MEMORY HiCORDER 8870-20
Recorders
Easy recording anytime, anywhere!
Hioki's traditional MEMORY HiCORDER functions are now condensed into a lowprofile, turn-key device. The compact design includes a beautiful wide-screen QVGA-TFT LCD. Easy to use, with great functionality and performance, you will want to keep this extraordinarily compact MEMORY HiCORDER close to hand. ■ Compact and easy to carry ■ Easy, intuitive operation ■ Simple PC connection ■ Fast, 1MS/second performance despite the compact size ■ Built-in, compact-yet-sharp QVGA-TFT wide LCD
Palm-size but Powerful
2
High performance instrument that fits in your hand
Ultra compact, yet easy to use
Actual Size
The “Settings Navigator” function guides operations
Activate the Settings Navigator Real-Time waveform monitoring
When powered on, the Settings screen appears along with the waveform monitor, and the new Settings Navigator blinks. By activating the Settings Navigator, you can easily navigate by following the simple instructions. Soon you will be operating the device like a seasoned professional.
The help text crawls along the bottom of the screen, describing the function of the setting at the blinking cursor. The enhanced “Waveform Monitor” window with level meter display facilitates changes to settings by simultaneously displaying real-time input waveforms.
3
Acquire and store data on a CompactFlash card for analysis on a personal computer
Simple, intuitive operation
The 8870-20 feels like a hand-held tester, yet takes waveform snapshots. It has no complicated functions - allowing you to observe waveforms quickly and increasing your work efficiency. ■ Easily make settings while viewing levels on the Settings screen. ■ Observe waveforms using only simple memory recorder functions.
Easy connection to a PC
Connect to a PC with the supplied USB cable to easily download data that has been automatically saved to a CF card. Use the supplied dedicated application program to display and print waveforms on the PC. ■ Easy USB 2.0 data transfer ■ D edicated application program for displaying and printing waveforms
Note: The CF card installed in the HiCORDER appears as a removable disk on the PC, but communication functions such as the capability to change HiCORDER settings from the PC are not available.
Isolated inputs for safe measurements
Isolated analog channel inputs provide CAT II overvoltage protection safety for measurements of up to 300 V AC and DC (maximum terminal-to-ground rating). This capability e n a b l e s s a f e s i m u l t a n e o u s vo l t a g e measurements of inverter primary and secondar y and stacked bat ter y cells without damaging the instrument. ■ 3 00 V isolation between measurement terminals and HiCORDER chassis ■ 3 00 V isolation between measurement terminals
Floating Voltage
Compact, easy-to-carry design
Volume and weight have both been reduced by 60% from HIOKI's previously most compact MEMORY HiCORDER, the 8807-01, to just 40% the volume and 55% the weight. Easily pack it in your briefcase to accompany you wherever you go. ■ O nly 176 mm wide, 101 mm high and 41 mm thick ■ Weighs only 600 g even with the battery pack installed
Waveform display and printing, and CSV conversion with PC
Either off-line, or via USB 2.0, easily copy data to a PC. Open a data file with the dedicated Wave Processor (PC application program) for the 8870-20, to import and print waveforms with your Data is simply saved to a CF card. When the HiCORDER is connected to a PC via USB 2.0, the data is quickly copied from the installed card to the PC: 20,000 waveform screen divisions transfer in about 20 seconds. own arrow and figure annotations. Of course, screen data c an be copied and pasted into common Word and Excel documents to easily create reports.
4
Portable size for on-site jobs
Catering to a multitude of applications
Sequential control fault analysis
Momentary supply dropouts and low AC voltage are often found to be causes of abnormal interruptions and warnings from sequentially controlled devices in factory production and testing lines. For optimal operational analysis, specify an abnormal power event as a trigger and simultaneously record waveforms of associated sequential relay signals, AC power and DC voltage systems.
CB timing measurements
Analyze the relationships of multi-point logic signals and analog waveforms to detect timing issues that can affect power supply circuit breakers. Use logic probes to record relay operations on up to four channels, or use Differential Probe 9322 for 440-volt power measurements and for support of CAT III and CAT IV overvoltage measurement categories.
When facility troubles require waveforms right away!
