 mV 10 mV Accuracy ±0.08 %rdg. ±6 dgt. Resistance Measurement Temperature coefficient : ±0.01 %rdg. ±0.8 dgt./ °C Measurement current frequency : 1 kHz ±30 Hz Measurement current reliability : ±10 % Range 3 mΩ 30 mΩ 300 mΩ 3Ω Max. display Resolution Measurement Current 3.100 mΩ 31.00mΩ 310.0 mΩ 3.100 Ω 1µΩ 10µΩ 100µΩ 1 mΩ 150 mA 150 mA 15 mA 1.5 mA Accuracy ±1.0 %rdg.±8 dgt. ±0.8 %rdg. ±6 dgt. Temperature Measurement Measurement Range 10°C to 60 °C Resolution 0.1°C Accuracy ±1.0°C To Our Valued Customers: The thresholds for determining the pass/fail condition of a battery depends on the specifications and standards of the battery manufacturer, battery type, capacity, etc. It is important and necessary to always conduct battery testing against the internal resistance and terminal voltage of a new or reference battery. In some cases, it may be difficult to determine the deterioration state of sealed lead acid batteries which demonstrates smaller changes in internal resistance than traditional open type (liquid) lead-acid or alkaline batteries. ■ Options Bundled with the standard 3554 Pin-type Lead 9465-10 Zero Adjustment Board 9454 Clip-type Lead with Temperature Sensor 9460 Pin-type Lead 9772 Remote Control Switch 9466 Large Clip Type Lead 9467 (no CE mark) Tip Pin 9465-90 (to replace the tip on Model 9465-10) Tip Pin 9772-90 (to replace the tip on Model 9772) DISTRIBUTED BY HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: info-sh@hioki.cn HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com Guangzhou Rep. Office : Room 303, Profit Plaza,No.76, West Huangpu Road, Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.cn Beijing Rep. Office : A-2602 Freetown, 58 Dong San Huan Nan Road, Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: info-bj@hioki.cn 3554E4-75E-03P Printed in Japan All information correct as of May. 31, 2007. All specifications are subject to change without notice.

很抱歉,暂时无法提供与“3554”相匹配的价格&库存,您可以联系我们找货

免费人工找货