Battery operation is especially convenient in those situations where no power outlet is available. Just plug in the supplied AC adapter to recharge the battery, regardless of whether the HiCORDER is on or off. The battery pack is automatically quick charged (autorecharging function) whenever its capacity is depleted. A full charge provides about two hours of operation.
Synchronize two HiCORDERs together for four-channel recording!
For those times when t wo channels are just not enough, synchronize two 8870-20's using the external trigger I/O terminals (apply the trigger output from one to the external trigger input of the other). Then use synchronous start to automatically record four channels of measurement data to a CF card.
5
Have you ever had an experience like these?
“ T he r e's a p r oble m w it h t he fa ci l it y, s o you ne e d t o s e e wavefor m s w it hout f u l l me a s u r e me nt i n s t r u me nt at ion…” “ You of t e n h ave t o v i sit wor k sit e s t o s e t u p pla nt s a nd fa ci l it ie s , but t y pic a l me a s u r e me nt i n s t r u me nt s a r e t o o bu l k y…” Fa s t , 1MS/s e c ond p e r for m a nc e d e s pit e it s c om p a c t si z e. I s olat e d i n put s e n s u r e s a fe c om me r cia l p owe r me a s u r e me nt s. Wavefor m d e t a i l s c a n b e e a si ly ob s e r ve d .
Unattended monitoring for unpredictably intermittent leakage phenomena
Record instantaneous waveforms of leakage current and line voltage. Use “Out-of-Window” triggering to detect leakage events only when the input is outside of specified upper and lower limits. Measurement data is saved to CF card whenever leakage phenomena occur. Later, reload the data into the 8 870 - 2 0 a n d u s e t h e cursor functions to analyze peak current values or breaker tripping events.
Record motor inrush current waveforms
Reliably record waveforms of motor startup current. Measure current signals preferably using the 9018-10 Clamp-On Probe, or with the 3283 CLAMP ON LEAK HiTESTER. Models 3284 and 3285 C L A M P O N AC/ D C HiTESTERs are also ideal for DC waveform measurements.
Confirm inverter output waveforms
Inverter performance analysis requires simultaneous observation of the high frequency carrier signal and the low frequency fundamental waveform being switched. The combination of high-speed sampling capability and high-capacity memory make these observations possible. For current waveform observations, use HIOKI clamp sensors capable of high-frequency measurements without direct electrical contact.
In the automobile servicing industry
Analyze phenomena in ways that are just not possible with dedicated fault diagnostic instruments. The high-speed sampling capability of the 8870-20 as a compact hand-held oscilloscope provides mobility in situations that call for delicate testing, such as when performing high-level analysis or measuring specifiable phenomena.
Capture momentary commercial power outages
Easily monitor the instantaneous waveform of 50/60 Hz commercial power. Use triggering to rec ord unexpected waveform anomalies. Capture momentary commercial power outages and voltage dips.
Long-period recording like a pen recorder
Record dual-level DC voltage systems as you would with a pen recorder. Use the 10 ms sampling rate to record momentary voltage fluctuations.The internal two-Megaword memory offers about five hours of recording with a 10 ms sampling interval.
6
■ Main unit Specifications
Basic specifications
No. of channels
(Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
Memory recorder functions
Time axis Sampling speed Recording length Pre-trigger 100 μs to 5 min/div, 20 ranges, time axis resolution 100 points/div, time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/1,000 in 9 stages, Auto roll mode display at 50 ms/div or slowely range
sampling in all channels)
2 analog and 4 logic channels (standard configuration, logic grounds
are common with instrument ground)
Measurement MEM (high-speed recording) functions Fastest sampling 1 MS/s (1 ms, all channels simultaneously) rate Memory capacity 12 bits × 2 MWords/ch Removable storage
1/100th of time axis range, (1 µs period maximum, simultaneous Ten settings from 20 to 20,000 div, or continuous
(limited by timebase, only the last 20,000 div are saved)
Clock and settings: 5 years or more (@25°C 77°F) Waveform backup function: available when BATTERY Backup function PACK 9780 is installed with charge remaining or AC adapter is connected (up to 100 hours with fully charged battery pack). USB: 1 port USB 2.0 High Speed mini-B receptacle, transfers files from the installed CF card to a PC when connected (mass storage External interface class device)
Note: The CF card installed in the HiCORDER appears as a removable disk on the PC, but communication functions such as the capability to change HiCORDER settings from the PC are not provided.
CF card Type I slot (standard equipment) × 1: Up to 1 GB (Flash ATA), supports FAT16 and FAT32 formats
Records waveforms prior to trigger events, from 0 to 100% of the specified recording length Split screen (none, only 1 screen), X-Y screen (none, but possible at use with the supplied PC software), Waveform or numerical logging (switched), Voltage axis zoom (×2 to ×10), compression (×1/2 to ×1/5)
digit displays as 0 for values 0 to 4, and 5 for values 5 to 9)
Screen types
Instantaneous value or RMS value display (only DC and 50/60 Hz) Reflesh rate: 0.5 sec, Sampling speed: 10 kS/sec, 4 digits: (the lowest Numerical display Voltage axis range: 10 mV, 50 mV, 100 mV, 500 mV, 1 V, 5 V, 10 V, 50 V/div, auto ranging, Accuracy : ±2.5 % of reading ±5 digits Up to four simultaneous calculations (common to all channels), calculation results are saved to CF card, Calculation contents: average, peak, maximum and minimum Numerical calculation values, RMS, period and frequency Calculation range: specified by A/B cursors or whole recording length Saving function Cursor readout Scaling function Comment entry Screen capture Gauges Preserve starting conditions Auto save Scroll bar Waveform monitor Logic signal view Setting configurations, measurement data (binary and text), screen data (compressed bitmap format), numerical calculation results, thinned data saving (text) Trace, vertical and horizontal Selectable by model (clamp or Differential Probe 9322), specified conversion ratio (output ratio, division ratio), 2-point setting method Title comments can be entered for each channel (including logic) The displayed screen is saved to CF card as a compressed bitmap Vertical axis gauges can be displayed for two channels on the waveform screen
External control terminals Display type Display resolution
Environmental conditions
(no condensation)
Terminal block: External trigger input, trigger output 4.3-inch WQVGA-TFT color LCD (480 × 272 dots) Waveform section: 20 × 10 divisions (time axis × voltage axis), each division is 20 × 20 dots Temperature and humidity range for use: 0°C (32°F) to 40°C (104°F), 80% rh or less Temperature and humidity range for storage: -10°C (14°F) to 50°C (122°F), 80% rh or less Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3
(AC adapter has priority when both are used)
Compliance standard Power requirements
AC ADAPTER 9786: 100 to 240 V AC (50/60 Hz) BATTERY PACK 9780: About 2h continuous operation 12 V DC supply: 10 to 16 V (cable available by special order)
The installed battery pack charges when the AC adapter is connected. Charging functions Charging time is about 200 minutes at 25°C (77°F).
Notes: Charging time depends on battery condition. Charging is disabled to protect the battery at ambient temperatures out of 5°C (41°F) to 30°C (86°F).
Power consumption Dimensions and mass Supplied accessories
30 VA max. (charging with the AC adapter) 10 VA max. (charging with a 12 V supply) Approx. 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 600 g (21.2 oz) (with the BATTERY PACK 9780 installed) Instruction Manual × 1, Measurement Guide × 1, AC ADAPTER 9786 × 1, Strap × 1, USB cable × 1, Application Disk (dedicated program for the 8 870-20 ) × 1, PROTECTION SHEET 9 809 × 1 Single or continuous
Included
If power fails while measuring, measurement can be automatically resumed when power is restored
To jump to a specific waveform location
Setting is possible while monitoring waveforms on the Settings screen In 4-bit units, four selectable display positions
Trigger functions
Trigger modes Trigger sources Two analog and four logic channels, external trigger (falls below 2.5 V, or shorted terminals), ON/OFF switching of each source, AND/OR between sources, manual triggering Level trigger: Triggering occurs when the signal rises or falls through a specified voltage level. Window trigger: Triggering occurs when the signal level rises above or falls below specified upper and lower limits. Voltage drop trigger: Intended particularly for 50/60 Hz commercial power, triggering occurs when the peak voltage is below the specified value. 1, 0, ×, or specified pattern Resolution : 0.5% of full scale (full scale = 10 divisions)
Trigger types (analog)
■ Maximum Recording Time for the Memory Function
• Because data is not recorded directly to the CF card, maximum recording time is independent of CF card capacity. Maximum recording time is determined only by internal memory capacity. • Operation cannot be guaranteed when recording continuously for more than one year (with a slow timebase). • Maximum recording length is the same whether using one or two channels.
Level setting Logic Trigger Trigger filter Other functions
Time axis
100 μs/div 200 μs/div 500 μs/div 1 ms/div 2 ms/div 10 ms/div 5 ms/div
Sampling period
1 μs 2 μs 10 μs 20 μs 100 μs 50 μs 5 μs
2M-Word (=4MB) 20,000 div Max.
2s 10 s 20 s 1 min 40 s 40 s 4s
Set by the number of samples, from 0 to 100, in five steps Pre-trigger recording to capture waveforms before and after triggering, trigger output (terminal block, 5-volt open-collector active
(Accuracy at 23 ±5°C/73 ±9°F, 80 % rh or less, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
low with at least 1 ms pulse width)
Analog Input
Measurement functions Input connectors Measurement range Measurement resolution
isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Number of channels: 2, for voltage measurement Isolated BNC connector (input impedance 1 MΩ, input capacitance 7 pF) Max. rated voltage to earth: 300 V AC, DC, CAT II (with input
100 ms/div 200 ms/div 500 ms/div 2 s/div 10 s/div 5 s/div 1 s/div
50 ms/div
20 ms/div
500 μs 1 ms 2 ms 10 ms 20 ms 100 ms 300 ms 600 ms 1.2 s 3.0 s 50 ms 5 ms
200 μs
16 min 40 s 33 min 20 s
6 min 40 s
3 min 20 s
Highest sampling rate 1 MS/s (simultaneous sampling in 2 channels) Accuracy
1/100 of measurement range (using 12-bit A/D conversion, measurement range is ±10 times per-division range value)
10 mV to 50 V/div, 12 ranges, full scale: 10 div, AC voltage for possible measurement/display using voltage axis × 1/2: 280 Vrms, Low-pass filter: 5 Hz/50 Hz/500 Hz/5 kHz
1 h 06 min 40 s 5 h 33 min 20 s 2 h 46 min 40 s
1 d 03 h 46 min 40 s 2 d 07 h 33 min 20 s 13 d 21 h 20 min 00 s 27 d 18 h 40 min 00 s 69 d 10 h 40 min 00 s 6 d 22 h 40 min 00 s
11 h 06 min 40 s
Frequency characteristics DC to 50kHz -3dB Input coupling DC/GND
DC amplitude: ±0.5 % of full scale (after zero-adjust, f.s. = 10 div of per-division measurement range)
1 min/div 2 min/div 5 min/div
30 s/div
Max. allowable input 400 V DC (the maximum voltage that can be applied across input pins without damage)
7
■ Features of the Dedicated Wave Processor Program (supplied accessory)
l Designed especially for MEMORY HiCORDER 8870-20 Application program displays and prints waveforms, and converts measurement data to CSV text files on a Windows PC. l Provides X-Y display capability not available on the HiCORDER l Generate reports using templates, with figure annotations and entered comments l Multiple files can be batch-converted to CSV data
Wave Processor Program for the 8870 -20
Supported measurement MEMORY HiCORDER 8870-20 only instruments Operating environment PC running Windows 2000, XP, or Vista (32-bit versions) File loading Overwriting save Loadable data format: Memory function data (MEM extension) Max. loadable file size: The maximum size that can be stored by the 8870-20 (subject to the capacity of the PC’s operating environment) Overwrites saved scaling and title/channel comments Displaying
Slideshow display Sequentially displays waveform files in the same folder Data conversion format: Select from CSV, tab-separated or spaceseparated Object data range: Whole range, or between cursors Data thinning: Available by specifying interval Conversion methods: Analog waveform data to voltage values, logic data is converted to ones and zeros Conversion channels: selectable Header contents: Title, trigger date, timebase, comments, per-channel setting conditions Batch conversion: specify multiple files for batch conversion
Display language: English or Japanese (select during installation) Waveform display: Scroll and magnify/reduce the time axis of the displayed waveform data image, move the zero position of each channel, zoom and set the vertical axis of each channel independently (variable gain) Numerical value display: included Cursor functions: Manipulate A and B cursors independently, and display time and voltage numerically. Max. displayable channels: two analog and four logic channels Gauge display: Time gauge (absolute or relative time, seconds, data points), voltage gauge (for each channel) Figure annotations: Text boxes, straight lines, arrows, circles and rectangles at any location Screen capture: Extended meta format, bitmap format Search functions: Date, maximum, minimum, level and window search Template function: Save and reload waveform file display configurations Printer support: Color and monochrome printing on printers supported by the operating system Printable ranges: All data, screen capture and specifiable areas Print formats: Undivided, two divisions, 2, 4, 8 or 16 traces, single XY screen, gauges, channel comments, zero-position comments, and A/ B cursor values Print preview and waveform screen hard copy/logging print functions are included
Text conversion
Printing
■ Options specifications ( sold separately)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) Note: The unit-side plug of the 9320-01 is different from the 9320. Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz)
LOGIC PROBE 9320 -01
Function
Detection of voltage signal or relay contact signal for High/Low state recording
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
DIFFERENTIAL PROBE 9322
Function
Input
Digital input threshold 1.4 V/2.5 V/4.0 V 1.5 kΩ or higher (open) and 500 Ω or lower (short), 3.5 kΩ or Contact input higher (open) and 1.5 kΩ or lower (short), 25 kΩ or higher (open) detection resistance and 8 kΩ or lower (short) Response speed Max. allowable input 500 ns or lower 0 to +50 V DC (the maximum voltage that can be applied across input pins without damage)
4 channels (common ground between unit and channels), digital/ contact input, switchable (contact input can detect open-collector signals), input impedance: 1 MΩ (with digital input, 0 to +5 V), 500 kΩ or more (with digital input, +5 to +50 V), pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V)
DC mode
For waveform monitor output, frequency characteristics: DC to 10 MHz (±3 dB), amplitude accuracy: ±1 % of full scale (at max. 1000 V DC), ±3 % of full scale (at max. 2000 V DC) (full scale: 2000 V DC) For detection of power line surge noise, frequency characteristics: 1 kHz to 10 MHz ±3 dB DC/AC voltage RMS output detection, frequency characteristics: DC, 40 Hz to 100 kHz, response speed: 200 ms or less (400 V AC), accuracy: ±1 % of full scale (DC, 40 Hz to 1 kHz), ±4 % of full scale (1 kHz to 100 kHz) (full scale: 1000 V AC)
For high-voltage floating measurement, power line surge noise detection, RMS rectified output measurement
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year)
AC mode
RMS mode
Input Maximum allowable input Output Power source
Input type: balanced differential input, input impedance/ capacitance: H-L 9 MΩ/10 pF, H/L-unit 4.5 MΩ/20 pF, Max. rated voltage to earth: when using grabber clip 1500 V AC/DC (CAT II ), 600 V AC/DC (CAT III), when using alligator clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III) 2000 V DC, 1000 V AC (CAT II), 600 V AC/DC (CAT III) Voltage divider for 1/1000 of input, BNC connectors (output switchable for 3 modes DC, AC, RMS) Connect the AC ADAPTER 9418-15, (power cannot be supplied from the logic terminals of the 8870-20)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) Note: The unit-side plug of the 9321-01 is different from the 9321.
LOGIC PROBE 9321-01
Function Input Output (H) detection Output (L) detection
Detection of AC or DC relay drive signal for High/Low state recording. Can also be used for power line interruption detection 4 channels (isolated between unit and channels), HIGH/LOW range switching, Input impedance: 100 kΩ or higher (HIGH range), 30 kΩ or higher (LOW range) 170 to 250 V AC, ±DC (70 to 250 V ) (HIGH range) 60 to 150 V AC, ±DC (20 to 150 V) (LOW range)
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year)
0 to 30 V AC, ±DC (0 to 43 V) (HIGH range) 0 to 10 V AC, ±DC (0 to 15 V) (LOW range) Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range Response time at 200 V DC, LOW range at 100 V DC) Maximum allowable 250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage) input voltage
8
Supplied AC Adapter Options for Voltage measurement (Not supplied. Purchase together with attachment clips appropriate for your application.)
ALLIGATOR CLIP 9790-01 Red/black set attaches to the ends of test leads (9790) GRABBER CLIP 9790-02
CONNECTION CORD 9790
(Thin Type) CAT II 300V, ultraflexible 2.8 mm (0.11 in) diameter test lead cable, 1.5 m (4.92 ft) length Note: Attachment clips sold separately.
Red/black set attaches to the ends of test leads (9790)
CONTACT PIN 9790-03
Red/black set attaches to the ends of test leads (9790)
Battery Pack
Tip Expanders 9790-01 Tip Expanders Attachment clips are sold separately from CONNECTION CORD 9790. Purchase the appropriate attachment clips for your application separately
Tip Expanders 9790-03
Charges while installed in the HiCORDER
BATTERY PACK 9780
Tip Expanders 9790-02
NiMH, Charges while installed
Voltage measurement (Requiring power for probe)
Removable storage
Supplied with PC Card adapter
PC CARD 128M 9726 (128MB capacity)
DIFFERENTIAL PROBE 9322
2 kV DC for input up to 1 kV AC, CAT III-600 V and CAT II-1000 V maximum terminal-to-ground rating
AC ADAPTER 9418-15
For powering Differential probe 9322, 100 to 240 V AC, 12 V/2.5 A
U s e o n l y P C C a rd s s o l d by HIOKI. Compatibility a n d p e r f o r m a n c e a re n o t guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
PC Card Precaution
PC CARD 256M 9727 (256MB capacity) PC CARD 512M 9728 (512MB capacity) PC CARD 1G 9729 (1GB capacity)
Voltage measurement
Case
MEMORY HiCORDER 8870-20 (English model, instrument only)
CONNECTION CORD 9198 CONNECTION CORD 9197
Note: Test leads are not included. Purchase the leads appropriate for your application separately. AC Adapter 9786 is the only supplied accessory.
SOFT CASE 9812
CAT II-300 V, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length
CAT II-500 V, 5-mm (0.20 in) dia. cable, 1.5 m (4.92 ft) length
Includes space for small items, Neoprene rubber
Logic signal measurement (One probe can be installed to provide four channels)
Supplied Accessories
Case
CONVERSION CABLE 9323 LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal ON/OFF detection (miniature terminal type)
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF detection of AC/DC voltage * This cable is not required for the smallterminal (miniature terminal type)
types 9320-01 and 9321-01.
Used for connecting the 9320/9321 and 8870 series MEMORY HiCORDERs, because the terminal shapes are different.
PROTECTION SHEET 9809 AC ADAPTER 9786
For LCD protection, pairs of additional sheets can be purchased separately. 100 to 240 V AC
CARRYING CASE 9782
Includes compartment for options, Resin coated
Current measurement
Not CE marked
CLAMP ON LEAK HiTESTER 3283
10 mA to 200 A AC
CLAMP ON AC/DC HiTESTER 3284
20 A to 200 A AC/DC
Clamp tester connection requires OUTPUT CORD 9094 and Conversion Adapter 9199.
CLAMP ON PROBE CLAMP ON PROBE 9018-50 9132-10
10 A to 500 A 20 A to 1000 A
CLAMP ON AC/DC HiTESTER 3285 AC ADAPTER 200 A to 2000 A AC/DC 9445-02/-03
OUTPUT CORD 9094
Not CE marked
for the 3283/3284/3285, 9V/1A
3.5-mm mini plug, and banana plugs, 1.5 m (4.92 ft) length
CONVERSION ADAPTER 9199
Female banana terminals to BNC plug (output)
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: info-sh@hioki.cn
DISTRIBUTED BY
HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: info-bj@hioki.cn
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.cn 8870-20E1-85M-05P Printed in Japan
All information correct as of May 22, 2008. All specifications are subject to change without notice.